Thermal-Magnetic Circuit Breaker 2215-L.../G... Description Miniaturised single pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Two designs provide the option of either printed circuit board or threadneck panel mounting. A separate shunt tap terminal and auxiliary contacts are available. Fast acting, medium or long delay characteristics can be specified for both models. Suitable for use in distribution rails - see section Power Distribution Systems. Complies with CBE standard EN 60934 (IEC 60935). 1 Typical applications 2215-L1.. Control equipment, communications systems, instrumentation. Suitable for mounting on Euro cards. 2215-G1... Technical data Ordering information 2215-G1 Type No. 2215 single pole thermal-magnetic circuit breaker Mounting G1 threadneck panel mounting Number of poles 1 1-pole protected Mounting hardware 1 2 hex nuts 1/4"-40 UNS-2A, serrated washer, location pin (-G1 only) Terminal design (main contacts) P1 blade terminals 6.3-0.8, without shunt terminal Characteristic curve F1 fast acting:1.01-1.4xIN; magn.2-4xIN DC (DC only) M1 standard delay: therm. 1.01-1.4xIN; magn. 4.5-10.5xIN DC; magn. 3.5-8xIN AC T1 delayed: therm. 1.01-1.4xIN; DC magn. 8-17xIN DC, 6-13xIN AC Auxiliary contacts S0 without auxiliary contact S11 with auxiliary contact (change over) blade terminals 6.3x0.8 (QC .250) Current ratings 0.05...10 A 2215 - G1 1 1 - P1 F1 - S11 - 0.5 A ordering example Ordering information 2215-L1 Type No. 2215 single pole thermal-magnetic circuit breaker Mounting L1 PCB mounting Number of poles 1 1-pole protected Mounting hardware 0 without accessories Terminal design (main contacts) L1 solder pins, without shunt terminal Characteristic curve F1 fast acting:1.01-1.4xIN; magn.2-4xIN DC (DC only) M1 standard delay: therm. 1.01-1.4xIN; magn. 4.5-10.5xIN DC; magn. 3.5-8xIN AC Auxiliary contacts - terminal design S0 without auxiliary contact S12 with auxiliary contact (change over) solder pins Current ratings 0.05...10 A 2215 - L1 1 0 - L1 F1 - S12 - 0.5 A ordering example 1633 Voltage rating Current rating range Auxiliary circuit Typical life Ambient temperature Insulation co-ordination (IEC 60664 and 60664 A) Dielectric strength IEC 60664 and 60664A) operating area main/aux. circuit Insulation resistance Interrupting capacity Icn Interrupting capacity (UL 1077) Degree of protection (IEC 60529/DIN 40050) Vibration curve F1: curves M1, T1: Shock curves F1, M1, T1: curve F1: curves M1, T1: Corrosion Humidity Mass AC 250 V (50/60 Hz); DC 50 V (UL: AC 250 V; DC 75 V) 0.05...10 A (higher current ratings to special order) 1 A, AC 250 V / DC 28 V 10,000 operations at 1 x IN -30...+60 C (-22...+140 F) rated impulse pollution withstand voltage degree 2.5 kV 2 reinforced insulation in operating area test voltage AC 3,000 V AC 1,500 V > 100 M (DC 500 V) 300 A IN UN 0.05 A AC 250 V 0.1...6 A AC 250 V 8...10 A AC 250 V 0.05...10 A DC 50 V operating area IP30 terminal area IP00 200 A 1,000 A 2,000 A 1,000 A 6 g (57-500 Hz), 0.46 mm (10-57 Hz) 8 g (57-500 Hz), 0.61 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis 30 g (11 ms), directions 1, 2, 3, 4, 5, 10 g (11 ms), direction 6 15 g (11 ms), direction 6 to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-78, test Cab approx. 25 g Approvals Authority Standard Rated voltage Current ratings UL UL 1077 AC 250 V DC 75 V 0.05 A...10 A 0.05 A...10 A (20 A) CSA C22.2 No. 235 AC 250 V DC 75 V 0.05 A...10 A 0.05 A...10 A (20 A) www.e-t-a.de 1 Thermal-Magnetic Circuit Breaker 2215-L.../G... Standard current ratings and typical internal resistance values Current ratings (A) Internal resistance () 0.05 440 1.5 0.55 0.1 108 2 0.34 0.2 29.9 2.5 0.21 0.3 14.2 3 0.15 0.084 0.057 0.6 3.5 6 0.043 0.8 1.8 8 0.02 1.2 10 16 .630 4 5 19 .748 0.02 12 11 14 4 .157 LINE 2 4 .157 1 3 .118 mounting area (standard insulation) Dimensions 2215-L1.. 25 25 4 .157 spacer 0 Internal connection diagram 14 .551 I 11 .433 7.9 5.0 35 1.38 0.4 0.5 1 operating area (reinforced insulation) 14 .551 Internal resistance () 1.7 .067 0 o1.5 .059 25.6 1.01 line 1 I 11 11 .433 52 2.05 49 1.93 5 .197 12 14 LINE 2.5 .098 12 11 14 1 I> 1x0.8 1x.031 2 6 .236 * 11.5 .453 2 29 1.14 Shock directions Dimensions 2215-G1.. 5 10 10 0 I lock washer * 11 14 6 .236 29 1.14 1 53.5 2.11 blade terminals DIN 46244-A6.3-0.8 (QC .250) 9 .354 LINE 2.5 .098 2 11 .433 12 1 8 .315 hex nut 2 3 4 o3 .118 serrated washer 19 .748 threadneck 1/4"-40 UNS-2A 6 tightening torque max. 1 Nm 52.5 2.07 11.5 .453 front panel cut-out o6.4+0.1 .252+.004 6.1 .240 1 Current ratings (A) Installation drawing o2.4+0.1 .094+.004 2 This is a metric design and millimeter dimensions take precedence ( mm ) inch www.e-t-a.de 1633 Thermal-Magnetic Circuit Breaker 2215-L.../G... Typical time/current characteristics -F1 0.05...6 A DC only -F1 8...10 A DC only -M1 0.05...6 A 1000 1000 1000 100 100 100 10 1 Trip time in seconds 10000 Trip time in seconds 10000 Trip time in seconds 10000 10 1 1 0.1 0.1 0.01 0.01 0.01 0.001 1 2 1 4 6 8 10 20 40 60 80 100 ... times rated current -M1 8...10 A AC/DC 1) 2 0.001 4 6 8 10 20 40 60 80 100 ... times rated current -T1 0.05...6 A AC/DC 1) 1 1000 1000 100 100 100 1 Trip time in seconds 1000 Trip time in seconds 10000 Trip time in seconds 10000 10 1 0.1 0.01 0.01 0.01 0.001 0.001 2 4 6 8 10 20 40 60 80 100 ... times rated current +60 C +140 F 1 -30 C -22 F +23 C +73.4 F 0.05...10 A: 1) AC/DC 1) 1 0.1 1 4 6 8 10 20 40 60 80 100 ... times rated current 10 0.1 0.001 2 -T1 8...10 A 10000 10 1 10 0.1 0.001 AC/DC 1) 2 4 6 8 10 20 40 60 80 100 ... times rated current 1 2 4 6 8 10 20 40 60 80100 ... times rated current Magnetic tripping currents are increased by 30 % on DC supplies (curve M1 and T1). Ambient F temp. C -22 -30 -4 -20 +14 -10 +32 +73.4 +86 0 +23 +30 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit +104 +122 +140 breaker current ratings by the derating factor shown below. See also section +40 +50 +60 Technical information. Derating factor 0.76 0.79 0.83 0.88 1.11 1 1.04 1.19 1.29 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 1633 www.e-t-a.de 3 1 4 www.e-t-a.de 1633