DPF-2
MODEL DPF1000
AC INPUT[V] AC85 - 264 AC170-264
MAX OUTPUTWATTAGE[W] 1,000 1,500
DC OUTPUTVOLTAGE[V] DC360
SPECIFICATIONS
MODEL DPF1000
INPUT
VOLTAGE[V] AC85 -264 1fAC170 -264 1f
POWER FACTOR CORRECTION RANGE[V]
AC85 -255 1f
CURRENT[A] 11.5typ (ACIN 100V)8.5typ (ACIN 200V)
FREQUENCY[Hz] 50/60 (47-63)
INRUSH CURRENT[A] Limitedbyexternal resistance
EFFICIENCY[%] 90typ (ACIN 100V)95typ (ACIN 200V)
POWER FACTOR 0.98typ (ACIN 100V)0.95typ (ACIN 200V)
LEAKAGE CURRENT[mA]
0.75max (60Hz,Accordingto IEC60950 and DEN-AN)
OUTPUT
WATTAGE[W]
*1
1,000 1,500
VOLTAGE[V]
*2
DC360
VOLTAGE ACCURACY[V]
*3
t20
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V]
DC400-450 The powerfactor corrector function stops
IOG
Inverter operation monitoring,Open-collector output,Maximum sink current 10mA,Maximum allowancevoltage 35V
ENA Enable signal,Open-collector output,Maximum sink current 10mA,Maximum allowance voltage 35V
AUXAuxiliarypower supplyfor external signal,Outputvoltage:6.5 - 8.5V maximum,Output current:10mA
OTHERS
Parallel operation possible (Current balancing function), N+1 redundant operation possible,Thermal protection
ISOLATION
INPUT-OUTPUT Non isolated
INPUT,OUTPUT-FG AC3,000V 1minute Cutoff current=10mA,DC500V,50MWmin (20t15C)
ENVIRONMENT
OPERATINGTEMP.,HUMID.ANDALTITUDE
*4
-20to +85C(Aluminum base plate), 20-95%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.ANDALTITUDE
-40 to +85C,20-95%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10-55Hz,49.0m/s2(5G), 3minutes period,60minutes each alongX
,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once eachX
,Yand Z axis
SAFETY AGENCY APPROVALS UL60950-1,C-UL,EN60950-1,EN50178 Complies with DEN-AN and IEC60950-1
HARMONICATTENUATOR
Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 118.6X12.7X85mm [4.67X0.5X3.35 inches] (WXHXD)/200g max
COOLINGMETHOD Conduction cooling (e.g. heatradiation from the aluminum base plateto the attached heat sink)
*5
*1 Refer to Input voltage derating.
*2
When the input voltage is more than 255V, the power factor corrector function stops, and the
output voltage becomes rectified AC input voltage.
*3
The value included the output setting and the line regulation, the load regulation and the
temperature regulation.
However, the input voltage is in the power factor correction range.
*4
Please consult us in regard to use from -40C.
*5
Please contact us about class C.
*
External components are required. Refer to standard connection method.
DPF1000
AC-DC Power Supplies Bus Converter∙Power Module Type
DPF 1000
Ordering information
1 Series name
2 Output wattage
1 2