LTC Batteries Size: AA Extended temperature range Performance Data (Typical values for batteries stored at +25 C for one year) 4.0 System Nominal voltage Nominal capacity Nominal current Max. continuous discharge current Anode surface area Lithium content Weight Volume Temperature range 3.5 Lithium Thionyl Chloride 3.6 V 1.7 Ah 2 mA 20 mA 14 cm2 0.65 g 18 g 8 cm3 -55 C ... +130 C Voltage / V 3.0 2.0 0.5 0.0 0.70.3 +0.2 -0.3 Capacity to 2 Volts / Ah SL-560/T 3 4 6 5 0.1 1 10 102 Time / h 103 7 1.40 Ah 1.70 Ah 1.70 Ah 1.65 Ah 1.50 Ah 1.25 Ah 1.00 Ah 104 105 Available Capacity 2.0 0.2 mA 1.5 1.0 2 mA 0.5 40 55 70 85 10 0 11 5 13 0 14 5 55 70 85 10 0 11 5 13 0 14 5 25 40 10 0 -5 -2 0 -5 3.17 5 0.0 70.5 50.5-1.5 2 1: 180 ~20 mA 2: 560 ~6 mA 3: 1.8 k ~2 mA 4: 5.6 k ~0.6 mA 5: 18 k ~0.2 mA 6: 56 k ~0.06 mA 7: 180 k ~0.02 mA 1.5 1.0 SL-560/S + 1 2.5 2.5 O 4.2 Typical Discharge Curves at +85 C -3 SL-560 Temperature / C 0.15 thick 45 Operating Voltage 3.6 3.4 Voltage / V O 14.7-1.2 3.8 O 0.8 O 0.8 SL-560/P 45 3.2 3.0 0.2 mA 2 mA 20 mA 2.8 2.6 25 Temperature / C 3.5 4+0,5 1-0.1 1-0.1 0.2 thick 0.2 thick Available Terminations Catalogue No. SL-560/S SL-560/T SL-560/P SL-560/PR SL-560/PT 11 1 05601 00 11 1 05602 00 11 1 05603 00 11 1 05606 00 11 1 05608 00 Standard Tags Pins Pins radial Polarized tags 10.16 WARNING: Fire, explosion, and severe burn hazard. Do not recharge, disassemble, heat above 150 C, incinerate, or expose contents to water. Any values given here are for informational purposes only. They also depend on actual conditions of use and are not warranties of future performance. Subject to change. 11 PDC13Eng 3.5 4+0,5 10 2.4 -5 SL-560/PT -5 0 -3 5 -2 0 SL-560/PR Tadiran Batteries GmbH * Industriestr. 22 * 63654 BUDINGEN GERMANY * Tel.: +49 (0)6042 954-0 * www.tadiranbatteries.de