cui.com
date 08/31/2018 │ page 2 of 5CUI Inc │ SERIES: SWI6-N │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 0.19 A
inrush current at240Vac,fullload,25°C,coldstart 60 A
leakagecurrent 0.25 mA
no load power consumption at115/230Vac 0.1 W
OUTPUT
parameter conditions/description min typ max units
regulation 3.3 Vdc output model
all other models
±10
±5
%
%
hold-up time at full load 10 ms
PROTECTIONS
parameter conditions/description min typ max units
overvoltageprotection output shut down 180 %
overcurrentprotection
outputshutdown,autorecovery
3.3 Vdc output model
5 Vdc output model
5.9 Vdc output model
7.5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
3.5
3.5
3
2.5
1.5
1.5
1.3
A
A
A
A
A
A
A
short circuit protection outputshutdown,autorecovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolationvoltage input to output at 10 mA for 1 minute 3,000 Vac
isolation resistance input to output at 500 Vdc 10 MΩ
safetyapprovals UL/cUL(60950-1,62368-1),PSE
EMI/EMC FCCPart15BClassB
MTBF asperTelcordiaSR-332,25°C 300,000 hours
RoHS yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operatingtemperature 0 40 °C
storagetemperature -20 60 °C
operatinghumidity non-condensing 20 80 %
storagehumidity non-condensing 10 90 %
For more information, please visit the product page | For information on related products, view Dc Power Connectors