CIRCUIT BREAKERS SAFRAN ELECTRICAL & POWER SMARTER ELECTRICAL SOLUTIONS FOR A BETTER FLIGHT At Power we innovate to provide greener, reliable and cost-effective electrical solutions. We are one division "Powering-On" to be a world class trusted supplier. 2 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." CIRCUIT BREAKER CATALOG Table of Contents 3 4 5 5 6-7 8-9 10 11 Capabilities and Product Overview Table of Contents Descriptive Index Fast Information Finder Part Number to Page Index Single Phase, Circuit Breakers Capabilities and Product Overview Circuit Breaker Product Overview Organizational Capabilities Three Phase, Circuit Breakers Arc Fault Circuit Interrupt (AFCI) Technology Notes 12-13 14-15 16-17 18-19 20-21 22-23 24-25 Single Phase, Thermal Circuit Breakers Series 160 - 50 to 100A Series 170 - 125 to 200A Series 700 - 5 to 50A Series 1500 - 1/2 to 10A Series 4001 - 1 to 25A Series 4200 - 1 to 25A Series 4310 - 1 to 25A 26-27 28-29 30-31 32-33 Three Phase, Thermal Circuit Breakers Series 940 - 50 to 100A Series 1526 - 1 to 15A Series 1536 - 5 to 50A Series 4330 - 1 to 20A 34-37 38-39 Remote Controlled Circuit Breakers Remote Controlled Circuit Breakers Remote Power Controllers 40 Additional Circuit Breaker Products Additional Products 40 Accessories Rubber Boot Assembly Remote Controlled Circuit Breakers Additional Circuit Breaker Products Accessories Reference 41 42 "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 3 DESCRIPTIVE INDEX Accessories 40 AFCI 10 Auxiliary Terminal 4200 Series RCCB RPC 22 34 38 Capabilities 8 Military Approved Devices 160 Series 170 Series 700 Series 4001 Series 12 14 16 20 4200 Series 4310 Series 4330 Series RCCB 22 24 32 34 Random Vibration Cross Reference 5 700 Series 4001 Series 4200 Series 16 20 22 42 Fast-Trip (Load Protection) 1500 Series 1526 Series 18 28 High Vibration 160 Series 700 Series 4001 Series 4310 Series 4330 Series 12 16 20 24 32 Hot-wire 1500 Series 1526 Series 18 28 Indicator Control Unit (ICU) 1500 Series 18 Long Button 700 Series 4200 Series 4310 Series 4330 Series 4 16 22 24 32 Remote Controlled RCCB RPC 34 38 Single Phase 160 Series 170 Series 700 Series 1500 Series 4001 Series 4200 Series 4310 Series RCCB 12 14 16 18 20 22 24 34 Temperature Compensated 1500 Series 18 1526 Series 28 1536 Series 30 4310 Series 4330 Series 24 32 Three Phase 940 Series 1526 Series 1536 Series 26 28 30 4330 Series RCCB 32 34 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." FAST INFORMATION FINDER Find Information Fast Part Number to Page Index * Have a Safran Electrical & Power part number and need more information? Use the part number to page index on this page to get the exact page of the full product listing. Safran Part No. 60160160-012160-086100130140170170-001180260270700700-001700-089700-092780920930940940-006960970120015001500-05215261526-00515361536-005153815401585210040014001-0014001-0084001-0114200- Page No. 40 12 12 12 40 40 40 14 14 40 40 40 16 16 16 16 40 40 40 26 26 40 40 40 18 18 28 28 30 30 40 40 40 40 20 20 20 20 22 4200-0014200-0034200-0044200-0064200-00743104310-0014310-0054310-0194310-024- 22 22 22 22 22 24 24 24 24 24 * Have a Military part number and need applicable Safran Electrical & Power part number? Use the Military part number Index in the back of this catalog. * Know the type of product you want, but not a specific part number? Use the detailed Index on the facing page to find the section with those products or use the Product Overview for a quick side by side comparison. * Looking for a specific feature or attribute? Use the Descriptive Index or Product Overview to quickly determine which products fit your application. * Need additional information not contained in this Safran Part No. 43304330-0014330-0074330-0084330-009438085009500SM600BA - SM600BA125 (+) SM601BA - Page No. 32 32 32 32 32 40 40 40 34 38 34 "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 5 CIRCUIT BREAKER PRODUCT OVERVIEW PLEASE CONSULT DETAILED PRODUCT DESCRIPTIONS FOR MORE INFORMATION. SINGLE PHASE 160 Series 170 Series 700 Series pgs. 12-13 pgs. 14-15 pgs. 16-17 pgs. 18-19 pgs. 20-21 MS25361 MS25017(4) MS25244 (MS25017)(4) MS22074(4) MS22073 Heavy-Duty, High Heavy-Duty, Very High Miniature, High Current Ratings Current Ratings Interrupting Capacity, Rugged Performer Ambient Temperature Current Rating Voltage rating 50 to 100 Amperes 125 to 200 Amperes 5 to 50 Amperes Compensated 1 to 25 Amperes 120 VAC, 400 Hz; 115 VAC, 400 Hz; 120 VAC, 400 Hz; 0.5 to 10 Amperes 120 VAC, 400 Hz; (For Interrupting Capacity) Calibration @25 C 30 VDC 28 VDC 30 VDC 120 VAC, 400 Hz; 30 VDC 105% Hold 100% Hold 115% Hold 30 VDC 115% Hold (percent of amperage rating) 138% within one 125% within one 138% within one hour 115% Hold 150% within one hour hour hour All amperages All amperages All amperages 15.0 to 65.0 15.0 to 70.0 15.0 to 55.0 0.5-3A / 4.5-10A 2.0 to 20.0 1.3 to 6.0(2) 1.5 to 6.5(2) 1.4 to 5.0(2) 0.4 to 3.0 / 0.8 to 3.6 0.16 to 2.0 0.5 to 2.0(3) 0.5 to 2.5(3) 0.5 to 1.5(3) 0.06 to 0.4 / 0.08 to 0.046 to 0.5 3500A @ 120V AC 2500A @ 115V AC 3500A @ 120V AC 0.5(2) 500 to 3500A @ 120V AC (Rating Dependent) 6,000A @ 30V DC 3,000A @ 28V DC 6,000A @ 30V DC 0.02 to 0.18 / 0.02 to 0.2(3) 2,000 to 6,000A @ 30V DC Weight g (lb.) Major Dimensions 113g (.250lb) 130g (.286lb) 43g (.095lb) 600 to 1000A @ 120V AC 33g (.073 lb) 2.250 x 1.812 x 0.750 2.250 x 1.812 x 1.00 1.860 x 1.094 x 0.750 6,000A @ 30V DC Catalog Location MS Qualified Description Trip Time (in seconds at 25 C) 200% Overload 500% Overload 1000% Overload Interrupting Capacity Miniature, Fast-trip, 4001 Series Sub-miniature, Precision, Lightweight 138% within one hour LxWxH (inches) Notes 1500 Series All amperages 1.852 x 0.703 x 0.593 45g (.099 lb) MIL spec approved Mounting dimensions Available with auxiliary high vibration model. compatible with switch. P-bracket allows Military Standard variation of mounting. 40 Meets requirements for random vibration models Drawing require- & 50 ampere ratings not use as an RCCB ICU. and variations in termina- ments of MS25017 of MIL spec approved. I2t function is per speci- tion and mounting. 25 fication. ampere rating not MIL MIL-C5809. 1.843 x 1.137 x 0.750 Available in MIL spec approved high vibration and spec approved. (1) Balanced, Unbalanced load 145% (2) 400% Overload information available in detailed product listing (3) 600% Overload information available in detailed product listing (4) Designed to requirements of applicable specification. Contact Business Unit for details. FOR CONFIGURATIONS NOT NOTED, CONTACT BUSINESS UNIT 6 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." CIRCUIT BREAKER PRODUCT OVERVIEW PLEASE CONSULT DETAILED PRODUCT DESCRIPTIONS FOR MORE INFORMATION. THREE PHASE Catalog Location MS Qualified Description 4200 Series 4310 Series 940 Series 1526 Series 1536 Series 4330 Series pgs. 22-23 pgs. 24-25 pgs. 26-27 pgs. 28-29 pgs. 30-31 pgs. 32-33 MS26574 MS3320 (AS33201) NA NA NA MS14154 Sub-miniature, Heavy Duty, High Fast-trip, Hot-wire, Miniature, Sub-miniature, Sub-miniature, High- Performance, Lightweight Lightweight, Ambient Capacity Protection Ambient Temperature Lightweight, Compensated Temperature Compensated Lightweight, Ambient Ambient Temperature Temperature Compensated Compensated Current Rating Voltage rating 0.5 to 25 Amperes 1 to 25 Amperes 50 to 200 Amperes 1 to 15 Amperes 5 to 50 Amperes 1 to 25 Amperes 120 VAC, 400 Hz; 120 VAC, 400 Hz; 120 VAC, 400 Hz 120 VAC, 400 Hz 120 VAC, 400 Hz 120 VAC, 400 Hz (For Interrupting Capacity) 28 VDC 28 VDC Calibration @25 C 115% Hold 115% Hold 105% Hold 115% Hold 105% Hold 110% Hold 138% within one 138%(1) within 138% within one 138%(1) within 145% within one hour one hour hour one hour hour All amperages All amperages 1-7.5A / 10-15A All amperages All amperages 5.0 to 20.0 15.0 to 70.0 0.35 to 4.0 / 3.0 to 10.0 10.0 to 70.0 4.0 to 20.0 0.16 to 1.2 0.5 to 2.0 1.2 to 6.0(2) 0.06 to 0.45 / 0.4 to 1.4 to 6.0(2) 0.40 to 2.00 0.046 to 0.8 0.12 to 0.53 0.4 to 2.0(3) 0.95(2) 0.35 to 1.4(3) 0.10 to 0.53 500A to Unlimited @ 120V AC 2000 to 3500A @ 120V AC 1200A @ 120V AC 0.02 to 0.15 / 0.15 to 1000A @ 120V AC 2000A @ 120V AC 2000A to Unlimited @ 0.5(3) (percent of amperage rating) Trip Time (in seconds at 25 C) 200% Overload 500% Overload 1000% Overload Interrupting Capacity (Rating Dependent) 150% within one hour All amperages 2.0 to 20.0 6,000A @ 28V DC 300A @ 120V AC 28V DC Weight g (lb.) Major Dimensions LxWxH (inches) Notes 22g (.048 lb) 25g (.055lb) 388g (.854 lb) 130g (.290 lb) 68g (.150 lb) 1.525 x 0.780 x 0.593 1.343 x 0.781 x 0.593 2.437 x 2.187 x 2.170 x 2.160 x 1.381 x 1.840 x 154g (.340lb) 0.781 1.875 x 2.063 x Single hole mount MIL spec approved MIL spec approved ran- MIL spec approved All data listed is and small size facili- high vibration and dom vibration and long long button and high applicable to the 1.300 For additional amper- tate easy installation. long button models. button models. Available vibration models. 940 Series. 25 ampere rating is age ratings consult with auxiliary switch and Available with auxiliary Consult Safran not MIL spec variations in termination switch and variations Electrical & Power business unit. approved. Single and mounting. 0.5 and in termination and for details on the Hole mount. 25 ampere rating not MIL mounting. 1.5 & 25 180, 920, 930, Variation in terminaspec approved. ampere ratings not 960, and 970 tion and mounting MIL spec approved. Series devices. available. 2.631 1.312 "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 7 CAPABILITIES Market Trends Aircraft Original Equipment Manufacturers (OEM) are continuously pursuing efficiencies associated with the design and manufacture of aircraft platforms. Additionally, the OEM's are working on increasing the functionality of components while reducing operating and life cycle costs. These activities are leading to the migration of engineering and system design activities to Tier 1 system integrators and their supply partners such as Safran Electrical & Power. By optimizing relays, circuit breakers, and power distribution panel performance to satisfy application requirements; cost, size, weight can be minimized while enhancing performance. What Problem Does SafranElectrical&Power Solve? Aircraft OEM's have already discovered outsourcing power distribution management requirements to Tier 1-system integrators and their vendor base is an effective alternative that mitigates risk and leverages the subsystem and component manufacturer expertise. The success of such outsourcing efforts benefits the OEM and leads to more reliance on qualified Tier 1-system integrators for electrical systems. Safran Electrical & Power's objective is to be the logical candidate for the supply of aerospace components as well as subsystems that address power distribution and circuit protection. 8 Safran Electrical & Power offers Integrated Circuit Breaker Panels as a Line Replaceable Unit that reduce the OEM production installation time and eliminates component compatibility / interface issues. This can shorten design to market cycle time and reduce costs by outsourcing subsystems to qualified suppliers with the requisite engineering skill and manufacturing capabilities. The Safran Electrical & Power Solution SafranElectrical&Power is an attractive partner in the design and development of integrated circuit breaker components and subsystem panels. Our development process employs sound methodology to identify, assess, and manage program risk. The components of this approach include Phase-Gate Reviews, Project Management, and Six Sigma for Design and Development. This process in conjunction with SafranElectrical& Power's extensive Product Portfolio and Capabilities enable Safran Electrical & Power to be a single source supplier for power protection, distribution, and switching components. The Systems Integrators have the option of sourcing pedigree circuit breakers for their panel designs or subcontracting the entire Integrated Circuit Breaker Panel to Safran Electrical & Power. Phase-Gate Reviews This process organizes product development activities from the idea through product launch into a series of phases. The activities within each phase are multifunctional, and are designed to provide information that progressively reduces risk. Consistent application of the process promotes successful on-time product development efforts. Project Management Product development projects involve the iterative planning, execution and control of project team activities in order to meet the competing demands of scope, timing, cost, risk and quality. Project management methodology affords the application of knowledge, skills, tools and techniques to meet these requirements. Six Sigma for Design and Development Six Sigma for Design and Development is a methodology using normal Six Sigma tools, but applies them early in the design process. This methodology instills the product development process with the same Six Sigma process rigor found in Safran manufacturing to create successful products in a competitive marketplace. Product Portfolio Safran Electrical & Power's complete product portfolio allows flexibility to partner with customers having a variety of circuit breaker subsystem and component needs. Safran Electrical & Power's engineers design additional value into traditional thermal circuit breaker components and subsystems through electronics, while balancing customer concerns for size, weight, cost, and complexity. Arc Fault Interrupt Technology is an example of value add engineering. A proven design package (i.e. thermal circuit breaker) is modified so its functionality addresses emerging airline carrier and Federal Aviation Administration needs to protect the aging aircraft fleet and satisfy SFAR 88 requirements. The Safran Electrical & Power product portfolio is recognized in the aerospace industry as MIL qualified for performance rated switching products. These components support the design and manufacture of primary power distribution panels and circuit breaker panels as well. The Safran Electrical & Power product portfolio includes: * Electro-mechanical thermal circuit breakers (0.5 to 300 amperes) - single phase or three phase thermally actuated devices offered in conventional design or with integrated Arc Fault Circuit Interrupt technology. * Remote Control Circuit Breakers (5 to 125 amperes) - single phase or three-phase devices sold separately or as a subsystem when combined with a necessary indicator control unit (0.5 ampere circuit breaker). * Electro-mechanical Remote Power Controllers (125 to 200 amperes) - single-phase devices sold separately or as a subsystem when combined with a necessary indicator control unit (0.5 ampere circuit breaker). * Smart Contactors with current sensing protection or Arc Fault Circuit Interrupt technology SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." CAPABILITIES * 28 VDC Contactors (50 to 1000 amperes) The SafranElectrical& Power Difference * 270 VDC Contactors (25 to 350 amperes) There are a number of circuit breaker suppliers in the aerospace market. However, none of them possess the vertical integration needed to engineer and manufacture both circuit breaker components and subsystems that include both primary power distribution panels and circuit breaker panels. * 115/230 VAC 400 Hz Contactors (30 to 430 amperes) * 750 VDC Contactors (100 to 600 amperes) * A variety of aerospace switches (rocker, toggle, pushbutton and limit). Safran Electrical & Power Capabilities * Proven excellence in component and subsystem design, development, test ing, qualification, and production for both military and commercial aerospace applications. * A manufacturing organization that emphasizes customer satisfaction by focusing on cost, quality, and delivery of the product portfolio. * Altitude / temperature test ing chambers simulating altitudes to 80,000 feet and temperatures from -85F to 257F (-65C to 125C). * Test capabilities of 115/200 VAC 400Hz to 3600 amps, 28 VDC to 10,000 amps, 270/350/475 VDC to 1,500 amps. * Environmental tests for Sand and Dust, Shock, and Vibration. Safran Electrical & Power affords its customers the following difference: Safran Electrical & Power's unique product portfolio, it's ability to design and manufacture components and subsystems, and customer centric strategy, mitigates the risk associated with new aircraft circuit protection systems. Safran Electrical & Power is an ideal candidate to consider for engineering and manufacturing collaboration on all future commercial, General Aviation, and military programs. * Strong brand recognition, customer loyalty, and demonstrated market presence for over 80 years. * Ability to leverage the company's size, financial strength, and scope to drive superior results. Safran Electrical & Power has the ability to leverage the engineering resources of a multi-billion dollar company. * An extensive product port folio that compliments integrated sub-system design competency. * A flat organizational structure that allows for the optimal blend of best value technical approach and test support within budget and schedule constraints. * Dedicated program managers that understand and communicate "voice of the customer". * Latest CAD/CAM finite element analysis, stereolitho-graphic techniques, and PRO E design. * Design software that promotes concurrent engineering and the exchange of customer data. * Model Shop flexibility to respond to design changes and the rapid turn around of prototypes. * Co-located engineering, manufacturing, and development resources promote robust product development and product support. "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 9 ARC FAULT CIRCUIT INTERRUPT The Aging Aircraft Dilemma Today, in the Unites States there are more than 22,000 civil and military aircraft in operation. Many are over 20 years old. To maintain airworthiness, many have been retrofitted with new engines, new avionics, improved hydraulic systems and even new interiors. However, one element in older aircraft that will not change is the miles and miles of electrical wiring buried within the aging airframe. Over time these wire bundles and their protective insulation can deteriorate, providing the perfect environment for an electrical short and a potential fire hazard. Until recently, aircraft circuit breakers were considered the first line of defense against electrical hazards. However, research has shown that arc faults, with temperatures as high as 6000C, can go completely undetected by circuit breakers developed over 30 years ago. The unfortunate roll call of recent aircraft accidents blamed on explosions or fires suspected to have been triggered by electrical wire arcing is familiar. And the potential for additional incidents may be even more sobering. Safety reports show numerous, nonfatal incidents of smoke in the cockpit and electrical faults attributed to wire arcing. Navy Statistics show 64 inflight electrical fires between July 1995 and December 1997. On the civil side, Federal Aviation Administration (FAA) data from 1989 through July 1998 show 622 reports of smoke in the cockpit or cabin. "No-Fault Design" By Rick DeMeis, Design News Sept 4, 2000. 10 Why Don't Aircraft Circuit Breakers Provide Protection from Arcing Faults? Aerospace circuit breakers are designed to protect wiring from thermal damage that occurs during an over-current situation. They are able to do this by deploying a bi-metallic element that mimics that thermal effect of current on a wire's insulation. The reason circuit breakers do not provide protection from arcing events is that they are not designed to. The characteristics of an arcing event include fault currents that are sporadic or sputtering, have values several times the breakers rating, and the arc event is of such a short duration that the circuit breaker has little time to react. Safran Electrical & Power's Arc-Fault Circuit Interrupt (AFCI) Technology - The Next Generation of Circuit Protection "Present commercial airplane circuit breakers do not detect and react to arcing faults associated with the chafing and subsequent intermittent arcing when bare wires contact metal airplane structure or other bare conductors..." FAA Aging Transport NonStructural Systems Plan, July 1998, page 17 Incorporating AFCI Into Thermal Protection Devices Safran Electrical & Power's AFCI protective device recognizes the unique signatures of arc-ing faults and acts to interrupt the circuit. Safran Electrical & Power's Arc-Fault Circuit Interrupt technology utilizes microelectronics to monitor and analyze a circuit's current waveform. This logic circuit utilizes algorithms developed over the last 10 years. These algorithms "look" directly for the randomness in the 400Hz current signal to determine if an arcing event has occurred. If the logic circuit determines an arc fault exists, a signal is sent to the circuit protection device, which will safely shut down the circuit in question. Recognizing An "Acceptable Arc" From An "Unacceptable Arc" Elimination of the "Nuisance" Trip Safran Electrical & Power's unique AFCI technology monitors the reaction of the current waveform to an arcing incident to ensure that the AFCI circuit-ry can discriminate between an unacceptable arc and an acceptable arc. An unacceptable arc would be any situation such as two wires or a wire to ground electrical arc due to exposed conductors. An acceptable arc could be the power surge in the starting of a hydraulic pump or another electrically driven, primary or auxiliary support component. In order to distinguish an acceptable arc from an unacceptable arc, sophisticated arc fault algorithms employ various statistical methods that are capable of identifying the degree of chaos or randomness in the current signal. This prevents the chance of nuisance tripping even in situations where the switching of devices involves in-rush transients resulting from motor or pump start-ups. Integrating the AFCI circuitry into the standard aerospace circuit breaker required the miniaturization of the present mechanism to make room for the necessary electronics and to provide a way to power the logic circuit. As a result of this effort, Safran Electrical & Power's AFCI circuit breaker has many added benefits: * Offer same size as current circuit breakers listed in MS24571 and MS14105. * Provides separate visible indication of an arc fault vs. over-current fault. * Include independent operation of the electromechanical portion of circuit breaker so that the circuit breaker remains operational even with an AFCI electronics failure. The AFCI technology can be packaged into a form / fit line replaceable unit (LRU) such as a thermal circuit breaker. Safran Electrical & Power's AFCI solution builds added safety into the LRU without the need to modify the existing electri-cal architecture of the aircraft. AFCI technology is easily tailored to an application or device. Safran Electrical & Power's product portfolio of thermal circuit breakers, relays, and Remote Control Circuit Breakers can provide the required arc fault protection to address every platform electrical protection requirement. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 160 COMPACT PROTECTION FOR HIGHER CURRENT RATINGS Standard Single-Pole High Performance P E R F O R M A N C E DATA Interrupting Capacity 6,000A at 30V, DC; 3,500A at 120V, 400 Hz., AC Endurance At 120VAC, 400 Hz.: inductive load -- 5,000 cycles; resistive load -- 5,000 cycles; at 30V, DC: inductive load -- 2,500 cycles; resistive load -- 5,000 cycles; mechanical cycling, no load -- 5,000 cycles Overload Cycling 100 operations at 200% rated current and rated voltage Dielectric Strength At sea level, 25C 1,500V, AC. At 70,000 ft., 71C 500V, AC Protects circuits from 50 to 100 amperes. Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop 0.15V, maximum Heavy-Duty Construction Vibration Meets specification MIL-STD-202, Method 204, Condition A-10G, 10-500 Hz. Breaker features large contacts and wide terminals. Shock Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Acceleration Exceeds 10G's Not Sensitive To Frequency Weight 113 grams (0.25 lbs.) Qualified To MIL-C-5809 and MS25361. Protection For Heavy-Duty Systems May be used on either AC or DC circuits. Performance Rated Circuit Breaker The 160 series has the recognition of being the most specified heavy-duty aircraft type circuit breaker in the 50 to 100 ampere rating range. Designed to protect heavy-duty aircraft and non-aircraft electrical systems, this trip-free breaker features separate, durable, overload and mechanical latches. In addition, the overload latch is designed for precise operation. Extra heavy contacts are springloaded to maintain high-contact pressure and assure long life. Contact material has high resistance to arcing and the corrosive action of moisture --thus assuring low voltage drop throughout the life of the breaker. OV E R LOA D C A L I B R AT I O N DATA @ 25C @ +71C @ -40C Test Time Specification Table MIN MAX MIN MAX MIN MAX Parameters Must Hold 105 -- 70 -- 125 -- % For 1 Hour Must Trip -- 138 -- 125 -- 165 % Within 1 Hour 200% Overload 15 65 -- -- -- -- Seconds 400% Overload 2 10 -- -- -- -- Seconds 600% Overload 1 4 -- -- -- -- Seconds Trip curve available O R D E R I N G I N F O R M AT I O N STANDARD MS APPROVAL STATUS AMPERE RATING VOLTAGE DROP MAX. * MS P/N SAFRAN MP P/N HIGH VIBRATION MS P/N SAFRAN MP P/N MS Approved 50 0.15 MS25361-50 160-012-50 MS25361-50V 160-086-50 MS Approved 60 0.15 MS25361-60 160-012-60 MS25361-60V 160-086-60 MS Approved 70 0.15 MS25361-70 160-012-70 MS25361-70V 160-086-70 MS Approved 75 0.15 MS25361-75 160-012-75 MS25361-75V 160-086-75 MS Approved 80 0.15 MS25361-80 160-012-80 MS25361-80V 160-086-80 MS Approved 90 0.15 MS25361-90 160-012-90 MS25361-90V 160-086-90 MS Approved 100 0.15 MS25361-100 160-012-100 MS25361-100V 160-086-100 * AT RATED NOMINAL CURRENT 3 Phase variants are available as a 940 Series. For other amperage ratings and configurations, consult the Business Unit. 12 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 160 DIMENSIONS RECOMMENDED MOUNTING .500 .005 DIA. #28 (.140) DIA. 2 PLACES 100 .750 MAX. .906 AMPERE RATING IN WHITE FIGURES .906 .005 .138-32UNC-2B INTEGRAL SELF LOCKING NUTS (2 REQUIRED) 1.812 .010 1.812 .410 DIA. MOUNTING PLATE .485 MIN. CLOSED .250 .750 TRIPPED BLACK ACTUATOR WHITE TRIP INDICATOR .330 DIA. BLACK SLEEVE .480 DIA. 1.580 MAX. 2.047 2.250 MAX. 45 .090 LINE TERMINAL .250-28UNF-2AX.500L CAP SCREW WITH FLAT WASHER MS35308-303 .735 1.470 2.189 MAX. LOCKING NUTS Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C 1000 138% 100 105% 0 0.1 1.0 10 100 Time To Open (Trip) In Seconds 1000 10000 "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 13 SERIES 170 PROTECTION FOR CURRENT RATINGS OF 125 TO 200 AMPERES Single-Pole High Performance Protection For Very High Current Rated Circuits P E R F O R M A N C E DATA Interrupting Capacity 3,000A at 28V, DC; 2,500A at 115V, AC Endurance At 120V, 400 Hz.: inductive load -- 2,500 cycles; resistive load -- 5,000 cycles; Protects circuits from 125 to 200 amperes. at 30V, DC: inductive load -- 1,000 cycles; resistive load -- 5,000 cycles; mechanical cyclin g, no load -- 5,000 cycles Meets MS Mounting Dimensions Overload Cycling 100 operations at 200% rated current and rated voltage Dielectric Strength 1,500V, minimum Has mounting dimensions compatible with Military Standard Drawing requirements of MS25017 of MIL-C-5809. Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop 0.1 volt maximum at rated current Vibration Exceeds MIL-STD-202, Method 204, Condition A Shock Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Acceleration Exceeds 10G's Weight 130 grams (0.286 lbs.) Heavy-Duty Components Extra heavy contacts and wide sturdy terminals. Trouble-Free Contact Life Contacts mounted on springloaded pivots to maintain highcontact pressure and to improve arc quenching capability. Performance Rated Circuit Breaker The 170 series is the only compact, reliable, heavy-duty aircrafttype circuit breaker available in the 125 to 200 ampere range.It is the only device in this range that has mounting dimensions compatible with Military Standard Drawing MS25017. Designed to protect heavy-duty aircraft electrical systems, the breaker features separate overload and mechanical latches. The unit's trip-free design prevents it from being held closed manually against any overload that would ordinarily cause it to open. The breaker may be used on either AC or DC circuits. OV E R LOA D C A L I B R AT I O N DATA Specification Table @ 25C MIN MAX @ +71C MIN MAX @ -40C MIN MAX Test Time Parameters Must Hold 100 -- 70 -- 110 -- % For 1 Hour Must Trip -- 125 -- 125 -- 160 % Within 1 Hour 200% Overload 15 70 -- -- -- -- Seconds 400% Overload 2 12 -- -- -- -- Seconds 600% Overload 1 5 -- -- -- -- Seconds O R D E R I N G I N F O R M AT I O N Ampere Rating Voltage Drop Max.* Part Number 125 .100 170-001-125 140 .100 170-001-140 150 .100 170-001-150 160 .100 170-001-160 180 .100 170-001-180 200 .100 170-001-200 * At rated nominal current. Three phase variants are available as a 970 Series. Also available as a 180 Series device for ratings up to 300 amperes. For other amperage ratings and configurations, consult the Business Unit. 14 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 170 DIMENSIONS RECOMMENDED MOUNTING .500 .005 DIA. .140 DIA. 2 PLACES AMPERE RATING IN WHITE FIGURES 200 1.000 MAX. .906 .005 2 #6-32 INTEGRAL SELF LOCKING NUTS .906 1.812 1.812 .010 .410 DIA. .250 CLOSED MOUNTING PLATE .250 .460 TRIPPED LACK ACTUATOR WHITE TRIP INDICATOR .330 DIA. LACK SLEE E .480 DIA. T PE 1.570 MAX. 2.047 2.250 MAX. 45 .093 LINE TERMINAL .719 1.438 2.189 MAX. 2-1/4-28 X 1/2 HEX. HEAD SCREW AND FLAT WASHER 1/4-28 SELF LOCKING NUTS Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C 1000 125% 100 100% 0 0.1 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 15 SERIES 700 A MINIATURE BREAKER WITH HIGH INTERRUPTING CAPACITY High/Random Vibration (Flush Mounting) Standard (Bushing Mounting) Single-Pole High Performance P E R F O R M A N C E DATA Interrupting Capacity 6,000A at 30V, DC. 3,500A at 120V, 400 Hz., AC Endurance At 120V, 400 Hz., AC or 30V, DC: inductive load -- 2,500 cycles; resistive load -- 5,000 cycles; mechanical cycling, no load -- 5,000 cycles Overload Cycling 100 operations at 200% rated current and rated voltage Dielectric Strength At sea level, 25C 1,500V, AC. At 65,000 ft., 70C 500V, AC. 1,500V, minimum Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop Varies with rating (see "Ordering Information") Vibration Exceeds MIL-STD-202, Method 204, Condition A (Random Optional) Circuit breaker weighs only 43 grams. Shock Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Acceleration Exceeds 10G's High Interrupting Capacity Weight 700-001: 43 grams (.1 lbs.). 700-089: 48 grams (.11 lbs.) Altitude Maximum 65,000 ft. Qualified To MS25244, MS25244-P and MS25244-PT of MIL-C-5809 (MS25244PT is a substitute for MS25017) . Lightweight Interrupts a 6,000A circuit at 30V, DC; 3,500A circuit at 120V, 400 Hz. AC. Performance Rated Circuit Breaker Exceeds military specification requirements for durability, vibration, mechanical shock, and acceleration.The 700 is a miniature push-pull breaker offering fast trip and high interrupting capacity. Its trip-free design prevents the breaker from being held closed manually on overloads. A feature of the breaker is separate overload and mechanical latches. Separated in this way, the mechanical latch assures maximum endurance for the thousands of cycles of manual on-off operation, while the thermal latch combines both precise operation and durability. Bushing and Flush Mounting Options 16 OV E R LOA D C A L I B R AT I O N DATA @ 25C @ +71C 0.5 - 7 1/2A Specification @ -40C 10 - 50A 0.5 - 7 1/2A 10 - 50A Table MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX Test Time Parameters Must Hold 115 -- 60 -- 70 -- 156 -- 148 -- % For 1 Hour Must Trip -- 138 -- 108 -- 114 -- 178 -- 178 % Within 1 Hour 200% Overload 15 55.0 -- -- -- -- -- -- -- -- Seconds 400% Overload 2 7.0 -- -- -- -- -- -- -- -- Seconds 600% Overload 1 3.5 -- -- -- -- -- -- -- -- Seconds Trip curve available. O R D E R I N G I N F O R M AT I O N ADAPTER FLUSH MOUNTING PLATE STANDARD BASE & TERMINAL CONFIGURATION STYLE "P" ALTERNATE BASE & TERMINAL CONFIGURATION STYLE "PT" MS APPROVAL STATUS AMPERE RATING VOLTAGE DROP MAX. * MS P/N SAFRAN MP P/N MS P/N SAFRAN MP P/N MS P/N SAFRAN MP P/N MS Approved 5 0.25 MS25244-5 700-001-5 MS25244-P5 700-089-5 MS25244-PT5 700-092-5 MS Approved 7 1/2 0.25 MS25244-7 1/2 700-001-705 MS25244-P7 1/2 700-089-705 MS25244-PT7 1/2 700-092-705 MS Approved 10 0.25 MS25244-10 700-001-10 MS25244-P10 700-089-10 MS25244-PT10 700-092-10 MS Approved 15 0.25 MS25244-15 700-001-15 MS25244-P15 700-089-15 MS25244-PT15 700-092-15 MS Approved 20 0.25 MS25244-20 700-001-20 MS25244-P20 700-089-20 MS25244-PT20 700-092-20 MS Approved 25 0.25 MS25244-25 700-001-25 MS25244-P25 700-089-25 MS25244-PT25 700-092-25 MS Approved 30 0.25 MS25244-30 700-001-30 MS25244-P30 700-089-30 MS25244-PT30 700-092-30 MS Approved 35 0.25 MS25244-35 700-001-35 MS25244-P35 700-089-35 MS25244-PT35 700-092-35 Non MS Approved 40 0.25 700-001-40 700-089-40 700-092-40 Non MS Approved 50 0.25 700-001-50 700-089-50 700-092-50 * AT RATED NOMINAL CURRENT Three phase variants are available as a 930 Series. ForTF300-1E other amperage ratings and configurations, consult the Business Unit. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 700 700-089 (MS25244-P) DIMENSIONS Dimensions Different Base & Terminal RECOMMENDED MOUNTING MS-25244 .750 MAX. .375 .005 MOUNTING NUT MS25082-C21 MOUNTING LOCKWASHER MS35333-136 LOCATING LUG .470 MIN. CLOSED .045 45 LINE TERMINAL BLACK ACTUATOR WHITE TRIP INDICATOR .750 MAX. TRIPPED .469-32UNS-2A THREAD BUSHING .352 .704 1.094 MAX. .468 .906 .005 .100 .015 .330 DIA. .410 DIA. BLACK ACTUATOR WHITE TRIP INDICATOR .719 MAX. .375 MIN. .156 .015 .250 .015 45 2 2 SCREWS #8-32 MS5197-41 & LOCKWASHER MS35338-137 RECOMMENDED MOUNTING MS-25244-P & MS-25244-PT .500 .005 DIA. .140 DIA. 2 PLACES 1.812 .010 MS25244-P Base & Terminal 1.490 MAX. 1.707 1.860 MAX. .250 .330 DIA. 6-32 SELF LOCKING NUTS .906 .008 1.812 .016 MAX. PANEL THICKNESS .100 .410 DIA. RATING ON BUTTON IN WHITE FIGURES 1.530 MAX. 1.665 MAX. 1.747 2.000 MAX. 5 .750 MAX. .375 .005 TO CLOF LUG AMPERE RATING IN WHITE FIGURES 1.093 .484 .005 DIA. .125 .005 DIA. .093 .005 DIA. 2.189 MAX. 35 700-001 (MS25244) 700-092 (MS25244-PT) .062 .001 .352 .704 1.094 MAX. BLACK FINISH 2 SCREWS #8-32 MS5197-41 & LOCKWASHER MS35338-137 .344 .750 MAX. MS25244-PT Base & Terminal .410.015 DIA. .330.015 DIA. .468 .100.015 .250.015 .375 MIN. 1.812 2.000 MAX. 45 REF. .177 MIN. .594 1.188 TRIP CURVE Screw (2 - Required) (MS 51957-41) Lockwasher (MS35338-137) 1.66 MAX. Percentage Of Circuit Breaker's Rated Current 10000 TYPICAL TRIP CURVE AT 25C RANGE AT 25C UPPER LIMIT AT 40. REFERENCE ONLY 1000 178% 138% 115% 70% 100 LOWER LIMIT AT 71C. REFERENCE ONLY 0 0.1 1.0 1000 10 100 Time To Open (Trip) In Seconds 10000 "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 17 SERIES 1500 Single-Pole High Performance FAST TRIP PROTECTION FOR LOW-CURRENT EQUIPMENT P E R F O R M A N C E DATA Interrupting Capacity 1/2 to 1A: 600A at 120V AC, 400 Hz.; 6,000A at 30V DC 1 1/2 to 4A: 1,000A at 120V AC 400 Hz.; 6,000A at 30V DC 5 to 10A: 600A at 120V AC 400 Hz.; 6,000A at 30V DC Endurance At 120VAC, 400 Hz., or at 30V DC; inductive load -- 2,500 cycles; resistive load -- Qualified Designed to MS22074 for MIL-C5809. Fast Trip 5,000 cycles; mechanical cycling, no load -- 5,000 cycles Overload Cycling 100 operations at 200% rated current and rated voltage Dielectric Strength 1,500V, minimum Insulation Resistance Not less than 100 megohms at 500V, DC Fail-Safe Operation Voltage Drop Varies with rating (see "Ordering Information") Fault cannot cause breaker to fuse closed. Vibration Exceeds MIL-STD-202, Method 204, Condition A Shock Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Ambient-Compensated Acceleration Exceeds 10G's No appreciable change in trip time from -40C to +71C. Weight 45 grams (.099 lbs.) Operates on a hot-wire principle, much faster than bimetal breakers. Low Resistance Silver alloy contacts maintain low resistance for life of circuit breaker. OV E R LOA D C A L I B R AT I O N DATA @ 25C Load Protection The fast tripping circuit breaker is ideal for protecting sensitive loads such as avionics and fuel pumps where rapid detection and fault clearing are desired. Specification Performance Rated Circuit Breaker It is the only thermal hot wire type available in ratings from one-half ampere. The 1500 is a circuit breaker that features fast trip for quick response. Designed for the protection of both wiring and equipment, the unit provides trip indication, trip-free protection, and the convenience of manual onoff operation. Excellent temperature stability is assured by the hot-wire design. The breaker has a high resistance to shock and vibration. Its "Fail Safe" design eliminates the danger of the breaker fusing closed on overload. 0.5 - 3A @ +71C 4.5 - 10A Test Time Table MIN MAX MIN MAX MIN MAX MIN MAX Parameters Must Hold 115 -- 115 -- 115 -- 115 -- % For 1 Hour Must Trip -- 138 -- 138 -- 138 -- 138 % Within 1 Hour 200% Overload .400 3.0 .800 3.60 -- -- -- -- Seconds 400% Overload .090 0.6 .140 0.75 -- -- -- -- Seconds 600% Overload .042 0.3 .055 0.35 -- -- -- -- Seconds Trip curve available O R D E R I N G I N F O R M AT I O N Ampere Rating Voltage Drop Max.* Part Number 1/2 1.21 1500-052-05 3/4 1.21 1500-052-075 1 1.20 1500-052-1 1 1/2 1.10 1500-052-105 2 0.95 1500-052-2 2 1/2 0.85 1500-052-205 3 0.81 1500-052-3 ICU Application 4 0.72 1500-052-4 This circuit breaker meets the requirements of MIL-C-83383 for use as a RCCB ICU (Indicator Control Unit). Its I2t function is per specification. 5 0.65 1500-052-5 10 0.55 1500-052-10 18 @ -40C * At rated nominal current. For other amperage ratings and configurations, consult the Business Unit. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 1500 DIMENSIONS RECOMMENDED MOUNTING LOCATING PIN .093 DIA. .484 .005 DIA. 1 2 .125 .005 DIA. .750 MAX. .375 .005 .375 .005 TO CL OF PIN AMPHERE RATING IN WHITE FIGURES .410 DIA. MOUNTING NUT MS25082-B21 MOUNTING LOCKWASHER MS35333-126B .470 MIN. .750 MAX. BLACK ACTUATOR WHITE TRIP INDICATOR .4687-32UN-2A THREAD .045 1.453 1.660 1.843 MAX. .250 .330 DIA. 45 .350 .700 LINE TERMINAL 1.137 2 SCREWS #8-32 MS35206-241 & LOCKWASHERS MS35338-42 Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C UPPER RANGE 4.5 - 10 AMPS LOWER RANGE 0.5 - 3 AMPS 1000 138% 100 0 0.01 115% 0.1 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 19 SERIES 4001 SUB-MINIATURE PRECISION CIRCUIT BREAKER Single-Pole High Performance P E R F O R M A N C E DATA Interrupting Capacity To MS22073 of MIL-C-5809 Lightweight Under 33 grams (.073 lbs) High Interrupting Capacity Interrupts up to 6,000A circuit at 30V, DC; and up to 3,500A circuit at 120V, 400 Hz. AC. Not Sensitive To Frequency Or Voltage Breaker may be used on either AC or DC circuits. Performance Rated Circuit Breaker Meets or exceeds military specification requirements for durability, vibration, mechanical shock, and acceleration.Precision internal design provides a time-temperature characteristic capable of protecting either wire or equipment. With a case 1 1/2 inches long, the breaker weighs less than 33 grams, and is ideal for today's demanding design requirements. 1 to 5A: 6,000A at 30V, DC. 7 1/2 to 25A: 2,000A at 30V, DC 1A: 3,500A at 120V, 400 Hz., AC. 2 to 5A: 800A at 120V, 400 Hz., AC 7 1/2 to 25A: 500A at 120V, 400 Hz., AC Qualified Endurance * At 120V, 400 Hz., AC, or 28V, DC: inductive load -- 2,500 cycles; resistive load -- 5,000 cycles; mechanical cycling, no load -- 5,500 cycles Overload Cycling 100 operations at 200% rated current and rated voltage Dielectric Strength 1,500V, minimum Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop Varies with rating (see "Ordering Information") Vibration* Meets specification MIL-STD-202, Method 204, Condition A, 10G, 10-500 Hz. MS "V" type (4001-008) meets Condition B, 15G, 10-2,000 Hz. and Condition C, 10G, 10-2,000 Hz. MS "D" type (4001-011) meets Random Vibration levels Shock * Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Acceleration Exceeds 10G's Weight 33 grams (0.073 lbs.) * Variations of these circuit breakers are capable of exceeding the standard Mil specification for endurance, vibration, and shock. Consult the business unit for more information. OV E R LOA D C A L I B R AT I O N DATA Specification Table @ 25C MIN @ +71C MAX MIN MAX @ -55C MIN MAX Test Time Parameters Must Hold 115 -- 90 -- 135 -- % For 1 Hour Must Trip -- 150 -- 130 -- 180 % Within 1 Hour 200% Overload 2.000 20.0 -- -- -- -- Seconds 500% Overload 0.160 2.0 -- -- -- -- Seconds 1000% Overload 0.046 0.5 -- -- -- -- Seconds Trip curve available 20 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 4001 .780 MAX. Ampere Rating In White Figures 3 DIMENSIONS .593 MAX. .375 .005 .125 .005 DIA. .484 .005 DIA. .410 DIA. Mounting Lockwasher MS35333-136B Mounting Nut MS25082-C21 .469-32UNS-2A Threaded Bushings .467 MIN. Closed .750 MAX. Tripped .250 1.852 MAX. 1.707 1.535 MAX. 45 .352 .703 2 Screws MS51957-41 & Lockwashers MS35338-137 Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C 1000 150% 100 0 0.01 115% 0.1 10 1.0 100 Time To Open (Trip) In Seconds 1000 10000 "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 21 SERIES 4200 HIGH PERFORMANCE LIGHTWEIGHT SUB-MINIATURE CIRCUIT BREAKER Longbutton Standard Single-Pole High Performance Auxiliary Terminal PERFORMANCE DATA Interrupting Capacity 1 1 2 7 Endurance * At 120V, 400 Hz., AC or at 28V, DC: inductive load -- 2,500 cycles; resistive load -- 5,000 cycles; mechanical cycling, no load -- 5,000 cycles High Interrupting Capacity Overload Cycling Minimum of 100 cycles at 200% rated current High Vibration and Shock Resistance Dielectric Strength At sea level, 25C 1,500V, AC. At 80,000 ft. 71C 500V, AC Insulation Resistance Not less than 100 megohms at 500V, DC Sub-Miniature Size Voltage Drop Varies with rating (see "Ordering Information") Performance Rated Circuit Breaker Vibration* Meets specification MIL-STD-202, Method 204, Condition A 10-57 Hz. 06 in. Displacement Double Amplitude, and 57-500 Hz. at 10G's (Random vibration level also available) Shock* Exceeds 50G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213A Test A Acceleration Exceeds 10G's Weight 22 grams (0.048 lbs.) Qualified To MS26574 of MIL-C-5809 Lightweight 22 grams (.048 lbs) The 4200 is a sub-miniature, lightweight, trip free, single phase circuit breaker, which combines its compact size with a proven technological track record. A modification of the popular 4310 series, its reliability has been long established. Options such as long button, high vibration resistance, and hardware variations will enhance its versatility. The 4200 reacts consistently in extreme fluctuations of temperature, high shock, vibration, or humidity. Auxiliary Switch And Terminals The 4200 Series is also available in an Auxiliary Switch version (4200-004) to provide a remote indication of a trip condition. In a trip condition, the contacts in the auxiliary switch are in a closed position. to 5A: unlimited at 28V DC; 7 1/2 to 25A: 2,000A at 28V DC to 1 1/2A: unlimited at 120V 400 Hz., AC to 5A: 800A at 120V, 400 Hz., AC 1/2 to 25A: 500 amps at 120V, 400 Hz., AC * Variations of these circuit breakers are capable of exceeding the standard Mil specification for endurance, vibration, and shock. Consult the business unit for more information. OVERLOAD CALIBRATION DATA @ 25C Specification Table MIN @ +71C MAX MIN MAX @ -55C MIN MAX Test Time Parameters Must Hold 115 -- 90 -- 135 -- % For 1 Hour Must Trip -- 150 -- 130 -- 180 % Within 1 Hour 200% Overload 2.000 20.0 -- -- -- -- Seconds 500% Overload 0.160 1.2 -- -- -- -- Seconds 1000% Overload 0.046 0.8 -- -- -- -- Seconds Trip curve available. ORDERING INFORMATION LONG BUTTON STANDARD MS APPROVAL AMPERE STATUS RATING VOLTAGE DROP MAX. * MS P/N SAFRAN MP P/N MS P/N SAFRAN MP P/N RANDOM VIBRATION MS P/N SAFRAN MP P/N AUXILIARY TERMINAL MS P/N SAFRAN MP P/N LONG BUTTON MS P/N SAFRAN MP P/N MS Approved 3/4 1.45 MS26574-3/4 4200-001-075 MS26574-3/4L 4200-003-075 MS26574-D3/4 4200-006-075 MS26574-3/4A 4200-004-075 MS26574-D3/4L 4200-007-075 MS Approved 1 1.10 MS26574-1 4200-001-1 MS26574-1L 4200-003-1 MS26574-D1 4200-00 6-1 MS26574-1A 4200-004-1 MS26574-D1L 4200-007-1 MS Approved 1 1/2 0.75 MS26574-1 1/2 4200-001-105 MS26574-1 1/2L 4200-003-105 MS26574-D1 I/2 4200-006-105 MS26574-1 1/2A 4200-004-105 MS26574-D1 1/2L 4200-007-105 MS Approved 2 0.75 MS26574-2 MS26574-2L 4200-003-2 MS26574-D2 4200-006-2 MS26574-2A MS26574-D2L MS Approved 2 1/2 0.70 MS26574-2 1/2 4200-001-205 MS26574-2 1/2L 4200-003-205 MS26574-D2 1/2 4200-006-205 4200-001-2 4200-004-2 MS26574-2 1/2A 4200-004-205 4200-007-2 MS26574-D2 1/2L 4200-007-205 MS Approved 3 0.55 MS26574-3 4200-001-3 MS26574-3L 4200-003-3 MS26574-D3 4200-006-3 MS26574-3A 4200-004-3 MS26574-D3L 4200-007-3 MS Approved 4 0.45 MS26574-4 4200-001-4 MS26574-4L 4200-003-4 MS26574-D4 4200-006-4 MS26574-4A 4200-004-4 MS26574-D4L 4200-007-4 MS Approved 5 0.35 MS26574-5 4200-001-5 MS26574-5L 4200-003-5 MS26574-D5 4200-006-5 MS26574-5A 4200-004-5 MS26574-D5L 4200-007-5 MS Approved 7 1/2 0.30 MS26574-7 1/2 4200-001-705 MS26574-7 1/2L 4200-003-705 MS26574-D7 1/2 4200-006-705 MS26574-7 1/2A 4200-004-705 MS26574-D7 1/2L 4200-007-705 MS Approved 10 0.28 MS26574-10 4200-001-10 MS26574-10L 4200-003-10 MS26574-D10 4200-006-10 MS26574-10A 4200-004-10 MS26574-D10L 4200-007-10 MS Approved 15 0.25 MS26574-15 4200-001-15 MS26574-15L 4200-003-15 MS26574-D15 4200-006-15 MS26574-15A 4200-004-15 MS26574-D15L 4200-007-15 MS26574-20 4200-001-20 MS26574-20L 4200-003-20 MS26574-D20 4200-006-20 MS26574-20A 4200-004-20 MS26574-D20L MS Approved 20 0.25 Non MS Approved 25 0.20 4200-001-25 4200-003-25 4200-006-25 4200-004-25 4200-007-20 4200-007-25 * AT RATED NOMINAL CURRENT For other amperage ratings and configurations, consult the Business Unit. 22 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 4200 DIMENSIONS Part No. A*Max. B*Min. 4200-001 0.759 0.407 4200-003 1.134 0.782 4200-004 0.759 0.407 4200-006 0.759 0.407 4200-007 10134 0.782 RECOMMENDED MOUNTING .780 MAX. .375 .005 AUXILIARY SWITCH OPERATION CLOSED LINE LOAD .453 .005 DIA. AUXILIARY CIRCUIT 5 Min. Panel Thickness .025 Max. Panel Thickness .100 OPEN .125 .005 DIA. LINE .398 .015 DIA. .045 .010 - .005 LOAD AUXILIARY CIRCUIT MOUNTING UNIT MS25062-C18 LOCKWASHER MS3533-141B .4375-32UN-2B THREAD BUSHING A* B* OPEN CLOSED 1.251 MAX. AUXILIARY TERMINAL 1.404 1.525 MAX. LOCKWASHER MS36336-136 TERMINAL SCREW MS51957-25 .593 MAX. AUXILIARY TERMINAL MODEL ONLY .593 MAX. .593 AUXILIARY TERMINAL Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C RANGE AT 25C UPPER LIMIT AT -55C. REFERENCE ONLY 1000 180% 150% 115% 90% 100 LOWER LIMIT AT 71C. REFERENCE ONLY 0 0.01 0.1 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 23 SERIES 4310 AMBIENT TEMPERATURE-COMPENSATED SUB-MINIATURE CIRCUIT BREAKER Standard Sub-Miniature Size -- High Performance PERFORMANCE DATA Interrupting Capacity* To MS3320 of Mil-C-5809. Meets performance specification of MS14105 of MIL-C-5809 1 to 25A: 6,000A at 28V, DC. 1A: 3,500A at 120V, 400 Hz., AC 1 1/2 to 2 1/2A: 2,800A at 120V, 400 Hz., AC; 3 TO 15: 2,500A AT 120V, 400 Hz., AC; 20 to 25A: 2,000A at 120V, 400 Hz., AC Endurance * At 120V, 400 Hz., AC or at 28V, DC: inductive load -- 2,500 cycles; resistive load -- 5,000 cycles; High Interrupting Capacity Overload Cycling Minimum of 100 cycles at 200% rated current Interrupts 6,000A fault at 28V, DC; up to 3,500A fault at 120V, 400 Hz., AC (ampere rating dependent). Dielectric Strength At sea level, 25C 1,500V, AC. At 70,000 ft. 121C 500V, AC Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop Varies with rating (see "Ordering Information") Vibration Resistance Vibration* Meets specification MIL-STD-202, Method 204, Condition A-10G, 10-500 Hz. Qualified Vibration resistance and mechanical life exceed MIL Specs -- including random vibration. Temperature-Compensated mechanical cycling, no load -- 10,000 cycles MS "V" type,(4310-019) meets Condition B, 15G, 10-2,000 Hz. and Condition C 10G, 10-2,000 Hz. Shock* Exceeds 50G's, 11 Milli-sec (half-sine pulse) MIL-STD-202, Method 213 Test A Acceleration Exceeds 10G's Weight 25 grams (.055 lbs.) Ambient-temperaturecompensated from -55C to +121C. * Variations of these circuit breakers are capable of exceeding the standard Mil specification for endurance vibration, shock, and Interrupting capacity. Consult the Business Unit for more information. Performance Rated Circuit Breaker OVERLOAD CALIBRATION DATA The lightweight, single-phase circuit breaker, Series 4310, allows high density packaging for all aircraft and aerospace needs. The 4310 series reflects the latest advancements in circuit breaker design -- plus other proven features (e.g., self-wiping contacts). Tight tolerances in design and stringent manufacturing standards are key factors in the reliable operation of the 4310 under severe environmental conditions of high temperature, high humidity, extreme vibration, and shock. It is also fungus- and corrosion-proof. @ 25C @ +121C @ -55C Specification Table MIN MAX MIN MAX MIN MAX Test Time Parameters Must Hold 115 -- 100 -- 115 -- % For 1 Hour Must Trip -- 138 -- 138 -- 160 % Within 1 Hour 200% Overload 5.00 20.00 1.500 13.00 7.00 40.00 Seconds 500% Overload 0.50 2.00 0.150 1.10 0.50 3.00 Seconds 1000% Overload 0.12 0.53 0.035 0.30 0.16 0.80 Seconds Trip curves available. ORDERING INFORMATION LONG BUTTON STANDARD HIGH VIBRATION MS Approval Status AMPERE RATING VOLTAGE DROP MAX. * MS P/N SAFRAN MP P/N MS P/N MS Approved 1 1.10 4310-001-1 MS3320-1L Non MS Approved 1 1/2 0.80 MS Approved 2 0.75 MS3320-2 MS Approved 2 1/2 0.70 MS3320-2-1/2 4310-001-205 MS3320-2 1/2L 4310--005-205 MS3320-2 1/2V 4310-019-205 MS3320-2 1/2VL 4310-024-205 MS Approved 3 0.55 MS3320-3 4310-001-3 MS3320-3L 4310-005-3 MS3320-3V 4310-019-3 MS3320-3VL 4310-024-3 MS Approved 4 0.45 MS3320-4 4310-001-4 MS3320-4L 4310-005-4 MS3320-4V 4310-019-4 MS3320-4VL 4310-024-4 Multiple Options MS Approved 5 0.35 MS3320-5 4310-001-5 MS3320-5L 4310-005-5 MS3320-5V 4310-019-5 MS3320-5VL 4310-024-5 This series is available in many optional configurations. MS Approved 7 1/2 0.30 MS3320-7-1/2 4310-001-705 MS3320-7 1/2L 4310-005-705 MS3320-7 1/2V 4310-019-705 MS3320-7 1/2VL 4310-024-705 MS Approved 10 0.28 MS3320-10 4310-001-10 MS3320-10L 4310-005-10 MS3320-10V 4310-019-10 MS3320-10VL 4310-024-10 It is presently being manufactured with 7/16, 15/32 and metric mounting sleeves. Many versions of different terminals, barriers, and hardware are current production items. Several different actuator options provide our customers with additional flexibility. MS Approved 15 0.25 MS3320-15 4310-001-15 MS3320-15L 4310-005-15 MS3320-15V 4310-019-15 MS3320-15VL 4310-024-15 MS Approved 20 0.25 MS3320-20 4310-001-20 MS3320-20L 4310-005-20 MS3320-20V 4310-019-20 MS3320-20VL 4310-024-20 Non MS Approved 25 0.20 Calibration integrity is maintained through wide variations in ambient temperature and altitude, making this circuit breaker ideal for applications where temperature is not controlled. 24 MS3320-1 4310-001-25 MS P/N 4310-005-1 MS3320-1V 4310-005-105 4310-001-105 4310-001-2 SAFRAN MP P/N LONG BUTTON VIBRATION MS3320-2L 4310-005-2 4310-005-25 SAFRAN MP P/N MS P/N 4310-019-1 MS3320-1VL 4310-019-105 MS3320-2V 4310-019-2 4310-019-25 SAFRAN MP P/N 4310-024-1 4310-024-105 MS3320-2VL 4310-024-2 4310-024-25 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 4310 DIMENSIONS Part No. A*Max. B*Min. MS3320 4310-001 0.750 0.470 MS3320L 4310-005 1.125 0.845 MS3320V 4310-019 0.750 0.470 MS3320VL 4310-024 1.125 0.845 RECOMMENDED MOUNTING .781 MAX. .125 .005 DIA. .453 .005 DIA. 5 MIL Spec .375 .005 .375 .010 Min. Panel Thickness .025 Max. Panel Thickness .100 BLACK BUTTON WHITE TRIP INDICATOR .4375-32UN-ZA THREAD .395 .005 DIA. .045 .010 .005 MOUNTING NUT MS25082-C18 A* B* MOUNTING LOCKWASHER MS35333-141 1.030 MAX. 1.218 1.343 MAX. LOCKWASHER MS35338-137 SCREW MS51957-41 .500 .593 Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C RANGE AT 25C 1000 UPPER LIMIT AT -55C. REFERENCE ONLY 160% 138% 100 115% 100% LOWER LIMIT AT +121C. REFERENCE ONLY 0 0.01 0.1 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 25 SERIES 940 THREE-PHASE, HIGH CAPACITY PROTECTION Heavy-Duty Three-Pole High Performance PERFORMANCE DATA Interrupting Capacity 1,200A at 120V 400 Hz., AC Endurance At 120VAC, 400 Hz.: inductive load -- 5,000 cycles; resistive load -- 5,000 cycles; mechanical cycling, no load -- 5,000 cycles Interphase Insulation Overload Cycling 100 cycles minimum at 200% rated current and rated voltage Insulating interphase barriers separate adjacent terminals. Dielectric Strength 1,500V, minimum Insulation Resistance Not less than 100 megohms at 500V, DC Common Trip Bar Voltage Drop Varies with rating (see "Ordering Information") One bar connects the three operating mechanisms for simultaneous trip action. Trip bar is removable for installation. Vibration Exceeds MIL-STD-202, Method 204, Condition A except, 7G peak Shock Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Acceleration Exceeds 10G's Weight 390 grams (.860 lbs.) Three-phase protection of circuits from 50 to 100 amperes. Performance Rated Circuit Breaker The 940 series is the only threepole heavy-duty aircraft-type circuit breaker available in the 50 to 100 ampere range and consists of three specially built 160-012 breakers with insulating interphase barriers separating adjacent terminals. The unit has a common trip bar connecting the three operating mechanisms so that an overload tripping one pole will simultaneously trip the remaining two poles. OVERLOAD CALIBRATION DATA Specification Table @ 25C MIN MAX @ +71C MIN MAX @ -40C MIN MAX Test Time Parameters Must Hold 105 -- 70 -- 145 -- % For 1 Hour Must Trip -- 138 -- 115 -- 170 % Within 1 Hour 200% Overload 15 70 -- -- -- -- Seconds 400% Overload 2 10 -- -- -- -- Seconds 600% Overload 1 4 -- -- -- -- Seconds Tip curve available. ORDERING INFORMATION Ampere Rating Voltage Drop Max.* 50 0.15 Part Number 940-006-50 60 0.15 940-006-60 70 0.15 940-006-70 75 0.15 940-006-75 940-006-80 80 0.15 90 0.15 940-006-90 100 0.15 940-006-100 * At rated nominal current. Data depicted is for the 940 Series. Also available to order are 920, 930, 960, and 970 Series devices. For other amperage ratings and configurations, consult the Business Unit. 26 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 940 DIMENSIONS RECOMMENDED MOUNTING .500 DIA. 3 PLACES 1.812 .906 .140 DIA. 6 PLACES TRI R REMO E OR IN T TION 2.631 MAX. .875 .015 6 6-32 INTEGRAL SELF LOCKING NUTS .875 .015 1.812 .015 AMPERE RATING IN WHITE FIGURES .906 .015 TRI R REMO E OR IN T TION .750 .384 CLOSED 3.48 SCREWS AND NUTS 1.546 .875 .291 MOUNTING PLATE .250 .875 .604 TRIPPED LACK ACTUATOR WHITE TRIP INDICATOR .330 DIA. LACK SLEE E .480 DIA. T PE LINE TERMINAL 2.046 2.437 45 6-1/4-28 X 1/2 HEX. HEAD SCREW AND FLAT WASHER 1/4-28 SELF LOCKING NUTS .718 1.437 .093 2.187 MAX. TRIP CURVE Percentage Of Circuit Breaker's Rated Current 10000 TYPICAL TRIP CURVE AT 25C 1000 138% 100 0 0.1 105% 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 27 SERIES 1526 FAST TRIP PROTECTION FOR DELICATE EQUIPMENT Three-Pole High Performance Common trip mechanism trips all three phases, regardless of which phase is overloaded. Low-Current Protection Protects circuits in ratings from 1 to 15 amperes. Ambient-Compensated Effects of temperature on trip times are minimal. Fast Trip PERFORMANCE DATA Interrupting Capacity 300A at 120V, 400Hz., AC, three-phase Endurance 4,000 cycles at 100% load Overload Cycling 100 cycles minimum at 200% load Dielectric Strength 1,500V, minimum Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop Varies with rating (see "Ordering Information") Vibration Exceeds MIL-STD-202, Method 204, Condition A Shock Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Acceleration Exceeds 10G's Weight 154 grams (.340 lbs.) Operates on a hot-wire principle, much faster than bimetal breakers. Low Resistance Contacts are made from a silver alloy that maintains low resistance throughout the life of the breaker. OVERLOAD CALIBRATION DATA @ 25C 1- 7.5A Specification @ +71C @ -65C 10 - 15A Test Time Table MIN MAX MIN MAX MIN MAX MIN MAX Parameters Load Protection Must Hold 115 -- 115 -- 110 -- 110 -- % For 1 Hour The fast tripping circuit breaker is ideal for protecting sensitive loads such as avionics and fuel pumps where rapid detection and fault clearing are desired. Must Trip -- 138 -- 138 -- 138 -- 138 % Within 1 Hour 200% Overload .35 4.0 3.0 10.0 -- -- -- -- Seconds 400% Overload .10 0.7 0.6 1.4 -- -- -- -- Seconds 600% Overload .04 0.3 0.3 0.8 -- -- -- -- Seconds Performance Rated Circuit Breaker Trip curve available. The 1526 Series is the only hot wire, fast-trip, three-pole circuit breaker in ratings from 1 -15 amperes. A single actuator controls all three poles, so that the breaker can be easily operated manually. There is only one overload latch; thus an overload on one pole will open all three poles simultaneously, regardless of which pole is overloaded. Long contact life is assured through the use of a low-resistance silver alloy. ORDERING INFORMATION Ampere Rating Voltage Drop Max.* Part Number 1 1.20 1526-005-1 1 1/2 1.20 1526-005-105 2 0.95 1526-005-2 2 1/2 0.85 1526-005-205 3 0.85 1526-005-3 3 1/2 0.75 1526-005-305 4 0.72 1526-005-4 5 0.65 1526-005-5 7 1/2 0.60 1526-005-705 10 0.55 1526-005-10 15 0.50 1526-005-15 * At rated nominal current. For other amperage ratings and configurations, consult the Business Unit. 28 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 1526 DIMENSIONS RECOMMENDED MOUNTING LOCATING PIN .093 DIA. .125 .005 DIA. .484 .005 DIA. .375 .005 .375 .005 TO CL OF PIN 1.300 MAX. 5 MAX. PANEL THICKNESS .100 AMPERE RATING IN WHITE FIGURES .410 DIA. .330 DIA. MOUNTING NUT MS25082-8 MOUNTING LOCKWASHER MS35333-126 .470 MIN. .750 MAX. .250 BLACK ACTUATOR WHITE TRIP INDICATOR .4687-32UN-2A THREAD 1.875 MAX. 1.500 REF. .045 LINE TERMINALS #6-FLAT WASHERS .688 .375 #6-LOCKWASHERS 1.376 #8-32 NUTS .750 2.063 Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C LOWER RANGE 1 - 71/2 AMP UPPER RANGE 10-15 AMP 1000 138% 100 0 0.01 115% 0.1 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 29 SERIES 1536 MINIATURE PROTECTION AMBIENT-TEMPERATURE COMPENSATED Three-Pole High Performance PERFORMANCE DATA Interrupting Capacity 1,000A at 205V, 400 Hz., three-phase symmetrical fault 1,000A at 120V, 400 Hz., single-phase fault Common trip mechanism trips all three phases, regardless of which phase is overloaded. Endurance At 120VAC, 400 Hz.: inductive load -- 5,000 cycles; resistive load -- 5,000 cycles; mechanical cycling, no load -- 5,000 cycles Overload Cycling 100 operations at 200% load Integral Barriers Dielectric Strength 1,500V, minimum Terminals are separated by barriers molded into the case. Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop Varies with rating (see "Ordering Information") Single-Hole Mounting Vibration Exceeds MIL-STD-202, Method 204, Condition A For quick, easy installation. Shock Exceeds 30G's, 11 Millisec (half-sine pulse) MIL-STD-202, Method 213 Test J Shock And Vibration Resistant Construction Acceleration Exceeds 10G's Weight 181 grams (.40 lbs.) Three-Phase Protection Permits use in various types of portable and mobile airborne equipment. Performance Rated Circuit Breaker The 1536-001 is a lightweight, miniature breaker that features three bimetal sensing elements having very fast electro-dynamic response under short circuit conditions, and standard trip characteristics at lower levels of overloads. Single hole mounting and small size facilitate easy installation. The breaker's one-piece, glassfilled case features integrallymolded barriers to separate the terminals. OVERLOAD CALIBRATION DATA @ 25C @ +71C @ -55C Specification Table MIN MAX MIN MAX MIN MAX Test Time Parameters Must Hold 105 -- 70 -- 130 -- % For 1 Hour Must Trip -- 138 Balanced* -- 110 -- 160 % Within 1 Hour 200% Overload 10.00 70.0 -- -- -- -- Seconds 400% Overload 2.00 10.0 -- -- -- -- Seconds 600% Overload 1.00 4.0 -- -- -- -- Seconds 1000% Overload 0.35 1.4 -- -- -- -- Seconds *Unbalanced load, individual phases: 145% Trip curve available. ORDERING INFORMATION Ampere Rating Voltage Drop Max.* Part Number 5 0.350 1536-001-5 7 1/2 0.325 1536-001-705 10 0.300 1536-001-10 15 0.250 1536-001-15 20 0.200 1536-001-20 25 0.180 1536-001-25 30 1.180 1536-001-30 35 0.175 1536-001-35 40 0.175 1536-001-40 50 0.150 1536-001-50 * At rated nominal current. For other amperage ratings and configurations, consult the Business Unit. 30 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 1536 DIMENSIONS LOCATING PIN .093 DIA. RECOMMENDED MOUNTING .125 .005 DIA. .375 .005 TO CLOF PIN 5 .484 DIA. .375 .005 1.350 1.312 O ER EPOX MAX. CO ERING CAL SCREW AMPERE RATING IN WHITE FIGURES .410 DIA. .330 DIA. MOUNTING NUT MS25082-B21 MOUNTING LOCKWASHER MS35333-126B .255 CLOSED .500 TRIPPED BLACK ACTUATOR WHITE TRIP INDICATOR 15 -32 THREAD 32 .250 2.170 MAX. 1.530 REF. .045 1.900 45 .688 .375 1.376 LINE TERMINALS .750 2.160 MAX. 6 SCREWS, #8-32 MS35206-241 & LOCKWASHERS MS35338-42 TRIP CURVE TYPICAL TRIP CURVE AT 25C Percentage Of Circuit Breaker's Rated Current 10000 1000 138% 100 0 0.01 105% 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 31 SERIES 4330 AMBIENT TEMPERATURE COMPENSATED Standard Three-Phase Protection Qualified PERFORMANCE DATA Interrupting Capacity 1,200A balanced at 205V, 400Hz, AC and 2,000A unbalanced at 120V, 400Hz, AC, at sea level and 70,000 feet Endurance 120V, 400 Hz., AC: inductive load -- 2,500 cycles; resistive load -- 5,000 cycles; mechanical cycling no load -- 5,000 cycles Overload Cycling 100 cycles at 200% Dielectric Strength At sea level, 25C 1,500V, AC. At 70,000 ft. +71C 500V, AC Insulation Resistance Not less than 100 megohms at 500V, DC Voltage Drop Varies with rating (see "Ordering Information") Vibration Meets specification MIL-STD-202, Method 204, Condition A-10G., 10-500 Hz. MS "V" type, meets Condition B, 15G, 10-2,000 Hz. and Condition C 10G, 10-2,000 Hz. Shock 50G's. MIL-STD-202, Method 213 Test G Acceleration Exceeds 10G's Weight 68 grams max. (0.15 lbs.) To MS14154 of MIL-C-5809. Lightweight Weighs 68 grams maximum (0.15 lbs). Vibration Resistance Vibration resistance and mechanical life exceed MIL Specs -- including random vibration. Miniature Size -- High Performance 19.8mm, 46.7mm, 35.0mm behind panel depth. Temperature-Compensated Ambient-temperaturecompensated from -55C to +71C. Note: higher operating ranges are available. Performance Rated Circuit Breaker This lightweight, miniature, three-phase circuit breaker, Series 4330, reflects the latest advancements in circuit breaker design, incorporating self-wiping contacts, tight tolerances in design, and stringent manufacturing standards. It is fungusproof and highly resistant to corrosion. The trip-free thermal mechanism avoids nuisance trips (even during temporary surges of starting loads) under ambient temperatures ranging from -55C to +71C. Calibration integrity is maintained through wide variations in ambient temperature and altitude, making this circuit breaker ideal for applications where temperature is not controlled. OVERLOAD CALIBRATION DATA @ 25C @ +71C @ -55C Specification Table MIN MAX MIN MAX MIN MAX Test Time Parameters Must Hold 110 -- 100 -- 110 -- % For 1 Hour Must Trip -- 145 -- 145 -- 165 % Within 1 Hour 200% Overload 4.00 20.00 3.00 20.00 6.00 40.00 Seconds 500% Overload 0.40 2.00 0.33 1.70 0.55 3.50 Seconds 1000% Overload 0.10 0.53 0.08 0.40 0.15 0.80 Seconds ORDERING INFORMATION LONG BUTTON STANDARD HIGH VIBRATION LONG BUTTON VIBRATION VOLTAGE MS APPROVAL AMPERE DROP STATUS RATING MAX. * MS P/N SAFRAN MP P/N MS P/N SAFRAN MP P/N MS P/N SAFRAN MP P/N MS P/N SAFRAN MP P/N MS Approved 1 1.10 MS14154-1 4330-001-1 MS14154-1L 4330-007-1 MS14154-1V 4330-008-1 MS14154-1VL 4330-009-1 MS Approved 2 0.75 MS14154-2 4330-001-2 MS14154-2L 4330-007-2 MS14154-2V 4330-008-2 MS14154-2VL 4330-009-2 MS Approved 2 1/2 0.70 MS14154-2 1/2 4330-001-205 MS14154-2 1/2L 4330-007-205 MS14154-2 1/2V 4330-008-205 MS14154-2 1/2VL 4330-009-205 MS Approved 3 0.55 MS14154-3 4330-001-3 MS14154-3L 4330-007-3 MS14154-3V 4330-008-3 MS14154-3VL 4330-009-3 MS Approved 4 0.45 MS14154-4 4330-001-4 MS14154-4L 4330-007-4 MS14154-4V 4330-008-4 MS14154-4VL 4330-009-4 MS Approved 5 0.35 MS14154-5 4330-001-5 MS14154-5L 4330-007-5 MS14154-5V 4330-008-5 MS14154-5VL 4330-009-5 This series is available in many optional configurations. MS Approved 7 1/2 0.30 MS14154-7 1/2 4330-001-705 MS14154-7 1/2L 4330-007-705 MS14154-7 1/2V 4330-008-705 MS14154-7 1/2VL 4330-009-705 MS Approved 10 0.28 MS14154-10 4330-001-10 MS14154-10L 4330-007-10 MS14154-10V 4330-008-10 MS14154-10VL 4330-009-10 It is presently being manufactured with 7/16, MS Approved 15 0.28 MS14154-15 4330-001-15 MS14154-15L 4330-007-15 MS14154-15V 4330-008-15 MS14154-15VL 4330-009-15 MS Approved 20 0.25 MS14154-20 4330-001-20 MS14154-20L 4330-007-20 MS14154-20V 4330-008-20 MS14154-20VL 4330-009-20 Multiple Options 15/32 and metric mounting sleeves. Many versions of different terminals, barriers, and hardware are current production items. Several different button options provide our customers * AT RATED NOMINAL CURRENT For other amperage ratings and configurations, consult the Business Unit. with additional flexibility. 32 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." SERIES 4330 DIMENSIONS MIL Spec Part No. A*Max. B*Min. MS14154 4330-001 0.750 0.470 MS14154L 4330-007 1.125 0.845 MS14154V 4330-008 0.750 0.470 MS14154VL 4330-009 1.125 0.845 RECOMMENDED MOUNTING Min. Panel Thickness .025 Max. Panel Thickness .100 .781 MAX. .453 .005 DIA. 5 .125 .005 DIA. .375 .005 .375 .010 BLACK BUTTON WHITE TRIP INDICATOR .4375-32UN- A THREAD .395 .005 DIA. .010 .045 .005 MOUNTING NUT MS25082-C18 A* B* MOUNTING LOCKWASHER MS35333-141 1.030 MAX. 1.218 1.343 MAX. LOCKWASHER MS35338-137 SCREW MS51957-41 .500 .593 Percentage Of Circuit Breaker's Rated Current TRIP CURVE 10000 TYPICAL TRIP CURVE AT 25C RANGE AT 25C UPPER LIMIT AT -55C. REFERENCE ONLY 1000 165% 145% 110% 100% 100 LOWER LIMIT AT 71C. REFERENCE ONLY 0 0.01 0.1 1.0 10 100 1000 10000 Time To Open (Trip) In Seconds "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 33 REMOTE CONTROLLED CIRCUIT BREAKER (RCCB) Three Phase * 115/200 VAC 400 Hz * Three Phase Only Single Phase * 28 VDC * 115/200 VAC 400 Hz Qualified Qualified to demanding performance parameters of MIL- PRF 83383 standard. PERFORMANCE DATA Rupture Levels 3600 A (115 VAC or 28VDC for 1Pole and 115VAC for 3 Pole) Endurance (Resistive & Inductive(Motor) 50,000 Cycles Endurance (Motor) 5-50A: 50,000 cycles; 60-100A: 25,000 cycles Endurance (Lamp) 5-25A: 50,000 cycles; 35-50A: 25,000 cycles; 60-100A: no rating Dielectric Strength 1500V, 60Hz, MIL-STD-202, method 301, 0.5 MA max Insulation Resistance 100 mega ohm min, MIL-STD-202, method 302 Thermal Temperature Range -54C to 71C (-65F to 160F). MIL-STD-202, Method 107 Vibration 10G's to 2000 Hz. Exceeds MIL-STD-202, Method 204, Condition C, 10 microseconds max. chatter Shock 25G's. MIL-STD-202, Method 213, 10 microseconds max. chatter Altitude 50,000 ft. EMI Requirements MIL-STD-461, Requirements CS114 and RE102 over the frequency range of 14 KHz to 400 MHz and RE102 limits for Aircraft and Space Systems. Weight and Cost Savings EMI/RFI Susceptibility and Generation MIL-STD-461, Class 1D In distributed-load applications, RCCBs are a more efficient power distribution solution promoting cost and weight savings through the elimination of long runs of heavy cables associated with the conventional relay flight deck circuit protector method. Control of the RCCB requires only one #22 AWG control wire from the ICU on the flight deck to the RCCB. Moisture Resistance MIL-STD-202, method 106 Salt Spray Resistance MIL-STD-202, method 101, Condition B Sand and Dust Resistance MIL-STD-202, method 110, Condition A Fungus Resistance MIL-HDBK-454, Guideline 4 Explosion Proof MIL-STD-202, method 109 Weight (Standard) 5-25A: 318 grams (0.703 lbs.); 35-50A: 325 grams (0.719 lbs.); 60-100A: 332 grams (0.734 lbs.) Use as a Relay, Circuit Breaker, Or Both RCCBs combine the best attributes of a circuit breaker and a relay. Automatically protects the wires and the load device during circuit/load breakdown, but allows the flight deck control of the load during normal operation. Cockpit Space Savings An RCCB system removes the presence of large circuit breakers from the cockpit while permitting remote On/Off operation from the flight deck. Combine Safran Electrical & Power RCCB with Indicator Control Unit (ICU) model #1500-053-05. Weight (w/ Auxiliary Contacts) 5-25A: 332 grams (0.734 lbs.); 35-50A: 339 grams (0.750 lbs.); 60-100A: 346 grams (0.766 lbs.) OVERLOAD CALIBRATION DATA Specification Table Must Hold @ 25C MIN MAX 115% @ +71C MIN MAX 115% Must Trip 138% @ -54C MIN % for 1 Hour 115% 138% ORDERING INFORMATION Standard SAFRAN ELECTRICAL & POWER % Within 1 Hour 150% Single Pole Single Throw (Double Break Contacts) 34 Test Time Parameters MAX Three Pole Single Throw (Double Break Contacts) w/ Auxiliary Contacts w/ Auxiliary Contacts AMPERE RATING 5 7.5 MS P/N M83383/01-01 SAFRAN P/N SM600BA5N1 ** MS P/N M83383/02-01 SAFRAN P/N SM600BA5A1 ** MS P/N SAFRAN P/N ** ** 10 M83383/01-03 SM600BA10N1 M83383/02-03 SM600BA10A1 M83383/04-03 SM601BA10A1 15 M83383/01-04 SM600BA15N1 M83383/02-04 SM600BA15A1 20 M83383/01-05 SM600BA20N1 M83383/02-05 SM600BA20A1 25 M83383/01-06 SM600BA25N1 M83383/02-06 SM600BA25A1 35 M83383/01-07 SM600BA35N1 M83383/02-07 SM600BA35A1 M83383/04-07 SM601BA35A1 40 50 60 75 80 100 M83383/01-08 M83383/01-09 M83383/01-10 M83383/01-11 SM600BA40N1 SM600BA50N1 SM600BA60N1 SM600BA75N1 ** SM600BA100N1 M83383/02-08 M83383/02-09 M83383/02-10 M83383/02-11 SM600BA40A1 SM600BA50A1 SM600BA60A1 SM600BA75A1 ** SM600BA100A1 M83383/04-08 SM601BA40A1 SM601BA50A1 SM601BA60A1 M83383/04-10 * * * * M83383/01-13 M83383/02-13 SM601BA15A1 M83383/04-05 SM601BA20A1 SM601BA25A1 M83383/04-10 M83383/04-10 All Ampere Ratings equal to Rated Contact Loads (Resistive, Inductive, Motor, and Lamp) except as noted. * No Lamp Load Rating ** Contact Business Unit TF300-1E Note: Contact Business unit on Alternate Amperages, Trip Times, Control Configurations, Grounding, Auxiliary Switches, Mounting Systems, etc. "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." REMOTE CONTROLLED CIRCUIT BREAKER (RCCB) OVERLOAD CALIBRATION DATA - SINGLE POLE AMPERE RATING 200% Trip Times -54C to +71C MIN MAX 400% Trip Times -54C to +71C MIN MAX OVERLOAD CALIBRATION DATA - THREE POLE 1000% Trip Times -54C to +71C MIN MAX MIN MAX 15 13 80 1.7 10 0.35 1.2 20 14 80 2.9 9.6 0.4 1.15 1.2 25 15 80 2.6 10 0.4 1.3 16 80 2.8 11 0.35 1.3 1.2 6.4 0.3 40 2.4 6.8 0.33 10 12 42 2.8 8.5 0.42 0.35 MAX 1.05 40 11 8.3 MIN 1.1 7 7.5 1.7 MAX 1000% Trip Times -54C to +71C 1.2 5 45 MIN 400% Trip Times -54C to +71C SECONDS SECONDS SECONDS SECONDS 2.8 11 0.42 1.3 SECONDS SECONDS SECONDS SECONDS 13 200% Trip Times -54C to +71C AMPERES SECONDS SECONDS 10 12 80 AMPERES SECONDS SECONDS 15 AMPERE RATING 20 14 46 2.9 7.6 0.4 1.15 35 25 15 50 2.6 8.7 0.4 1.3 40 16 80 2.6 10 0.36 1.3 35 16 55 2.8 8.3 0.35 1.3 50 13 80 2.9 10 0.4 1.25 60 13 80 2.4 16 0.26 1.8 40 16 55 2.9 9.2 0.36 1.3 50 13 55 2.9 10 0.4 1.25 60 13 60 2.6 13 0.26 1.8 75 13 60 2.5 13 0.26 1.8 80 14 60 2.7 12.5 0.3 2 100 17 63 3.5 13 0.38 1.9 TRIP CURVE Contact business unit for trip curve. "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 35 REMOTE CONTROLLED CIRCUIT BREAKER (RCCB) 1 POLE AND 3 POLE Engineering Data Application Note Distributed Load Concept With RCCB Without RCCB 1/2 AMP C8 SWITCH SWITCH 1/2 AMP 100 AMPS B U S S C8 100 AMPS 100 AMPS C8 RCCB L O A D RELAY B U S S MS22073-1/2 OR MS26574-1/2 L O A D FLIGHT DECK FLIGHT DECK Typical Wiring Diagram Integrated Wire Termination Module (MIL-STD-1549) LOAD 3 LINE A1 A2 4 5A 5B 6 LOAD LINE LOAD LINE S3 S1 S2 LOAD Auxiliary Contacts When Applicable To Indicator/ Control Unit Circuit Breaker Internal Connection Type MS220731/2 OR MS26574Backup Control Power (when used) 1/2 115 V 400 HZ or 28 Vdc (Must be same AC Phase as the "Line" Power) Contacts and Coil Circuits Only 3 4 5A 5B S3 S1 S2 To Indicator/ Control Unit Circuit Breaker Type MS220731/2 OR MS265741/2 Wiring for Multiple Line Protection 3 4 5A 5B 6 3 4 5A 5B 6 3 4 5A 5B 6 Auxiliary Contacts Internal Connection Auxiliary Contacts S2 S3 A2 A1 Internal Coil Current Cut-Off Single Pole S2 S3 A2 B2 S2 C2 S2 S2 Intermittent Duty Coils Current CutOff Controlled Electronically NOTE: Units with date codes beginning with third quarter 1993 use electronically controlled coil cut-off without internal coil current cut-off. NOTE: Terminals 5A and 5B internally grounded to the mounting leg (s). Integrated wire termination (IWT) module accepts pin contacts P/N M39029/1-100 or -101. Use with insertion/extraction tool M81969/14-02. 36 Backup Control Power (when used) 28 Vdc Contacts and Coil Circuits Only S2 S1 LINE Three Pole SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." REMOTE CONTROLLED CIRCUIT BREAKER (RCCB) 1 POLE AND 3 POLE Engineering Data Approximate Dimensions - 1 Pole LOAD A2 .688/ 17.48 .172/4.37 DIA. 2 MTG. HOLES LINE A1 Typical Placement of Rating on Top Plane R. 20 5.08 50 2.940 74.68 3.250 82.55 2.250 57.15 1.530 38.86 Mtg. Flanges Main Contact Mate As Shown Position Indicator Red: Closed; Green: Open 1.200 30.48 .350 8.89 .42 10.67 .07 1.778 .056 1.42 .500 - .610 12.70 - 15.24 .180 4.57 Name Plate Options * Special application auxil iary switches * Unique grounding * Power sources * Other current ratings * Control via systems other than I/CU * Low level auxiliary con- tacts available * Data Bus/Interface capabil- ity available * Electronically held coil 4.26 108.20 3.42 86.87 .084 2.13 3Pole LINE A1 3.69 93.73 1.50 38.86 2.940 74.68 .07 1.78 .350 8.89 LINE B1 3.29 83.57 2.03 51.56 .77 19.56 2.526 64.16 .05 1.27 .130 3.30 50 LOAD C2 2.526 64.16 2.28 57.91 LINE C1 LOAD B2 LOAD A2 Main Contact Position Indicator Red: Closed; Green: Open 4.26 108.20 Location of NamePlate 3.43 87.12 3.250 82.55 Coil Operate Current/Set And Trip Time RCCB Circuits 1 Pole 3 Pole Nominal System Voltage 28 Vdc (18 Volts MIN.) 115 Vac 400 Hz (104 V. MIN.) 28 Vdc (18 Volts MIN.) 115 Vac 400 Hz (104 V. MIN.) I/CU Set Current @ Nom Voltage (Mulliamp) Set Coil Current @ Nom Voltage Pulse 2 MAX. Set Time *I/CU. Trip Current Nominal Nominal Voltage & Room Temp. Most Adverse Condition - MIN. Voltage 71C. Ambient 71C & Nominal Voltage -54C & Nominal Voltage Room Temp. Nominal Voltage 3.0 AMP MAX 20 Millisec 35 Millisec 1.4 AMP 1.9 AMP 2 10 AMP MAX 15 Millisec 30 Millisec 6.8 AMP ** 6.3 AMP ** 2 7.0 AMP MAX 20 Millisec 35 Millisec 1.5 AMP 2.0 AMP 2 13.0 AMP MAX 15 Millisec 30 Millisec 4.3 AMP ** 3.3 AMP ** * MAX. I/CU. Line Impedance 7.5 ** Average Half-Wave Rectified DC Current 71C & Nominal Voltage -54C & Nominal Voltage MAX. Standby Current Milliamp 1.6 AMP 0.9 AMP *** 2.1 AMP 10 8.6 AMP ** 6.1 AMP ** 7.0 AMP ** 10 1.7 AMP 0.9 AMP *** 2.2 AMP 10 4.5 AMP ** 4.0 AMP ** 3.1 AMP ** 10 Current Decreases w/Time so that I2t ***Absolute Min. Value from -54 to +71C "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 37 REMOTE POWER CONTROLLER (RPC) Single Pole * 28 VDC Electronic Current Sensing The electronic over current sensing of these devices offer several advantages over the bimetal sensing RCCB. Trip current levels can be closely controlled, for better protection of sensitive loads, trip times are faster, and both can be customized for specific applications. Other advantages included less heat buildup, and higher current capabilities in the same small package. Use as a Relay, Circuit Breaker, Or Both RPCs, like RCCBs, combine the best attributes of a circuit breaker and a relay. Automatically protects the wires and the load device during circuit/load breakdown, but allows the flight deck control of the load during normal operation. Weight and Cost Savings In distributed-load applications, RPCs are a more efficient power distribution solution promoting cost and weight savings through the elimination of long runs of heavy cables associated with the conventional relay - flight deck circuit protector method. Control of the RPC requires only one #22 AWG control wire from the ICU (model #1500-053-05) on the flight deck to the RPC. PERFORMANCE DATA Rupture Levels 2500 A (28VDC) Endurance (Resistive) 50,000 Cycles Endurance (Inductive and Motor) 25,000 cycles Endurance (Lamp) No Rating Mechanical Life 100,000 cycles Dielectric Strength Sea Level - VRMS .2-3 seconds: Coil to Case - 1250 initial. 1,000 After Life, All other Points 1,800 Initial, 1350 After Life 50,000 Ft. - VRMS 1 Minute: Coil to Case 500 Initial & After Life. All other Points 700 Initial & After Life 1100 Megaohms initial, 50 Megohms after Life, MIL-STD-202, Insulation Resistance method 302, test condition B Thermal Temperature Range -55C to 85C (-67F to 185F). Vibration Sinusoidal 5 to 10 Hz: 0.08 DA; 10 TO 55 Hz: 0.06 DA; 55 to 2000 Hz: 10G's Shock 50G's. (1/2 sine, 10-12 ms) Altitude 50,000 Ft. Maximum EMI Requirements MIL-STD-461, Requirements CS114 and RE102 over the frequency range of 14 KHz to 400 MHz and RE102 limits for Aircraft and Space Systems Moisture Resistance MIL-STD-202, method 106 Salt Spray Resistance MIL-STD-202, method 101, Condition B Sand and Dust Resistance MIL-STD-202, method 110, Condition A Fungus Resistance MIL-HDBK-454, Guideline 4 Explosion Proof MIL-STD-202, method 109 Weight (Standard) 425.017 grams (0.937 lbs.) OVERLOAD DATA % Rated Current Trip in Seconds -55C to +85C 100% No Trip 125% 45 Sec. Trip 200% 0.22 Sec. Trip 400% 0.095 Sec. Trip ORDERING INFORMATION Single Pole Single Throw (Double Break Contacts) Rated Contact Load (Amperes) AMPERE 28 VDC RATING SAFRAN P/N 125 SM600BA125A1 125 125 125 5 150 SM600BA150A1 150 150 150 5 175 SM600BA175A1 175 150 175 5 200 SM600BA200A1 200 150 175 5 Notes: * One auxiliary contact included on each unit * Contact Business Unit on Alternate Amperages, Trip Times, Control Configurations, Grounding, Auxiliary Switches, Mounting Systems, etc. 38 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." REMOTE POWER CONTROLLER (RPC) Integrated Wire Module Typical Placement of Rating on Top Plane .172/4.37 DIA. 2 MTG. HOLES LOAD A2 Approximate Dimensions - 1 Pole .688/ 17.48 LINE A1 Engineering Data 125 .256/6.50 2.940 74.68 3.250 82.55 .150 3.81 2.250 57.15 Barrier Black Nylon Per MIL-M20693A Type I. General Purpose 1.530 38.86 Position Indicator Red: Closed; Green: Open .350 8.89 1.200 30.48 .42 10.67 .07 1.778 .056 1.42 .05/1.27 Terminal Pad .6 DIA. .180 4.57 Name Plate 4.26 108.20 3.42 86.87 R.06 1.52 Typical Wiring Diagram Approximate Dimensions Auxiliary Contacts S2 S1 S3 A2 A1 LOAD A2 3 To Indicator / Control Unit Circuit Breaker Type MS22073 - 1/2 Or MS26574 - 1/2 LINE A1 A2 A2 Over Current Detector 5A 5B A2 3 28 VDC Back Up Power 4 Module: Integrated wire termination. Terminals will accept PIN contact per M39029/1 - 101. Use insertion/extraction tool M81969/14 - 02. 5A 3 4 5B S3 S2 S1 COIL OPERATE CURRENT/SET AND TRIP TIME MAX. Set Time *I/CU. Trip Current Nominal Nominal System Voltage I/C Set Current @ Nom. Voltage (milliamp) Set Coil Current @Nom Voltage Pulse Nominal Voltage @ Room Temp Most Adverse Condition-Min. Voltage 71C Ambient 71C and Nominal Voltage -54C and Nominal Voltage Room Temp and Nominal Voltage Max. Standby Current (milliamp) 28 VDC (18 Volts Min) 2 3.7 Amp 20 Millisec 35 Millisec 1.76 Amp 1.25 Amp 1.89 Amp 30 * MAX I/CU. LINE IMPEDANCE 7.5 Ohms CURRENT DECREASES W/TIME SO THAT I2t >= 2 "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 39 ADDITIONAL PRODUCTS Additional Series In addition to the circuit breaker products described in this catalog, Safran Electrical & Power has the capability to manufacture over twenty additional series of circuit breakers. Please contact the Business Unit at 1-800-955-7354 for details or ordering information on these unique devices. 40 Series60 Series100 Series130 Series140 Series180 Series260 Series270 Series780 Series920 Series930 Series960 Series970 Series1200 Series1538 Series1540 Series1585 Series2100 Series4380 Series8500 Series9500 Additional Product Design Options If your application calls for an amperage, feature, or option we do not currently list in our catalog, please contact the Business Unit at 1-800-955-7354. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." REFERENCE DOCUMENTS Glossary of Terms Glossary of Terms ACTUAToR - Mechanism of the switch that when operated transfers the internal contacts. CYCLE - An interval of time during which a sequence of a recurring succession of events or phenomena is completed. ALLoy - A metal composed of two or more different metals to obtain a desired physical property. DETENT - A mechanical positioning device designed to stop the actuator travel at each successive electrical circuit. ALTERNATE ACTIoN - Typically associated with pushbutton switches; switch contacts remain in a given circuit condition after removal of actuating force; when actuating force is applied a second time, the opposite circuit is engaged. DIELECTRIC STRENGTH - The ability of an insulating mate-rial to withstand an over voltage without exceeding minimal leak-age current levels or material breakdown. Specified in voltage (VAC), usually between a live metal part and ground or between open contacts of a device. ALTERNATING CURRENT (AC) - An electric current that reverses direction at regularly recurring intervals of time. AMBIENT TEMPERATURE - Refers to the temperature of the air immediately surrounding the device. DIFFERENTIAL TRAvEL (D.T.) - The amount of actuator or plunger travel measured from the point where contacts "snap over" to the point where they "snap back." AMBIENT TEMPERATURE RANGE - Operating temperature range. DIRECT CURRENT (DC) - A unidirectional current in which changes in value are either zero or so small that they may be neglected. As originally used, the term designates a practically non-pulsating current. ANGLE oF THRoW - Associated with rocker and toggle switches to indicate the total travel arc of the actuator, measured in degrees. DoUBLE BREAK CoNTACTS - (Twin break.) Switch circuit breaks in two places. Also referred to as form Z circuitry. ANNEALED - To heat and then cool (as steel or glass) for softening and making the material less brittle; for example, annealed copper is less brittle. ARCING - The flow or movement of electric current between opening or closing switch contacts. BASIC SWITCH - Classified as a self-contained switching unit. May be used independently or with a gang-mounted assembly. Usually mechanically actuated. BREAK - To open an electrical set of closed contacts. BREAK BEFoRE MAKE - To interrupt one circuit of a pole before completing a second circuit of the same pole. CAPACITIvE LoAD - A lumped capacitance that is switched as a unit. CoNTACT BoUNCE - The repeated rebounding of the movable contact during the transfer from one throw to the next; typically measured in micro or milliseconds. CoNTACT RESISTANCE - The resistance measured across a pair of closed contacts, which is in series with the load. Resistance levels will increase over time based on usage load conditions and environment. Measured in milliohms. CREEPAGE - The unwanted flow of electrical current from one conductive part to another. CURRENT - The flow of electrons within a wire or a circuit; measured in amperes. 1 DoUBLE PoLE (DP) - see Pole. DoUBLE-PoLE DoUBLE-THRoW (DPDT) - Switches which make and break two separate circuits. Both normally open and normally closed set of contacts offered with each pole. DoUBLE THRoW (DT) - see Throw. DRy CIRCUIT - A low energy circuit condition where no arcing occurs during contact switching; typically in millivolt and milliamp ranges of current and voltage. FLASH PLATING - A very thin or "instant plating" process usually measuring less than 10 micro-inches thick. FLUx - A substance (such as rosin) applied to surfaces to be joined by soldering, brazing or welding to clean and free them from oxide and promoting their union. FREE PoSITIoN (F.P.) - Switch plunger or actuator position when no outside force is applied, other than gravity. FULL ovERTRAvEL FoRCE - The amount of force required to achieve full overtravel of the switch actuator. GRoUND - A conducting path between an electric circuit or equipment and the earth, or some large conducting body serv-ing in place of the earth whether the connection is intentional or accidental. HERMETICALLy SEALED SWITCH - A switch in a gas tight enclosure that has been completely sealed by fusion or comparable means to insure a low rate of gas leakage over a long period of time. All junctures made with glass-to-metal or metal-tometal. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." Glossary of Terms INDUCTIvE LoAD - A load in which the initial current on make (contact closing) is lower than steady state and the voltage is greater than steady state upon break (contact opening). When contacts are opened (break), the stored energy of the inductor combined with the long arcing time is severe on the switch contacts. INRUSH - The amount of current that a load draws when initially closing the switch contacts. May cause severe degradation of contacts. INSULATIoN RESISTANCE - The electrical resistance between two normally insulated parts. No - Normally Open contacts; circuit is open when actuator is in its normal or at-rest position. NoISE, ELECTRICAL - Unwanted electrical signals that produce undesirable effects in the circuits of the control systems in which they occur. NoMINAL - The result of the calculated actual value range. NoNSHoRTING CoNTACTS - Contacts which break before make. oPAQUE - A condition that is not pervious to radiant energy and especially light. IP - Part of the IEC529 standard recommending the degree of protection of enclosures for low-voltage switch gear. Deals with the prevention of ingress of liquids and solid foreign matter in enclosures. oPERATING FoRCE (o.F.) - A measured amount of force applied to switch plunger or actuator to cause contact "snap-over" to occur. ISoLATED LAMP CIRCUIT - Independent of switching circuit; lamp is operated on a completely separate circuit from the switch circuit. oPERATING PoSITIoN (o.P.) - Position of switch plunger or actuator at which point the internal switch contacts snap from normal to operated position. LAMP LoAD - Upon initial contact closure (make), high inrush current occurs (approximately 10 times greater than the steady state). ovERTRAvEL (o.T.) - Switch plunger or actuator travel designed to go safely beyond the operating position. LATCHDoWN - One type of alternate action in which the pushbutton is mechanically secured in the down position; the pushbut-ton is at "normal" position for one circuit and latched down posi-tion for the other circuit condition. LED (LIGHT EMITTING DIoDE) - A solid state diode that provides variable light. PANEL SEAL - Prevents liquids and solid particles from reach-ing the switch contacts from the front of the panel if the panel is subjected to foreign contamination usually caused by spills or splashing. PARALLEL CIRCUIT - Electrical circuit having two or more inductors or paths for the current to flow. LoGIC LEvEL - An application in which power levels do not cause arcing, melting, or softening of contacts; also referred to as dry circuit or low energy; typically requiring gold contacts for reliability. PF - Power Factor; a means of determining contact capability when used with inductive loads relative to the standard resistive load rating; for example, if PF = 1.0, the inductive load is 100% of the resistive load, or if PF = 0.6, the inductive load is 60% of the resistive load. MAINTAINED ACTIoN - To remain in a given circuit condition until actuated into the next circuit condition. PoLE - A single common electrical input having one or more outputs. MAKE BEFoRE BREAK - Completing one circuit of a pole before interrupting another of the same pole. PoSITIoN - The mechanical stops or detents associated with the switch actuator. MoMENTARy ACTIoN - Mechanically returning from a temporary circuit condition to the maintained circuit condition as soon as the actuating force is removed. PRECISIoN SNAP-ACTING SWITCH - An electromechanical switch having predetermined and accurately controlled characteristics and having a spring-loaded quick make and break contact action. NC - Normally Closed contacts; circuit is closed when actuator is in its normal at-rest position. NEMA - National Electrical Manufacturers Association, an agency of the United States, setting standards for products distributed worldwide; applied to switches in their degrees of protection against the intrusion of liquids, dust, and other contaminants. PRETRAvEL (P.T.) - Measured travel associated with the moving of the plunger or actuator from free position to operating position. PUSH-PUSH - Considered a form of alternate action, but is not latchdown. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 2 REFERENCE DOCUMENTS Glossary of Terms Glossary of Terms RELEASE FoRCE (R.F.) - Amount of force still applied to switch plunger or actuator at moment contacts snap from operated position to unoperated position. ToTAL TRAvEL - Combined distance of actuator pretravel and overtravel; total distance actuator moves from relaxed position past the point of electrical contact and to the end of travel. RMS - Root Mean Square. TRANSLUCENT - Transmitting and diffusing light so that objects beyond cannot be seen clearly. SHoRTING CoNTACTS - Electrical switch contacts that are designed to make before break. SILICoNE RUBBER - Rubber produced from silicone elastomers with a high amount of flexibility, resilience, and tensile strength over a wide temperature range. TRANSPARENT - Having the property of transmitting light without appreciably scattering so that objects lying beyond are entirely visible. TRAvEL - The distance the switch actuator moves which causes a change of electrical circuits. SNAP ACTIoN - Very fast mechanical transfer of contacts from one position to another. Contact transfer action is independent of speed of actuator travel. TWo CIRCUIT - Circuit in which one circuit is made in one position and a separate circuit is made in the other position. SPST - Single Pole Single Throw - see Pole; also Throw. voLTAGE DRoP - The voltage decreases across the terminals due to the internal resistance of the device. TACTILE FEEDBACK - The switching action felt by an operator as he operates the switch from position to position. THRoW - The number of electrical circuits within a switch pole. 3 WIPING ACTIoN - The action caused by the movable switch contact sliding across the stationary contact, resulting in the cleaning of the contact surfaces. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." Glossary of Terms - Circuit Breaker Specific REFERENCE DOCUMENTS Glossary of Terms - Circuit Breakers AMBIENT COMPENSATION - Limits or eliminates thermal derating (lowering of capabili-ties) caused by extreme ambi-ent temperatures. MAXIMUM ULTIMATE TRIP (MUST TRIP) - Current rating at which a circuit protection device will trip within a certain period of time at a specified temperature. AUTOMATIC RESET - Device that will automatically open an overload circuit. It will also automatically close or com-plete the circuit after a period of time. If the overload is still pres-ent, the device will continue to cycle until either the power or the overload is removed. MINIMUM ULTIMATE TRIP (MUST HOLD) - Current rating for which a circuit protection device will not trip for an extended period of time at a specified temperature. CIRCUIT BREAKER - Device designed to open and close a circuit manually and to open the circuit automatically on a predetermined overload of cur-rent. CURRENT RATING - Designation of rating given in amperes at which the device will not trip. A specific tempera-ture is usually assigned. FUSE - A protective device using a spe-cial metal-alloyed conductor that is often notched or otherwise engineered to control the cross sectional area. A fault current will melt the narrow cross sec-tion, interrupting the flow of cur-rent. FUSIBLE LINK/FAIL SAFE - A metallic sacrificial element within the RCCB or circuit breaker that melts and then arcs due to the joule heating of an over current. This feature ensures that a fault cannot cause the RCCB or circuit break-er to fail in the closed position. INTERRUPT CAPACITY - The highest level of fault current that a circuit protective system is intended to interrupt. Depending on qualification requirements, some devices must clear the fault, be operable afterwards, and still be capable of tripping on 200 percent over-loads. While other qualified devices may have a backup device wherein the combination must successfully clear the fault while leaving the protector in a fail-safe condition (no loss of case integrity, external materials remaining unignited by gaseous emissions, and no dielectric path to grounded parts). MANUAL RESET - Refers to breakers in which the electrical contacts remain open after a trip until someone physi-cally closes or completes the circuit by either pushing a reset button or throwing a switch. 4 NUISANCE TRIPS - Those trips caused by a response to nondamaging inrush or start-up current surg-es, as opposed to an actual overcurrent trip. OVERCURRENT - That current which may cause dangerous overheating. OVERCURRENT PROTECTION - Protection achieved by limiting the duration and magnitude of exposure to an overcurrent. OVERLOAD - An electrical load or current flow greater than that which a circuit is designed to handle. OVERLOAD CAPACITY - The highest level of overload current that devices will inter-rupt and remain in operable con-dition, capable of clearing addi-tional overloads. SAFETY FACTOR - The allowance added to the steady-state application current to ensure that the protective device selected will be more than sufficient to handle the application without nuisance trips. Safran Electrical & Power recommends a minimum safety factor of 15 percent. SLOW-BLOW FUSE - A dual element fuse that allows for slow response to overloads (less than 10x rating) and fast response to fault currents. TRIP-FREE - A characteristic of certain break-ers that provides independence between the protection mecha-nism and the operating button or handle, such that a fault can-not be maintained manually (or held closed) against an overload. TRIP INDICATION - Visual sign the breaker has opened. TRIP CURVE - Graphic displaying minimum and maximum time a breaker takes to trip for given levels of over-load. SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." QUALIFIED PRODUCTS UNDER MILITARY SPECIFICATION FOR MIL-C-8509 AND MIL-C-83383 MS P/N SAFRAN P/N Page MS P/N LSAFRAN P/N MS P/N SAFRAN P/N Page MS14154-4VL 4300-009-4 32 MS25244-30 700-001-30 16 MS26574-10A 4200-004-10 22 SAFRAN P/N Page MS P/N MIL-C-8509 Page MS3320-1 4310-001-1 24 MS14154-5 4330-001-5 32 MS25244-35 700-001-35 16 MS26574-10L 4200-003-10 22 MS3320-1L 4310-005-1 24 MS14154-5L 4330-007-5 32 MS25244-P5 700-089-5 16 MS26574-15 4200-001-15 22 MS3320-1V 4310-019-1 24 MS14154-5V 4330-008-5 32 MS25244-P7 1/2 700-089-705 16 MS26574-15A 4200-004-15 22 MS3320-1VL 4310-024-1 24 MS14154-5VL 4330-009-5 32 MS25244-P10 700-089-10 16 MS26574-15L 4200-003-15 22 MS3320-2 4310-001-2 24 MS14154-7 1/2 4330-001-705 32 MS25244-P15 700-089-15 16 MS26574-20 4200-001-20 22 MS3320-2L 4310-005-2 24 MS14154-7 1/2L 4330-007-705 32 MS25244-P20 700-089-20 16 MS26574-20A 4200-004-20 22 MS3320-2V 4310-019-2 24 MS14154-7 1/2V 4330-008-705 32 MS25244-P25 700-089-25 16 MS26574-20L 4200-003-20 22 MS3320-2VL 4310-024-2 24 MS14154-7 1/2VL 4330-009-705 32 MS25244-P30 700-089-30 16 MS26574-D3/4 4200-006-075 22 MS3320-2 1/2 4310-001-205 24 MS14154-10 4330-001-10 32 MS25244-P35 700-089-35 16 MS26574-D3/4L 4200-007-075 22 MS3320-2 1/2L 4310--005-205 24 MS14154-10L 4330-007-10 32 MS25244-PT5 700-092-5 16 MS26574-D1 4200-006-1 22 MS3320-2 1/2V 4310-019-205 24 MS14154-10V 4330-008-10 32 MS25244-PT7 1/2 700-092-705 16 MS26574-D1L 4200-007-1 22 MS3320-2 1/2VL 4310-024-205 24 MS14154-10VL 4330-009-10 32 MS25244-PT10 700--092-10 16 MS26574-D1 I/2 4200-006-105 22 MS3320-3 4310-001-3 24 MS14154-15 4330-001-15 32 MS25244-PT15 700-092-15 16 MS26574-D1 1/2L 4200-007-105 22 MS3320-3L 4310-005-3 24 MS14154-15L 4330-007-15 32 MS25244-PT20 700-092-20 16 MS26574-D2 4200-006-2 22 MS3320-3V 4310-019-3 24 MS14154-15V 4330-008-15 32 MS25244-PT25 700-092-25 16 MS26574-D2L 4200-007-2 22 MS3320-3VL 4310-024-3 24 MS14154-15VL 4330-009-15 32 MS25244-PT30 700-092-30 16 MS26574-D2 1/2 4200-006-205 22 MS3320-4 4310-001-4 24 MS14154-20 4330-001-20 32 MS25244-PT35 700-092-35 16 MS26574-D2 1/2L 4200-007-205 22 MS3320-4L 4310-005-4 24 MS14154-20L 4330-007-20 32 MS25361-50 160-012-50 12 MS26574-D3 4200-006-3 22 MS3320-4V 4310-019-4 24 MS14154-20V 4330-008-20 32 MS25361-50V 160-086-50 12 MS26574-D3L 4200-007-3 22 MS3320-4VL 4310-024-4 24 MS14154-20VL 4330-009-20 32 MS25361-60 160-012-60 12 MS26574-D4 4200-006-4 22 MS3320-5 4310-001-5 24 MS22073-1 4001-001-1 32 MS25361-60V 160-086-60 12 MS26574-D4L 4200-007-4 22 MS3320-5L 4310-005-5 24 MS22073-1V 4001-008-1 32 MS25361-70 160-012-70 12 MS26574-D5 4200-006-5 22 MS3320-5V 4310-019-5 24 MS22073-1 1/2 4001-001-105 20 MS25361-70V 160-086-70 12 MS26574-D5L 4200-007-5 22 MS3320-5VL 4310-024-5 24 MS22073-1 1/2V 4001-008-105 20 MS25361-75 160-012-75 12 MS26574-D7 1/2 4200-006-705 22 MS3320-7 1/2 4310-001-705 24 MS22073-2 4001-001-2 20 MS25361-75V 160-086-75 12 MS26574-D7 1/2L 4200-007-705 22 MS3320-7 1/2L 4310-005-705 24 MS22073-2V 4001-008-2 20 MS25361-80 160-012-80 12 MS26574-D10 4200-006-10 22 MS3320-7 1/2V 4310-019-705 24 MS22073-2 1/2 4001-001-205 20 MS25361-80V 160-086-80 12 MS26574-D10L 4200-007-10 22 MS3320-7 1/2VL 4310-024-705 24 MS22073-2 1/2V 4001-008-205 20 MS25361-90 160-012-90 12 MS26574-D15 4200-006-15 22 MS3320-10 4310-001-10 24 MS22073-3 4001-001-3 20 MS25361-90V 160-086-90 12 MS26574-D15L 4200-007-15 22 MS3320-10L 4310-005-10 24 MS22073-3V 4001-008-3 20 MS25361-100 160-012-100 12 MS26574-D20 4200-006-20 22 MS3320-10V 4310-019-10 24 MS22073-4 4001-001-4 20 MS25361-100V 160-086-100 12 MS26574-D20L 4200-007-20 22 MS3320-10VL 4310-024-10 24 MS22073-4V 4001-008-4 20 MS26574-3/4 4200-001-075 12 MS3320-15 4310-001-15 24 MS22073-5 4001-001-5 20 MS26574-3/4A 4200-004-075 12 MIL-C-83383 MS3320-15L 4310-005-15 24 MS22073-5V 4001-008-5 20 MS26574-3/4L 4200-003-075 22 M83383/01-01 SM600BA5N1 34 MS3320-15V 4310-019-15 24 MS22073-7 1/2 4001-001-705 20 MS26574-1 4200-001-1 22 M83383/01-03 SM600BA10N1 34 MS3320-15VL 4310-024-15 24 MS22073-7 1/2V 4001-008-705 20 MS26574-1A 4200-004-1 22 M83383/01-04 SM600BA15N1 34 MS3320-20 4310-001-20 24 MS22073-10 4001-001-10 20 MS26574-1L 4200-003-1 22 M83383/01-05 SM600BA20N1 34 MS3320-20L 4310-005-20 24 MS22073-10V 4001-008-10 20 MS26574-1 1/2 4200-001-105 22 M83383/01-06 SM600BA25N1 34 MS3320-20V 4310-019-20 24 MS22073-15 4001-001-15 20 MS26574-1 1/2A 4200-004-105 22 M83383/01-07 SM600BA35N1 34 MS3320-20VL 4310-024-20 24 MS22073-15V 4001-008-15 20 MS26574-1 1/2L 4200-003-105 22 M83383/01-08 SM600BA40N1 34 MS14154-1 4330-001-1 32 MS22073-20 4001-001-20 20 MS26574-2 4200-001-2 22 M83383/01-09 SM600BA50N1 34 MS14154-1L 4330-007-1 32 MS22073-20V 4001-008-20 20 MS26574-2A 4200-004-2 22 M83383/01-10 SM600BA60N1 34 MS14154-1V 4330-008-1 32 MS22073-D1 4001-011-1 20 MS26574-2L 4200-003-2 22 M83383/01-11 SM600BA75N1 34 MS14154-1VL 4330-009-1 32 MS22073-D1 1/2 4001-011-105 20 MS26574-2 1/2 4200-001-205 22 M83383/01-13 SM600BA100N1 34 MS14154-2 4330-001-2 32 MS22073-D2 20 MS26574-2 1/2A 4200-004-205 22 M83383/02-01 SM600BA5A1 34 MS14154-2L 4330-007-2 32 MS22073-D2 1/2 4001-011-205 20 MS26574-2 1/2L 4200-003-205 22 M83383/02-03 SM600BA10A1 34 MS14154-2V 4330-008-2 32 MS22073-D3 4001-011-3 20 MS26574-3 4200-001-3 22 M83383/02-04 SM600BA15A1 34 MS14154-2VL 4330-009-2 32 MS22073-D4 4001-011-4 20 MS26574-3A 4200-004-3 22 M83383/02-05 SM600BA20A1 34 MS14154-2 1/2 4300-001-205 32 MS22073-D5 4001-011-5 20 MS26574-3L 4200-003-3 22 M83383/02-06 SM600BA25A1 34 MS14154-2 1/2L 4330-007-205 32 MS22073-D7 1/2 4001-011-705 20 MS26574-4 4200-001-4 22 M83383/02-07 SM600BA35A1 34 MS14154-2 1/2V 4330-008-205 32 MS22073-D10 4001-011-10 20 MS26574-4A 4200-004-4 22 M83383/02-08 SM600BA40A1 34 MS14154-2 1/2VL 4330-009-205 32 MS22073-D15 4001-011-15 20 MS26574-4L 4200-003-4 22 M83383/02-09 SM600BA50A1 34 MS14154--3 4330-001-3 32 MS22073-D20 4001-011-20 20 MS26574-5 4200-001-5 22 M83383/02-11 SM600BA60A1 34 MS14154-3L 4330-007-3 32 MS25244-5 700-001-5 16 MS26574-5A 4200-004-5 22 M83383/02-13 SM600BA75A1 34 MS14154-3V 4330-008-3 32 MS25244-7 1/2 700-001-705 16 MS26574-5L 4200-003-5 22 M83383/04-03 SM600BA100A1 34 MS14154-3VL 4300-009-3 32 MS25244-10 700-001-10 16 MS26574-7 1/2 4200-001-705 22 M83383/04-05 SM601BA10A1 34 MS14154-4 4330-001-4 32 MS25244-15 700-001-15 16 MS26574-7 1/2A 4200-004-705 22 M83383/04-07 SM601BA35A1 34 MS14154-4L 4330-007-4 32 MS25244-20 700-001-20 16 MS26574-7 1/2L 4200-003-705 22 M83383/04-08 SM601BA40A1 34 MS14154-4V 4330-008-4 32 MS25244-25 700-001-25 16 MS26574-10 4200-001-10 22 M83383/04-10 SM601BA60A1 34 42 4001-011-2 SAFRAN ELECTRICAL & POWER "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." ELECTRIC DISTRIBUTION & CONTROLS Product Application Information and Warranty Disclaimer It is buyer's responsibility to determine the suitability of the particular device for its application, and Safran Electrical & Power makes no warranties, and assumes no liability as to the suit-ability of sufficiency for buyer's application of the device. Ratings and switch performance are valid only on devices which have not been subjected to unauthorized modifications or misapplications. Dimensional drawings are available upon request. Notice The use of Safran Electrical & Power devices should be in accordance with the provisions of the National Electric Code, U.L. and/or other local, military or industry standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment. Government Cage Code The Government Cage Codes for electrical power management products manufactured by Safran Electrical & Power are 81640 and76374. "Safran Electrical & Power Proprietary Information. Information contained in this document is Safran Electrical & Power Proprietary Information and is disclosed in confidence. It is the property of Safran Electrical & Power and shall not be used, disclosed to others, or reproduced without the express written agreement of Safran Electrical & Power. If consent is given for reproduction in whole or in part, this notice set forth on each page of this document shall appear in any such reproduction in whole or in part. Unauthorized export or re-export is prohibited." 43 Local contact (Sarasota, FL): SAFRAN ELECTRICAL & POWER 2250 Whitfield Avenue Sarasota, FL 34243 USA Tel. 1-800-955-7354 Fax 941-751-7173 TechnicalSupport.SRQ@SafranGroup.com SAFRAN ELECTRICAL & POWER Headquarters : 36 rue Raymond Grimaud 31700 BLAGNAC - FRANCE Tel. +33 (0)5 34 60 00 00 - Fax +33 (0)5 34 60 01 99 www.safran-electrical-power.com