General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications * Models with lockable test buttons now available. * Many variations possible through a selection of operation indicators (mechanical and LED indicators), lockable test button, built-in diode and CR (surge suppression), bifurcated contacts, etc. * Arc barrier standard on 4-pole Relays. * Dielectric strength: 2,000 VAC (coil to contact) * Environment-friendly cadmium-free contacts. * Safety standard approvals obtained. * Wide range of Sockets (PY, PYF Series) and optional parts are available. * Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A * Provided with nameplate. LR Ordering Information Relays Standard Coil Polarity Type Contact form Plug-in socket/Solder terminals Standard with LED indicator Standard With built-in diode (DC only) With built-in CR (220/240 VAC, 110/120 VAC only) Without LED indicator With LED indicator and lockable test button DPDT MY2N MY2IN 4PDT MY4N MY4IN MY2 MY4 4PDT (bifurcated) MY4ZN MY4ZIN MY4Z DPDT MY2N-D2 MY2IN-D2 --- 4PDT MY4N-D2 MY4IN-D2 --- 4PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- DPDT MY2N-CR MY2IN-CR --- 4PDT MY4N-CR MY4IN-CR --- 4PDT (bifurcated) MY4ZN-CR MY4ZIN-CR --- Reverse Coil Polarity Type Contact form Plug-in socket/Solder terminals With LED indicator Standard (DC only) With built-in diode (DC only) With LED indicator and lockable test button DPDT MY2N1 MY2IN1 4PDT MY4N1 MY4IN1 4PDT (bifurcated) MY4ZN1 MY4ZIN1 DPDT MY2N1-D2 MY2IN1-D2 4PDT MY4N1-D2 MY4IN1-D2 4PDT (bifurcated) MY4ZN1-D2 MY4ZIN1-D2 Note: When ordering, add the rated coil voltage and "(s)" to the model number. Rated coil voltages are given in the coil ratings table. Example: MY2 6VAC (S) New model Rated coil voltage General-purpose Relay MY New model 1 Accessories (Order Separately) Sockets Poles Front-mounting Socket (DIN-track/ screw mounting) Back-mounting Socket Solder terminals Without clip Wire-wrap terminals With clip Without clip PCB terminals With clip 2 PYF08A-E PYF08A-N PY08 PY08-Y1 PY08QN PY08QN2 PY08QN-Y1 PY08QN2-Y1 PY08-02 4 PYF14A-E PYF14A-N PY14 PY14-Y1 PY14QN PY14QN2 PY14QN-Y1 PY14QN2-Y1 PY14-02 Socket Hold-down Clip Pairing Relay type Poles Front-connecting Socket (DIN-track/ screw mounting) Socket Without 2-pole test 2 button PYF08A-E PYF08A-N 4 PYF14A-E PYF14A-N 2 PYF08A-E PYF08A-N 2-pole test button Back-connecting Socket Solder/Wire-wrap terminals Clip Socket PYC-A1 PCB terminals Clip PY08(QN) Socket PYC-P PYC-P2 PY14(QN) PYC-E1 Clip PY08-02 PYC-P PYC-P2 PY14-02 PY08(QN) PYC-P2 PY08-02 PYC-P2 Mounting Plates for Sockets Socket model For 1 Socket PY08, PY08QN(2), PY14, PY14QN(2) For 18 Sockets PYP-1 For 36 Sockets PYP-18 PYP-36 Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets. Track and Accessories Supporting Track (length = 500 mm) PFP-50N Supporting Track (length = 1,000 mm) PFP-100N, PFP-100N2 End Plate PFP-M Spacer PFP-S Specifications Coil Ratings Rated voltage Rated current 50 Hz AC DC Coil resistance 60 Hz Coil inductance (reference value) Arm. OFF Arm. ON 6 V* 214.1 mA 183 mA 12.2 0.04 H 0.08 H 12 V 106.5 mA 91 mA 46 0.17 H 0.33 H 24 V 53.8 mA 46 mA 180 0.69 H 1.30 H 48/50 V* 24.7/ 25.7 mA 21.1/ 22.0 mA 788 3.22 H 5.66 H 110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 19.20 H 32.1 H 4.2/4.6 mA 220/240 V 4.8/5.3 mA 18,790 83.50 H 136.4 H 6 V* 151 mA 39.8 0.17 H 0.33 H 12 V 75 mA 160 0.73 H 1.37 H 24 V 37.7 mA 636 3.20 H 5.72 H 48 V* 18.8 mA 2,560 10.60 H 21.0 H 100/110 V 9.0/9.9 mA 11,100 45.60 H 86.2 H Must operate voltage Must release voltage Max. voltage Power consumption (approx.) % of rated voltage 80% max. 30% min. 110% 1.0 to 1.2 VA (60 Hz) 0.9 to 1.1 VA (60 Hz) 10% min. 0.9 W Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for rated currents and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. 5. Rated voltage denoted by "*" will be manufactured upon request. Ask your OMRON representative. 2 General-purpose Relay MY New model Contact Ratings Item 2-pole Resistive load (cos = 1) 4-pole Inductive load (cos = 0.4, L/R = 7 ms) 2A, 250 VAC 2 A, 30 VDC Resistive load (cos = 1) Rated load 5A, 250 VAC 5A, 30 VDC Carry current 10 A (see note) 5 A (see note) Max. switching voltage 250 VAC 125 VDC 250 VAC 125 VDC Max. switching current 10 A 5A Max. switching power 2,500 VA 300 W Failure rate (reference value) 5 VDC, 1 mA 1,250 VA 300 W 3 A, 250 VAC 3 A, 30 VDC 1,250 VA 150 W 4-pole (bifurcated) Inductive load (cos = 0.4, L/R = 7 ms) Resistive load (cos = 1) Inductive load (cos = 0.4, L/R = 7 ms) 0.8 A, 250 VAC 1.5 A, 30 VDC 3 A, 250 VAC 3 A, 30 VDC 0.8 A, 250 VAC 1.5 A, 30 VDC 500 VA 150 W 1,250 VA 150 W 500 VA 150 W 1 VDC, 100 A 1 VDC, 1 mA Note: Don't exceed the carry current of a Socket in use. Please see page 9. Characteristics Item All Relays Contact resistance 100 m max. Operate time 20 ms max. Release time 20 ms max. Max. operating frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude) Shock resistance Destruction: 1,000 m/s2 Malfunction: 200 m/s2 Endurance See the following table. Ambient temperature Operating: -55C to 70C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 35 g Note: The values given above are initial values. Endurance Characteristics Pole 2-pole Mechanical life (at 18,000 operations/hr) Electrical life (at 1,800 operations/hr under rated load) AC:50,000,000 operations min. DC:100,000,000 operations min. 500,000 operations min. 4-pole 4-pole (bifurcated) 20,000,000 operations min. 100,000 operations min. 200,000 operations min. General-purpose Relay MY New model 3 Approved Standards VDE Recognitions (File No. 112467UG, IEC 255, VDE 0435) No. of poles 2 Coil ratings Contact ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC 4 Operations 10 A, 250 VAC (cos=1) 10 A, 30 VDC (L/R=0 ms) 10 x 103 5 A, 250 VAC (cos=1) 5 A, 30 VDC (L/R=0 ms) 100 x 103 MY4Z AC; 50 x 103 UL508 Recognitions (File No. 41515) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 30 VDC (General purpose) 10 A, 250 VAC (General purpose) 4 Operations 6 x 103 5 A, 250 VAC (General purpose) 5 A, 30 VDC (General purpose) CSA C22.2 No. 14 Listings (File No. LR31928) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC Contact ratings 10 A, 30 VDC 10 A, 250 VAC 4 Operations 6 x 103 5 A, 250 VAC (Same polarity) 5 A, 30 VDC (Same polarity) IMQ (File No. EN013 to 016) No. of poles 2 Coil ratings 6, 12, 24, 48/50, 100/110 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110, 125 VDC 4 Contact ratings Operations 10 A, 30 VDC 10 A, 250 VAC 10 x 10 5 A, 250 VAC 5 A, 30 VDC 100 x 103 MY4Z AC; 50 x 103 3 LR Recognitions (File No. 98/10014) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC 4 Contact ratings Operations 10 A, 250 VAC (Resistive) 2 A, 250 VAC (PF0.4) 10 A, 30 VDC (Resistive) 2 A, 30 VDC (L/R=7 ms) 50 x 103 5 A, 250 VAC (Resistive) 0.8 A, 250 VAC (PF0.4) 5 A, 30 VDC (Resistive) 1.5 A, 30 VDC (L/R=7 ms) 50 x 103 SEV Listings (File No. 99.5 50902.01) No. of poles 2 Coil ratings 6 to 240 VAC 6 to 125 VDC 4 4 General-purpose Relay MY Contact ratings Operations 10 A, 250 VAC 10 A, 30 VDC 10 x 103 5 A, 250 VAC 5 A, 30 VDC 100 x 103 MY4Z AC; 50 x 103 New model Engineering Data Maximum Switching Power AC resistive load AC inductive load (cos=0.4) DC resistive load Switching current (A) MY4, MY4Z Switching current (A) MY2 AC resistive load AC inductive load (cos=0.4) DC resistive load DC inductive load (L/R=7 ms) DC inductive load (L/R=7 ms) Switching voltage (V) Switching voltage (V) Endurance MY2 (Inductive Loads) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 250 VAC 100 Endurance (x10 3operations) Endurance (x10 3 operations) MY2 (Resistive Loads) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 250 VAC 100 50 30 50 30 10 10 Switching current (A) MY4 (Resistive Loads) MY4 (Inductive Loads) Endurance (x10 3 operations) Endurance (x10 3 operations) Switching current (A) 10000 5000 3000 250 VAC 1000 500 300 30 VDC 30 VDC 100 250 VAC 50 30 10 10000 5000 3000 30 VDC 1000 500 300 30 VDC 250 VAC 100 50 30 250 VAC 10 Switching current (A) Switching current (A) General-purpose Relay MY New model 5 MY4Z (Inductive Loads) Endurance (x10 3operations) Endurance (x10 3 operations) MY4Z (Resistive Loads) 10000 5000 3000 1000 250 VAC 500 300 30 VDC 100 50 30 30 VDC 250 VAC 10 10000 5000 3000 1000 30 VDC 100 50 30 250 VAC 250 VAC 10 Switching Current (A) 6 30 VDC 500 300 General-purpose Relay MY New model Switching Current (A) Dimensions Note: All units are in millimeters unless otherwise indicated. 2-Pole Models MY2N 2.6 Eight, 1.2 dia. x 2.2 long holes 0.5 28 max. 6.4 36 max. 21.5 max. 4-Pole Models MY4N 2.6 Eight, 1.2 dia. x 2.2 long holes 0.5 28 max. 36 max. 6.4 21.5 max. Models with Test Button MY2IN 2.6 Eight, 1.2 dia. x 2.2 long holes 6.3 8 14.2 80.5 5 28 max. 36 max. 21.5 max. MY4IN 2.6 Fourteen, 1.2 dia. x 2.2 long holes 0.5 6.3 8 14.2 80.5 5 28 max. 36 max. <1.417> 6.4 21.5 max. General-purpose Relay MY New model 7 Terminal Arrangement/Internal Connections (Bottom View) MY2 MY2N/MY2IN (AC Models) MY2N/MY2IN (DC Models) 1 4 1 4 1 4 1 4 5 8 5 8 5 8 5 8 9 12 9 12 9 12 9 13 14 13 14 MY2N-CR/MY2IN-CR (AC Models Only) MY4(Z) 13 - + 14 MY2N1/MY2IN1 (DC Models Only) 13 12 - + 14 MY2N1-D2/MY2IN1-D2 (DC Models Only) 1 4 1 4 1 4 5 8 5 8 5 8 9 12 9 12 9 13 14 MY4(Z)N/MY4(Z)IN (AC Models) 13 + - 14 MY4(Z)N/MY4(Z)IN (DC Models) 13 12 + - 14 MY4(Z)N-D/MY4(Z)IN-D2 (DC Models Only) 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 14 13 14 13 13 14 MY4(Z)N-CR/MY4(Z)IN-CR (AC Models Only) - + MY4(Z)N1/MY4(Z)IN1 (DC Models Only) - + 14 MY4(Z)N1-D2/MY4(Z)IN1-D2 (DC Models Only) 2 3 4 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 5 6 7 8 9 10 11 12 14 13 14 Note: The DC models have polarity. General-purpose Relay MY 13 1 13 8 MY2N-D2/MY2IN-D2 (DC Models Only) New model 13 + - + - 14 Socket for MY Track-mounted (DIN Track) Socket Conforms to VDE 0106, Part 100 * Snap into position along continuous sections of any mounting track. * Facilitates sheet metal design by standardized mounting dimensions. * Design with sufficient dielectric separation between terminals eliminates the need of any insulating sheet. Safety Standards for Sockets Model Standards PYF08A-E, PYF08A-N PYF14A-E, PYF14A-N File No. UL508 E87929 CSA22.2 LR31928 Back-connecting Sockets Specifications Item Pole Model Carry current Screwless Clamp Terminal Socket 2 PYF08S 10 A 4 PYF14S 5A Track-mounted Socket 2 PYF08A-E 7A PYF08A-N (see note 3) 7 A (see note 4) 4 Back-connecting Socket 2 PYF14A-E 5A PYF14A-N (see note 3) 5 A (see note 4) PY08(-Y1) 7A Dielectric withstand voltage Insulation resistance (see note 2) 2,000 VAC, 1 min Less than 1,000 M 2,000 VAC, 1 min 1,000 M min. 1,500 VAC, 1 min 100 M min. PY08QN(-Y1) PY08-02 4 PY14(-Y1) 3A PY14QN(-Y1) PY14-02 Note: 1. 2. 3. 4. 5. The values given above are initial values. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55C. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40C, reduce the current to 60%. The MY2(S) can be used at 70C with a carry current of 7 A. General-purpose Relay MY New model 9 Dimensions Note: All units are in millimeters unless otherwise indicated. Socket Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes 38.2 max. 36.5 max. PYF08S 23.2 max. --- 85 max. (5.3) PYF08A-E Two, M3, M4, or 4.5-dia. holes Two, 4.2 x 5 mounting holes Eight, M3 x 8 sems screws 72 max. (TOP VIEW) 23 max. Note: Track mounting is also possible. Refer to page 12 for supporting tracks. 31 max. 22 max. PYF08A-N 4 1 42 12 8 5 44 14 42 4 44 8 12 1 14 5 67 max. 3.5 dia. or M3 73 PYF-08A-N 41 11 12 9 A2 A2 A1 14 14 13 12 9 41 11 14 14 13 A2 A2 A1 30 max. 10 3.0 dia. 18.7 General-purpose Relay MY New model Note: Track mounting is also possible. Refer to page 12 for supporting tracks. Socket Dimensions Terminal arrangement/ Internal connections (top view) Mounting holes 36.5 max. PYF14S 31 max. --- 85 max. PYF14A-E Two, 4.2 x 5 mounting holes Two, M3, M4, or 4.5-dia. holes Fourteen, M3 x 8 sems screws 72 max. (TOP VIEW) Note: Track mounting is also possible. Refer to page 12 for supporting tracks. 29.5 max. 31 max. 42 4 44 8 PYF14A-N 4 3 2 1 42 32 22 12 8 7 6 5 44 34 24 14 32 3 34 7 22 2 24 6 12 1 14 5 Two, 4.5 dia. or M4 67 max. PYF-14A-N 41 31 21 11 12 11 10 9 A2 A2 A1 14 14 13 29.5 max. 26 73 12 11 10 9 41 31 21 11 30 max. 14 14 A2 A2 13 A1 General-purpose Relay Note: Track mounting is also possible. Refer to page 12 for supporting tracks. MY New model 11 Socket PY08/PY08-Y1 Dimensions (See note) Terminal arrangement/ Internal connections (bottom view) Mounting holes Eight, 3 x 1.2 elliptical holes 25.5 max. 29.5 max. 20 max. 42 max. 24 max. Note: The PY08-Y1 includes sections indicated by dotted lines. PY08QN/ PY08QN-Y1 (See note) 29.5 max. 22 max. 41.5 max. 24 max. 42 max. Note: The PY08QN-Y1 includes sections indicated by dotted lines. PY08-02 25.5 max. 29.5 max. 22 max. Eight, 1.3-dia. holes 16.5 max. PY14/PY14-Y1 (See note) Fourteen, 3 x 1.2 elliptical holes 25.5 max. 29.5 max. 42 max. 20 max. 24 max. Note: The PY14-Y1 includes sections indicated by dotted lines. PY14QN/ PY14QN-Y1 (See note) 29.5 max. 41.5 max. 42 max. 22 max. 24 max. Note: The PY14QN-Y1 includes sections indicated by dotted lines. PY14-02 25.5 max. 29.5 max. 22 max. Fourteen, 1.3-dia. holes 16.5 max. Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets. 12 General-purpose Relay MY New model Hold-down Clips PYC-A1 (2 pcs per set) PYC-E1 (2 pcs per set) 36.3 36.3 5.75 4.5 4.25 4.50.1 1.2 4.5 PYC-P PYC-P2 5 10 29 max. 28 3.3 38.5 Mounting Plates for Back-connecting Sockets PYP-1 PYP-36 Two, 3.4-dia. holes 72 elliptical holes t=1.6 PYP-18 72 elliptical holes General-purpose Relay MY New model 13 Tracks and Accessories Supporting Tracks PFP-50N/PFP-100N 7.30.15 4.5 350.3 270.15 1 15 25 10 25 25 1000 (500) * 10 15 (5) 25 Note: The figure in the parentheses is for PFP-50N. PFP-100N2 16 4.5 350.3 27 25 15 10 25 1000 25 10 25 15 End Plate PFP-M 10 6.2 M4 x 8 pan head screw 1.8 1 50 1.8 11.5 1.3 10 M4 spring washer 4.8 Spacer PFP-S 16 12 5 34.8 44.3 16.5 14 General-purpose Relay MY New model 35.5 35.3 24 1 29.2 1.5 Precautions Refer to General Precautions on page 11 of the General-purpose Relays and Power Relays Group Catalog (X034). Connections Do not reverse polarity when connecting DC-operated Relays with built-in diodes or indicators or high-sensitivity DC-operated Relays. Mounting * Whenever possible, mount Relays so that it is not subject to vibration or shock in the same direction as that of contact movement. General-purpose Relay MY New model 15 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J111-E1-03 In the interest of product improvement, specifications are subject to change without notice. OMRON RELAY & DEVICES Corporation General Purpose Relay Division Marketing & Product Engineering Department 1110 Sugi, Yamaga-City, Kumamoto, 861-0596 Japan Tel: (81)968-44-4160/Fax: (81)968-44-4107 16 Printed in Japan Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. Cat. No. J111-E1-03 OMRON Corporation 2007. 3 In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.