CT (ACTP)
2ds_61205_en_ct_power: 010113J
2. Specifications
Characteristics Item Specifications
Contact Arrangement 1 Form C 2, 1 Form C
Contact resistance (Initial) N.O.: Typ 7m, N.C.: Typ 10m (By voltage drop 6V DC 1A)
Contact material Ag alloy (Cadmium free)
Rating
Nominal switching capacity (resistive load) N.O.: 30 A 14V DC, N.C.: 10 A 14V DC
Max. carrying current (14V DC)*3N.O.: 40 A for 2 minutes, 25 A for 1 hour at 20C 68F, 35 A for 2 minutes, 20 A for 1 h our at 85C 185F
Nominal operating power 1,000 mW
Min. switching capacity (resist ive load)*11 A 14V DC
Electrical
characteristics
Insulation resist ance (Initial) Min. 100 M (at 500V DC, Measurement at same location as “Br eakdown voltage” section.)
Breakdown
voltage (Initial) Between open contacts 500 Vrms for 1 min. (Detection current: 10mA)
Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA)
Operate time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Release time (at nominal voltage) Max. 10ms (at 20C 68F, excluding contact bounce time) (Initial)
Mechanical
characteristics
Shock
resistance Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
Vibration
resistance
Functional 10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10s)
Destructive 10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G},
T i me of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected life
Mechanical Min. 107 (at 120 cpm)
Electrical
<Resistive load>
Min. 5 104 (at nominal switching capacity, operating frequency: 1s ON, 9s OFF)
<Motor load>
N.O. side: Min. 105 (at Inrush 30A, Steady 7A 14 V DC),
Min. 5 104 (at 30A 14 V DC motor lock condition)
N.C. side: Min. 105 (at brake current 15A 14 V DC) (operating frequency: 0.5s ON, 9.5s OFF)
Conditions Conditions for operation, transport and
storage*2Ambient temperature: –40C to +85C –40F to +185F,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 6 cpm (at nominal switching capacity)
Mass Twin type: approx. 8 g .28 oz, 1 Form C type: approx. 4 g .14 oz
Notes:
*1.This value can change due to the switching fr equency , environment al conditions, and desired reliability level, there fore it is recommended to check this with the actual load.
*2.The upper operation ambient temperature limit is the maximum temperature that can satisf y the coil temperature rise value. Refer t o “ 6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Please inquire if you will be using the relay in a high temperature atmosphere (110C 230F).
*3.Depends on connection conditions. Also, this does not guarantee repeated switching. We recommend that you confirm operation under actual conditions.