Technical Data System pro M System pro M compact(R) Miniature Circuit-Breakers for Railway Applications Railway application prEN 45545-1 Level HL4 220/440 V DC 230/400 V AC 60 V DC 230/400 V AC 1. Fire Resistance Miniature circuit-breakers of the S 200 P and S 280 UC series, including auxiliary contacts and busbars, comply with hazard Level HL 4 according to NF F16-101/-102, prEN 45545-1/-2. 2. Shock and vibration resistance S 200 P and S 280 UC Shock and vibration tests carried out pursuant to DIN IEC 60068, DIN EN 50155/EN 61373 (railway application) fulfilled in all directions. Contact stability of auxiliary contacts at 24 V DC, 4 mA Automatic reclosing permissible below 10 ms Standard Terms for Delivery and Sale For domestic business, the Standard Terms for Delivery of Products and Services of the Electrical Industry (ABB Form 2292) shall apply in connection with the Standard Sales Terms (ABB Form 2327) in their then applicable version. For foreign business, the Standard Terms for Delivery of Products and Services of the Electrical Industry (ABB Form 2293 German-English, or ABB Form 2294 German-French) shall apply in connection with the Standard Sales Terms (ABB-Form 2381 English) in their then applicable version. Warranty We assume warranty in accordance with the standard sales and delivery terms. Complaints shall be made in writing within eight days following receipt of the goods. Technical information and illustrations are not binding and subject to change without notice. Contents Title General Part for S 200 P and 280 UC Conformity: Fire resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conformity: Vibration / shock test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tripping behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Influence of ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interdependencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Projecting notes: - Socket-outlet circuits 230 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Control circuits 24 V DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Selection rated current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System pro M compact S 200 P series for 230/400 V AC and 60 V DC circuits Special features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selection tables: - S 200 P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Additional devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Busbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data S 200 P: - Switching capacity / back up protection . . . . . . . . . . . . . . . . . . - Internal resistance, power loss . . . . . . . . . . . . . . . . . . . . . . . . . - Let-through integrals at 230/400 V AC . . . . . . . . . . . . . . . . . . . - Let-through integrals at 60 V DC . . . . . . . . . . . . . . . . . . . . . . . . Dimension drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuits drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation and operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System pro M S 280 UC series for 230/400 V AC and 220, 440 V DC Special features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selection tables: - S 280 UC-B, K, Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Additional devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Busbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data S 280 UC-B, K, Z - Switching capacity/back up protection . . . . . . . . . . . . . . . . . . . - Internal resistance, power loss . . . . . . . . . . . . . . . . . . . . . . . . . - Let-through integrals at 230/400 V AC . . . . . . . . . . . . . . . . . . . Dimension drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection drawings and examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation and operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 2 5 6 8 8 9 11 14 15 19 22 23 24 28 29 30 31 32 32 33 34 36 39 40 42 50 51 51 52 52 54 3 Contents Title System pro M compact S 200 U series for 230/400 V AC and 60 V DC circuits Special features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selection tables: - S 200 U-K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - S 200 U-Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - S 200 UP-K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - S 200 UP-Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories for S 200 U/S 200 UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data S 200 U/S 200 UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimension drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Busbars and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 page 55 56 57 59 61 62 63 64 65 68 69 Miniature circuit-breakers Protection objectives Description Miniature circuit-breakers of the S 200 P series have a current-limiting effect. They have two different trip releases acting on the contact mechanism: 1. the delayed thermal release providing overload protection 2. the electromechanical instantaneous release with "hammer trip" solenoid providing short-circuit protection. They offer: high short-circuit capacity high selectivity for back-up protection low loads in the case of a short circuit on the line and/or the damaged area through massive limitation of the let-through 2t/A2s (ohmic thermal figure) Task Protection against excessive temperature rises of electric items in the case of overcurrents caused by overload, short circuit or earth-fault current if assigned according to DIN VDE 0100 Part 430. Protection against electric shock in the case of excessive touch voltage caused by insulation fault if assigned according to DIN VDE 0100 Part 410. SK 0130 Z 98 Oscillogram of a disconnection procedure IK * 2 = Peak value of prospective fault current iD = Max. let-through current of device S 200/S 200 M Un = Supply voltage UB = Build-up and collapse of arc voltage of device tK = Operating time of device 5 Miniature circuit-breakers S 200 P and S 280 UC series Tripping behavior S 200 P series according to standard Tripping characteristic and rated currents DIN EN 60 898 (VDE 0641 Part 11) B 6 to 63 A DIN EN 60 947-2 (VDE 0660 Part 101) K 0.2 to 63 A DIN EN 60 947-2 (VDE 0660 Part 101) Z 0.5 to 63 A Thermal tripping conventional: Tripping time trip. current non-conventional trip. current I1 I2 test current 1.13 * In >1h <1h 3 * In 1.45 * In >1h <1h < 2 min. > 2 s (T1) 10 * In 1.2 * In 1.5 * In 6.0 * In >1h <1h < 2 min. > 2 s (T1) 2 * In 1.05 * In 1.05 * In 1.2 * In 1.5 * In 6.0 * In The indicated tripping values of electromagnetic tripping devices apply to a frequency range from 162/3 ... 60 Hz. In the case of diverging frequencies or direct current, the values change by the factor indicated below: factor ca. 100 Hz Alternating current 200 Hz 400 Hz 1.1 1.2 1.5 Electromagnetic tripping test current: hold current switch rushes latest from off at Direct current Tripping time 0.1 ... 45 s 32 A/0.1 ... 90 s > 32 A < 0.1 s 5 * In > 0.2 s < 0.2 s 14 * In 3 * In > 0.2 s < 0.2 s The thermal releases are calibrated to a nominal reference ambient temperature; for Z and K, the value is 20 C/68F, for B and C = 30 C/86 F In the case of higher ambient temperatures, the current values fall by ca. 6 % for each 10 K temperature rise. as from operating temperature (after I1 > 1 h or 2 h, respectively). 1.5 The thermal release operates independent of the frequency. Tripping behavior S 280 UC series S 280 UC according to standard Thermal tripping Tripping characteristic and test currents Tripping time range of rated current conventional non-conventional trip. current trip. current I2 I1 DIN EN 60 898 B (VDE 0641 Part 12) 6 to 25 A DIN EN 60 947-2 K (VDE 0660 Part 101) 0.2 to 63 A DIN EN 60 947-2 Z (VDE 0660 Part 101) 0.5 to 63 A Electromagnetic tripping Test current hold current switch rushes from latest off at ... at ~ 3 * In 1.45 * In >1h <1h >1h <1h < 2 min > 2 s (T1) 10 * In 1.2 * In 1.5 * In 6.0 * In >1h <1h < 2 min 2 * In 1.2 * In 1.5 * In 1.13 * In 1.05 * In 1.05 * In The max. permissible operating currents depend on the following factors: ambient temperature and mutual thermal influence. See page 13. The indicated tripping values of electromagnetic tripping devices apply to a frequency range from 162/3 ... 60 Hz. In the case of diverging frequencies or direct current, the values change by the factor indicated in the table below. as from operating temperature (after I1 > 1 h) Alternating current factor ca. 100 Hz 200 Hz 400 Hz 1.1 1.2 1.5 The thermal release operates independent of the frequency. 6 DC ca. 1.5 rated current S 280 UC-Z Tripping time at - at ~ at - 5 * In 7.5 * In > 0.1 s < 0.1 s > 0.1 s < 0.1 s 14 * In 21 * In > 0.2 s < 0.2 s > 0.2 s < 0.2 s 3 * In 4.5 * In > 0.2 s < 0.2 s > 0.2 s < 0.2 s hold switch non-delayed at current rushes AC/DC DC 48 % 5% from ripple ripple 0.5 A 1A 1.6 A 1A 2A 3.2 A 1.5 A 3.0 A 4.8 A 2.4 A 4.8 A 7.7 A 2A 3A 4A 4A 6A 8A 6A 9A 12 A 9A 15 A 19 A 6A 8A 10 A 12 A 16 A 20 A 18 A 24 A 30 A 29 A 38 A 48 A 16 A 20 A 25 A 32 A 40 A 50 A 48 A 60 A 75 A 77 A 96 A 120 A 32 A 40 A 50 A 64 A 80 A 100 A 96 A 120 A 150 A 153 A 192 A 240 A 63 A 125 A 189 A 315 A Tripping characteristics for MCBs Assignment Summary Compared to tripping characteristics "B", "C" and "D", the "K" and "Z" types offer more protection for planning and during operation. Assignment "B" and "C" according to VDE 0641 Part 11 DIN EN 60898 and IEC 898 for overcurrent protection of lines SK 0219 Z 00 Tripping Characteristic: Z, K according to VDE 0660 Part 101 DIN EN 60947-2 and IEC 947-2 Design requirements for miniature circuit-breakers SK 0217 Z 00 Tripping Characteristic: B, C, D according to VDE 0641 Part 11 DIN EN 60898 and IEC 898 Design requirements for circuit-breakers for overcurrent protection for household and similar installations "K" according to VDE 0660 Part 101 DIN EN 60947-2 and IEC 947-2 for overcurrent protection of lines for current circuits where current-consuming apparatus causes functional current peaks "Z" according to VDE 0660 Part 101 DIN EN 60947-2 and IEC 947-2 for overcurrent protection of lines for control circuits with high impedances, yet without functional peaks voltage transformer circuits semiconductor protection with selected assignment 7 Miniature circuit-breakers S 200 P and S 280 UC series Max. operating current depending on the ambient temperature of a circuit-breaker in load circuit of characteristics type B and C B and C In (A) 0.5 1.0 1.6 2.0 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 - 40 -30/-22 - 20/-4 0.67 0.65 0.62 1.33 1.29 1.25 2.13 2.07 2.00 2.67 2.58 2.49 4.0 3.9 3.7 5.3 5.2 5.0 8.0 7.7 7.5 10.7 10.3 10.0 13.3 12.9 12.5 17.3 16.8 16.2 21.3 20.7 20.0 26.7 25.8 24.9 33.3 32.3 31.2 42.7 41.3 39.9 53.3 51.6 49.9 66.7 64.5 62.4 84.0 81.3 78.6 - 10/14 0.60 1.20 1.92 2.40 3.6 4.8 7.2 9.6 12.0 15.6 19.2 24.0 30.0 38.5 48.1 60.1 75.7 Ambient temperature T (C/F) 0/32 10/50 20/68 30/86 0.58 0.55 0.53 0.50 1.15 1.11 1.05 1.00 1.85 1.77 1.69 1.60 2.31 2.21 2.11 2.00 3.5 3.3 3.2 3.0 4.6 4.4 4.2 4.0 6.9 6.6 6.3 6.0 9.2 8.8 8.4 8.0 11.5 11.1 10.5 10.0 15.0 14.4 13.7 13.0 18.5 17.7 16.9 16.0 23.1 22.1 21.1 20.0 28.9 27.6 26.4 25.0 37.0 35.4 33.7 32.0 46.2 44.2 42.2 40.0 57.7 55.3 52.7 50.0 72.7 69.6 66.4 63.0 40/104 0.47 0.94 1.51 1.89 2.8 3.8 5.7 7.5 9.4 12.3 15.1 18.9 23.6 30.2 37.7 47.1 59.4 50/122 0.44 0.88 1.41 1.76 2.6 3.5 5.3 7.1 8.8 11.5 14.1 17.6 22.0 28.2 35.3 44.1 55.6 60/140 0.41 0.82 1.31 1.63 2.4 3.3 4.9 6.5 8.2 10.6 13.1 16.3 20.4 26.1 32.7 40.8 51.4 70/158 0.37 0.75 1.19 1.49 2.2 3.0 4.5 6.0 7.5 9.7 11.9 14.9 18.6 23.9 29.8 37.3 47.0 60/140 0.35 0.71 1.13 1.41 2.1 2.8 4.2 5.7 7.1 9.2 11.3 14.1 17.7 22.6 28.3 35.4 44.5 70/158 0.31 0.61 0.98 1.22 1.8 2.4 3.7 4.9 6.1 8.0 9.8 12.2 15.3 19.6 24.5 30.6 38.6 Max. operating current depending on the ambient temperature of a circuit-breaker in load circuit of characteristics type K and Z K and Z In (A) 0.5 1.0 1.6 2.0 3.0 4.0 6.0 8.0 10.0 13.0 16.0 20.0 25.0 32.0 40.0 50.0 63.0 - 40 -30/-22 - 20/-4 0.66 0.64 0.61 1.32 1.27 1.22 2.12 2.04 1.96 2.65 2.55 2.45 4.0 3.8 3.7 5.3 5.1 4.9 7.9 7.6 7.3 10.8 10.2 9.8 13.2 12.7 12.2 17.2 16.6 15.9 21.2 20.4 19.6 26.5 25.5 24.5 33.1 31.9 30.6 42.3 40.8 39.2 52.9 51.0 49.0 66.1 63.7 61.2 83.3 80.3 77.2 - 10/14 0.59 1.17 1.88 2.35 3.5 4.7 7.0 9.4 11.7 15.2 18.8 23.5 29.3 37.5 46.9 58.6 73.9 Ambient temperature T (C/F) 0/32 10/50 20/68 30/86 0.56 0.53 0.50 0.47 1.12 1.06 1.00 0.94 1.79 1.70 1.60 1.50 2.24 2.12 2.00 1.87 3.4 3.2 3.0 2.8 4.5 4.2 4.0 3.7 6.7 6.4 6.0 5.6 8.9 8.5 8.0 7.5 11.2 10.6 10.0 9.4 14.5 13.8 13.0 12.2 17.9 17.0 16.0 15.0 22.4 21.2 20.0 18.7 28.0 26.5 25.0 23.4 35.8 33.9 32.0 29.9 44.7 42.4 40.0 37.4 55.9 53.0 50.0 46.8 70.4 66.8 63.0 58.9 40/104 0.43 0.87 1.39 1.73 2.6 3.5 5.2 6.9 8.7 11.3 13.9 17.3 21.7 27.7 34.6 43.3 54.6 50/122 0.40 0.79 1.26 1.58 2.4 3.2 4.7 6.3 7.9 10.3 12.6 15.8 19.8 25.3 31.6 39.5 49.8 Interdependencies in the case of even loads A correction factor must be taken into account in the case of closely butt-mounted devices and simultaneous high load: 2 and 3 miniature circuit-breakers with factor 0.9; 4 and 5 miniature circuit-breakers with factor 0.8; 6 and more miniature circuit-breakers with factor 0.75 The interdependency becomes irrelevant if FST ... filler pieces (9 mm width) are used. 8 Miniature circuit-breakers S 200 P and S 280 UC series Protection against electric shock DIN VDE 0100-410. Maximum length of lines in socket-outlets 230/400 V Internal resistance of MCBs which, at In 6 A, have a high significance. 1. For the determination of the max. length of lines, relevant factors have been taken into account. The maximum lengths do not need to be taken into account if protection from indirect touch is provided by an RCD. Resistance value of the copper conductor at 70 C/158 F operating temperature. 2. Voltage drop If the voltage drop is not to exceed 3%, the max. length of the 2-stranded cable must not be longer than 17 m. The voltage drop is a relevant factor. Example: a cable with cross section of 1.5 mm2 is protected by a B16 circuit-breaker. According to table 3, the max. length of the cable is 82 m. Operating Max. perm. length of cables and lines lmax in m current nominal capacity in mm2 A 1.5 2.5 6 92 150 10 55 90 4 6 141 34 56 88 132 20 28 45 70 106 85 142 60 101 160 53 89 140 50 71 112 63 56 89 35 40 80 36 16 1% 1.5% 16 25 10 Voltage drop 56 40 Factor 0.33 0.5 4% 1.33 5% 1.67 8% 2.67 10% 3.33 Table 2: Conversion factors for max. perm. lengths of cables and lines lmax in the case of voltage drops of 3%. 70 Table 1: Maximum length of cables and lines lmax at a voltage drop of 3%. Conductor temperature 30C/86 F, three-phase circuits, nominal voltage of the installation 400 V, 50 Hz. For single-phase AC circuits, 230 V, lengths have to be multiplied by 0.5. 9 Miniature circuit-breakers S 200 P and S 280 UC series Maximum permissible length of cables and lines Imax when operation conditions are fulfilled Important: Always take Imax into account due to max. voltage drop! Maximal zulassige Kabelund Leitungslangen l max bei Einhaltung der Abschaltbedingungen (determined in line with DIN VDE 0100-520 Bbl2: 2002-11) Achtung: zusatzlich immer l max aufgrund max Spannungsfall beachten! (ermittelt in Anlehnung an DIN VDE 0100-520 Bbl2 :2002-11) 0,14 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16 internal resistanceLS MCB Innenwiderstand Char. Char.ZZ internal resistanceLS MCB Innenwiderstand Char. Char.KK internal resistanceLS MCB Innenwiderstand Char.CC Char. Innenwiderstand internal resistanceLS MCB Char.BB Char. mm Bemessungsstrom operating current In In conductor nominal capacity Leiternennquerschnitt For series S 200 P, S 280 UC, the max. line lengths have to be reduced by the factor 0.86. Note: The maximum lenght does not need Hinweis: Die Grenzlangen brauchen nicht to be taken into account if protection from beachtet werden, wenn der Schutz bei indirect touch is provided by RCDs. indirektem Beruhren durch eine Fehlerstrom-Schutzeinrichtung sichergestellt wird. A A m A m A m A m A m 0,5 - 5,5000 6,3400 10,1000 2,5 - - 5,0 46,19 134 7,0 32,99 95 6,0 38,49 111 1,5 153,96 452 DINVDE VDE0641-11 0641-11(VDE Teil11) MCBLS-Schalter accordingnach to DIN (VDE0641 0641 Part 11) und DIN EN60898-2 60898-2(VDE (VDE 0641 0641 Teil and DIN EN Part12) 12) 0,4s; s; ttaa = 5s tata==0.4 5s (is achieved instantaneous disconnection (wird through erreicht durch Schnellabschaltung t 0,1 ts) 0.1 s) S200/S200M S200/S200M Type B Typ B S200/S200M S200/S200M Type C Typ C Ierf Zs lmax Ierf Zs lmax S200/S200M S200/S200M Type D Typ D Ierf Zs S200 S200 Type K Typ K lmax Ierf Zs S200 S200 Type Z Typ Z lmax Ierf Zs 1 - 1,4400 1,5500 2,2700 5,0 - - 10,0 23,09 67 14,0 16,50 48 12,0 19,25 56 3,0 76,98 226 1,6 - 0,6300 0,6950 1,1000 8,0 - - 16,0 14,43 42 22,4 10,31 29 19,2 12,03 35 4,8 48,11 141 2 - 0,4600 0,4600 0,6190 10,0 - - 20,0 11,55 33 28,0 8,25 23 24,0 9,62 27 6,0 38,49 113 0,5 - 5,5000 6,3400 10,1000 2,5 - - 5,0 46,19 240 7,0 32,99 169 6,0 38,49 198 1,5 153,96 807 1,0 - 1,4400 1,5500 2,2700 5,0 - - 10,0 23,09 120 14,0 16,50 85 12,0 19,25 99 3,0 76,98 403 1,6 - 0,6300 0,6950 1,1000 8,0 - - 16,0 14,43 74 22,4 10,31 53 19,2 12,03 62 4,8 48,11 252 2 - 0,4600 0,4600 0,6190 10,0 - - 20,0 11,55 59 28,0 8,25 42 24,0 9,62 49 6,0 38,49 201 3 - 0,1500 0,1650 0,2020 15,0 - - 30,0 7,70 39 42,0 5,50 27 36,0 6,42 32 9,0 25,66 134 1 - 1,4400 1,5500 2,2700 5,0 - - 10,0 23,09 163 14,0 16,50 116 12,0 19,25 135 3,0 76,98 548 1,6 - 0,6300 0,6950 1,1000 8,0 - - 16,0 14,43 101 22,4 10,31 72 19,2 12,03 84 4,8 48,11 342 2 - 0,4600 0,4600 0,6190 10,0 - - 20,0 11,55 81 28,0 8,25 57 24,0 9,62 67 6,0 38,49 273 3 - 0,1500 0,1650 0,2020 15,0 - - 30,0 7,70 53 42,0 5,50 37 36,0 6,42 44 9,0 25,66 182 4 - 0,1100 0,1200 0,1490 20,0 - - 40,0 5,77 39 56,0 4,12 27 48,0 4,81 32 12,0 19,25 136 1,6 - 0,6300 0,6950 1,1000 8,0 - - 16,0 14,43 149 22,4 10,31 105 19,2 12,03 123 4,8 48,11 503 2 - 0,4600 0,4600 0,6190 10,0 - - 20,0 11,55 118 28,0 8,25 84 24,0 9,62 98 6,0 38,49 402 3 - 0,1500 0,1650 0,2020 15,0 - - 30,0 7,70 78 42,0 5,50 55 36,0 6,42 65 9,0 25,66 267 4 - 0,1100 0,1200 0,1490 20,0 - - 40,0 5,77 58 56,0 4,12 40 48,0 4,81 48 12,0 19,25 200 6 0,0550 0,0550 0,0520 0,1040 30,0 7,70 78 60,0 3,85 38 84,0 2,75 26 72,0 3,21 31 18,0 12,83 132 2 - 0,4600 0,4600 0,6190 10,0 - - 20,0 11,55 178 28,0 8,25 126 24,0 9,62 147 6,0 38,49 603 3 - 0,1500 0,1650 0,2020 15,0 - - 30,0 7,70 117 42,0 5,50 82 36,0 6,42 97 9,0 25,66 401 4 - 0,1100 0,1200 0,1490 20,0 - - 40,0 5,77 87 56,0 4,12 61 48,0 4,81 71 12,0 19,25 299 6 0,0550 0,0550 0,0520 0,1040 30,0 7,70 117 60,0 3,85 56 84,0 2,75 39 72,0 3,21 46 18,0 12,83 198 10 0,0133 0,0133 0,0126 0,0175 50,0 4,62 68 100,0 2,31 32 140,0 1,65 22 120,0 1,92 26 30,0 7,70 117 3 - 0,1500 0,1650 0,2020 15,0 - - 30,0 7,70 156 42,0 5,50 110 36,0 6,42 129 9,0 25,66 534 4 - 0,1100 0,1200 0,1490 20,0 - - 40,0 5,77 116 56,0 4,12 81 48,0 4,81 95 12,0 19,25 399 6 0,0550 0,0550 0,0520 0,1040 30,0 7,70 156 60,0 3,85 75 84,0 2,75 52 72,0 3,21 62 18,0 12,83 264 10 0,0133 0,0133 0,0126 0,0175 50,0 4,62 91 100,0 2,31 43 140,0 1,65 29 120,0 1,92 35 30,0 7,70 156 13 0,0133 0,0133 0,0126 - 65,0 3,55 69 130,0 1,78 31 182,0 1,27 21 156,0 1,48 25 - - 16 0,0070 0,0070 0,0077 0,0109 80,0 2,89 55 160,0 1,44 24 224,0 1,03 16 192,0 1,20 19 48,0 4,81 95 4 - 0,1100 0,1200 0,1490 20,0 - - 40,0 5,77 173 56,0 4,12 121 48,0 4,81 143 12,0 19,25 599 6 0,0550 0,0550 0,0520 0,1040 30,0 7,70 234 60,0 3,85 113 84,0 2,75 78 72,0 3,21 92 18,0 12,83 396 10 0,0133 0,0133 0,0126 0,0175 50,0 4,62 137 100,0 2,31 64 140,0 1,65 43 120,0 1,92 52 30,0 7,70 234 13 0,0133 0,0133 0,0126 - 65,0 3,55 103 130,0 1,78 47 182,0 1,27 31 156,0 1,48 38 - - 16 0,0070 0,0070 0,0077 0,0109 80,0 2,89 82 160,0 1,44 37 224,0 1,03 23 192,0 1,20 29 48,0 4,81 20 0,0063 0,0063 0,0067 0,0060 100,0 2,31 64 200,0 1,15 27 280,0 0,82 17 240,0 0,96 21 60,0 3,85 113 6 0,0550 0,0550 0,0520 0,1040 30,0 7,70 389 60,0 3,85 187 84,0 2,75 129 72,0 3,21 153 18,0 12,83 658 10 0,0133 0,0133 0,0126 0,0175 50,0 4,62 227 100,0 2,31 106 140,0 1,65 72 120,0 1,92 86 30,0 7,70 389 13 0,0133 0,0133 0,0126 - 65,0 3,55 172 130,0 1,78 78 182,0 1,27 51 156,0 1,48 63 - - 16 0,0070 0,0070 0,0077 0,0109 80,0 2,89 137 160,0 1,44 61 224,0 1,03 39 192,0 1,20 48 48,0 4,81 238 20 0,0063 0,0063 0,0067 0,0060 100,0 2,31 106 200,0 1,15 45 280,0 0,82 28 240,0 0,96 35 60,0 3,85 187 25 0,0050 0,0050 0,0046 0,0041 125,0 1,85 82 250,0 0,92 33 350,0 0,66 19 300,0 0,77 25 75,0 3,08 147 10 0,0133 0,0133 0,0126 0,0175 50,0 4,62 364 100,0 2,31 170 140,0 1,65 114 120,0 1,92 137 30,0 7,70 622 13 0,0133 0,0133 0,0126 - 65,0 3,55 274 130,0 1,78 125 182,0 1,27 82 156,0 1,48 100 - - 16 0,0070 0,0070 0,0077 0,0109 80,0 2,89 218 160,0 1,44 97 224,0 1,03 62 192,0 1,20 77 48,0 4,81 380 20 0,0063 0,0063 0,0067 0,0060 100,0 2,31 170 200,0 1,15 73 280,0 0,82 45 240,0 0,96 56 60,0 3,85 299 25 0,0050 0,0050 0,0046 0,0041 125,0 1,85 131 250,0 0,92 53 350,0 0,66 31 300,0 0,77 40 75,0 3,08 234 32 0,0036 0,0036 0,0035 0,0028 160,0 1,44 97 320,0 0,72 36 448,0 0,52 18 384,0 0,60 25 96,0 2,41 178 13 0,0133 0,0133 0,0126 - 65,0 3,55 413 130,0 1,78 188 182,0 1,27 124 156,0 1,48 151 - - 16 0,0070 0,0070 0,0077 0,0109 80,0 2,89 329 160,0 1,44 146 224,0 1,03 94 192,0 1,20 115 48,0 4,81 572 20 0,0063 0,0063 0,0067 0,0060 100,0 2,31 256 200,0 1,15 109 280,0 0,82 67 240,0 0,96 85 60,0 3,85 450 25 0,0050 0,0050 0,0046 0,0041 125,0 1,85 197 250,0 0,92 80 350,0 0,66 46 300,0 0,77 60 75,0 3,08 353 32 0,0036 0,0036 0,0035 0,0028 160,0 1,44 146 320,0 0,72 54 448,0 0,52 27 384,0 0,60 38 96,0 2,41 268 40 0,0030 0,0030 0,0028 0,0025 200,0 1,15 109 400,0 0,58 35 560,0 0,41 13 480,0 0,48 23 120,0 1,92 207 25 0,0050 0,0050 0,0046 0,0041 125,0 1,85 330 250,0 0,92 134 350,0 0,66 77 300,0 0,77 101 75,0 3,08 591 32 0,0036 0,0036 0,0035 0,0028 160,0 1,44 245 320,0 0,72 90 448,0 0,52 45 384,0 0,60 64 96,0 2,41 449 40 0,0030 0,0030 0,0028 0,0025 200,0 1,15 183 400,0 0,58 59 560,0 0,41 22 480,0 0,48 38 120,0 1,92 347 50 0,0013 0,0013 0,0013 0,0018 250,0 0,92 134 500,0 0,46 34 700,0 0,33 3 600,0 0,38 16 150,0 1,54 265 63 0,0012 0,0012 0,0007 0,0013 315,0 0,73 93 630,0 0,37 12 882,0 0,26 0 756,0 0,31 0 189,0 1,22 198 32 0,0036 0,0036 0,0035 0,0028 160,0 1,44 389 320,0 0,72 144 448,0 0,52 72 384,0 0,60 102 96,0 2,41 713 40 0,0030 0,0030 0,0028 0,0025 200,0 1,15 291 400,0 0,58 94 560,0 0,41 36 480,0 0,48 60 120,0 1,92 551 50 0,0013 0,0013 0,0013 0,0018 250,0 0,92 213 500,0 0,46 53 700,0 0,33 5 600,0 0,38 26 150,0 1,54 421 63 0,0012 0,0012 0,0007 0,0013 315,0 0,73 147 630,0 0,37 19 882,0 0,26 0 756,0 0,31 0 189,0 1,22 314 Impedancy before the overcurrent protective device Zv = 300 m; c = 0.95; conductor temperature 70 C / 158 F = factor; 0.8 (DIN VDE 0100 - 520 Bbl5) and typical line impedance is included, additionally, internal resistance LS has been taken in account. 10 lmax 143 Miniature circuit-breakers S 200 P and S 280 UC series Protection of sensitive components and fire protection in control circuits 24 V DC, EN 60204 - 1 To comply with the standard and provide adequate protection of sensitive components, e.g. contacts, pre-cut lines for sensors/position switches the following must be ensured: Projecting note: In the case of overcurrent, the non-delayed trip release must respond within milliseconds, thereby ensuring that the I2t value on the component is as small as possible. To ensure a safe functioning of the non-delayed trip release, it is necessary to observe the maximum line length with respect to loop resistance. The calculation parameters are: Loop resistance (Ri + Rcu) Ri = Internal resistance of circuit-breaker at 20 C/68F RL = Line resistance at 20 C/68F - Copper temperature: 80 C/176 F in the case of a short circuit - Voltage drop - Contact resistance SK 0146 Z 00 This results in an overall reduction factor of 2/3 (DIN VDE 0100-610 April 2004) 11 Miniature circuit-breakers S 200 P and S 280 UC series Example 1: Standard power supply unit S 201 P - Z2 S 201 P - K2 2CDC 022 152 F0005 Ri = 0.62 40 m = 0.48 RL= : 1.5 x 56 R = (0.62 + 0.48) = 1.1 IK= 24 V x 2/3 1.1 = 14.5 A Undelayed response value for S 201 P- Z 2 = 4.5 In = 9 A Result: Trips within milliseconds Example 2: Switched mode power supply unit S 201 P - Z2 S 201 P - K2 2CDC 022 153 F0005 S 201 P takes < 0.1 s for non-delayed tripping. If the switched-mode power supply unit regulates down if a short-circuit occurs, then the power supply unit will respond faster than the S 201-... may trip. Consequence: No selective fault recognition Result: The output of the switched mode power supply unit must be delayed ( 100 ms) and the protective device must be adapted to the delayed value to obtain selective fault recognition. 12 Maximum permissible length of cables and lines for the protection of damageable building components and fire protection EN 204-1 MaximalImportant: zulassigeAlways Kabel-take und Leitungslangen Schutz Imax into account due zum to max. voltageempfindlicher drop! Bauelemente und Brandschutz EN 60204 - 1 Achtung: zusatzlich immer l max aufgrund max.Spannungsfall beachten ! Ausloser sichergestellt. 0,25 0,34 0,5 0,75 1 1,5 2,5 4 6 10 16 internal resistance MCB Innenwiderstand LS Char.Z Char. Z Innenwiderstand LS internal resistance MCB Char.C Char. C internal resistance MCB Innenwiderstand LS Char.B Char. B 0,14 operating current InIn Bemessungsstrom conductor nominal Leiternennquerschnitt capacity For the S 200 P, S 280 UC series the max. length of lines shall be reduced by the factor 0.86. mm Note: The Imax provide for additional Hinweis: Dieofl damageable max-Werte stellen den zusatzlichen protection components. Schutz empfindlicher Bauelemente sicher. In the case of Imax = 0: the sole overcurrent 0:the ist in jedem Fall der alleinige Bei l max =of protection lines is provided by the Uberstromschutz delayed release. der Leitung uber den verzogerten A A m A m A 0,5 - 5,5000 10,1000 3,8 - - 7,5 2,43 0 2,3 8,11 0 1 - 1,4400 2,2700 7,5 - - 15,0 1,22 0 4,5 4,05 6 1,6 - 0,6300 1,1000 12,0 - - 24,0 0,76 0 7,2 2,53 4 2 - 0,4600 0,6190 15,00 - - 30,0 0,61 0 9,0 2,03 4 0,5 - 5,5000 10,1000 3,8 - - 7,5 2,43 0 2,3 8,11 0 1,0 - 1,4400 2,2700 7,5 - - 15,0 1,22 0 4,5 4,05 10 1,6 - 0,6300 1,1000 12,0 - - 24,0 0,76 0 7,2 2,53 8 2 - 0,4600 0,6190 15,0 - - 30,0 0,61 1 9,0 2,03 8 3 - 0,1500 0,2020 22,5 - - 45,0 0,41 1 13,5 1,35 6 1 - 1,4400 2,2700 7,5 - - 15,0 1,22 0 4,5 4,05 14 1,6 - 0,6300 1,1000 12,0 - - 24,0 0,76 1 7,2 2,53 11 2 - 0,4600 0,6190 15,0 - - 30,0 0,61 1 9,0 2,03 11 3 - 0,1500 0,2020 22,5 - - 45,0 0,41 2 13,5 1,35 9 4 - 0,1100 0,1490 30,0 - - 60,0 0,30 1 18,0 1,01 6 1,6 - 0,6300 1,1000 12,0 - - 24,0 0,76 1 7,2 2,53 16 2 - 0,4600 0,6190 15,0 - - 30,0 0,61 1 9,0 2,03 16 3 - 0,1500 0,2020 22,5 - - 45,0 0,41 2 13,5 1,35 13 4 - 0,1100 0,1490 30,0 - - 60,0 0,30 2 18,0 1,01 9 6 0,0550 0,0550 0,1040 45,0 0,41 3 90,0 0,20 1 27,0 0,68 6 2 - 0,4600 0,6190 15,0 - - 30,0 0,61 2 9,0 2,03 23 3 - 0,1500 0,2020 22,5 - - 45,0 0,41 4 13,5 1,35 19 4 - 0,1100 0,1490 30,0 - - 60,0 0,30 2 18,0 1,01 14 9 MCB according DIN VDE VDE0641 0641-11 LS-Schalter nachto DIN - 11 and VDE VDE 0660 0660 -Part und Teil 101 101 tta a << 0.1 0,1 ss S200/S200M S200/S200M Type B Typ B S200/S200M S200/S200M Type C Typ C Ierf Zs lmax Ierf S200 S200 Type Z Typ Z Zs lmax Ierf Zs lmax m 6 0,0550 0,0550 0,1040 45,0 0,41 5 90,0 0,20 2 27,0 0,68 10 0,0133 0,0133 0,0175 75,0 0,24 3 150,0 0,12 1 45,0 0,41 6 3 - 0,1500 0,2020 22,5 - - 45,0 0,41 5 13,5 1,35 25 4 - 0,1100 0,1490 30,0 - - 60,0 0,30 3 18,0 1,01 19 6 0,0550 0,0550 0,1040 45,0 0,41 7 90,0 0,20 2 27,0 0,68 12 10 0,0133 0,0133 0,0175 75,0 0,24 4 150,0 0,12 1 45,0 0,41 8 13 0,0133 0,0133 97,5 0,19 3 195,0 0,09 58,5 0,31 16 0,0070 0,0070 0,1090 120,0 0,15 2 240,0 0,08 0 72,0 0,25 2 2 - 0,4600 0,6190 15,0 - - 30,0 0,61 3 9,0 2,03 47 28 4 - 0,1100 0,1490 30,0 - - 60,0 0,30 5 18,0 1,01 6 0,0550 0,0550 0,1040 45,0 0,41 10 90,0 0,20 3 27,0 0,68 18 10 0,0133 0,0133 0,0175 75,0 0,24 6 150,0 0,12 2 45,0 0,41 12 13 0,0133 0,0133 97,5 0,19 4 195,0 0,09 1 58,5 0,31 16 0,0070 0,0070 0,1090 120,0 0,15 3 240,0 0,08 1 72,0 0,25 3 20 0,0063 0,0063 0,0060 150,0 0,12 2 300,0 0,06 0 90,0 0,20 5 6 0,0550 0,0550 0,1040 45,0 0,41 17 90,0 0,20 6 27,0 0,68 30 10 0,0133 0,0133 0,0175 75,0 0,24 10 150,0 0,12 3 45,0 0,41 19 13 0,0133 0,0133 97,5 0,19 7 195,0 0,09 2 58,5 0,31 16 0,0070 0,0070 0,1090 120,0 0,15 5 240,0 0,08 1 72,0 0,25 5 20 0,0063 0,0063 0,0060 150,0 0,12 4 300,0 0,06 0 90,0 0,20 8 25 0,0050 0,0050 0,0041 187,5 0,10 2 375,0 0,05 0 112,5 0,16 6 10 0,0133 0,0133 0,0175 75,0 0,24 17 150,0 0,12 5 45,0 0,41 31 13 0,0133 0,0133 97,5 0,19 11 195,0 0,09 3 58,5 0,31 16 0,0070 0,0070 0,1090 120,0 0,15 9 240,0 0,08 2 72,0 0,25 9 20 0,0063 0,0063 0,0060 150,0 0,12 6 300,0 0,06 0 90,0 0,20 13 25 0,0050 0,0050 0,0041 187,5 0,10 4 375,0 0,05 0 112,5 0,16 10 32 0,0036 0,0036 0,0028 240,0 0,08 2 480,0 0,04 0 144,0 0,13 7 13 0,0133 0,0133 97,5 0,19 17 195,0 0,09 4 58,5 0,31 16 0,0070 0,0070 0,1090 120,0 0,15 13 240,0 0,08 3 72,0 0,25 13 20 0,0063 0,0063 0,0060 150,0 0,12 9 300,0 0,06 1 90,0 0,20 20 25 0,0050 0,0050 0,0041 187,5 0,10 6 375,0 0,05 0 112,5 0,16 15 32 0,0036 0,0036 0,0028 240,0 0,08 3 480,0 0,04 0 144,0 0,13 10 40 0,0030 0,0030 0,0025 300,0 0,06 1 600,0 0,03 0 180,0 0,10 7 25 0,0050 0,0050 0,0041 187,5 0,10 10 375,0 0,05 0 112,5 0,16 25 32 0,0036 0,0036 0,0028 240,0 0,08 5 480,0 0,04 0 144,0 0,13 17 40 0,0030 0,0030 0,0025 300,0 0,06 2 600,0 0,03 0 180,0 0,10 11 50 0,0013 0,0013 0,0018 375,0 0,05 0 750,0 0,02 0 225,0 0,08 7 63 0,0012 0,0012 0,0013 472,5 0,04 0 945,0 0,02 0 283,5 0,06 3 32 0,0036 0,0036 0,0028 240,0 0,08 8 480,0 0,04 0 144,0 0,13 27 40 0,0030 0,0030 0,0025 300,0 0,06 3 600,0 0,03 0 180,0 0,10 18 50 0,0013 0,0013 0,0018 375,0 0,05 0 750,0 0,02 0 225,0 0,08 11 63 0,0012 0,0012 0,0013 472,5 0,04 0 945,0 0,02 0 283,5 0,06 5 Installation voltage: 24 V DC Impedance before the overcurrent protective device Zv = 50 m (assumption). For conductor temperature (80 C/176F) in the case of a short circuit) and for non-detectable impedances, a factor 2/3 is accounted for (DIN VDE 0100-610). 13 Selection criteria for rated current of MCBs Maximum operating current Minimum rated current Protection against overload The operating current (In) must not exceed the rated value of the component (contact, switch, RCD...) or the permissible current loading (IZ) of the cable or the line. DIN VDE 0100 - 520, Bbl.2/Nov. 2002 EN 60204-1/Nov. 1998 Protection of electrical components e.g. contact assemblies, position switches... Overcurrent protection of components is provided in the best possible manner if the non-delayed release trips within milliseconds if an overcurrent occurs. To do so, the fault loop resistance (Zs) and the upper trip value (Ia) of the non-delayed release need to be coordinated. Zs = 2 x Uo 3 Ia it follows that: Ia max 2 x Uo 3 Zs DIN VDE 0100 - 610/Apr. 04 Maximum operating current (IB) The main influences on the breaker are as follows: Influence of ambient temperature The delayed release (thermal bimetal), e.g.: Z/K-type characteristics is calibrated at an ambient temperature of 20 C/ 68 F. Deviating ambient temperature values will modify the tripping by ca. 6 % per 10 K. An ambient temperature in the cabinet of 40 C/104F will cause the device to trip 12 % earlier. Consequence: The operating current (IB) must be reduced by the factor 0.88. Mutual interference from the manufacturers' point of view In the case of mounting side by side, the power loss of the circuit-breaker has an impact on the thermostatic bimetals. In the case of high simultaneous capacity utilization, this means: The operating current (IB) must be reduced by a factor of 0.75. The max. operating current (IB) is thus calculated as follows: IB 0.88 x 0.75 2 x ln 3 Minimum operating current from the planner's perspective Example: The determined operating current (IB) = 4 A The minimum operating current (In) of the circuit-breaker is thus: In = 3 x lB ; In = 6 A 2 14 System pro M compact(R) Miniature circuit-breakers S 200 P Special features Application notes The optimum quick fastening technique, together with the System pro M compact PS... busbars, enable the quick and easy removal and insertion of System pro M compact devices without having to remove the busbar of the other equipment. 2CDC 003 432 F0003 Newly developed System pro M compact busbars. No time-consuming cutting to length. No extra end caps. Supplied ready to use in standard lengths. 2CDC 022 430 F0003 2CDC 003 431 F0003 S 200 SK 0047 B 99 If top-fed, cross-wiring between System pro M compact devices and MCBs of the S 280 series possible with compact pin-type busbars. Integrated positioning aid for self-adhesive write-on labels, numbered labels or labels with pictograms. A pad lock device prevents unauthorized switching to ON or OFF. Incoming supply up to 50 mm2 with external terminal. 2CDC 003 434 F0003 I SK 0045 B 99 S 260 Extension also possible with ready to use busbars. 15 System pro M compact(R) Miniature circuit-breakers S 200 P Special features Application notes Disconnector abilities according to EN 60 898-1, Rated surge withstand capability 6 kV (1.2/50) Test voltage 6.2 kV at NN; 5 kV at 2000 m. SK 0010 B01 Terminals with protection degree IPXXB. Optionally with new add on auxiliary switch (1 NO or 1 NC), ON = leading, OFF= lagging 50 % width saved. Cross-wiring with standard compact busbars possible and contact bridges HKB for cross-wiring of auxiliary contacts for series or parallel connections. 2-fold terminal connection top and bottom, supply optionally from top or bottom. A 16 2CDC 023 433 F0003 B System pro M compact(R) Miniature circuit-breakers S 200 P with integrated auxiliary contact Flexible and cost-efficient modernisation Auxiliary switch for System pro M compact(R) In the past years, the miniature circuit-breakers of the System pro M compact(R) type with integrated auxiliary switch - fitted ex works -have proven the test of time in the field of railway applications, switchgear and controlgear, telecommunications and mechanical engineering. SK 107 B01 Now, also auxiliary switches S2C-H10 (1 NO) and S2C-H01 (1 NC) can be retrofitted, too. They can be mounted individually and installed without having to modify the busbar. The simultaneous supply of the circuit-breaker is in no way affected. Compared to the previous lateral fixing method, the new technique offers the following advantages: Integrated auxiliary switch can be retrofitted from below Retrofitting without modification of the busbar 50 % space saved through installation from below Use of standard busbars with 17.5 mm grid possible Time- and cost-saving wiring with HKB contact bridges for group signal Time- and cost-saving wiring through 1-pole busbar, e.g. PS 1/57/6 for individual signalling with PS 1/57/6 for individual signal 2CDC 003 446 F0003 2CDC 003 038 F0005 The Signal Leading when switched on. Lagging when switched off, thus no fault signal. with HKB for group signal 17 System pro M compact(R) Miniature circuit-breakers S 200 P series S 200 P-B Selection table B Rated current In A Ordering details Type No. Order code bbn 40 16779 EAN 6 10 13 S 201 P-B 6 S 201 P-B 10 S 201 P-B 13 2CDS 281 001 R0065 2CDS 281 001 R0105 2CDS 281 001 R0135 589574 589581 589598 62 62 62 16 20 25 S 201 P-B 16 S 201 P-B 20 S 201 P-B 25 2CDS 281 001 R0165 2CDS 281 001 R0205 2CDS 281 001 R0255 589260 589604 589611 62 62 62 32 UBmax 440 V~ 40 72 V ... - 50 S 201 P-B 32 S 201 P-B 40 S 201 P-B 50 2CDS 281 001 R0325 2CDS 281 001 R0405 2CDS 281 001 R0505 589628 589635 589659 62 62 62 63 S 201 P-B 63 2CDS 281 001 R0635 589666 62 6 10 13 S 202 P-B 6 S 202 P-B 10 S 202 P-B 13 2CDS 282 001 R0065 2CDS 282 001 R0105 2CDS 282 001 R0135 58967 3 58968 0 58969 7 62 62 62 16 20 25 S 202 P-B 16 S 202 P-B 20 S 202 P-B 25 2CDS 282 001 R0165 2CDS 282 001 R0205 2CDS 282 001 R0255 58970 3 58971 0 58972 7 62 62 62 32 40 50 S 202 P-B 32 S 202 P-B 40 S 202 P-B 50 2CDS 282 001 R0325 2CDS 282 001 R0405 2CDS 282 001 R0505 58973 4 58974 1 58975 8 62 62 62 63 S 202 P-B 63 2CDS 282 001 R0635 58976 5 62 6 10 13 S 203 P-B 6 S 203 P-B 10 S 203 P-B 13 2CDS 283 001 R0065 2CDS 283 001 R0105 2CDS 283 001 R0135 58977 2 58978 9 58979 6 62 62 62 16 20 25 S 203 P-B 16 S 203 P-B 20 S 203 P-B 25 2CDS 283 001 R0165 2CDS 283 001 R0205 2CDS 283 001 R0255 58980 2 58981 9 58982 6 62 62 62 32 40 50 S 203 P-B 32 S 203 P-B 40 S 203 P-B 50 2CDS 283 001 R0325 2CDS 283 001 R0405 2CDS 283 001 R0505 58983 3 58984 0 58985 7 62 62 62 63 S 203 P-B 63 2CDS 283 001 R0635 58986 4 62 6 10 13 S 204 P-B 6 S 204 P-B 10 S 204 P-B 13 2CDS 284 001 R0065 2CDS 284 001 R0105 2CDS 284 001 R0135 58987 1 58988 8 58989 5 62 62 62 16 20 25 S 204 P-B 16 S 204 P-B 20 S 204 P-B 25 2CDS 284 001 R0165 2CDS 284 001 R0205 2CDS 284 001 R0255 58990 1 58991 8 58992 5 62 62 62 32 40 50 S 204 P-B 32 S 204 P-B 40 S 204 P-B 50 2CDS 284 001 R0325 2CDS 284 001 R0405 2CDS 284 001 R0505 58993 2 58994 9 58995 6 62 62 62 63 S 204 P-B 63 2CDS 284 001 R0635 58996 3 62 No. of poles 1 acc. to IEC 60898 for line protection 2CDC 021 100 F0004 25 000 2 UBmax 440 V~ 125 V ... - 2CDC 021 101 F0004 3 U Bmax 440 V~ 2CDC 021 102 F0004 4 UBmax 440 V~ 125 V ... - 2CDC 021 103 F0004 ... with 2 poles connected in series UBmax 125 V -- max. switching capacity of series (see Technical Data) 18 Price Price Weight Pack. 1 piece group 1 piece unit piece kg 0.14 10 0.28 5 0.42 1 0.56 1 System pro M compact(R) Miniature circuit-breakers S 200 P series S 200 P-K K-type characteristics, well proven for more than 70 years. K K ( = power) characteristic according to IEC 60947-2 (power circuit-breaker) 1. Functional peak currents up to 14 x In do not provoke nuisance tripping. 2. Due to its sensitive thermo-bimetal release, the K-type tripping characteristic offers reliable protection to sensitive components in the overcurrent range. Furthermore, it offers excellent protection of cables and lines. acc. to IEC 60947-2 for power circuits, motors, transformers, lamps and for line protection 25 000 Selection table Type No. Order code bbn 40 16779 EAN 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 25 UBmax 440 V~ 32 72 V ... - 40 50 63 1 S 201 P-K 0.2 S 201 P-K 0.3 S 201 P-K 0.5 S 201 P-K 0.75 S 201 P-K 1 S 201 P-K 1.6 S 201 P-K 2 S 201 P-K 3 S 201 P-K 4 S 201 P-K 6 S 201 P-K 8 S 201 P-K 10 S 201 P-K 13 S 201 P-K 16 S 201 P-K 20 S 201 P-K 25 S 201 P-K 32 S 201 P-K 40 S 201 P-K 50 S 201 P-K 63 2CDS 281 001 R0087 2CDS 281 001 R0117 2CDS 281 001 R0157 2CDS 281 001 R0187 2CDS 281 001 R0217 2CDS 281 001 R0257 2CDS 281 001 R0277 2CDS 281 001 R0317 2CDS 281 001 R0337 2CDS 281 001 R0377 2CDS 281 001 R0407 2CDS 281 001 R0427 2CDS 281 001 R0447 2CDS 281 001 R0467 2CDS 281 001 R0487 2CDS 281 001 R0517 2CDS 281 001 R0537 2CDS 281 001 R0557 2CDS 281 001 R0577 2CDS 281 001 R0607 59221 5 59222 2 59223 9 59224 6 59225 3 59226 0 59227 7 59228 4 59229 1 59230 7 59231 4 59232 1 59233 8 59234 5 59235 2 59236 9 59237 6 59238 3 59239 0 59240 6 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 0.14 10 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 UBmax 440 V~ 25 125 V ... - 32 40 50 63 S 202 P-K 0.2 S 202 P-K 0.3 S 202 P-K 0.5 S 202 P-K 0.75 S 202 P-K 1 S 202 P-K 1,6 S 202 P-K 2 S 202 P-K 3 S 202 P-K 4 S 202 P-K 6 S 202 P-K 8 S 202 P-K 10 S 202 P-K 13 S 202 P-K 16 S 202 P-K 20 S 202 P-K 25 S 202 P-K 32 S 202 P-K 40 S 202 P-K 50 S 202 P-K 63 2CDS 282 001 R0087 2CDS 282 001 R0117 2CDS 282 001 R0157 2CDS 282 001 R0187 2CDS 282 001 R0217 2CDS 282 001 R0257 2CDS 282 001 R0277 2CDS 282 001 R0317 2CDS 282 001 R0337 2CDS 282 001 R0377 2CDS 282 001 R0407 2CDS 282 001 R0427 2CDS 282 001 R0447 2CDS 282 001 R0467 2CDS 282 001 R0487 2CDS 282 001 R0517 2CDS 282 001 R0537 2CDS 282 001 R0557 2CDS 282 001 R0577 2CDS 282 001 R0607 59241 3 59242 0 59243 7 59244 4 59245 1 59246 8 59247 5 59248 2 59249 9 59250 5 59251 2 59252 9 59253 6 59254 3 59255 0 59256 7 59257 4 59258 1 59259 8 59260 4 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 0.28 5 3 S 203 P-K 0.2 S 203 P-K 0.3 S 203 P-K 0.5 S 203 P-K 0.75 S 203 P-K 1 S 203 P-K 1,6 S 203 P-K 2 S 203 P-K 3 S 203 P-K 4 S 203 P-K 6 S 203 P-K 8 S 203 P-K 10 S 203 P-K 13 S 203 P-K 16 S 203 P-K 20 S 203 P-K 25 S 203 P-K 32 S 203 P-K 40 S 203 P-K 50 S 203 P-K 63 2CDS 283 001 R0087 2CDS 283 001 R0117 2CDS 283 001 R0157 2CDS 283 001 R0187 2CDS 283 001 R0217 2CDS 283 001 R0257 2CDS 283 001 R0277 2CDS 283 001 R0317 2CDS 283 001 R0337 2CDS 283 001 R0377 2CDS 283 001 R0407 2CDS 283 001 R0427 2CDS 283 001 R0447 2CDS 283 001 R0467 2CDS 283 001 R0487 2CDS 283 001 R0517 2CDS 283 001 R0537 2CDS 283 001 R0557 2CDS 283 001 R0577 2CDS 283 001 R0607 59261 1 59262 8 59263 5 59264 2 59265 9 59266 6 59267 3 59268 0 59269 7 59270 3 59271 0 59272 7 59273 4 59274 1 59275 8 59276 5 59277 2 59278 9 59279 6 59280 2 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 0.42 1 Rated current In A 2 2CDC 021 103 F0004 2CDC 021 102 F0004 2CDC 021 101 F0004 2CDC 021 100 F0004 No. of poles U Bmax 440 V~ 0.2 0.3 0.5 0.75 1 1,6 2 3 4 6 8 10 13 16 20 25 32 40 50 63 Ordering details Price Price Weight Pack. 1 piece group 1 piece unit piece kg ... with 2 poles connected in series UBmax 125 V -- max. switching capacity of the series (see Technical Data) 19 System pro M compact(R) Miniature circuit-breakers S 200 P series S 200 P-K Selection table K No. of poles 2CDC 021 103 F0004 2CDC 021 102 F0004 2CDC 021 101 F0004 2CDC 021 100 F0004 25 000 20 0.2 0.3 0.5 0.75 1 1.6 2 3 4 6 8 10 13 16 20 25 UBmax 440 V~ 32 72 V ... - 40 50 63 4 acc. to IEC 60947-2 for power circuits, motors, transformers, lamps and for line protection Rated current In A Ordering details Type No. Order code bbn 40 16779 EAN S 204 P-K 0.2 S 204 P-K 0.3 S 204 P-K 0.5 S 204 P-K 0.75 S 204 P-K 1 S 204 P-K 1.6 S 204 P-K 2 S 204 P-K 3 S 204 P-K 4 S 204 P-K 6 S 204 P-K 8 S 204 P-K 10 S 204 P-K 13 S 204 P-K 16 S 204 P-K 20 S 204 P-K 25 S 204 P-K 32 S 204 P-K 40 S 204 P-K 50 S 204 P-K 63 2CDS 284 001 R0087 2CDS 284 001 R0117 2CDS 284 001 R0157 2CDS 284 001 R0187 2CDS 284 001 R0217 2CDS 284 001 R0257 2CDS 284 001 R0277 2CDS 284 001 R0317 2CDS 284 001 R0337 2CDS 284 001 R0377 2CDS 284 001 R0407 2CDS 284 001 R0427 2CDS 284 001 R0447 2CDS 284 001 R0467 2CDS 284 001 R0487 2CDS 284 001 R0517 2CDS 284 001 R0537 2CDS 284 001 R0557 2CDS 284 001 R0577 2CDS 284 001 R0607 59281 9 59282 6 59283 3 59284 0 59285 7 59286 4 59287 1 59288 8 59289 5 59290 1 59291 8 59292 5 59293 2 59294 9 59295 6 59296 3 59297 0 59298 7 59299 4 59300 7 max. switching capacity of the series (see Technical Data) Price Price Weight Pack. 1 piece group 1 piece unit piece kg 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 62 0.56 1 System pro M compact(R) Miniature circuit-breakers S 200 P series S 200 P-Z Selection table Z Type No. Order code bbn 40 16779 EAN 0.5 1 1.6 S 201 P-Z 0.5 S 201 P-Z 1 S 201 P-Z 1.6 2CDS 281 001 R0158 2CDS 281 001 R0218 2CDS 281 001 R0258 59341 0 59342 7 59343 4 62 62 62 2 3 4 S 201 P-Z 2 S 201 P-Z 3 S 201 P-Z 4 2CDS 281 001 R0278 2CDS 281 001 R0318 2CDS 281 001 R0338 59344 1 59345 8 59346 5 62 62 62 6 8 10 S 201 P-Z 6 S 201 P-Z 8 S 201 P-Z 10 2CDS 281 001 R0378 2CDS 281 001 R0408 2CDS 281 001 R0428 59347 2 59348 9 59349 6 62 62 62 16 20 25 S 201 P-Z 16 S 201 P-Z 20 S 201 P-Z 25 2CDS 281 001 R0468 2CDS 281 001 R0488 2CDS 281 001 R0518 59350 2 59351 9 59352 6 62 62 62 32 UBmax 440 V~ 40 72 V ... - 50 63 S 201 P-Z 32 S 201 P-Z 40 S 201 P-Z 50 2CDS 281 001 R0538 2CDS 281 001 R0558 2CDS 281 001 R0578 59353 3 59354 0 59355 7 62 62 62 No. of poles acc. to IEC 60947-2 for the protection of control circuits, voltage transformer circuits, semiconductor protection in the case of selective assignment and lines 1 2CDC 021 102 F0004 2CDC 021 101 F0004 2CDC 021 100 F0004 25 000 2 UBmax 440 V~ 125 V ... - 3 U Bmax 440 V~ 2CDC 021 103 F0004 4 UBmax 440 V~ 125 V ... - Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit piece kg S 201 P-Z 63 2CDS 281 001 R0608 59356 4 62 0.5 1 1.6 S 202 P-Z 0.5 S 202 P-Z 1 S 202 P-Z 1.6 2CDS 282 001 R0158 2CDS 282 001 R0218 2CDS 282 001 R0258 59357 1 59358 8 59359 5 62 62 62 2 3 4 S 202 P-Z 2 S 202 P-Z 3 S 202 P-Z 4 2CDS 282 001 R0278 2CDS 282 001 R0318 2CDS 282 001 R0338 59360 1 59361 8 59362 5 62 62 62 6 8 10 S 202 P-Z 6 S 202 P-Z 8 S 202 P-Z 10 2CDS 282 001 R0378 2CDS 282 001 R0408 2CDS 282 001 R0428 59363 2 59364 9 59365 6 62 62 62 16 20 25 S 202 P-Z 16 S 202 P-Z 20 S 202 P-Z 25 2CDS 282 001 R0468 2CDS 282 001 R0488 2CDS 282 001 R0518 59366 3 59367 0 59368 7 62 62 62 32 40 50 S 202 P-Z 32 S 202 P-Z 40 S 202 P-Z 50 2CDS 282 001 R0538 2CDS 282 001 R0558 2CDS 282 001 R0578 59369 4 59370 0 59371 7 62 62 62 63 S 202 P-Z 63 2CDS 282 001 R0608 59372 4 62 0.5 1 1.6 S 203 P-Z 0.5 S 203 P-Z 1 S 203 P-Z 1.6 2CDS 283 001 R0158 2CDS 283 001 R0218 2CDS 283 001 R0258 59373 1 59374 8 59375 5 62 62 62 2 3 4 S 203 P-Z 2 S 203 P-Z 3 S 203 P-Z 4 2CDS 283 001 R0278 2CDS 283 001 R0318 2CDS 283 001 R0338 59376 2 59377 9 59378 6 62 62 62 6 8 10 S 203 P-Z 6 S 203 P-Z 8 S 203 P-Z 10 2CDS 283 001 R0378 2CDS 283 001 R0408 2CDS 283 001 R0428 59379 3 59380 9 59381 6 62 62 62 16 20 25 S 203 P-Z 16 S 203 P-Z 20 S 203 P-Z 25 2CDS 283 001 R0468 2CDS 283 001 R0488 2CDS 283 001 R0518 59382 3 59383 0 59384 7 62 62 62 32 40 50 S 203 P-Z 32 S 203 P-Z 40 S 203 P-Z 50 2CDS 283 001 R0538 2CDS 283 001 R0558 2CDS 283 001 R0578 59385 4 59386 1 59387 8 62 62 62 63 S 203 P-Z 63 2CDS 283 001 R0608 59388 5 62 0.5 1 1.6 S 204 P-Z 0.5 S 204 P-Z 1 S 204 P-Z 1.6 2CDS 284 001 R0158 2CDS 284 001 R0218 2CDS 284 001 R0258 59389 2 59390 8 59391 5 62 62 62 2 3 4 S 204 P-Z 2 S 204 P-Z 3 S 204 P-Z 4 2CDS 284 001 R0278 2CDS 284 001 R0318 2CDS 284 001 R0338 59392 2 59393 9 59394 6 62 62 62 6 8 10 S 204 P-Z 6 S 204 P-Z 8 S 204 P-Z 10 2CDS 284 001 R0378 2CDS 284 001 R0408 2CDS 284 001 R0428 59395 3 59396 0 59397 7 62 62 62 16 20 25 S 204 P-Z 16 S 204 P-Z 20 S 204 P-Z 25 2CDS 284 001 R0468 2CDS 284 001 R0488 2CDS 284 001 R0518 59398 4 59399 1 59400 4 62 62 62 32 40 50 S 204 P-Z 32 S 204 P-Z 40 S 204 P-Z 50 2CDS 284 001 R0538 2CDS 284 001 R0558 2CDS 284 001 R0578 59401 1 59402 8 59403 5 62 62 62 63 S 204 P-Z 63 2CDS 284 001 R0608 59404 2 62 0.14 10 0.28 5 0.42 1 0.56 1 ... with 2 poles connected in series UBmax 125 V -- max. switching capacity of the series (see Technical Data) 21 System pro M compact(R) Additional devices Miniature circuit-breakers S 200/S 200 M/S 200 P series Selection table Description Ordering details SK 209 B 02 Type No. Order code bbn 40 16779 EAN 2CDS 200 909 R0001 57099 2 5 2CDS 200 909 R0002 57100 5 5 2CSS 200 911 R0001 2CSS 200 911 R0002 2CSS 200 911 R0007 2CSS 200 911 R0003 2CSS 200 911 R0008 2CSS 200 911 R0004 2CSS 200 911 R0009 2CSS 200 911 R0005 2CSS 200 911 R0010 2CSS 200 911 R0006 83070 2* 83080 1* 83980 4* 83090 0* 89650 0* 83100 6* 89660 9* 83110 5* 89670 8* 83120 4* 5 5 5 5 5 5 5 5 5 5 Price Price Weight Pack. 1 piece group 1 piece unit piece kg Shunt release S 2C-A1 AC/DC 12 ... 60 V AC 110 ... 415 V and S 2C-A2 DC 110 ... 250 V 0.15 1 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09 1 S 2C-A Undervoltage release 12 V DC 24 V AC 24 V DC 48 V AC 48 V DC 110 V AC 110 V DC 230 V AC 230 V DC 400 V AC S 2C-UA 12 DC S 2C-UA 24 AC S 2C-UA 24 DC S 2C-UA 48 AC S 2C-UA 48 DC S 2C-UA 110 AC S 2C-UA 110 DC S 2C-UA 230 AC S 2C-UA 230 DC S 2C-UA 400 AC 2CDC 022 424 F0004 * bbn-No. 80 12542 Integrated auxiliary switch retrofittable from below to circuit-breaker S 200/S 200 M/S 200 P (with 25 mm2 terminal only) 1 NC 1 NO S 2C-H01 S 2C-H10 2CDS 200 970 R0001 2CDS 200 970 R0002 64551 5 64552 2 5 5 1 1 2CDS 200 970 R0011 2CDS 200 970 R0012 64677 2 64681 9 5 5 1 set 1 set Packs of 15 piece per set S 2C-H01 S 2C-H10 22 1 NC 1 NO S 2C-H01 15x S 2C-H10 15x Busbar systems Overview The busbar systems incorporate a complete range for safe and efficient installations of built-in devices, e.g. circuit-breakers, (power / miniature circuit-breakers), RCCB, RCBO and modular devices (MDRC). The following is important to note when choosing the right busbars: Type of terminal (e.g. combined box terminals, screw terminals)1) Number of poles of the devices {e.g. 1-, 2-, 3-, 4-pole, 1-pole + neutral conductor (NA), 3-pole + neutral conductor (NA)} Type of device {circuit-breaker (MCB), RCCB, RCBO and modular DIN rail components (MDRC)} Mixed components (e.g. installation of MCBs and MDRCs on one rail) Use of additional devices (e.g. MCB with auxiliary switch) Busbar cross section (current rating) Number of modules (various lengths of busbars supplied ex works) 1) Screw terminals are no longer included in the current ABB production range. Technical Data Standards Rail material : Insulation profile material : Busbar capacity: Nominal operating voltage Uc: Nominal current In: Short-circuitrupturing capacity Uimp: DIN EN 60439 Part 1 (VDE 0660 Part 500): 2000-08 SF-Cu F 24 plastics, Cycoloy 3600 temperature-resistant 90 C/194 F flame retardant, self-extinguishing dioxine and halogene-free 6 mm2 - 36 mm2 400 V AC 63 A (10 mm2) 80 A (16 mm2) Impulse test voltage: (1,2/50) Cond. nominal short-circuit rupturing current Icc: Climatic resistance: Insulation coordination: - overvoltage category: - pollution degree: 6,2 kV 25 kA constant climate: 23/83; 40/92; 55/20 acc. to DIN 50015 Damp heat, 28 operations (^= IEC 68 Part 2 - 30 acc. to VDE 0110 Part 1 April 1997 (IEC 664) III 2 4 kV All busbars PSB, PS 1/... and KS are UL/CSA-approved. Rails according to UL 1077 Loadability depending on point of supply and required capacity busbar (PS/PSB type) comb busbar / oblong hole (KS type) End feeding Capacity /mm2 10 12 20 24 36 10 16 Maximum busbar current lS/phase A 63 65 90 100 130* 63 80 100 110 150* 170* 220* 100 130* Non-end feeding (center or elsewhere on the rail) Maximum current in branch IE/phase 1) A Maximum supply current IE/phase A Depends on connection capacity * In the case of direct supply via device terminals, take into account that - irrespective of the current carrying capacity (IS) of the busbar - the following current values are not exceeded: The series S200 and S200 M max. 110 A; for S 200 P, 140 A max. SK 0063 Z 91 Non-end feeding (center or elsewhere on the rail) SK 0062 Z 91 End feeding In the case of center-fed installations (see right picture) ensure that the sum of outgoing currents a1...an per rail branch does not exceed the maximum busbar current IS/phase. 23 System pro M compact(R) Busbars and accessories for S 200 P capacity mm2 No. of phases Ordering details pins Type No. Cu bbn 40 16779 EAN CuNo. 2CDL 210 001 R1002 2CDL 210 001 R1003 2CDL 210 001 R1006 2CDL 210 001 R1009 2CDL 210 001 R1012 46300 3 51465 1 46310 2 46320 1 46330 0 0.010 0.030 0.030 0.040 0.050 15 15 15 15 15 0.008 180 0.025 120 0.025 60 0.039 30 0.052 30 2CDL 231 001 R1006 2CDL 231 001 R1009 2CDL 231 001 R1012 2CDL 231 002 R1012 463409 463508 463607 463706 0.040 0.070 0.100 0.100 15 15 15 15 0.042 0.069 0.096 0.094 60 30 30 50 0.260 0.410 15 15 0.260 0.410 20 20 Order code Price Price Weight Pack. 1 piece group 1 piece unit piece kg Pre-cut busbars, cannot be cut to length Single-phase busbars, spacing 17.6 mm PS 1/2 - PS 1/12 SK 0027 B99 10 10 10 10 10 2 3 6 9 12 1 1 1 1 1 PS 1/2 PS 1/3 PS 1/6 PS 1/9 PS 1/12 Three-phase busbars, spacing 17.6 mm 10 10 10 10 PS 3/6 - PS 3/12 (2CDL 231 ...) SK 0028 B99 6 9 12 12 3 3 3 3 PS 3/6 PS 3/9 PS 3/12 PS 3/12 FI Busbars, to be cut to length (wiring example see page 25) Single-phase busbars, spacing 17.6 mm; use PS-END 0 end caps 10 16 60 60 1 1 PS 1/60 PS 1/60/16 2CDL 210 001 R1060 2CDL 210 001 R1660 51466 8 51665 5 Single-phase busbars, wiring of neutral, blue insulation; use END 1.1 end caps 10 16 10 10 16 16 28 28 57 57 57 57 1 1 1 1 1 1 PS 1/28 N PS 1/28/16 N PS 1/57 NA2 PS 1/57 N PS 1/57/16 NA2 PS 1/57/16 N 2CDL 210 001 R1028 2CDL 210 001 R1628 2CDL 210 011 R1057 2CDL 210 001 R1057 2CDL 210 011 R1657 2CDL 210 001 R1657 62954 6 62956 0 57972 8 62953 9 57973 5 62955 3 0.240 0.320 0.240 0.240 0.320 0.320 15 15 15 15 15 15 0.144 0.203 0.144 0.144 0.203 0.203 50 50 50 50 50 50 2CDL 210 005 R0657 58530 9 0.140 15 0.075 50 15 0.001 1000 Auxiliary contact busbar 6 57 1 PS 1/57/6 + HKB Auxiliary contact bridge for integrated auxiliary contact, installation from below HKB 1/2 mod. GH V036 0504 R0100 52313 4 2CDC 062 415 F0004 Two-phase busbars, spacing 17.6 mm; use PS-END end caps Removal of pin PS...A 10 10 10 16 16 2 2 2 2 2 PS 2/121 PS 2/12 A1 2 PS 2/58 PS 2/58/16 PS 2/58/16 A 2CDL 220 001 R1012 2CDL 220 010 R1012 2CDL 220 001 R1058 2CDL 220 001 R1658 2CDL 220 010 R1658 55652 1 58461 6 55655 2 55656 9 58474 6 0.070 0.070 0.320 0.545 0.545 15 15 15 15 15 0.075 0.075 0.360 0.488 0.488 50 50 10 10 10 57611 6 58464 7 56280 5 51469 9 56375 8 51470 5 56376 5 0.085 0.085 0.160 0.505 0.505 0.760 0.760 15 15 15 15 15 15 15 0.088 0.088 0.120 0.470 0.470 0.647 0.647 50 50 50 10 10 10 10 Three-phase busbars, spacing 17.6 mm; use PS-END end caps 10 10 16 10 10 16 16 1 24 12 12 58 58 58 12 12 12 60 60 60 60 incl. end caps 3 3 3 3 3 3 3 PS 3/121 PS 3/12 A1 2 PS 3/12/161 PS 3/60 PS 3/60 A2 PS 3/60/16 PS 3/60/16 A2 2CDL 230 001 R1012 2CDL 230 010 R1012 2CDL 230 001 R1612 2CDL 230 001 R1060 2CDL 230 010 R1060 2CDL 230 001 R1660 2CDL 230 010 R1660 2 knock-out pins System pro M compact(R) 2CDC 061 433 F0004 Busbars and accessories for S 200 P PS 4/12 Capacity mm2 No. of Phases Ordering details pins Type No. Order code Cu bbn 40 16779 EAN CuNo. 55666 8 58467 8 55667 5 55668 2 55674 3 58468 5 0.120 0.120 0.241 0.803 1.205 1.205 15 15 15 15 15 15 0.112 0.112 0.155 0.635 0.890 0.890 30 30 30 10 10 10 0,140 0,803 1,205 1,205 15 15 15 15 0.103 0.590 0.768 0.768 30 10 10 10 Price Price Weight Pack. 1 piece group 1 piece unit piece kg 4-phase busbars, spacing 17.6 mm; use PS-END 1 end caps 10 10 16 10 16 16 12 12 12 60 60 60 PS 4/121 PS 4/12 A1/2 PS 4/12/161 PS 4/60 PS 4/60/16 PS 4/60/16 A2 4 4 4 4 4 4 2CDL 240 001 R1012 2CDL 240 010 R1012 2CDL 240 001 R1612 2CDL 240 001 R1060 2CDL 240 001 R1660 2CDL 240 010 R1660 4-phase busbars, wiring of 1 + N and RCBO use PS-END 1 end caps 10 10 16 16 1 12 58 58 58 PS 4/12 NA1/2 PS 4/58 N PS 4/58/16 N PS 4/58/16 NA2 4 4 4 4 2 incl. end caps Capacity mm2 2CDL 240 013 R1012 2CDL 240 001 R1058 2CDL 240 001 R1658 2CDL 240 013 R1658 58470 8 55670 5 55673 6 58471 5 knockout pins Module Phases Ordering details Type No. Order code bbn 40 16779 EAN END 1.1 PS-END 0 PS-END PS-END 1 PS-END SP PS-END 1 SP 2CDL 200 011 R0011 2CDL 200 001 R0003 2CDL 200 001 R0001 2CDL 200 001 R0002 2CDL 200 110 R0001 2CDL 200 110 R0002 63891 3 64652 9 51472 9 57011 4 64650 5 64651 2 Price Price Weight Pack. 1 piece group 1 piece unit piece kg End caps RV 3 SK 0120 Z01 15 15 15 15 15 15 0.001 0.001 0.001 0.001 0.001 0.001 50 50 50 50 50 50 51238 1 51224 4 15 15 0.080 25 0.114 25 42000 6 15 0.003 10 Rail connector For the wiring of components rails in the distribution board, rail-to-rail clearance 125 mm. In the case of the 4-pole connector, the color of the N conductor is blue. 10 10 RV 4 SK 0121 Z01 3-pole 4-pole RV 3 RV 4 Shock-protection caps for PS... Busbars 5 parts SZ-BSK SZ-BSK GH V036 0504 R0023 GH V036 0504 R0024 2CDL 200 001 R0011 SK 0100 B99 25 System pro M compact(R) Busbar systems for S 200 P 2CDC 062 021 F0004 PS 3/... (2CDL 231 ...) PS 4/12 PS 4/12/16 PS 4/60 PS 4/60/16 PS 4/12 A PS 4/60/16 A PS 4/60/16 SP SK 0065 Z02 2CDC 062 527 F0004 PS 4/12 NA PS 4/58 N PS 4/58/16 N PS 4/58/16 NA PS 4/58/16 N SP Example for overlapping PS 2/12 PS 2/58 PS 2/58/16 PS 2/12 A PS 2/58/16 A PS 2/58 SP PS 2/58/16 SP 26 SK 0059 Z 02 SK 0250 Z 02 2CDC 062 387 F0003 PS 1/57/6 H (integrated auxiliary contact) PS 3/12 PS 3/12 A PS 3/12/16 PS 3/60 PS 3/60/16 PS 3/60 A PS 3/60/16 A PS 3/60 SP PS 3/60/16 SP SK 0063 Z 02 2CDC 062 166 F0003 PS 1/... PS 1/.../16 SK 0060 Z 02 Wiring example System pro M compact(R) Busbars and accessories Labels for S 200 P Ordering details Description Type No. bbn 40 16779 EAN Order code Price Price Weight Pack. 1 piece group 1 piece unit piece kg Labeling system Self-adhesive identification labels are available for all devices of the System pro M compact range. An integrated positioning device ensures the exact arrangement of labels. Selection table identification label of BS 1/40 SK 0047 B99 40 labels each, marked or blank. Blank label mats can be labeled by hand with an indelible, waterproof pen or with computerised labeling systems (plotters). Identification labels blank BS GH S200 1946 R0001 47810 6 5 0.004 30 Identification labels with pictograms BS Pikto GH S200 1946 R0002 47820 5 5 0.004 30 Identification labels numbered 4 x 1 - 10 BS 1/10 GH S200 1946 R0003 47830 4 5 0.004 30 Identification labels numbered 2 x 1 - 20 BS 1/20 GH S200 1946 R0004 47840 3 5 0.004 30 Identification labels numbered 1 - 40 BS 1/40 GH S200 1946 R0005 47850 2 5 0.004 30 Identification labels numbered 41 - 80 BS 41/80 GH S200 1946 R0006 58591 0 5 0.004 30 Identification labels numbered 81 - 120 BS 81/120 GH S200 1946 R0007 58592 7 5 0.004 30 Identification labels numbered 121 - 160 BS 121/160 GH S200 1946 R0008 58593 4 5 0.004 30 SK 0101 Z99 SK 0102 Z99 SK 0105 Z99 SK 0104 Z99 SK 0103 Z99 ILS Identification System The ILS individual identification system for labels is a DIN A5 polyester film for ink jet and laser printers with high temperature resistance. (If laser printers are used, check first whether self-adhesive film with a thickness of 250 m is acceptable). Adhesive coating 3MTM9471 LE is UL recognized (File MH 11410). The individual labels are precut from one side. Download your word template from www.abb.de/stotz-kontakt. Can also be used as write-on labels (ink, ballpoint pen, pencil, marker). 1 sheet with 126 adhesive labels ILS (1 module: 6 x 17.2 mm) 2CDL 200 002 R0001 58922 2 15 0.011 1 1 sheet with 210 adhesive labels ILS-H (1/2 module: 6 x 8.5 mm) 2CDL 200 002 R0002 58923 9 15 0.011 1 27 System pro M compact(R) Miniature circuit-breakers S 200 P Technical Data Specifications: No. of poles: Tripping characteristics: Nominal current In: Nominal voltage Un: Max. operating voltage UBmax: Min. operating voltage UBmin : Energy limitation class: Rated switching capacity: Frequency: Insulation coordination: - Overvoltage category: - Pollution degree: - Surge withstand capability Uimp (1.2/50 s): - Impulse alternating voltage: Housing: Operating lever: Type/degree of protection DIN EN 60 529: Dimensions: Depth of device: Overall dimensions: Mounting position: Position indication: Fixing: Connection: Tightening torque: Mechanical service life: Service life at rated load In 32 A: In 32 A: Climatic resistance according to IEC 60 068: Storage temperature: Ambient temperature: Shock resistance: Vibration resistance acc. to DIN EN 60 068-2-6: Weight: DIN VDE 0641 Part 11, IEC 60898, EN 60898, IEC 60947-2 1, 2, 3, 4 B, K, Z B 6 ... 63 A, K 0,2 ... 63 A and Z 0,5 ... 63 A 1-pole 230 V multipole 400 V AC Un + 10 % DC 1-pole 72 V ... 2-pole 125 V ... 12 V , 12 V3 In 25 A 25 000 In 32 A 15 000 50 ...60 Hz acc. to DIN VDE 0110 Part 1 and 2 III 2 4 kV (test voltage 6.2 kV at NN; 5 kV on 2000 m) 2.5 kV (50/60 Hz, 1 min) insulation material rating I (CTI 600) acc. to DIN IEC 112/VDE 0303 Part 1, RAL 7035 insulation material rating II (400 CTI 600) black, sealable IPXXB acc. to DIN 43880, code size 1 68 mm see Dimension drawings optional operating lever: I ON/0 OFF for S 200 P additional window red/green snap-on onto mounting rail EN 60 715, 35 mm screw-fixing onto mounting rail 2 terminal supply top and bottom Suitable for connecting single, multi- and finely stranded conductors up to 25 mm2 (if also connected to rails) 2.8 Nm 20.000 operations 20.000 operations 10.000 operations constant climate 23/83, 40/93, 55/20 [C/RH] alternating climate25/95 - 40/93 [C/RH] Tmax + 70 C 158F, Tmin - 50 C / -58F Tmax + 55 C/131F, Tmin - 25 C/-13F 30 g, at least two impacts, shock duration 13 ms 5 g, 20 frequency cycles 5 ... 150 ... 5 Hz at 0.8 In see Selection tables Technical Data of the integrated auxiliary contact Contact: 1NO (1 make contact), 1 NC (1 normally closed contact) lead making contact, late closing Contact load: AC 14 2A/230 V DC 12 identical DC 13/DC 13 1 A/50 V, 2 A/30 V Min. operating voltage: 12 V AC/DC at 0.1 VA Short-circuit withstand capacity: 230 V 1000 A, short-circuit protection with S 201-K2 or Z2 Electrical service life: 4,000 operations Safe disconnection of auxiliary circuit and main circuit acc. to VDE 0106 Part 101 Connection capacity: 0.75 to 2.5 mm2 (finely stranded conductors to be fitted with connector sleeve) Tighening torque: max. 0.5 Nm 28 System pro M compact(R) Miniature circuit-breakers S 200 P Operating sequence: B and C acc. to DIN VDE 0641, DIN VDE 0660 Part 101 ICS K and Z acc. to IEC 947 Rated switching capacity Series Tripping characteristic Nominal current Alternating current 1-phase 133 V 230 V kA/cos A S 200 P-B S 200 P-C S 200 P-K, Z 6 10, 13 16 ... 25 32 ... 40 50 ... 63 0,5 ... 2 3, 4 6, 8 10, 13 16 ... 25 32 ... 40 50 ... 63 0.2/0.5 ... 2 3 4 6 8 10 ... 20 25 32 ... 63 2/3-phase 230 V 133/230 V kA/cos kA/cos 400 V 230/400 V kA/cos Direct current 1pole 60 V ... kA/T ms 10/4.0 25/0.25 25/0.25 25/0.25 25/0.25 15/0.25 15/0.25 15/0.25 15/0.25 15/4.0 10/4.0 Back-up protection Max. Select. Main Fuse Circuit-Breaker S 700 gG/gL 63 A 80 A 100 A 125 A 160 A unlimited 25/0.25 25/0.25 25/0.25 10/4.0 25/0.25 15/4.0 15/0.25 15/0.25 15/0.25 15/0.25 10/4.0 35 A 63 A 80 A 100 A 125 A 160 A unlimited 10/4.0 25/0.25 25/0.25 15/0.25 25/0.25 15/0.25 25/0.25 15/0.25 15/4.0 15/4.0 10/4.0 15/0.25 25 A 35 A 63 A 80 A 100 A 125 A 160 A 100 A 100 A 100 A 100 A 100 A not required 100 A 100 A 100 A 100 A 100 A 100 A not required - - 100 A 100 A 100 A 100 A 100 A In symmetrically earthed direct current circuits, 2-pole devices (two poles connected in series) can be used up to 125 V DC. Any connection is possible, polarity does not need to be taken into account. Back-up protection is necessary only if the solid short-circuit current to be expected at the place of installation may exceed the switching capacity indicated Note: in the case of back-up fuses up to 315 A, we recommend the use of the high-performance cicruit-breaker S 610 with a switching capacity of 50kA instead of the local circuit pro M compact MCB. Internal resistance and power loss of miniature circuit-breakers Internal resistance per pole in m, power loss per pole in W type S 200 P rated current In A MCB series B m Z K W m W m W 0.2 0.3 0.5 - - - - - - 42500 20000 6340 1.7 1.8 1.6 - - 10100 - - 2.5 0.75 1 1.6 - - - - - - 2500 1400 625 1.4 1.4 1.6 - 2270 1100 - 2.3 2.8 2 3 4 - - - - - - 460 211 163 1.8 1.9 2.6 619 211 163 2.5 1.9 2.6 6 8 10 61 45 14 2.2 2.9 1.4 67 45 19 2.4 2.9 1.9 104 55 21 3.7 3.5 2.1 13 16 20 13.3 9.7 7.3 2.3 2.5 2.9 - 8.2 7.3 - 2.1 2.9 - 10.9 7.3 - 2.8 2.9 25 32 40 5.6 4.1 4.0 3.5 4.2 6.4 5.6 4.1 4.0 3.5 4.2 6.4 5.6 4.1 4.0 3.5 4.2 6.4 50 63 1.2 1.4 3.0 5.6 1.2 1.3 3.0 5.2 1.8 1.3 4.4 5.2 29 System pro M Miniature circuit-breakers S 200 P Diagram of let-trough values I2 t at 230/400 V AC Miniature circuit-breakers S 200 P-B/C SK 0158 Z 94 Miniature circuit-breakers S 200 P-Z 30 SK 0157 Z 94 SK 0156 Z 94 Miniature circuit-breakers S 200 P-K Miniature circuit-breakers S 200 P 2CDC 022 160 F0205 Diagram of let-through values I2t of S 200 P-K Diagram of let-through values I2t of S 200 P-Z 2CDC 022 162 F0205 System pro M compact(R) 31 System pro M compact(R) Miniature circuit-breakers S 200 P Dimension drawings measurements in mm SK 0136 Z 01 Dimension drawings 1-pole 2-pole 1 + NA 3-pole 4-pole 3 + NA SK 0058 Z 01 S 201, S 202, S 203, S 204 1-pole 2-pole 3-pole 4-pole S2C-H10 32 S2C-H01 2CDC 022 153 F0003 2CDC 022 449 F0004 2CDC 022 448 F0004 S 201 H, S 202 H, S 203 H, S 204 H (fitted integrated auxiliary contact S2C-H10/S2C-H01) Connection: Supply optional, top or bottom, terminal designation acc. to EN 50 005. Connection drawings see left hand side System pro M compact(R) Miniature circuit-breakers S 200 P Installation and operation instructions Installation: Can be installed in any mounting position due to snap-on fixing to DIN rails EN 60 715, 35 mm width. A If miniature circuit-breakers S 200/S 200 M/S 200 P are installed without busbar, hinge the upper part into the DIN rail and push to let the lower part of the device snap into place (1). The device is released in the reverse order, after the quick fastener has been removed with a screw driver (2). B To release S 200/S 200 M/S 200 P that are cross-wired with System pro M compact busbars, first open the clamping screws. Then, pull the lower part of the S 200/S 200 M/S 200 P forwards (1) and lift it straight up (1a), then, the quick fastener (1b) will recede. C The busbar is deallocated and the S 200/S 200 M/S 200 P can be pulled out by lifting the device forwards (2). D The insertion onto busbar is done in the reverse order. First, open the clamping screws and pull out the quick fastener until it locks into place for the first time (3). Then, take the S 200/S 200 M/S 200 P device and insert it with the rear terminal side onto the pins of the System pro M compact busbar (4), turn it into the direction of the DIN rail (4a) and shift it vertically downwards (4b); this way, the quick fastener snaps back into place (4c). Caution: Do not forget to re-tighten the clamping screws. snap on detach C remove when pro M compact busbar remains in place pro M compact busbar pro M compact busbar Pin pro M compact busbar SK 0269 Z 98 pin SK 0167 Z 99 D insert when pro M compact busbar remains in place SK 0268 Z 98 quick fastener B release when pro M compact busbar remains in place SK 0267 Z 98 SK 0266 Z 98 A instal, remove without pro M compact busbar Operation: MCBs are switched on by switching the operating lever into the upper position (with respect to the text block of the nameplate). If an MCB, after having tripped, can be switched on again, the tripping is probably caused by overload. If the MCB trips again immediately when trying to reclose, a complete short-circuit, or earth fault can be assumed. Do not try to continuously re-close an existing short circuit or earth fault. The MCB trips under overload, or short-circuit or earth fault conditions, even if the operating lever is locked in the ON position (trip-free mechanism). Cleaning the device: MCBs soiled by installation work should be cleaned with a dry, or, if necessary, a damp and soapy cloth. Never use caustic agents or dissolvent. Maintenance: STOTZ miniature circuit-breakers are maintenance-free. Opening the device will lead to a loss of warranty. 33 Miniature circuit-breakers S 280 UC Special features Application notes System pro M SK 0297 B 91 Protection degree IPXXB fulfills DIN EN 50 274 (VDE 0660 Part 514). SK 0302 B 91 SK 0301 B 91 Open, captive box terminals supplied ex works, latched position, incoming and outgoing circuit. Connection possible for single, multi and finely stranded conductors from 0.75 to 35 mm2. It is also possible to connect conductors with different cross sections at the same time SK 0303 B 91 Using combined terminals, simultaneous wiring to busbar and connection to supply possible. Feeder optional, top or bottom, terminal designation according to EN 50005. 34 Miniature circuit-breakers S 280 UC Special features Application notes System pro M SK 0138 B 93 High rated switching capacity Auxiliary contacts, signal contacts/auxiliary contacts, signal contacts, shunt trips, and undervoltage releases can be retrofitted at the place of installation. Energy limiation falls below the values prescribed by the IEC by more than 50 %, the selectivity obtained is thus higher than in energy limitation class 3 SK 0298 B 91 Disconnector abilities according to EN 60 898-1, rated surge withstand capacity Uimp 4 kV (1.2/50); test voltage 6.2 kV at NN Can be used as main circuit breaker according to EN 60 947-3 due to positive position indication for each pole red = ON, green = OFF SK 0299 B 91 A padlock device prevents unauthorized switching to ON or OFF SK 0300 B 91 Integrated carrier for attaching write-on or other labels or label holders 35 System pro M High-Performance MCBs S 280(R) series for AC/DC applications S 280 UC-B Selection table B Rated current In A Ordering details Type No. Order code bbn 40 16779 EAN 6 10 16 UBmax 440 V~ 20 220 V ... - 25 S 281 UC-B 6 S 281 UC-B 10 S 281 UC-B 16 GH S281 0164 R0065 GH S281 0164 R0105 GH S281 0164 R0165 16230 2 16240 1 16250 0 5 5 5 S 281 UC-B 20 S 281 UC-B 25 GH S281 0164 R0205 GH S281 0164 R0255 16260 9 16270 8 5 5 6 10 16 S 282 UC-B 6 S 282 UC-B 10 S 282 UC-B 16 GH S282 0164 R0065 GH S282 0164 R0105 GH S282 0164 R0165 16280 7 16290 6 16300 2 5 5 5 S 282 UC-B 20 S 282 UC-B 25 GH S282 0164 R0205 GH S282 0164 R0255 16310 1 16320 0 5 5 No. of poles acc. to DIN VDE 0641 Part 11 for line protection 1 SK 0052 B 95 2 System pro M UBmax 440 V~ 20 440 V ... - 25 High-Performance MCBs S 280(R) series for AC/DC applications Price Price Weight Pack. 1 piece group 1 piece unit piece kg 0.130 10/40 0.260 5/20 S 280 UC-K Selection table K Type No. Order code bbn 40 12233 EAN 0,2 0,3 0,5 S 281 UC-K 0,2 S 281 UC-K 0,3 S 281 UC-K 0,5 GH S281 0164 R0087 GH S281 0164 R0117 GH S281 0164 R0157 63420 0 63430 9 63440 8 5 5 5 0,75 1 1,6 S 281 UC-K 0,75 S 281 UC-K 1 S 281 UC-K 1,6 GH S281 0164 R0187 GH S281 0164 R0217 GH S281 0164 R0257 63550 4 63460 6 63470 5 5 5 5 2 3 4 S 281 UC-K 2 S 281 UC-K 3 S 281 UC-K 4 GH S281 0164 R0277 GH S281 0164 R0317 GH S281 0164 R0337 63480 4 63490 3 63500 9 5 5 5 6 8 10 S 281 UC-K 6 S 281 UC-K 8 S 281 UC-K 10 GH S281 0164 R0377 GH S281 0164 R0407 GH S281 0164 R0427 63520 7 63510 8 63530 6 5 5 5 16 20 25 S 281 UC-K 16 S 281 UC-K 20 S 281 UC-K 25 GH S281 0164 R0467 GH S281 0164 R0487 GH S281 0164 R0517 63540 5 63560 3 63570 2 5 5 5 32 40 UBmax 440 V~ 50 220 V ... - 63 S 281 UC-K 32 S 281 UC-K 40 S 281 UC-K 50 GH S281 0164 R0537 GH S281 0164 R0557 GH S281 0164 R0577 63580 1 63590 0 63600 6 5 5 5 S 281 UC-K 63 GH S281 0164 R0607 63610 5 5 0,2 0,3 0,5 S 282 UC-K 0,2 S 282 UC-K 0,3 S 282 UC-K 0,5 GH S282 0164 R0087 GH S282 0164 R0117 GH S282 0164 R0157 63620 4 63630 3 63640 2 5 5 5 0,75 1 1,6 S 282 UC-K 0,75 S 282 UC-K 1 S 282 UC-K 1,6 GH S282 0164 R0187 GH S282 0164 R0217 GH S282 0164 R0257 63650 1 63660 0 63670 9 5 5 5 2 3 4 S 282 UC-K 2 S 282 UC-K 3 S 282 UC-K 4 GH S282 0164 R0277 GH S282 0164 R0317 GH S282 0164 R0337 65280 8 63680 8 63690 7 5 5 5 6 8 10 S 282 UC-K 6 S 282 UC-K 8 S 282 UC-K 10 GH S282 0164 R0377 GH S282 0164 R0407 GH S282 0164 R0427 63700 3 63710 2 63720 1 5 5 5 16 20 25 S 282 UC-K 16 S 282 UC-K 20 S 282 UC-K 25 GH S282 0164 R0467 GH S282 0164 R0487 GH S282 0164 R0517 63730 0 63740 9 63750 8 5 5 5 32 40 UBmax 440 V~ 50 440 V ... - 63 S 282 UC-K 32 S 282 UC-K 40 S 282 UC-K 50 GH S282 0164 R0537 GH S282 0164 R0557 GH S282 0164 R0577 63760 7 63770 6 63790 4 5 5 5 S 282 UC-K 63 GH S282 0164 R0607 63800 0 5 No. of poles 1 SK 0323 B 91 acc. to DIN VDE 0660 Part 101 for power circuits motors, transformers and lamps for line protection SK 0324 B 91 2 36 Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit piece kg 0.130 10/40 0.160 0.260 0.320 5/20 High-performance MCBs S 280(R) series for AC/DC applications System pro M S 280 UC-K Selection table K No. of poles 3 SK 0184 B 92 acc. to DIN VDE 0660 Part 101 for power circuits motors, transformers and lamps for line protection UBmax 440 V~ 440 V ... - SK 0185 B 92 4 UBmax 440 V~ 440 V ... - Type No. Order code bbn 40 12233 EAN 0.2 0.3 0.5 S 283 UC-K 0.2 S 283 UC-K 0.3 S 283 UC-K 0.5 GH S283 0164 R0087 GH S283 0164 R0117 GH S283 0164 R0157 73810 6 73820 5 73830 4 5 5 5 0.75 1 1.6 S 283 UC-K 0.75 S 283 UC-K 1 S 283 UC-K 1.6 GH S283 0164 R0187 GH S283 0164 R0217 GH S283 0164 R0257 73840 3 73850 2 73860 1 5 5 5 2 3 4 S 283 UC-K 2 S 283 UC-K 3 S 283 UC-K 4 GH S283 0164 R0277 GH S283 0164 R0317 GH S283 0164 R0337 73870 0 73880 9 73890 8 5 5 5 6 8 10 S 283 UC-K 6 S 283 UC-K 8 S 283 UC-K 10 GH S283 0164 R0377 GH S283 0164 R0407 GH S283 0164 R0427 73900 4 73910 3 73920 2 5 5 5 16 20 25 S 283 UC-K 16 S 283 UC-K 20 S 283 UC-K 25 GH S283 0164 R0467 GH S283 0164 R0487 GH S283 0164 R0517 73930 1 73940 0 73950 9 5 5 5 32 40 50 S 283 UC-K 32 S 283 UC-K 40 S 283 UC-K 50 GH S283 0164 R0537 GH S283 0164 R0557 GH S283 0164 R0577 73960 8 73970 7 73980 6 5 5 5 63 S 283 UC-K 63 GH S283 0164 R0607 73990 5 5 0.2 0.3 0.5 S 284 UC-K 0.2 S 284 UC-K 0.3 S 284 UC-K 0.5 GH S284 0164 R0087 GH S284 0164 R0117 GH S284 0164 R0157 74160 1 74170 0 74180 9 5 5 5 0.75 1 1.6 S 284 UC-K 0.75 S 284 UC-K 1 S 284 UC-K 1.6 GH S284 0164 R0187 GH S284 0164 R0217 GH S284 0164 R0257 74190 8 74200 4 74210 3 5 5 5 2 3 4 S 284 UC-K 2 S 284 UC-K 3 S 284 UC-K 4 GH S284 0164 R0277 GH S284 0164 R0317 GH S284 0164 R0337 74220 2 74230 1 74240 0 5 5 5 6 8 10 S 284 UC-K 6 S 284 UC-K 8 S 284 UC-K 10 GH S284 0164 R0377 GH S284 0164 R0407 GH S284 0164 R0427 74250 9 74260 8 74270 7 5 5 5 16 20 25 S 284 UC-K 16 S 284 UC-K 20 S 284 UC-K 25 GH S284 0164 R0467 GH S284 0164 R0487 GH S284 0164 R0517 74280 6 74300 1 74310 0 5 5 5 32 40 50 S 284 UC-K 32 S 284 UC-K 40 S 284 UC-K 50 GH S284 0164 R0537 GH S284 0164 R0557 GH S284 0164 R0577 74320 9 74330 8 74340 7 5 5 5 63 S 284 UC-K 63 GH S284 0164 R0607 74350 6 5 Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit piece kg 0.390 3/12 0.480 0.520 2 0.640 - with 2 poles connected in series UBmax 440 V ... 37 High-performance MCBs S 280(R) series for AC/DC applications System pro M Selection table Z Type No. Order code bbn 40 12233 EAN 0.5 1 1.6 S 281 UC-Z 0.5 S 281 UC-Z 1 S 281 UC-Z 1.6 GH S281 0164 R0158 GH S281 0164 R0218 GH S281 0164 R0258 63860 4 63870 3 63880 2 5 5 5 2 3 4 S 281 UC-Z 2 S 281 UC-Z 3 S 281 UC-Z 4 GH S281 0164 R0278 GH S281 0164 R0318 GH S281 0164 R0338 63890 1 63900 7 63910 6 5 5 5 6 8 10 S 281 UC-Z 6 S 281 UC-Z 8 S 281 UC-Z 10 GH S281 0164 R0378 GH S281 0164 R0408 GH S281 0164 R0428 63920 5 63940 3 63950 2 5 5 5 16 20 25 S 281 UC-Z 16 S 281 UC-Z 20 S 281 UC-Z 25 GH S281 0164 R0468 GH S281 0164 R0488 GH S281 0164 R0518 63960 1 63970 0 63980 9 5 5 5 32 40 UBmax 440 V~ 50 220 V ... - 63 S 281 UC-Z 32 S 281 UC-Z 40 S 281 UC-Z 50 GH S281 0164 R0538 GH S281 0164 R0558 GH S281 0164 R0578 63990 8 64000 3 64010 2 5 5 5 S 281 UC-Z 63 GH S281 0164 R0608 64020 1 5 0.5 1 1.6 S 282 UC-Z 0.5 S 282 UC-Z 1 S 282 UC-Z 1.6 GH S282 0164 R0158 GH S282 0164 R0218 GH S282 0164 R0258 64030 0 64040 9 64230 4 5 5 5 2 3 4 S 282 UC-Z 2 S 282 UC-Z 3 S 282 UC-Z 4 GH S282 0164 R0278 GH S282 0164 R0318 GH S282 0164 R0338 64100 0 64110 9 64120 8 5 5 5 6 8 10 S 282 UC-Z 6 S 282 UC-Z 8 S 282 UC-Z 10 GH S282 0164 R0378 GH S282 0164 R0408 GH S282 0164 R0428 64130 7 64140 6 64150 5 5 5 5 16 20 25 S 282 UC-Z 16 S 282 UC-Z 20 S 282 UC-Z 25 GH S282 0164 R0468 GH S282 0164 R0488 GH S282 0164 R0518 64160 4 64170 3 64180 2 5 5 5 32 40 50 S 282 UC-Z 32 S 282 UC-Z 40 S 282 UC-Z 50 GH S282 0164 R0538 GH S282 0164 R0558 GH S282 0164 R0578 64190 1 64200 7 64210 6 5 5 5 63 S 282 UC-Z 63 GH S282 0164 R0608 64220 5 5 0.5 1 1.6 S 283 UC-Z 0.5 S 283 UC-Z 1 S 283 UC-Z 1.6 GH S283 0164 R0158 GH S283 0164 R0218 GH S283 0164 R0258 74000 0 74010 9 74020 8 5 5 5 2 3 4 S 283 UC-Z 2 S 283 UC-Z 3 S 283 UC-Z 4 GH S283 0164 R0278 GH S283 0164 R0318 GH S283 0164 R0338 74030 7 74040 6 74050 5 5 5 5 6 8 10 S 283 UC-Z 6 S 283 UC-Z 8 S 283 UC-Z 10 GH S283 0164 R0378 GH S283 0164 R0408 GH S283 0164 R0428 74060 4 74070 3 74080 2 5 5 5 16 20 25 S 283 UC-Z 16 S 283 UC-Z 20 S 283 UC-Z 25 GH S283 0164 R0468 GH S283 0164 R0488 GH S283 0164 R0518 74090 1 74100 7 74110 6 5 5 5 32 40 50 S 283 UC-Z 32 S 283 UC-Z 40 S 283 UC-Z 50 GH S283 0164 R0538 GH S283 0164 R0558 GH S283 0164 R0578 74120 5 74130 4 74140 3 5 5 5 63 S 283 UC-Z 63 GH S283 0164 R0608 74150 2 5 0.5 1 1.6 S 284 UC-Z 0.5 S 284 UC-Z 1 S 284 UC-Z 1.6 GH S284 0164 R0158 GH S284 0164 R0218 GH S284 0164 R0258 74360 5 74370 4 74380 3 5 5 5 2 3 4 S 284 UC-Z 2 S 284 UC-Z 3 S 284 UC-Z 4 GH S284 0164 R0278 GH S284 0164 R0318 GH S284 0164 R0338 74390 2 74400 8 74410 7 5 5 5 6 8 10 S 284 UC-Z 6 S 284 UC-Z 8 S 284 UC-Z 10 GH S284 0164 R0378 GH S284 0164 R0408 GH S284 0164 R0428 74420 6 74430 5 74440 4 5 5 5 16 20 25 S 284 UC-Z 16 S 284 UC-Z 20 S 284 UC-Z 25 GH S284 0164 R0468 GH S284 0164 R0488 GH S284 0164 R0518 74450 3 74460 2 74470 1 5 5 5 32 40 50 S 284 UC-Z 32 S 284 UC-Z 40 S 284 UC-Z 50 GH S284 0164 R0538 GH S284 0164 R0558 GH S284 0164 R0578 74480 0 74490 9 74500 5 5 5 5 63 S 284 UC-Z 63 GH S284 0164 R0608 74510 4 5 No. of poles SK 0325 B 91 acc. to DIN VDE 0660 Part 101 for the protection of control circuits, voltage transformer circuits, semiconductor protection in the case of selective assignment and lines 1 SK 0326 B 91 2 UBmax 440 V~ 440 V ... - SK 0186 B 92 3 UBmax 440 V~ 440 V ... - SK 0187 B 92 4 UBmax 440 V~ 440 V ... - Rated current In A Ordering details UBmax 440 V ... - with 2 poles connected in series 38 S 280 UC-Z Price Price Weight Pack. 1 piece group 1 piece unit piece kg 0.130 10/40 0.160 0.260 5/20 0.320 0.390 3/12 0.480 0.520 0.640 2 System pro M Additional devices for miniature circuit-breakers of the S 280 (R) series Selection table Ordering details Type No. Order code bbn 40 12233 EAN GH S270 1937 R0005 33140 1 5 0.05 1 GH S280 1911 R0001 GH S280 1911 R0002 GH S280 1911 R0003 GH S280 1911 R0004 GH S280 1911 R0005 GH S280 1911 R0006 42970 7 42980 6 79360 0 43000 0 43010 9 79370 9 5 5 5 5 5 5 0.09 0.09 0.09 0.09 0.09 0.09 1 1 1 1 1 1 GH S280 1909 R0001 GH S280 1909 R0002 42930 1 42940 0 5 5 0.145 0.145 1 1 Price Price Weight Pack. 1 piece group 1 piece unit piece kg Auxiliary switch, low power 1S S2-H10 kL Undervoltage release SK 0330 B 91 12 V DC 24 V AC/DC 48 V AC/DC 110 V AC/DC 220 V AC/DC 380 V AC S 2-A ... S2-UA 12 S2-UA 24 S2-UA 48 S2-UA 110 S2-UA 220 S2-UA 380 Shunt release 12... 60 V AC/DC S2-A1 S2-A2 100...415 V AC and 110...250 V AC/DC 39 System pro M Cu Busbar systems (no connection piece required) (end caps see page 40) Capacity mm2 SK 0139 Z96 SZ-KS 1/12, SZ-KS 1/56 SZ-KS 2/12, SZ-KS 2/56 1 pole with 1 phase SZ-PSB 3 N, SZ-PSB 4 N SZ-PSB 11 N, SZ-PSB 12 N 1- or 3 pole with 3 phases SK 0061 Z91 SK 0183 Z97 Shock-resistant busbars and comb busbars for MCBs with combined terminals Ordering details Length- No.suppl. x Pole Type No. mm Universal comb busbar for MCBs: supply: Order code bbn 40 12233 EAN Cu No. Price Price Weight Pack. 1 piece group 1 piece unit piece kg 1 pole 1 phase 12 12 207 988 12 x 1 SZ-KS 1/12* 56 x 1 SZ-KS 1/56 GJ I232 2322 R0001 GJ I232 2322 R0002 59790 1 59800 7 0.023 0.110 15 15 0.015 100 0.073 50 24 24 207 988 12 x 1 SZ-KS 2/12* 56 x 1 SZ-KS 2/56 GJ I232 2322 R0003 GJ I232 2322 R0004 59810 6 59820 5 0.046 0.220 15 15 0.031 100 0.138 50 36 988 16 16 202 1007 56 x 1 SZ-VB 45.32 GJ I232 2148 R0001 59720 8 0.330 15 0.233 50 12 x 1 SZ-KS 18/12 N 56 x 1 SZ-KS 18/56 N GH V036 0875 R0041 GH V036 0875 R0042 74530 2 74520 3 0.071 0.320 15 15 0.073 0.300 50 50 SK 0095 Z96 * with shock protection cover SZ-KS 3/39 N SZ-KS 4/39 N 1 pole + aux.switch with 1 phase Busbar for MCBs: supply: 1- or 3 pole 3 phases end caps: PSB-END 6 10 10 213 1058 4 x 3 SZ-PSB 3 N 20 x 3 SZ-PSB 4 N GH L520 1915 R0005 GH L520 1915 R0006 29400 3 0.085 29410 2 0.505 15 15 0.082 0.468 30 10 16 16 213 1058 4 x 3 SZ-PSB 11 N 20 x 3 SZ-PSB 12 N GH L520 1916 R0005 GH L520 1916 R0006 29420 1 0.160 29430 0 0.720 15 15 0.136 0.70 30 10 SK 0096 Z96 Use SZ-BSK 5 shock protection cover, see page 40 SZ-PSB 46 N SZ-PSB 48 N 1 pole + aux.switch with 3 phases 1 pole with auxiliary switch 1 phase end caps: END 1.1 10 1020 39 x 1 SZ-KS 3 /39 N GH V036 0874 R0060 55130 9 0.205 15 0.206 10 16 1020 39 x 1 SZ-KS 4/39 N GH V036 0874 R0062 55150 7 0.320 15 0.283 10 SK 0097 Z96 1 pole with auxiliary switch 3 phases end caps: PSB-END 3 10 1018 13 x 3 SZ-PSB 46 N* GH V036 0874 R0024 54870 5 0.505 15 0.451 10 16 1018 13 x 3 SZ-PSB 48 N GH V036 0874 R0026 54890 3 0.760 15 0.620 10 * L style 3 pole with auxiliary switch 3 phases SK 0169 Z98 SZ-PSB 49 N, SZ-PSB 50 N SZ-PSB 51 N, SZ-PSB 52 N 3 pole + aux.switch with 3 phases SZ-PSB 130 N 4 pole + aux.switch with 3 phases + N 10 10 176 980 3 x 3 SZ-PSB 49 N 16 x 3 SZ-PSB 50 N* GH V036 0874 R0027 GH V036 0874 R0028 54900 9 54910 8 0.105 0.505 15 15 0.076 0.442 30 10 16 16 176 980 3 x 3 SZ-PSB 51 N 16 x 3 SZ-PSB 52 N GH V036 0874 R0029 GH V036 0874 R0030 54920 7 54930 6 0.152 0.760 15 15 0.104 0.632 30 10 * L style 4 pole with auxiliary switch 3 phases + N 16 1020 13 x 4 SZ-PSB 130 N bbn-No. 40 16779 40 end caps: PSB-END 3 GH V036 0503 R0040 40330 6 1.32 end caps: PSB-END 4 15 0.810 10 System pro M Cu Busbar systems SK 0074 Z91 Shock-resistant busbars for MCBs with combined box terminal SK 0098 Z96 (no terminal required) (end caps see below) Capacity mm2 SZ-PSB 53 N, SZ-PSB 54 N SZ-PSB 55 N, SZ-PSB 56 N 1 pole + NA or 2 pole with 2 phases or 1 phase + N Ordering details Length- No.suppl. x Pole Type No. mm SK 0099 Z96 for MCBs: supply: end caps: PSB-END 3 212 1035 6 x 2 SZ-PSB 53 N 29 x 2 SZ-PSB 54 N GH V036 0874 R0031 GH V036 0874 R0032 54940 5 54950 4 0.070 0.320 15 15 0.078 30 0.403 10 16 16 212 1035 6 x 2 SZ-PSB 55 N 29 x 2 SZ-PSB 56 N GH V036 0874 R0033 GH V036 0874 R0034 54960 3 54970 2 0.115 0.545 15 15 0.106 30 0.534 10 2 pole with auxiliary switch 1 phase + N or 2 phases 1044 24 x 2 SZ-PSB 92 N SK 0100 Z96 SK 0101 Z96 Price Price Weight Pack. 1 piece group 1 piece unit piece kg 10 10 16 SZ-PSB 61 N, SZ-PSB 62 N SZ-PSB 63 N, SZ-PSB 64 N 3 pole + NA or 4 pole with 4 phases or 3 phases + N Cu No. 1 pole + NA or 2 pole 1 phase + N or 2 phases SZ-PSB 92 N 2 pole + auxiliary switch with 2 phases 1 pole + NA + auxiliary switch, with 2 phases or 1 phase + N + auxiliary switch SZ-PSP 58 N SZ-PSB 60 N 1 pole + NA with 4 phases or 3 phases + N Order code bbn 40 12233 EAN GH V036 0875 R0010 55380 8 0.680 end caps: PSB-END 3 15 0.650 10 end caps: 1 pole + NA 3 phases + N PSB-END 4 10 1056 29 x 2 SZ-PSB 58 N GH V036 0874 R0036 54990 0 0.803 15 0.626 10 16 1056 29 x 2 SZ-PSB 60 N GH V036 0874 R0038 55010 4 1.205 15 0.861 10 3 pole + NA or 4 pole 3 phases + N end caps: PSB-END 4 10 10 212 1056 3 x 4 SZ-PSB 61 N 15 x 4 SZ-PSB 62 N GH V036 0874 R0039 GH V036 0874 R0040 55020 3 55030 2 0.120 0.803 15 15 0.112 30 0.650 10 16 16 212 1056 3 x 4 SZ-PSB 63 N 15 x 4 SZ-PSB 64 N GH V036 0874 R0041 GH V036 0874 R0042 55040 1 55050 0 0.241 1.205 15 15 0.156 30 0.884 10 15 15 0,003 10 0,003 10 15 15 15 15 0.006 0.001 0.001 0.001 Shock-protection caps for busbars with fork-type connection 5-teilig 5-teilig SZ-BSK 5 SK 0053 Z95 SZ-BSK 5 * SZ-BSK GH V036 0505 R0001 2CDL 200 001 R0011 15430 7 42000 6 * for busbars SZ-PSB 3 N, 4 N, 11 N and 12 N End caps for shock-protected busbars PSB-END SK 0100 B99 SK 0104 Z97 SZ-BSK PSB-END 6 PSB-END 3 PSB-END 4 END 1.1 GH L520 1921 R0007 GH V036 1325 R0001 GH V036 1325 R0002 2CDL 200 011 R0011 51453 8 55630 4 55640 3 63891 3 - - - - 50 50 50 50 bbn-No. 40 16779 41 Busbar terminals Flexible wiring bridges System pro M SK 0247 Z02 SK 0066 Z94 Capacity mm2 SK 0068 Z94 SZ-AS 4 I SZ-AS 8 I SK 0069 Z94 SZ-AS 5 I SZ-AS 10 I SK 0096 Z98 SZ-Ast 25 I SZ-Ast 50 I SK 0119 Z01 SZ-Ast 6 I SZ-Ast 9 I SK 0118 Z01 SZ-AS 2 I SZ-Ast 95 Type of connect. Terminal lug L/mm SK 0187 Z02 SK 0188 Z02 SZ-Ast 55 I Ordering details Type No. Order code bbn 40 12233 EAN Cu No. Price Price Weight Pack. 1 piece group 1 piece unit piece kg Terminals insulated 6-35 6-25 6-25 6-50 6-50 fork fork fork fork fork 10 15 15 15 15 SZ-AS 2 I* SZ-AS 4 I* SZ-AS 5 I* SZ-AS 8 I* SZ-AS 10 I* GH V036 0501 R0011 GH V036 0501 R0005 GH V036 0501 R0014 GH V036 0501 R0008 GH V036 0501 R0017 39330 0 12410 2 57012 1 25950 7 58295 7 15 15 15 15 15 0.023 0.011 0.012 0.014 0.014 30 50 50 50 50 6-25 6-25 6-25 6-50 6-50 6-50 pin pin pin pin pin pin pin pin pin pin 15 30 30 15 15 32 SZ-Ast 25 I SZ-Ast 9 I SZ-Ast 6 I SZ-Ast 50 I SZ-Ast 55 I SZ-Ast 12 I SZ-Ast 55 U SZ-Ast 50 U SZ-Ast 95* SZ-Ast 95 gk* 2CDL 200 001 R2501 2CDL 200 001 R2502 2CDL 200 001 R2503 2CDL 200 001 R5001 2CDL 200 002 R5002 2CDL 200 001 R5003 2CDL 200 489 R5002 2CDL 200 489 R5001 GH V036 0501 R0013 GH V036 0501 R0012 64993 3 65109 7 65110 3 64994 0 64995 7 64996 4 64822 6 64821 9 52262 5 52261 8 15 15 15 15 15 15 15 15 15 15 0.011 0.014 0.014 0.014 0.024 0.014 0.015 0.015 0.067 0.067 50 50 50 50 50 50 50 50 3 3 15 0.024 10 25-95 25-95 18 12 bbn-No. 40 16779 SZ-Ast 95 gk Cu * not applicable to pro M compact Feeder Terminal Safe from touch by the back of the hand / finger acc. to DIN VDE 0660 Part 514. Single-pole terminals can be butt-mounted as multipole terminals. SZ-ESK 2 6-35 2CDL 200 001 R3501 96920 3 Cu No. Order code bbn 40 12233 EAN 55650 2 55670 0 55680 9 55690 8 55700 4 0.006 0.010 0.014 0.022 0.029 bbn-No. 40 16779 SK 0133 B99 SZ-Ast 12 I Capacity mm2 SZ-ESK 2 Lengthsuppl. mm Ordering details Type No. Price Price Weight Pack. 1 piece group 1 piece unit piece kg Wiring bridges (black) with cable lug SZ-DB 121 2CDC 061 179 F0004 SZ-DB 123 2CDC 061 180 F0004 SZ-DB 125 N 2CDC 061 181 F0004 6 10 6 10 10 125 135 260 330 SZ-DB 121 SZ-DB 122 N SZ-DB 231 N SZ-DB 232 N SZ-DB 311 GH V036 1425 R0001 GH V036 1425 R0031 GH V036 1425 R0032 GH V036 1425 R0033 GH V036 1425 R0034 15 15 15 15 15 0.025 1000/50 500/25 0.02 500/25 0.02 250/25 0.04 100/25 0.05 with cable lug and ultrasonically compressed cable ends* 2CDC 062 360 F0004 6 10 6 10 Example 1 Connection of devices with different module width with SZ-DB 121 or 122 42 125 135 260 SZ-DB 123 SZ-DB 124 N SZ-DB 235 SZ-DB 236 GH V036 1425 R0006 GH V036 1425 R0035 GH V036 1425 R0036 GH V036 1425 R0037 55660 1 55710 3 55720 2 55730 1 0.007 0.012 0.014 0.024 15 15 15 15 0.01 0.02 0.02 0.04 1000/50 15 15 15 15 15 0.01 0.02 0.02 0.04 0.05 1000/50 500/25 500/25 250/25 with ultrasonically compressed cable ends* 6 6 10 10 10 125 260 135 260 330 SZ-DB 125 N SZ-DB 233 N SZ-DB 126 N SZ-DB 234 N SZ-DB 312 GH V036 1425 R0038 GH V036 1425 R0039 GH V036 1425 R0040 GH V036 1425 R0041 GH V036 1425 R0042 55740 0 55750 9 55760 8 55770 7 55780 6 0.007 0.015 0.013 0.025 0.032 * Advantages: - smaller dimensions although capacity remains the same (more space inside the terminal) - hardly any contact resistance - improved safety, connector sleeve may loosen in highly unfavorable circumstances 500/25 500/25 250/25 100/25 Wiring kit Neutral (N) and Protective conductor (PE) Busbars System pro M Capacity mm2 No. of poles Ordering details Type No. Order code bbn 40 16779 EAN Cu Cu No. Price Price Weight Pack. 1 piece group 1 piece unit piece kg Wiring kit ** SK 0151 Z96 SK 0152 Z96 For the wiring of component rows in the consumer unit with 125 mm spacing. SZ-VS 1 10 10 10 10 10 SZ-VS 3 1 pole 1 pole 2 pole 3 pole 4 pole SZ-VS 1 SZ-VS 1B* SZ-VS 2 SZ-VS 3 SZ-VS 4 GH V036 0504 R0001 GH V036 0504 R0011 GH V036 0504 R0002 GH V036 0504 R0003 GH V036 0504 R0004 28790 6 49670 4 28800 2 28810 1 28820 0 0.022 0.022 0.044 0.066 0.088 15 15 15 15 15 0.03 0.03 0.06 0.10 0.13 30 30 30 30 30 15 0.047 50 SK 0255 Z98 * insulation blue Connection kit** for 3-pole miniature circuit-breakers of the S 2 series and motor circuit-breaker MS 225/325. If used without accessories, use filler piece SZ-FST 2. Connection kit SZ-SM 3 SZ-SM 3 GH V036 0504 R0005 41580 4 Order code bbn 40 12233 EAN 0.02 SK 0101 B00 ** not for System pro M compact Input Output Ordering details mm mm Type No. Price Price Weight Pack. 1 piece group 1 piece unit piece kg Neutral or protective-conductor terminals without insulation holder SZ-KLB 8, 12, 16, 24 1 x 16 1 x 16 SK 0082 B91 1 x 35 1 x 35 2 x to 16 6 x to 10 2 x to 16 10 x to 10 4 x to 16 12 x to 10 4 x to 16 20 x to 10 SZ-KLB 8 GJ I232 0131 R0001 59660 7 15 0.025 30 SZ-KLB 12 GJ I232 0071 R0013 59530 3 15 0.035 30 SZ-KLB 16 GJ I232 0072 R0017 59540 2 15 0.077 30 SZ-KLB 24 GJ I232 0073 R0016 59550 1 15 0.100 30 15 0.003 100 SZ-Ktr Holder for SZ-KLB terminals SK 0059 B91 for screw fixing for SZ-KLB 8 and 12 each 1 piece required for SZ-KLB 16 and 24 each 2 pieces required SZ-Ktr with KLB SZ-Ktr GJ I202 4027 R0001 59450 4 0.42 Neutral and protective-conductor terminals with insulation holder for quick fixing onto mounting rails EN 50 022 Neutral conductor with insulation holder blue; type C safe from finger touch, conductor openings one side closed SK 0087 B02 1 x 16 1 x 16 1 x 16 1 x 16 6 x 16 11 x 16 6 x 16 6 x 16 SZ-N 6/3 SZ-N 11/3 SZ-N 6/3 C SZ-N 11/3 C GH V036 0876 R0001 GH V036 0876 R0002 GH V036 0876 R0011 GH V036 0876 R0012 55570 3 55580 2 57095 4 57096 1 15 15 15 15 0.027 0.043 0.028 0.046 20 20 20 20 Protective conductor with insulation holder green/yellow; type C safe from finger touch, conductor openings one side closed SK 0084 B91 SZ-N6/3 1 x 16 1 x 16 1 x 16 1 x 16 6 x 16 11 x 16 6 x 16 11 x 16 SZ-PE 6/3 SZ-PE 11/3 SZ-PE 6/3 C SZ-PE 11/3 C GH V036 0876 R0004 GH V036 0876 R0005 GH V036 0876 R0014 GH V036 0876 R0015 55600 7 55610 6 57097 8 57098 5 15 15 15 15 0.027 0.043 0.028 0.046 20 20 20 20 bbn-No. 40 16779 SZ-N11/3 43 Device mounting rails and fixing materials System pro M DSW 6 DSW 4 Length supplied Ordering details mm Type No. Order code bbn 40 12233 EAN Price Price Weight Pack. 1 piece group 1 piece unit piece kg Mounting rails SK 0100 B00 DSW 3 DSW 2 SK 0087 B91 DSW 1 SKV-GTS 1 Mounting rails (DIN EN 60 715 - 35 x 7.5 mm) for individual installation with 2 screws onto an even surface (1 module = 17.5 mm) for 1 module for 2 modules for 3 modules for 4 modules for 6 modules DSW 1 DSW 2 DSW 3 DSW 4 DSW 6 GH S210 1926 R0001 GH S210 1926 R0002 GH S210 1926 R0003 GH S210 1926 R0004 GH S210 1926 R0006 13580 6 13590 5 13600 1 13610 0 13620 9 5 5 5 5 5 0.060 0.012 0.018 0.024 0.036 10 10 10 10 10 04090 2 5 0.09 40 SK 0088 B91 Mounting rail DIN EN 60 715, 35 x 7.5 mm, material thickness 1 mm, surface-protected, sendzimir / electrogalvanized. 241 SKV-GTS 1 GH L110 1915 R0001 SZ-SI 45.460 SK 0089 B91 Mounting rail DIN EN 60 715, 35 x 7.5 mm, material thickness 1 mm, surface hot-dip galvanised. 1000 SZ-SI 45.460 GJ I232 2218 R0001 59730 7 5 0.35 10 2000 SZ-TS 7,5 L2 GJ I232 2218 R0007 59760 4 5 0.70 20 SK 0090 B91 SZ-TS 7.5 L2 2000 SZ-SI 45.472 GJ I232 2218 R0010 59780 2 5 1.30 10 2000 SZ-TS 15 L2 GJ I232 2218 R0009 59770 3 5 0.78 10 SK 0091 B91 SZ-SI 45.472 Mounting rail DIN EN 60 715, 35 x 15 mm, material thickness 1.5 mm, surface hot-dip galvanised. SZ-FB 45.53-1 SZ-FB 45.53-3 44 SK 0092 B00 SZ-TS 15 L2 Catch spring for fixing devices onto mounting rails (DIN EN 60 715, 35 x 7.5 mm) for screw M4 SZ-FB 45.53-3 GJ I184 2013 P0003 64560 2 5 0,03 50 for screw M5 SZ-FB 45.53-1 GJ I184 2013 P0004 64580 0 5 0,03 50 Blinding and sealing plates Filler pieces SK 0045 B91 System pro M SZ-BP SZ-BP 2 SZ-VP 1500 Width of cover mm Ordering details Type No. Order code bbn 40 12233 EAN Price Price Weight Pack. 1 piece group 1 piece unit piece kg Blanking plates for device covers with material thickness from 1 to 3 mm, spacing: 1 module = 17.5 mm; color: gray RAL 7035, white RAL 9001 SK 0100 B91 SZ-BP 1 Cutoutheight/color mm 46/gray 46/white 46/gray 213 17.5 17.5 SZ-BP 1 SZ-BP SZ-BP 2 GH L530 1904 R0001 GH S270 1913 R0001 GH S270 1913 R0002 06050 4 12629 7 12861 1 5 5 5 0.028 100 0.005 0.005 60290 2 5 0.366 10 bbn-No. 80 00126 SK 0090 B00 Sealing plate seal-proof obstruction of stamped-out device covers. Detachable only from the inside of the device cover. Can be used for device covers with 1.5 to 3 mm material thickness. END SK 0103 B91 46/gray SZ-FDT 2 1500 SZ-VP 1500 GJ I995 9038 R0001 End bracket To prevent lateral movements of modular devices onto mounting rails acc. to DIN EN 60 715, 35 x 7.5 mm. SK 0105 B91 END GJ I100 1814 R0001 59090 2 5 0.02 50 Filler pieces Serves - among other things - the heat dissipation of tightly mounted devices with intense heat development. Width 8.75 mm, as spacer, two different heights, knock-out type, for mounting rails acc. to DIN EN 60715, 35 x 7.5 mm. SZ-FST 2 + SZ-FDT 2 8.75 SZ-FST 2 GH L530 1908 R0002 06070 2 5 0.01 25 5 0.002 25 SK 0184 B91 Spring piece Holder for device covers, various distance heights (in connection with filler piece FST 2) SZ-FDT 2 GH L530 1908 R0005 06080 1 SZ-FST Filler piece SZ-KA 20 SK 0194 Z98 Two different heights, cutout, for mounting rails acc. to DIN EN 60 715, 35 x 7.5 mm for miniature circuit-breakers S 220 (3 different heights) SZ-FST GJ I148 0003 R0001 59410 8 5 0.01 25 for S 260/S 270 IP 20 SZ-KA 20 GH S270 6612 P0002 45200 7 5 0.02 10 bbn-No. 40 16679 * to be discontinued 8.75 2CDC 023 191 F0003 Terminal covers* Rotary actuator For the actuation of 2-, 3- or 4 pole miniature circuit-breakers in closed consumer units; for drive axles of 5 or 6 mm2 (square) S2C-DH S2C-DH GH S200 1901 R0003 57960 5 5 0.175 1 45 Locking device Terminal covers System pro M Ordering details Description SK 0091 B00 Type No. Order code bbn 40 12233 EAN Price Price Weight Pack. 1 piece group 1 piece unit piece kg Elevation piece to account for the difference between modular devices with a mounting height of 68 mm and power miniature circuitbreakers of the S 210 series (83 mm). SZ-ES 68/83 SZ-ES 68/83 GH V021 1425 R0001 53390 9 5 0.003 100 SK 0108 B91 Locking device for miniature circuit-breakers and switches for the protection against unauthorised or unsafe operation of the operating lever. An adaptor makes it possible to block the operating lever whether switched ON or OFF. The lever is blocked with a padlock having a bar cross section of 3 or 6 mm max. For multipole devices, one lock may be fitted per pole. The lock adaptor can be used for all miniature circuit-breakers of the S 220, S 280 series as well as all E 220 and 270 switches. SA 1 3 mm SA 1 6 mm SA 1E SA 1/S 290 GJ F110 1903 R0001 GJ F110 1903 R0004 GJ F110 1903 R0007 58760 5 58790 2 58261 2 5 5 5 0.004 0.004 0.004 10 10 10 padlock with 2 keys SA 2 GJ F110 1903 R0002 58770 4 5 0.02 10 padlock, identical locking with 2 keys SA 2 i GJ F110 9999 R0001 96940 1 5 0.02 10 lock adaptor incl. padlock with 3 keys in transparent box SA 3 GJ F110 1903 R0003 58780 3 5 0.05 10 SK 0109 B91 lock-out latch for padlock bar for S 290 SA 2 bbn-No. 40 16779 Terminal cover KA 27 overall protection against electric shock. Suitable for switchgear according to DIN VDE 0106 Part 100 and BGV A2. Front parts can be snapped onto mounting rails EN 60 715, 35 mm. The hoods are 475 mm = 27 modules (17.5 mm each), knockouts inside, per module to customize parts. Front part, 1 piece Hood, 1 piece KA 27 H + KA 27 S KA 27 H KA 27 S GH S210 1933 R0001 GH S210 1934 R0001 13630 8 13640 7 5 5 0.104 0.027 10 10 SK 0112 B91 Terminal covers with base plate, IP 40 degree of protection Material: high-impact and flame retardant (UL 94 V-0), color: white (RAL 9001), glow-wire test 960C / 1760F according to IEC 695-2-1 PCD 2 N SK 0077 B96 SK 0076 B96 The base plate is fitted with an integrated mounting rail for snap-on devices, e.g. miniature circuit-breakers, rcd, modular devices, etc. for 2 modules for 4 modules for 6 modules for 8 modules PCD 2 N PCD 4 N PCD 6 N PCD 8 N GH S270 1921 R0002 GH S270 1921 R0004 GH S270 1921 R0006 GH S270 1921 R0008 11869 8 11872 8 11877 3 14222 8 5 5 5 5 0.09 0.15 0.2 0.7 1 1 1 1 12502 3 12492 7 5 5 0.017 0.079 1 1 PCD 4 N Terminal blocks for terminal covers PCD for PCD 4 N and 6 N for PCD 8 N SK 0079 B96 bbn-No. 80 00126 PCD 8 N 46 KL-PCD 4/6 KL-PCD 8 GH S270 1912 R0004 GH S270 1912 R0008 Terminal cover Flange frame Insulation housing System pro M Ordering details Description Type No. Order code bbn 40 12233 EAN Price Price Weight Pack. 1 piece group 1 piece unit piece kg Installation kit for flange fixing comprises: flange frame, fixing bolts and mounting rail for miniature circuit-breakers of the S 280 and S 220 series for 2 modules for 5 modules for 10 modules S 500-ME 1 S 500-ME 2 S 500-ME 3 GH S500 1008 R0001 GH S500 1008 R0002 GH S500 1008 R0003 48450 8 48460 7 48470 6 3 3 3 0.097 1 0.097 1 0.097 1 3 0.013 10pc.set Terminal for rear connection of main contacts in the case of front-mounted installations to 25 mm2 S 500-K 1 GH S500 1210 R0001 48530 7 Measurements in mm SK 0127 B92 Flush frame SK 0018 B98 SK 0131 Z 94 S 500-ME 2 Style with knockout O in mm QES 10/3 N Cable entry fittings Ordering details Type No. Order code bbn 80 00126 EAN Price Price Weight Pack. 1 piece group 1 piece unit piece kg Insulation housing IP 55 includes mounting rail acc. to DIN EN 60 715 and cable entry fittings without N + PE terminals (see SMO) Material: high-impact and flame retardant (UL 94 V-0), color gray (RAL 7035), glow-wire test 960C/1760F according to IEC 695-2-1 SK 0019 B98 Housing for 4 modules 2 x O 27 2 QES 4/3 N GH L111 2304 R0013 11925 1 5 0.370 18 QES 6/3 N GH L111 2306 R0013 11931 2 5 0.440 12 QES 10/3 N GH L111 2310 R0013 11937 4 5 0.690 10 5 5 5 0.093 10 0.125 10 0.105 10 Housing for 6 modules QES 4/3 N 2 x O 27 2 Housing for 10 modules SK 0089 Z98 6 x O 32 SMO ... 3 N + PE-Terminals for QES (IP 55) Neutral and protective conductor terminals with insulation holder for screw-fixing for QES 4/3 N for QES 6/3 N for QES 10/3 N SMO 4 SMO 6 SMO 10 GH L430 1910 R0004 GH L430 1910 R0006 GH L430 1910 R0010 11976 3 11979 4 11982 4 47 Identification materials for pro M devices System pro M Description Ordering details Type No. bbn 40 12233 EAN Order code Price Price Weight Pack. 1 piece group 1 piece unit piece kg SK 0187 B91 Individual identification labels consist of transparent label holders and insertable marked or blank paper labels. Can be used for e.g. switches, pushbuttons, indicator lights, latching relays, installations relays and miniature circuit-breakers, rcd and ABB i-bus EIB components. ST SK 0120 B91 ST + ST-E label holder snap-on ST GH S210 1945 R0002 13820 3 5 100 label (1 set= 300 pieces) ST-E GH S210 1946 R0002 13830 2 5 1 set label numbered 1 - 100 (1 set = 1 - 100) ST-EN GH S210 1946 R0003 64530 5 5 1 set Identification label mats 40 labels each, marked or blank. Blank label mats can be labeled by hand with an indelible, waterproof pen or with computerised labeling systems (plotters). SZ-KZS SK 0018 Z94 Identification labels blank SZ-KZS GH S210 1946 R0004 00850 1 5 0.007 30 numbered 1 - 40 SZ-KZS/1 GH S210 1946 R0005 00860 0 5 0.007 30 numbered 41 - 80 SZ-KZS/2 GH S210 1946 R0006 00870 9 5 0.007 30 numbered 81 - 120 SZ-KZS/3 GH S210 1946 R0007 00880 8 5 0.007 30 numbered 121 - 160 SZ-KZS/4 GH S210 1946 R0008 00890 7 5 0.007 30 with pictograms SZ-KZS/5 GH S210 1946 R0009 00900 3 5 0.007 30 numbered 2 x 1 - 20 SZ-KZS/6 GH S210 1946 R0010 05080 7 5 0.007 30 numbered 4 x 1 - 10 SZ-KZS/9 GH S210 1946 R0013 39050 7 5 0.007 30 numbered 4 x 11 - 20 SZ-KZS/10 GH S210 1946 R0014 39060 6 5 0.007 30 numbered L1 SZ-KZS/11 GH S210 1946 R0015 52484 1 5 0.007 30 numbered L2 SZ-KZS/12 GH S210 1946 R0016 52485 8 5 0.007 30 numbered L3 SZ-KZS/13 GH S210 1946 R0017 52486 5 5 0.007 30 Customized labels on request: Minimum order 50 mats, otherwise low-quantity surcharge. 48 SK 0004 Z94 SK 0162 Z93 SK 0163 Z93 SK 0164 Z93 SK 0165 Z93 SK 0166 Z93 SK 0202 B93 bbn-No. 40 16779 System pro M Miniature circuit-breakers S 280 UC Technical Data Specifications: DIN VDE 0641, DIN VDE 0660 Part 101, BS 3871, IEC 898, EN 60 898, IEC 947-2, DIN EN 50 125-1, UL 1077, CSA C 22.2 No 235 No. of poles: 1, 2, 3, 4 Tripping characteristics: B, K, Z Nominal current In: 0.2 ... 63 A Nominal voltage Un: AC 1-pole AC multipole 230 V 400 V Max. Operating voltage UBmax: AC Un + 10% DC 1-pole DC 2-pole 220 V 440 V acc. to UL 1077 and CSA 22.2: AC multipole DC 1-pole DC 2-pole 480 V 250 V 500 V Min. Operating voltage UBmin: 12 V , 12 V - Rated switching capacity: see page 49 Frequency: 16 2/3 ... 60 Hz Insulation coordination: acc. to DIN VDE 0110 Part 1 and 2 - Overvoltage category: III - Pollution degree: 2 - Surge voltage: 5 kV (1.2/50 s) - Impulse alternating voltage: 3 kV (50/60 Hz) Housing: insulation material rating I (CTI M 600) acc. to DIN IEC 112/VDE 0303 Part 1, RAL 7035 Operating lever: insulation material rating I (400 m CTI l 600) black, sealable Protection acc. to DIN VDE 0100: IP 20, in the distribution board IP 40 Protection acc. to VDE 0140: IPXXB Dimensions: acc. to DIN 43 880, size code 1 Depth of device: 68 mm Mounting position: optional Fixing: snap-on onto mounting rail EN 50 022, 35 mm screw-fixing onto mounting rail Connection: Combined box terminal top and bottom. Suitable for connecting single, multi and finely stranded conductors of 0.75 to 35 mm (max. 25 mm if also connected to rails of 3 mm max.; from 0.75 mm with sleeve and from 1.5 mm without sleeve). Can be used as feeder terminal up to 140 A Tightening torque: 2 Nm Mechanical service life: 20.000 operations Service life at rated load In 0.2 ... 63 A (S 280 UC): 1.000 operations Climatic resistance acc. to DIN 40 046 and IEC 68-2: constant climate 23/83, 40/93, 55/20 [C/RH] alternating climate 25/95 - 40/93 [C/RH] Storage temperature: Tmax + 70 C/158F, Tmin - 50 C/-58F Ambient temperature: Tmax + 55C/131F, Tmin - 25C/-13F Shock resistance: 30 g, at least two impacts, shock duration 13 ms Vibration resistance acc. to DIN IEC 68-2-6: 5 g, 20 frequency cycle 5 ... 150 ... 5 Hz at 0.8 In Position indication acc. to IEC 73: OFF = green, ON = red Weight: see Selection tables 49 System pro M High performance miniature circuit-breakers S 280 UC for AC/DC applications Rated switching capacity Operating sequence for B acc. to DIN VDE 0641 Part 12 for K acc. to DIN VDE 0660 Part 101/p-2. For the short-circuit rupturing capacities indicated the time constant is T = L/R 15 ms in the case of DC; in the case of AC, it is 10 kA: cos 0.6 for 6 kA: cos 0.7 - for 4.5 kA and for 3 kA: cos 0.8 - for < 3 kA: cos 0.9. in the case of DC to 60 V ... 110 V ... 220 V ... to 60 V ... 110 V ... 220 V ... 440 V ... Max. back-up protection; Utilization category gL (DIN VDE 0636/IEC 269) B Z, K Z, K 14 kA unlimited 14 kA 10 kA unlimited 10 kA 6 kA unlimited 6 kA 25 kA unlimited 25 kA 20 kA unlimited 20 kA 10 kA unlimited 10 kA 6 kA unlimited 6 kA 100 A not required 35 A Z, K 6 ... 8 A Z, K 10 ... 40 A Z, K 50 ... 63 A 14 kA 14 kA 10 kA 10 kA 10 kA 6 kA 6 kA 6 kA 4,5 kA 25 kA 25 kA 20 kA 20 kA 20 kA 14 kA 10 kA 10 kA 6 kA 6 kA 6 kA 4,5 kA 63 A 100 A 125 A in the case of AC to 60 V 133 V 230 V to 60 V 133 V 230 V 400 V B Z, K Z, K 10 kA unlimited 10 kA 10 kA unlimited 10 kA 6 kA unlimited 6 kA 10 kA unlimited 10 kA 10 kA unlimited 10 kA 10 kA unlimited 10 kA 6 kA unlimited 6 kA 100 A not required 35 A 10 kA 10 kA 6 kA 10 kA 10 kA 6 kA 6 kA 6 kA 4,5 kA 10 kA 10 kA 10 kA 10 kA 10 kA 6 kA 10 kA 10 kA 6 kA 6 kA 6 kA 4,5 kA 63 A 100 A 125 A S 280 UC 1pole 6 ... 25 A 0.2 ... 2 A 3 ... 4 A 6 ... 25 A 0.2 ... 2 A 3 ... 4 A Z, K 6 ... 8 A Z, K 10 ... 40 A Z, K 50 ... 63 A 2pole Back-up protection is necessary only if the solid short-circuit current to be expected at the place of installation may exceed the rated switching capacity indicated. Z as of 0.5 A Auxiliary switch S2 - H.. (small power) acc. to DIN VDE 0660 Part 200/7.92; EN 60 947-5-1 Ith = 0.5 A minimum switching capacity AC 12 DC 12 Ue 24 V 12 V Ie 4 mA 8 mA Ue 24 V 12 V Ie 4 mA 8 mA Operating voltage UBmin: 12 V Insulation coordination: acc. to DIN VDE 0110 Part 1 and 2 - Overvoltage category: III - Pollution degree: 2 Connection capacity: to 2 x 1.5 mm 50 , 12 V ... System pro M Miniature circuit-breakers S 280 UC Internal resistance and power loss of miniature circuit-breakers Internal resistance per pole in m Power loss per pole in W type S 280 rated current In A MCB series S 280 UC-B m W 280 UC-K m W 280 UC-Z m W 0.2 0.3 0.5 - - - - - - 33300 19700 5020 1.33 1.77 1.26 - - 10100 - - 2.52 0.75 1 1.6 - - - - - - 2400 1390 612 1.35 1.39 1.56 - 2270 1100 - 2.27 2.81 2 3 4 - - - - - - 450 147 112 1.79 1.32 1.79 619 202 149 2.47 1.82 2.38 6 8 10 55 - 13.5 2.0 - 1.35 54.1 33.8 15.1 1.95 2.16 1.51 104 53.9 17.5 3.74 3.45 1.75 13 16 - 9.7 - 2.5 8.1 - 2.07 10.9 - 2.80 20 25 32 6.25 3.0 - 2.5 1.9 - 5.27 3.97 2.65 2.11 2.48 2.71 6.0 4.1 2.81 2.40 2.56 2.88 40 50 63 - - - - - - 2.44 1.15 0.7 3.90 2.90 5.20 2.55 1.77 1.31 4.09 4.43 5.20 - - Diagrams of let-through values I t at 230/400 V Miniature circuit-breakers S 280 K SK 0158 Z 94 SK 0157 Z 94 Miniature circuit-breakers S 280 Z 51 Miniature circuit-breakers S 280 UC Dimension drawings System pro M measurements in mm S 280 S 281 S 283 S 282 S 284 Connection drawings Supply optional from top or bottom, terminal designation acc. to EN 50 005 2 pole. 3 pole. 2CDC 092 132 F00005 1 pole SK 0118 Z 93 H 10 KL S2 - S 52 AL UA 4 pole. 2CDC 022 133 F00005 S 280 SK0109 Z 97 SK0025 Z 95 SK0017 Z 94 Miniature circuit-breakers S 280 AL UA System pro M Power miniature circuit-breakers S 280 UC for AC/DC applications If voltages to earth exceeding 220 V DC may occur, 2-pole S 280 UC is to be used for one-pole disconnection, and four-pole S 280 UC for all-pole disconnection. UC = Universal Current = AC/DC S 280 UC miniature circuit-breakers can be used in the one-pole version as 220 V --, ... 2- and in the 2-pole or 4-pole version with series connection of two poles up to 440 V -- ... . S 280 differs from the standard type as it is fitted with permanent magnets that support positive arc quenching. During the installation process, it is therefore necessary to pay due regard to the polarity and the conduction direction. DC incoming supply from above S 280 UC-... MCBs have, in the area of arcing pace outlets, permanent magnets, it is therefore necessary to take into account the polarity during the installation process. Doing so ensures that in the case of a short circuit the magnetic field of the permanent magnets corresponds with the electromagnetic field of the shortcircuit current, therefore safely leading the short circuit into the arc chute. Incorrect polarities may cause damage to the MCB. This is why - in the case of top-fed devices - terminal 1 must be fed (-) and terminal 3 (+). Example for permissible voltages between the conductors depending on the number of poles and type of connection: Voltage Un between conductors 220 V- 440 V- 440 V- 440 V- 440 V- (inverted circuit) Voltage Un between conductor and earth 220 V- 220 V- 440 V- 220 V- 220 V- 1pole S 281 UC 2pole S 282 UC 2pole S 282 UC 2pole S 282 UC 4pole S 284 UC MCB SK 0114 Z 94 Supply bottom SK 0115 Z 94 Supply top Examples for different voltage levels between conductor and earth in the case of identical voltage between conductors: Voltage Un between conductors 440 V- all-pole disconnection Voltage Un between conductor and earth 220 V- circuit symmetrically earthed 440 V- circuit asymmetrically earthed 440 V- circuit unearthed or asymmetrically earthed MCB automat 2pole S 282 UC 2pole S 282 UC 4pole S 284 UC 440 V- 440 V- all-pole disconnection SK 0196 Z 98 1pole disconnection In the circuit diagram, the negative pole is earthed. In the circuit diagram, the positive pole is earthed. 53 System pro M Miniature circuit-breakers S 280 UC Installation and operating instructions SK 0134 Z 94 Installation can be installed in any mounting position due to snap-on fixing to DIN rails EN 60 715, 35 mm width (see figures 1 and 2). SK 0134 Z 94 Abb. 1 Snap on Abb. 2 Remove Important: Installation and removal only by authorized personnel. Connection Supply optional from top or bottom. Ensure that conductors are connected correctly and firmly. Max. tightening torque 2 Nm. Operation Miniature circuit-breakers are switched on by switching the operating lever into the upper position (with respect to the text block of the nameplate). The display changes from green to red. If an MCB, after it having tripped (display green), cannot be switched on again easily, the tripping is probably due to overload. If the circuit-breaker trips again immediately when trying to reclose after a short period of time, a complete short-circuit, or as the case may be, earth connection can be assumed. Do not try and continuously re-close an existing short circuit or earth fault. The MCB trips under overload, or short-circuit or earth fault conditions, even if the operating lever is maintained in the ON position by force (trip-free mechanism). Cleaning the device MCBs soiled by installation work should be cleaned with a dry, or, if necessary, a damp and soapy cloth. Never use caustic agents or dissolvent. Maintenance STOTZ miniature circuit-breakers are maintenance-free. Opening the device will lead to a loss of warranty. 54 Miniature circuit-breakers S 200 U Special features according to UL 489, CSA 22.2 No. 5 240 V AC 277/480 V AC 55 System pro M compact(R) Miniature circuit-breakers S 200 U Special features Application notes Newly developed System pro M compact busbars UL 489. No time-consuming cutting to length. No extra end caps. Supplied ready to use in standard lengths. 2CDC 003 037 F0005 Also in combination with RCCBs corss-wiring is possible. 2CDC 003 170 F0005 Disconnector abilities according to EN 60 898-1, rated surge withstand capacity Uimp 4 kV (1.2/50); test voltage 6.2 kV at NN Can be used as main circuit breaker according to EN 60 947-3 due to positive contacts position indication for each pole red = ON, green = OFF 2CDC 003 170 F0005 SK 0045 B 99 A padlock device prevents unauthorized switching to ON or OFF. Incoming supply up to 25 mm2 without supplementary terminal Incoming supply up to 50 mm2 with supplementary terminal Dual-Terminal different cross-sections can be connected 2CDC 023 228 F0005 56 System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U series acc. to UL 489, CSA 22.2 No. 5 S 200 U-K 240 V AC Selection table K No. of poles 1 2CDC 021 314 F0004 10 000 2CDC 021 315 F0004 2 Type No. Order code bbn 40 16779 EAN 0.2 0.3 0.5 S 201 U-K 0.2 S 201 U-K 0.3 S 201 U-K 0.5 2CDS 271 417 R0087 2CDS 271 417 R0117 2CDS 271 417 R0157 61922 6 61923 3 61924 0 0.14 0.14 0.14 10 10 10 0.75 1 1.6 S 201 U-K 0.75 S 201 U-K 1 S 201 U-K 1.6 2CDS 271 417 R0187 2CDS 271 417 R0217 2CDS 271 417 R0257 61925 7 61926 4 61927 1 0.14 0.14 0.14 10 10 10 2 3 4 S 201 U-K 2 S 201 U-K 3 S 201 U-K 4 2CDS 271 417 R0277 2CDS 271 417 R0317 2CDS 271 417 R0337 61928 8 61929 5 61930 1 0.14 0.14 0.14 10 10 10 5 6 8 S 201 U-K 5 S 201 U-K 6 S 201 U-K 8 2CDS 271 417 R0357 2CDS 271 417 R0377 2CDS 271 417 R0407 61931 8 61932 5 61933 2 0.14 0.14 0.14 10 10 10 10 15 16 S 201 U-K 10 S 201 U-K 15 S 201 U-K 16 2CDS 271 417 R0427 2CDS 271 417 R0457 2CDS 271 417 R0467 61934 9 61936 3 61937 0 0.14 0.14 0.14 10 10 10 20 25 30 S 201 U-K 20 S 201 U-K 25 S 201 U-K 30 2CDS 271 417 R0487 2CDS 271 417 R0517 2CDS 271 417 R0527 61938 7 61939 4 61940 0 0.14 0.14 0.14 10 10 10 32 40 50 S 201 U-K 32 S 201 U-K 40 S 201 U-K 50 2CDS 271 417 R0537 2CDS 271 417 R0557 2CDS 271 417 R0577 61941 7 61942 4 61943 1 0.14 0.14 0.14 10 10 10 60 63 S 201 U-K 60 S 201 U-K 63 2CDS 271 417 R0587 2CDS 271 417 R0607 61944 8 61945 5 0.14 0.14 10 10 0.2 0.3 0.5 S 202 U-K 0.2 S 202 U-K 0.3 S 202 U-K 0.5 2CDS 272 417 R0087 2CDS 272 417 R0117 2CDS 272 417 R0157 61946 2 61947 9 61948 6 0.28 0.28 0.28 5 5 5 0.75 1 1.6 S 202 U-K 0.75 S 202 U-K 1 S 202 U-K 1.6 2CDS 272 417 R0187 2CDS 272 417 R0217 2CDS 272 417 R0257 61949 3 61950 9 61951 6 0.28 0.28 0.28 5 5 5 2 3 4 S 202 U-K 2 S 202 U-K 3 S 202 U-K 4 2CDS 272 417 R0277 2CDS 272 417 R0317 2CDS 272 417 R0337 61952 3 61953 0 61954 7 0.28 0.28 0.28 5 5 5 5 6 8 S 202 U-K 5 S 202 U-K 6 S 202 U-K 8 2CDS 272 417 R0357 2CDS 272 417 R0377 2CDS 272 417 R0407 61955 4 61956 1 61957 8 0.28 0.28 0.28 5 5 5 10 15 16 S 202 U-K 10 S 202 U-K 15 S 202 U-K 16 2CDS 272 417 R0427 2CDS 272 417 R0457 2CDS 272 417 R0467 61958 5 61960 8 61961 5 0.28 0.28 0.28 5 5 5 20 25 30 S 202 U-K 20 S 202 U-K 25 S 202 U-K 30 2CDS 272 417 R0487 2CDS 272 417 R0517 2CDS 272 417 R0527 61962 2 61963 9 61964 6 0.28 0.28 0.28 5 5 5 32 40 50 S 202 U-K 32 S 202 U-K 40 S 202 U-K 50 2CDS 272 417 R0537 2CDS 272 417 R0557 2CDS 272 417 R0577 61965 3 61966 0 61967 7 0.28 0.28 0.28 5 5 5 60 63 S 202 U-K 60 S 202 U-K 63 2CDS 272 417 R0587 2CDS 272 417 R0607 61968 4 61969 1 0.28 0.28 5 5 Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit kg piece 57 System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U series acc. to UL 489, CSA 22.2 No. 5 S 200 U-K 240 V AC Selection table K No. of poles 3 2CDC 021 316 F0004 10 000 2CDC 021 317 F0004 4 58 Type No. Order code bbn 40 16779 EAN 0.2 0.3 0.5 S 203 U-K 0.2 S 203 U-K 0.3 S 203 U-K 0.5 2CDS 273 417 R0087 2CDS 273 417 R0117 2CDS 273 417 R0157 61970 7 61971 4 61972 1 0.42 0.42 0.42 3 3 3 0.75 1 1.6 S 203 U-K 0.75 S 203 U-K 1 S 203 U-K 1.6 2CDS 273 417 R0187 2CDS 273 417 R0217 2CDS 273 417 R0257 61973 8 61974 5 61975 2 0.42 0.42 0.42 3 3 3 2 3 4 S 203 U-K 2 S 203 U-K 3 S 203 U-K 4 2CDS 273 417 R0277 2CDS 273 417 R0317 2CDS 273 417 R0337 61976 9 61977 6 61978 3 0.42 0.42 0.42 3 3 3 5 6 8 S 203 U-K 5 S 203 U-K 6 S 203 U-K 8 2CDS 273 417 R0357 2CDS 273 417 R0377 2CDS 273 417 R0407 61979 0 61980 6 61981 3 0.42 0.42 0.42 3 3 3 10 15 16 S 203 U-K 10 S 203 U-K 15 S 203 U-K 16 2CDS 273 417 R0427 2CDS 273 417 R0457 2CDS 273 417 R0467 61982 0 61984 4 61985 1 0.42 0.42 0.42 3 3 3 20 25 30 S 203 U-K 20 S 203 U-K 25 S 203 U-K 30 2CDS 273 417 R0487 2CDS 273 417 R0517 2CDS 273 417 R0527 61986 8 61987 5 61988 2 0.42 0.42 0.42 3 3 3 32 40 50 S 203 U-K 32 S 203 U-K 40 S 203 U-K 50 2CDS 273 417 R0537 2CDS 273 417 R0557 2CDS 273 417 R0577 61989 9 61990 5 61991 2 0.42 0.42 0.42 3 3 3 60 63 S 203 U-K 60 S 203 U-K 63 2CDS 273 417 R0587 2CDS 273 417 R0607 61992 9 61993 6 0.42 0.42 3 3 0.2 0.3 0.5 S 204 U-K 0.2 S 204 U-K 0.3 S 204 U-K 0.5 2CDS 274 417 R0087 2CDS 274 417 R0117 2CDS 274 417 R0157 61994 3 61995 0 61996 7 0.56 0.56 0.56 2 2 2 0.75 1 1.6 S 204 U-K 0.75 S 204 U-K 1 S 204 U-K 1.6 2CDS 274 417 R0187 2CDS 274 417 R0217 2CDS 274 417 R0257 61997 4 61998 1 61999 8 0.56 0.56 0.56 2 2 2 2 3 4 S 204 U-K 2 S 204 U-K 3 S 204 U-K 4 2CDS 274 417 R0277 2CDS 274 417 R0317 2CDS 274 417 R0337 62000 0 62001 7 62002 4 0.56 0.56 0.56 2 2 2 5 6 8 S 204 U-K 5 S 204 U-K 6 S 204 U-K 8 2CDS 274 417 R0357 2CDS 274 417 R0377 2CDS 274 417 R0407 62003 1 62004 8 62005 5 0.56 0.56 0.56 2 2 2 10 15 16 S 204 U-K 10 S 204 U-K 15 S 204 U-K 16 2CDS 274 417 R0427 2CDS 274 417 R0457 2CDS 274 417 R0467 62006 2 62008 6 62009 3 0.56 0.56 0.56 2 2 2 20 25 30 S 204 U-K 20 S 204 U-K 25 S 204 U-K 30 2CDS 274 417 R0487 2CDS 274 417 R0517 2CDS 274 417 R0527 62010 9 62011 6 62012 3 0.56 0.56 0.56 2 2 2 32 40 50 S 204 U-K 32 S 204 U-K 40 S 204 U-K 50 2CDS 274 417 R0537 2CDS 274 417 R0557 2CDS 274 417 R0577 62013 0 62014 7 62015 4 0.56 0.56 0.56 2 2 2 60 63 S 204 U-K 60 S 204 U-K 63 2CDS 274 417 R0587 2CDS 274 417 R0607 62016 1 62017 8 0.56 0.56 2 2 Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit kg piece System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U series acc. to UL 489, CSA 22.2 No. 5 S 200 U-Z 240 V AC Selection table Z No. of poles 1 2CDC 021 314 F0004 10 000 2CDC 021 315 F0004 2 Type No. Order code bbn 40 16779 EAN 0.5 1 1.6 S 201 U-Z 0.5 S 201 U-Z 1 S 201 U-Z 1.6 2CDS 271 417 R0158 2CDS 271 417 R0218 2CDS 271 417 R0258 620185 620192 620208 0.14 0.14 0.14 10 10 10 2 3 4 S 201 U-Z 2 S 201 U-Z 3 S 201 U-Z 4 2CDS 271 417 R0278 2CDS 271 417 R0318 2CDS 271 417 R0338 620215 620222 620239 0.14 0.14 0.14 10 10 10 5 6 8 S 201 U-Z 5 S 201 U-Z 6 S 201 U-Z 8 2CDS 271 417 R0358 2CDS 271 417 R0378 2CDS 271 417 R0408 620246 620253 620260 0.14 0.14 0.14 10 10 10 10 15 16 S 201 U-Z 10 S 201 U-Z 15 S 201 U-Z 16 2CDS 271 417 R0428 2CDS 271 417 R0458 2CDS 271 417 R0468 620277 620291 620307 0.14 0.14 0.14 10 10 10 20 25 30 S 201 U-Z 20 S 201 U-Z 25 S 201 U-Z 30 2CDS 271 417 R0488 2CDS 271 417 R0518 2CDS 271 417 R0528 620314 620321 622851 0.14 0.14 0.14 10 10 10 32 40 50 S 201 U-Z 32 S 201 U-Z 40 S 201 U-Z 50 2CDS 271 417 R0538 2CDS 271 417 R0558 2CDS 271 417 R0578 620345 620352 620369 0.14 0.14 0.14 10 10 10 60 63 S 201 U-Z 60 S 201 U-Z 63 2CDS 271 417 R0588 2CDS 271 417 R0608 620376 620383 0.14 0.14 10 10 0.5 1 1.6 S 202 U-Z 0.5 S 202 U-Z 1 S 202 U-Z 1.6 2CDS 272 417 R0158 2CDS 272 417 R0218 2CDS 272 417 R0258 620390 620406 620413 0.28 0.28 0.28 5 5 5 2 3 4 S 202 U-Z 2 S 202 U-Z 3 S 202 U-Z 4 2CDS 272 417 R0278 2CDS 272 417 R0318 2CDS 272 417 R0338 620420 620437 620444 0.28 0.28 0.28 5 5 5 5 6 8 S 202 U-Z 5 S 202 U-Z 6 S 202 U-Z 8 2CDS 272 417 R0358 2CDS 272 417 R0378 2CDS 272 417 R0408 620451 620468 620475 0.28 0.28 0.28 5 5 5 10 15 16 S 202 U-Z 10 S 202 U-Z 15 S 202 U-Z 16 2CDS 272 417 R0428 2CDS 272 417 R0458 2CDS 272 417 R0468 620482 620505 620512 0.28 0.28 0.28 5 5 5 20 25 30 S 202 U-Z 20 S 202 U-Z 25 S 202 U-Z 30 2CDS 272 417 R0488 2CDS 272 417 R0518 2CDS 272 417 R0528 620529 620536 620543 0.28 0.28 0.28 5 5 5 32 40 50 S 202 U-Z 32 S 202 U-Z 40 S 202 U-Z 50 2CDS 272 417 R0538 2CDS 272 417 R0558 2CDS 272 417 R0578 620550 620567 620574 0.28 0.28 0.28 5 5 5 60 63 S 202 U-Z 60 S 202 U-Z 63 2CDS 272 417 R0588 2CDS 272 417 R0608 620581 620598 0.28 0.28 5 5 Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit kg piece 59 System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U series acc. to UL 489, CSA 22.2 No. 5 S 200 U-Z 240 V AC Selection table Z No. of poles Order code 0.5 1 1.6 S 203 U-Z 0.5 S 203 U-Z 1 S 203 U-Z 1.6 2CDS 273 417 R0158 2CDS 273 417 R0218 2CDS 273 417 R0258 620604 620611 620628 0.42 0.42 0.42 3 3 3 2 3 4 S 203 U-Z 2 S 203 U-Z 3 S 203 U-Z 4 2CDS 273 417 R0278 2CDS 273 417 R0318 2CDS 273 417 R0338 620635 620642 620659 0.42 0.42 0.42 3 3 3 5 6 8 S 203 U-Z 5 S 203 U-Z 6 S 203 U-Z 8 2CDS 273 417 R0358 2CDS 273 417 R0378 2CDS 273 417 R0408 620666 620673 620680 0.42 0.42 0.42 3 3 3 10 15 16 S 203 U-Z 10 S 203 U-Z 15 S 203 U-Z 16 2CDS 273 417 R0428 2CDS 273 417 R0458 2CDS 273 417 R0468 620697 620710 620727 0.42 0.42 0.42 3 3 3 20 25 30 S 203 U-Z 20 S 203 U-Z 25 S 203 U-Z 30 2CDS 273 417 R0488 2CDS 273 417 R0518 2CDS 273 417 R0528 620734 620741 620758 0.42 0.42 0.42 3 3 3 32 40 50 S 203 U-Z 32 S 203 U-Z 40 S 203 U-Z 50 2CDS 273 417 R0538 2CDS 273 417 R0558 2CDS 273 417 R0578 620765 620772 620789 0.42 0.42 0.42 3 3 3 60 63 S 203 U-Z 60 S 203 U-Z 63 2CDS 273 417 R0588 2CDS 273 417 R0608 620796 620802 0.42 0.42 3 3 0.5 1 1.6 S 204 U-Z 0.5 S 204 U-Z 1 S 204 U-Z 1.6 2CDS 274 417 R0158 2CDS 274 417 R0218 2CDS 274 417 R0258 620819 620826 620833 0.56 0.56 0.56 2 2 2 2 3 4 S 204 U-Z 2 S 204 U-Z 3 S 204 U-Z 4 2CDS 274 417 R0278 2CDS 274 417 R0318 2CDS 274 417 R0338 620840 620857 620864 0.56 0.56 0.56 2 2 2 5 6 8 S 204 U-Z 5 S 204 U-Z 6 S 204 U-Z 8 2CDS 274 417 R0358 2CDS 274 417 R0378 2CDS 274 417 R0408 620871 620888 620895 0.56 0.56 0.56 2 2 2 10 15 16 S 204 U-Z 10 S 204 U-Z 15 S 204 U-Z 16 2CDS 274 417 R0428 2CDS 274 417 R0458 2CDS 274 417 R0468 620901 620925 620932 0.56 0.56 0.56 2 2 2 20 25 30 S 204 U-Z 20 S 204 U-Z 25 S 204 U-Z 30 2CDS 274 417 R0488 2CDS 274 417 R0518 2CDS 274 417 R0528 620949 620956 620963 0.56 0.56 0.56 2 2 2 32 40 50 S 204 U-Z 32 S 204 U-Z 40 S 204 U-Z 50 2CDS 274 417 R0538 2CDS 274 417 R0558 2CDS 274 417 R0578 620970 620987 620994 0.56 0.56 0.56 2 2 2 60 63 S 204 U-Z 60 S 204 U-Z 63 2CDS 274 417 R0588 2CDS 274 417 R0608 621007 621014 0.56 0.56 2 2 3 2CDC 021 316 F0004 10 000 2CDC 021 317 F0004 4 60 Type No. bbn 40 16779 EAN Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit kg piece System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 UP series acc. to UL 489, CSA 22.2 No. 5 S 200 UP-K 480Y / 277 V AC Selection table K No. of poles 1 2CDC 021 318 F0004 10 000 2CDC 021 319 F0004 2 2CDC 021 320 F0004 3 2CDC 023 321 F0004 4 Type No. Order code bbn 40 16779 EAN 0.2 0.3 0.5 S 201 UP-K 0.2 S 201 UP-K 0.3 S 201 UP-K 0.5 2CDS 271 317 R0087 2CDS 271 317 R0117 2CDS 271 317 R0157 61563 1 61564 8 61565 5 0.14 0.14 0.14 10 10 10 0.75 1 1.6 S 201 UP-K 0.75 S 201 UP-K 1 S 201 UP-K 1.6 2CDS 271 317 R0187 2CDS 271 317 R0217 2CDS 271 317 R0257 61566 2 61567 9 61568 6 0.14 0.14 0.14 10 10 10 2 3 4 S 201 UP-K 2 S 201 UP-K 3 S 201 UP-K 4 2CDS 271 317 R0277 2CDS 271 317 R0317 2CDS 271 317 R0337 61569 3 61570 9 61571 6 0.14 0.14 0.14 10 10 10 5 6 8 S 201 UP-K 5 S 201 UP-K 6 S 201 UP-K 8 2CDS 271 317 R0357 2CDS 271 317 R0377 2CDS 271 317 R0407 61572 3 61573 0 61574 7 0.14 0.14 0.14 10 10 10 10 15 16 S 201 UP-K 10 S 201 UP-K 15 S 201 UP-K 16 2CDS 271 317 R0427 2CDS 271 317 R0457 2CDS 271 317 R0467 61575 4 61577 8 61578 5 0.14 0.14 0.14 10 10 10 20 25 S 201 UP-K 20 S 201 UP-K 25 2CDS 271 317 R0487 2CDS 271 317 R0517 61579 2 61580 8 0.14 0.14 10 10 0.2 0.3 0.5 S 202 UP-K 0.2 S 202 UP-K 0.3 S 202 UP-K 0.5 2CDS 272 317 R0087 2CDS 272 317 R0117 2CDS 272 317 R0157 61587 7 61588 4 61589 1 0.28 0.28 0.28 5 5 5 0.75 1 1.6 S 202 UP-K 0.75 S 202 UP-K 1 S 202 UP-K 1.6 2CDS 272 317 R0187 2CDS 272 317 R0217 2CDS 272 317 R0257 61590 7 61591 4 61592 1 0.28 0.28 0.28 5 5 5 2 3 4 S 202 UP-K 2 S 202 UP-K 3 S 202 UP-K 4 2CDS 272 317 R0277 2CDS 272 317 R0317 2CDS 272 317 R0337 61593 8 61594 5 61595 2 0.28 0.28 0.28 5 5 5 5 6 8 S 202 UP-K 5 S 202 UP-K 6 S 202 UP-K 8 2CDS 272 317 R0357 2CDS 272 317 R0377 2CDS 272 317 R0407 61596 9 61597 6 61598 3 0.28 0.28 0.28 5 5 5 10 15 16 S 202 UP-K 10 S 202 UP-K 15 S 202 UP-K 16 2CDS 272 317 R0427 2CDS 272 317 R0457 2CDS 272 317 R0467 61599 0 61601 0 61602 7 0.28 0.28 0.28 5 5 5 20 25 S 202 UP-K 20 S 202 UP-K 25 2CDS 272 317 R0487 2CDS 272 317 R0517 61603 4 61604 1 0.28 0.28 5 5 0.2 0.3 0.5 S 203 UP-K 0.2 S 203 UP-K 0.3 S 203 UP-K 0.5 2CDS 273 317 R0087 2CDS 273 317 R0117 2CDS 273 317 R0157 61611 9 61612 6 61613 3 0.42 0.42 0.42 3 3 3 0.75 1 1.6 S 203 UP-K 0.75 S 203 UP-K 1 S 203 UP-K 1.6 2CDS 273 317 R0187 2CDS 273 317 R0217 2CDS 273 317 R0257 61614 0 61615 7 61616 4 0.42 0.42 0.42 3 3 3 2 3 4 S 203 UP-K 2 S 203 UP-K 3 S 203 UP-K 4 2CDS 273 317 R0277 2CDS 273 317 R0317 2CDS 273 317 R0337 61617 1 61618 8 61619 5 0.42 0.42 0.42 3 3 3 5 6 8 S 203 UP-K 5 S 203 UP-K 6 S 203 UP-K 8 2CDS 273 317 R0357 2CDS 273 317 R0377 2CDS 273 317 R0407 61620 1 61621 8 61622 5 0.42 0.42 0.42 3 3 3 10 15 16 S 203 UP-K 10 S 203 UP-K 15 S 203 UP-K 16 2CDS 273 317 R0427 2CDS 273 317 R0457 2CDS 273 317 R0467 61623 2 61625 6 61626 3 0.42 0.42 0.42 3 3 3 20 25 S 203 UP-K 20 S 203 UP-K 25 2CDS 273 317 R0487 2CDS 273 317 R0517 61627 0 61628 7 0.42 0.42 3 3 0.2 0.3 0.5 S 204 UP-K 0.2 S 204 UP-K 0.3 S 204 UP-K 0.5 2CDS 274 317 R0087 2CDS 274 317 R0117 2CDS 274 317 R0157 61635 5 61636 2 61637 9 0.56 0.56 0.56 2 2 2 0.75 1 1.6 S 204 UP-K 0.75 S 204 UP-K 1 S 204 UP-K 1.6 2CDS 274 317 R0187 2CDS 274 317 R0217 2CDS 274 317 R0257 61638 6 61639 3 61640 9 0.56 0.56 0.56 2 2 2 2 3 4 S 204 UP-K 2 S 204 UP-K 3 S 204 UP-K 4 2CDS 274 317 R0277 2CDS 274 317 R0317 2CDS 274 317 R0337 61641 6 61642 3 61643 0 0.56 0.56 0.56 2 2 2 5 6 8 S 204 UP-K 5 S 204 UP-K 6 S 204 UP-K 8 2CDS 274 317 R0357 2CDS 274 317 R0377 2CDS 274 317 R0407 61644 7 61645 4 61646 1 0.56 0.56 0.56 2 2 2 10 15 16 S 204 UP-K 10 S 204 UP-K 15 S 204 UP-K 16 2CDS 274 317 R0427 2CDS 274 317 R0457 2CDS 274 317 R0467 61647 8 61649 2 61650 8 0.56 0.56 0.56 2 2 2 20 25 S 204 UP-K 20 S 204 UP-K 25 2CDS 274 317 R0487 2CDS 274 317 R0517 61651 5 61652 2 0.56 0.56 2 2 Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit kg piece 61 System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 UP series acc. to UL 489, CSA 22.2 No. 5 S 200 UP-Z 480Y / 277 V AC Selection table Z No. of poles 1 2CDC 021 318 F0004 10 000 2CDC 021 319 F0004 2 2CDC 021 320 F0004 3 2CDC 021 321 F0004 4 62 Type No. Order code bbn 40 16779 EAN 0.5 1 1.6 S 201 UP-Z 0.5 S 201 UP-Z 1 S 201 UP-Z 1.6 2CDS 271 317 R0158 2CDS 271 317 R0218 2CDS 271 317 R0258 61659 1 61660 7 61661 4 0.14 0.14 0.14 10 10 10 2 3 4 S 201 UP-Z 2 S 201 UP-Z 3 S 201 UP-Z 4 2CDS 271 317 R0278 2CDS 271 317 R0318 2CDS 271 317 R0338 61662 1 61663 8 61664 5 0.14 0.14 0.14 10 10 10 5 6 8 S 201 UP-Z 5 S 201 UP-Z 6 S 201 UP-Z 8 2CDS 271 317 R0358 2CDS 271 317 R0378 2CDS 271 317 R0408 61665 2 61666 9 61667 6 0.14 0.14 0.14 10 10 10 10 15 16 S 201 UP-Z 10 S 201 UP-Z 15 S 201 UP-Z 16 2CDS 271 317 R0428 2CDS 271 317 R0458 2CDS 271 317 R0468 61668 3 61670 6 61671 3 0.14 0.14 0.14 10 10 10 20 25 S 201 UP-Z 20 S 201 UP-Z 25 2CDS 271 317 R0488 2CDS 271 317 R0518 61672 0 61673 7 0.14 0.14 10 10 0.5 1 1.6 S 202 UP-Z 0.5 S 202 UP-Z 1 S 202 UP-Z 1.6 2CDS 272 317 R0158 2CDS 272 317 R0218 2CDS 272 317 R0258 61680 5 61681 2 61682 9 0.28 0.28 0.28 5 5 5 2 3 4 S 202 UP-Z 2 S 202 UP-Z 3 S 202 UP-Z 4 2CDS 272 317 R0278 2CDS 272 317 R0318 2CDS 272 317 R0338 61683 6 61684 3 61685 0 0.28 0.28 0.28 5 5 5 5 6 8 S 202 UP-Z 5 S 202 UP-Z 6 S 202 UP-Z 8 2CDS 272 317 R0358 2CDS 272 317 R0378 2CDS 272 317 R0408 61686 7 61687 4 61688 1 0.28 0.28 0.28 5 5 5 10 15 16 S 202 UP-Z 10 S 202 UP-Z 15 S 202 UP-Z 16 2CDS 272 317 R0428 2CDS 272 317 R0458 2CDS 272 317 R0468 61689 8 61691 1 61692 8 0.28 0.28 0.28 5 5 5 20 25 S 202 UP-Z 20 S 202 UP-Z 25 2CDS 272 317 R0488 2CDS 272 317 R0518 61693 5 61694 2 0.28 0.28 5 5 0.5 1 1.6 S 203 UP-Z 0.5 S 203 UP-Z 1 S 203 UP-Z 1.6 2CDS 273 317 R0158 2CDS 273 317 R0218 2CDS 273 317 R0258 61701 7 61702 4 61703 1 0.42 0.42 0.42 3 3 3 2 3 4 S 203 UP-Z 2 S 203 UP-Z 3 S 203 UP-Z 4 2CDS 273 317 R0278 2CDS 273 317 R0318 2CDS 273 317 R0338 61704 8 61705 5 61706 2 0.42 0.42 0.42 3 3 3 5 6 8 S 203 UP-Z 5 S 203 UP-Z 6 S 203 UP-Z 8 2CDS 273 317 R0358 2CDS 273 317 R0378 2CDS 273 317 R0408 61707 9 61708 6 61709 3 0.42 0.42 0.42 3 3 3 10 15 16 S 203 UP-Z 10 S 203 UP-Z 15 S 203 UP-Z 16 2CDS 273 317 R0428 2CDS 273 317 R0458 2CDS 273 317 R0468 61710 9 61712 3 61713 0 0.42 0.42 0.42 3 3 3 20 25 S 203 UP-Z 20 S 203 UP-Z 25 2CDS 273 317 R0488 2CDS 273 317 R0518 61714 7 61715 4 0.42 0.42 3 3 0.5 1 1.6 S 204 UP-Z 0.5 S 204 UP-Z 1 S 204 UP-Z 1.6 2CDS 274 317 R0158 2CDS 274 317 R0218 2CDS 274 317 R0258 61722 2 61723 9 61724 6 0.56 0.56 0.56 2 2 2 2 3 4 S 204 UP-Z 2 S 204 UP-Z 3 S 204 UP-Z 4 2CDS 274 317 R0278 2CDS 274 317 R0318 2CDS 274 317 R0338 61725 3 61726 0 61727 7 0.56 0.56 0.56 2 2 2 5 6 8 S 204 UP-Z 5 S 204 UP-Z 6 S 204 UP-Z 8 2CDS 274 317 R0358 2CDS 274 317 R0378 2CDS 274 317 R0408 61728 4 61729 1 61730 7 0.56 0.56 0.56 2 2 2 10 15 16 S 204 UP-Z 10 S 204 UP-Z 15 S 204 UP-Z 16 2CDS 274 317 R0428 2CDS 274 317 R0458 2CDS 274 317 R0468 61731 4 61733 8 61734 5 0.56 0.56 0.56 2 2 2 20 25 S 204 UP-Z 20 S 204 UP-Z 25 2CDS 274 317 R0488 2CDS 274 317 R0518 61735 2 61736 9 0.56 0.56 2 2 Rated current In A Ordering details Price Price Weight Pack. 1 piece group 1 piece unit kg piece System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U and S 200 UP series acc. to UL 489, CSA 22.2 No. 5 Accessories for S 200 U / S 200 UP 2CDC 021 322 F0004 Description Order details Type code Order code bbn 40 16779 EAN S2C-H6RU 2CDS 200 914 R0001 61561 7 0.035 1 S2C-S6RU 2CDS 200 924 R0001 64677 2 0.035 1 S2C-A1U 2CDS 200 908 R0001 64472 3 S2C-A2U 2CDS 200 908 R0002 64473 0 Price Price Weight Pack. 1 piece group 1 piece unit kg pcs. Auxiliary contact Auxiliary contact only for U/UP series Signal contact Signal contact only for U/UP series Shunt trip S2C-H6 RU 12...60 V AC/DC 110...415 V AC 2CDC 021 324 F0004 110...250 V DC Connection drawings Signal contact S2C-S6 RU S2C-S6 RU Auxiliary contact SK 0240 Z 02 2CDC 092 047 F0005 Auxiliary contact in ON position in OFF position after tripping 2CDC 092 048 F0005 Auxiliary contact in OFF position Miniature circuit breaker Feeder optional, top or bottom. Terminal designation acc. to EN 50 005. Shunt trip S2C-A1 U S2C-A2 U 2CDC 092 046 F0005 S2C-A1 U 2CDC 022 049 F0005 SK 0242 Z 02 2CDC 021 146 F0005 in ON and OFF position after hand operation 63 System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U and S 200 UP series acc. to UL 489, CSA 22.2 No. 5 Technical data S 200 U Specifications: UL File-Number: No. of poles: tripping characteristics: rated current In: rated voltage Un: UL 489, CSA 22.2 No.5, IEC 60 947-2 E 2123233 1, 2, 3 und 4 K and Z 0.2 (K) 0.5 (Z) ... 63 A 1-pole: 240 V AC multipole: 240 V AC 10 kA 50/60 Hz IP 20 optional 35 mm DIN rail 18 ... 4 AWG (0.75 ... 25 mm2) short circuit rupturing capacity: frequency: degree of protection: mounting position: fixing: clamps only for Co: service life, mech. and at rated load: tightening torque: reference temperature: ambient temperature: shock resistance: resistance to vibration acc. to IEC 60 068-2-6 S 200 UP 0.2 (K) 0.5 (Z) ... 25 A 1-pole: 277 V AC multipole: 480 Y/277 V AC 20.000 operations 25 in. lbs (2.8 Nm) 25 C - 25 ... + 55 C 10 g at least 2 impacts shock duration 13 ms 5 g, 20 frequency cycles, 5 ... 150 ... 5 Hz bei 0.8 In These two equipment rows are calling oneself different rated current range, the rated voltage and the equipment measurement through hers. Auxiliary contact S2C-H6RU and Signal contact S2C-S6RU for Miniature Moulded Case Circuit Breakers S 200 U and S 200 UP rated current In: rated voltage AC / DC: short-circuit withstand capacity / 230 V AC: insulation coordination: - overvoltage category: - surge voltage: - pollution degtree: contact: connection capacity mm2 tightening torque: shock resistance acc. to DIN IEC 68-2-6: 10 24 1000 A bei S 201 K4 acc. to DIN VDE 0110 part 1 and 2 III 4 kV (1.2/50 s) 2 1 change over 0.75...2.5 1.2 Nm 5 g, 20 frequency cycles 5...150...5 Hz at 24 V AC/DC, 5 mA auto-reclosing < 10 ms 10.000 operations 68 x 74 x 99 mm mechanical service life : dimensions: AC 14 Ue Ie 400V 1A 230 V 2A Shunt trip DC 12 Ue Ie 220 V 1A 110 V 1.5 A DC Ue Ie 60 V 2A Type S 2C-A1 U S 2C-A2 U Coil resistance Terminals Tightening torque Dimensions (H x D x W) V V ms V V VA VA mm2 Nm mm 12 ... 60 12 ... 60 < 10 7 10 40 ... 200 40 ... 200 3.7 16 2 100 x 69 x 17.5 110 ... 415 110 ... 250 < 10 55 80 55 ... 210 55 ... 110 225 16 2 100 x 69 x 17.5 Undervoltage release Type Rated voltage Max. release duration Min. release voltage Consumption on release Standards Rated voltage Frequency Release trip Terminals Consumption R esistance to corrosion Protection degree Tightening torque Dimensions (H x D x W) 64 AC DC AC DC AC DC AC DC V V Hz V mm2 VA C/RH Nm mm S 2C-UA 12 DC 12 0.2 S 2C-UA 24 AC S 2C-UA 24 DC S 2C-UA 48 AC S 2C-UA S 2C-UA S 2C-UA S 2C-UA S 2C-UA 48 DC 110 AC 110 DC 230 AC 230 DC IEC/EN 60947-1 24 48 110 230 24 48 110 230 50 ... 60 0.35 UnOVO 0.7 Un 2 x 1.5 3.6 2 3.6 2.1 3.5 2.2 3.7 2.3 constant atmosphere: 23/83 - 40/93 - 55/20; variable atmosphere: 25/95 - 40/93 IPXXB / IP2X 0.4 85 x 69 x 17.5 24 V 4A S 2C-UA 400 AC 400 2.4 System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U and S 200 UP series acc. to UL 489, CSA 22.2 No. 5 Short circuit rupturing capacity series alternating current trip characteristic rated current 1phase 120 V AC 240 V AC kA/cos kA/cos A S 200 U-K, Z S 200 UP-K, Z 0.2/0.5 ... 2 3 4, 5 6 8 10 ... 20 25, 30 32 ... 63 0.2/0.5 ... 2 3 4, 5 6 8 10 ... 20 25 2/3phase 240 V AC 120/240 V AC kA/cos Back-up max. 400 V 277/480 V AC kA/cos unlimited 10/0.25 10/0.25 10/0.25 unlimited 10/0.25 10/0.25 10/0.25 10/0.25 Fuse gG/gL not required 25 A 35 A 63 A 80 A 100 A 125 A 160 A not required 25 A 35 A 63 A 80 A 100 A 125 A Back-up protection is necessary only if the solid short-circuit current to be expected at the place of installation may exceed the switching capacity indicated. S 200 U built-on of a S2C-H6RU built-on of a S2C-A..U 2CDC 022 578 F0004 S2C-A..U 2CDC 092 050 F0005 2CDC 092 045 F0005 S2C-H6RU, S2C-S6RU 2CDC 022 289 F0004 built-on of a S2C-S6RU 2CDC 022 218 F0004 S 200 UP 2CDC 022 290 F0004 Mounting 2CDC 022 291 F0004 Dimension drawings in mm 65 System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U and S 200 UP series acc. to UL 489, CSA 22.2 No. 5 Internal resistance and power loss of the Miniature Moulded Case Circuit Breakers Internal resistance per pole in m, power loss per pole in W Type S 200 U S 200 UP device series K W m m W 0.2 0.3 0.5 42500 20000 6340 1.7 1.8 1.6 - - 10100 - - 2.5 0.75 1 1.6 2500 1400 625 1.4 1.4 1.6 - 2270 1100 - 2.3 2.8 2 3 4 460 211 163 1.8 1.9 2.6 619 211 163 2.5 1.9 2.6 6 8 10 67 45 19 2.4 2.9 1.9 104 55 21 3.7 3.5 2.1 rated current In A Z 13 16 20 - 8.2 7.3 - 2.1 2.9 - 10.9 7.3 - 2.8 2.9 25 32 40 5.6 4.1 4.0 3.5 4.2 6.4 5.6 4.1 4.0 3.5 4.2 6.4 50 63 1.2 1.3 3.0 5.2 1.8 1.3 4.4 5.2 Diagrams of let through values I2 t at 230/400 V AC 66 SK 0179 Z 95 Z SK 0157 Z 94 K System pro M compact(R) Miniature Moulded Case Circuit Breakers S 200 U and S 200 UP series acc. to UL 489, CSA 22.2 No. 5 Tripping characteristic Z reference temperature 20 C The tripping device changes at a divergent ambient temperature by 6 % je 10 C reference temperature 20 C The tripping device changes at a divergent ambient temperature by 6 % je 10 C 2CDC 022 194 F0205 2CDC 022 196 F0205 Tripping characteristic K Max. operating current values depending on the ambient temperature for a cicruit-breaker in load circuit of characteristics type K and Z K and Z In (A) Ambient temperature T (C/F) - 40 - 30 - 20 - 10 0 10 20 30 40 50 60 70 0.5 0.66 0.64 0.61 0.59 0.56 0.53 0.50 0.47 0.43 0.40 0.35 0.31 1.0 1.32 1.27 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 1.6 2.12 2.04 1.96 1.88 1.79 1.70 1.60 1.50 1.39 1.26 1.13 0.98 2.0 2.65 2.55 2.45 2.35 2.24 2.12 2.00 1.87 1.73 1.58 1.41 1.22 3.0 4.0 3.8 3.7 3.5 3.4 3.2 3.0 2.8 2.6 2.4 2.1 1.8 4.0 5.3 5.1 4.9 4.7 4.5 4.2 4.0 3.7 3.5 3.2 2.8 2.4 6.0 7.9 7.6 7.3 7.0 6.7 6.4 6.0 5.6 5.2 4.7 4.2 3.7 8.0 10.8 10.2 9.8 9.4 8.9 8.5 8.0 7.5 6.9 6.3 5.7 4.9 10.0 13.2 12.7 12.2 11.7 11.2 10.6 10.0 9.4 8.7 7.9 7.1 6.1 13.0 17.2 16.6 15.9 15.2 14.5 13.8 13.0 12.2 11.3 10.3 9.2 8.0 16.0 21.2 20.4 19.6 18.8 17.9 17.0 16.0 15.0 13.9 12.6 11.3 9.8 20.0 26.5 25.5 24.5 23.5 22.4 21.2 20.0 18.7 17.3 15.8 14.1 12.2 25.0 33.1 31.9 30.6 29.3 28.0 26.5 25.0 23.4 21.7 19.8 17.7 15.3 32.0 42.3 40.8 39.2 37.5 35.8 33.9 32.0 29.9 27.7 25.3 22.6 19.6 40.0 52.9 51.0 49.0 46.9 44.7 42.4 40.0 37.4 34.6 31.6 28.3 24.5 50.0 66.1 63.7 61.2 58.6 55.9 53.0 50.0 46.8 43.3 39.5 35.4 30.6 63.0 83.3 80.3 77.2 73.9 70.4 66.8 63.0 58.9 54.6 49.8 44.5 38.6 Mutual thermal interference when an even load is applied at the same time. A correction factor must be taken into account in the case of butt-mounted MCBs and an evenly applied, high load: 2 and 3 MCBs multiply with factor 0.9 / 4 and 5 MCBs with factor 0.8 / 6 and more MCBs with factor 0.75 The interdependency becomes irrelevant if filling pieces or packing blocks FST...(9mm width) are used. 67 System pro M compact(R) Busbars and accessories acc. to UL 489, CSA 22.2 No. 5 PS 3/6/16 BP 2CDC 061 423 F0004 conn. No. capac. of mm2 pins Phases Ordering details Order code Type No. bbn 40 16779 EAN CuNo. 64496 9 64497 6 64498 3 0.035 0.070 0.105 1 1 1 64499 0 64500 3 64501 0 0.070 0.140 0.210 1 1 1 64502 7 64503 4 64504 1 0.110 0.221 0.332 1 1 1 Price Price Weight Pack 1 piece group 1 piece units piece kg UL approved busbars Preassembled busbars not cutable 1-phase busbars, pin distance 17.6 mm, UL 489 16 16 16 6 12 18 PS 1/6/16 BP PS 1/12/16 BP PS 1/18/16 BP 1 1 1 2CDL 210 489 R1606 2CDL 210 489 R1612 2CDL 210 489 R1618 2-phase busbars, pin distance 17.6 mm, UL 489 16 16 16 6 12 18 PS 2/6/16 BP PS 2/12/16 BP PS 2/18/16 BP 2 2 2 2CDL 220 489 R1606 2CDL 220 489 R1612 2CDL 220 489 R1618 3-phase busbars, pin distance 17.6 mm, UL 489 16 16 16 6 12 18 PS 3/6/16 BP PS 3/12/16 BP PS 3/18/16 BP 3 3 3 2CDL 230 489 R1606 2CDL 230 489 R1612 2CDL 230 489 R1618 Feeder terminals for S 200 U 6 - 50 6 - 50 angled feeding SZ-Ast 50 U straight feeding SZ-Ast 55 U 2CDL 200 489 R5001 2CDL 200 489 R5002 for S 200 UP 6 - 35 6 - 35 SZ-BSK SK 0100 B99 conn. capac. mm2 angled feeding SZ-Ast 50 UP straight feeding SZ-Ast 55 UP 2CDL 200 489 R3511 2CDL 200 489 R3512 module Phases Ordering details bbn 40 16779 EAN Order code Type No. Price Price Weight Pack 1 piece group 1 piece units piece kg Shock-protection caps for PS... busbar blocks 5-parts SZ-BSK 2CDL 200 001 R0011 42000 6 0.003 10 Ring-tongue terminal SZ-Ast 55UP RT The terminal SZ-Ast 55UP RT is for connection of copper ring-tongue to our MCBs S 200 UP. Technical data SZ-Ast 55UP RT Max. electrical load 100 A Max. operating voltage 600 V AC Max. torque 3 Nm Insulation Cycoloy C 2100 UL-V0 Use single UL listed or CSA certified insulated ring terminal only with max. width 0.46 inch (12 mm). SZ-Ast 55UP RT 2CDL 201 489 R0012 65011 3 0.011 50 2CDC 062 111 F0204 2CDC 062 130 F0005 2CDC 062 614 F0204 Dimension drawings in mm SZ-Ast 55UP RT 68 System pro M Areas of application Miniature circuit-breakers for line and device protection as well as their respective areas of applications S 200 S 200M S 201 DC S 280 UC S 200 P S 220 S 500 S 700 WT 63 S 220 S 500 S 500 HV WT 63 S 220-K S 500-K S 700-K industrial networks 690 V 1000 V motor protection transformer S 200P-K S 200-K 250 V... to photovoltaics 1200 V... S 280UC USV semiconductor control circuits 24 V DC S 500 UC S 200P-Z S 200-Z high discrimination S 700 disconnector and main circuit breaker capabilities USA, Canada 1077 480 V AC 500 V DC S 200 USA, Canada S 200 P S 220 S 500 S 200 P S 280 UC S 220 S 500 S 200 P S 280 UC S 220 S 500 S 700 (GL) S 700 S 201 DC 60 V DC/AC 240 V AC 489 480Y/ 277 V AC S 200 U S 200 UP nautical classificationen GL BV LRS DNV rated current switching capacity (230/400 V) Icn /A In /A innovative cost reduction System pro M compact(R) S 200 6 000 10 000 63 14 000 25 000 10 000 50 000 25 000 25 25 32 63 100 S 200 S 200M S 201 DC S 200 P as selective group or full automat 69 Notes 70 Notes 71 Pub. No. 2CDC 002 053 D0201 ABB STOTZ-KONTAKT GmbH P.O. Box 10 16 80, 69006 Heidelberg, Germany Eppelheimer Strae 82, 69123 Heidelberg, Germany Telephone +49-(0) 62 21-7 01-0 Telefax +49-(0) 62 21-7 01-723 www.abb.de/stotz-kontakt