EVALUATION KIT AVAILABLE MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge General Description The MAX17040/MAX17041 are ultra-compact, low-cost, host-side fuel-gauge systems for lithium-ion (Li+) batteries in handheld and portable equipment. The MAX17040 is configured to operate with a single lithium cell and the MAX17041 is configured for a dual-cell 2S pack. The MAX17040/MAX17041 use a sophisticated Li+ battery-modeling scheme, called ModelGaugeTM to track the battery's relative state-of-charge (SOC) continuously over a widely varying charge/discharge profile. Unlike traditional fuel gauges, the ModelGauge algorithm eliminates the need for battery relearn cycles and an external current-sense resistor. Temperature compensation is possible in the application with minimal interaction between a C and the device. The IC can be located on the system side, reducing cost and supply chain constraints on the battery. Measurement and estimated capacity data sets are accessed through an I2C interface. The MAX17040/MAX17041 are available in either a 0.4mm pitch 9-bump UCSPTM or 2mm x 3mm, 8-pin TDFN lead-free package. Applications Smartphones, Tablets Health and Fitness Monitors Medical Devices Digital Still, Video, and Action Cameras Features Host-Side or Battery-Side Fuel Gauging * 1 Cell (MAX17040) * 2 Cell (MAX17041) Precision Voltage Measurement * 12.5mV Accuracy to 5.00V (MAX17040) * 30mV Accuracy to 10.00V (MAX17041) Accurate Relative Capacity (RSOC) Calculated from ModelGauge Algorithm No Offset Accumulation on Measurement No Full-to-Empty Battery Relearning Necessary No Sense Resistor Required 2-Wire Interface Low Power Consumption Tiny, Lead(Pb)-Free, 8-Pin, 2mm x 3mm TDFN Package or Tiny 0.4mm Pitch 9-Bump UCSP Package Ordering Information PART Handheld Computers and Terminals Wireless Speakers ModelGauge is a trademark of Maxim Integrated Products, Inc. UCSP is a trademark of Maxim Integrated Products, Inc. Visit www.maximintegrated.com/products/patents for product patent marking information. TEMP RANGE PIN-PACKAGE MAX17040G+U -20C to +70C 8 TDFN-EP* MAX17040G+T -20C to +70C 8 TDFN-EP* MAX17040X+U -20C to +70C 9 UCSP MAX17040X+T10 -20C to +70C 9 UCSP MAX17041G+U -20C to +70C 8 TDFN-EP* MAX17041G+T -20C to +70C 8 TDFN-EP* MAX17041X+ -20C to +70C 9 UCSP MAX17041X+T10 -20C to +70C 9 UCSP +Denotes a lead(Pb)-free/RoHS-compliant package. T = Tape and reel. *EP = Exposed pad. Pin Configurations appear at end of data sheet. Simple Fuel Gauge Circuit Diagram 150 1k CELL SYSTEM P VDD MAX17040 MAX17041 SEO Li+ PROTECTION CIRCUIT EO 1F 19-5210; Rev 9; 10/16 CTG SDA GND SCL EP I2C BUS MASTER 10nF MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Absolute Maximum Ratings Voltage on CTG Pin Relative to GND....................-0.3V to +12V Voltage on CELL Pin Relative to GND...................-0.3V to +12V Voltage on All Other Pins Relative to GND..............-0.3V to +6V Operating Temperature Range............................ -40C to +85C Power Dissipation.......... 1333mW at +70C (derate 16.7mW/C) Storage Temperature Range (TA = 0C to +70C (Note 10))...................... -55C to +125C Lead Temperature (TDFN only, soldering, 10s)............... +300C Soldering Temperature (reflow)........................................+260C Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Electrical Characteristics Recommended DC Operating Conditions (2.5V VDD 4.5V, TA = -20C to +70C, unless otherwise noted.) PARAMETER Supply Voltage Data I/O Pins SYMBOL VDD CONDITIONS MIN TYP MAX UNITS (Note 1) +2.5 +4.5 V SCL, SDA, (Note 1) EO, SEO -0.3 +5.5 V MAX17040 CELL Pin VCELL (Note 1) -0.3 +5.0 V MAX17041 CELL Pin VCELL (Note 1) -0.3 +10.0 V UNITS DC Electrical Characteristics (2.5V VDD 4.5V, TA = -20C to +70C, unless otherwise noted. Contact Maxim for VDD greater than 4.5V.) PARAMETER SYMBOL Active Current IACTIVE Sleep-Mode Current (Note 2) ISLEEP Time-Base Accuracy (Note 3) tERR TYP MAX With on-chip clock in use CONDITIONS 50 75 With external 32kHz clock 40 65 VDD = 2.0V 0.5 1.0 1 3 VDD = 3.6V at +25C -1 +1 TA = 0C to +70C (Note 10) -2 +2 TA = -20C to +70C MAX17040 VoltageMeasurement Error MAX17041 VoltageMeasurement Error CELL Pin Input Impedance -3 +3 -12.5 +12.5 -30 +30 TA = +25C, 5.0V < VIN < 9.0V -30 +30 5.0V < VIN < 9.0V -60 +60 TA = +25C, VIN = VDD VGERR MIN RCELL A A % mV 15 M 1.4 V Input Logic-High: SCL, SDA, EO, SEO VIH (Note 1) Input Logic-Low: SCL, SDA, EO, SEO VIL (Note 1) 0.5 V Output Logic-Low: SDA VOL IOL = 4mA (Note 1) 0.4 V Pulldown Current: SCL, SDA IPD VDD = 4.5V, VPIN = 0.4V Input Capacitance: EO CBUS Bus Low Timeout tSLEEP www.maximintegrated.com (Note 4) 0.2 1.75 A 50 pF 2.5 s Maxim Integrated 2 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Electrical Characteristics: 2-Wire Interface (2.5V VDD 4.5V, TA = -20C to +70C.) PARAMETER SYMBOL SCL Clock Frequency fSCL Bus Free Time Between a STOP and START Condition tBUF Hold Time (Repeated) START Condition tHD:STA CONDITIONS (Note 5) (Note 5) MIN 0 TYP MAX UNITS 400 kHz 1.3 s 0.6 s Low Period of SCL Clock tLOW 1.3 s High Period of SCL Clock tHIGH 0.6 s Setup Time for a Repeated START Condition tSU:STA 0.6 s Data Hold Time tHD:DAT (Notes 6, 7) Data Setup Time tSU:DAT (Note 6) 0 0.9 100 s ns Rise Time of Both SDA and SCL Signals tR 20 + 0.1CB 300 ns Fall Time of Both SDA and SCL Signals tF 20 + 0.1CB 300 ns Setup Time for STOP Condition tSU:STO 0.6 Spike Pulse Widths Suppressed by Input Filter tSP (Note 8) Capacitive Load for Each Bus Line CB (Note 9) SCL, SDA Input Capacitance Note Note Note Note Note Note Note CBIN 0 s 50 ns 400 pF 60 pF 1: 2: 3: 4: 5: 6: 7: All voltages are referenced to GND. SDA, SCL = GND; EO, SEO idle. External time base on EO pin must meet this specification. The MAX17040/MAX17041 enter Sleep mode 1.75s to 2.5s after (SCL < VIL) AND (SDA < VIL). fSCL must meet the minimum clock low time plus the rise/fall times. The maximum tHD:DAT has only to be met if the device does not stretch the low period (tLOW) of the SCL signal. This device internally provides a hold time of at least 75ns for the SDA signal (referred to the VIHMIN of the SCL signal) to bridge the undefined region of the falling edge of SCL. Note 8: Filters on SDA and SCL suppress noise spikes at the input buffers and delay the sampling instant. Note 9: CB--total capacitance of one bus line in pF. Note 10: Applies to 8-pin TDFN-EP package type only. www.maximintegrated.com Maxim Integrated 3 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Typical Operating Characteristics (TA = +25C, unless otherwise noted.) SIMPLE C/2 RATE CYCLES* SOC ACCURACY TA = +70C 60 40 20 TA = -20C 80 0 1 2 3 4 60 2 50 0 40 -2 30 -4 -6 REFERENCE SOC: SOLID LINE 4 0 5 0 2 4 VDD (V) MAX17040 toc03 10 20 8 15 70 4 60 2 50 0 40 -2 30 -4 20 REFERENCE SOC: SOLID LINE 10 0 0 2 4 6 VOLTAGE ADC ERROR (mV) 6 SOC ERROR (%) STATE OF CHARGE (%) 80 ERROR (%) 6 8 10 -8 12 -10 TIME (hr) MAX17040/ MAX17041 SOC: DASHED LINE 90 6 20 SIMPLE C/4 RATE CYCLES* SOC ACCURACY 100 8 70 10 0 10 -6 ERROR (%) VCELL = 4.2V 10 VCELL = 3.0V 5 0 -5 VCELL = 3.6V -10 -15 -8 8 10 12 14 16 18 20 22 MAX17040 VOLTAGE ADC ERROR vs. TEMPERATURE MAX17040 toc04 TA = +25C MAX17040/ MAX17041 SOC: DASHED LINE 90 STATE OF CHARGE (%) QUIESCENT CURRENT (A) 80 MAX17040 toc02 100 MAX17040 toc01 100 SOC ERROR (%) QUIESCENT CURRENT vs. SUPPLY VOLTAGE -20 -10 -40 -15 10 35 60 85 TEMPERATURE (C) TIME (hr) C/2 RATE ZIGZAG PATTERN* SOC ACCURACY MAX17040 toc05 MAX17040/MAX17041 SOC: DASHED LINE STATE OF CHARGE (%) 90 80 8 6 ERROR (%) 70 10 4 60 2 50 0 40 -2 30 -4 20 0 -6 REFERENCE SOC: SOLID LINE 10 0 4 8 SOC ERROR (%) 100 -8 12 16 20 22 -10 TIME (hr) *Sample accuracy with custom configuration data programmed into the IC. www.maximintegrated.com Maxim Integrated 4 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Pin Description PIN NAME FUNCTION UCSP TDFN A1 8 SDA Serial Data Input/Output. Open-drain 2-wire data line. Connect this pin to the DATA signal of the 2-wire interface. This pin has a 0.2A typical pulldown to sense disconnection. A2 7 SCL Serial Clock Input. Input only 2-wire clock line. Connect this pin to the CLOCK signal of the 2-wire interface. This pin has a 0.2A typical pulldown to sense disconnection. A3 1 CTG Connect to Ground. Connect to GND during normal operation. B1 6 EO External 32kHz Clocking Signal. Input for external clocking signal to be the primary system clock. Configured to implement interrupt feature with a pulldown set on SEO pin. B2 -- N.C. No Connect. Do not connect. B3 2 CELL Battery-Voltage Input. The voltage of the cell pack is measured through this pin. C1 5 SEO External 32kHz Clocking Signal Enable Input. Input to enable external clocking signal on EO pin with a pullup state; a pulldown state to configure the interrupt feature. External 32kHz clock enable. Connects logic-low to enable external interrupt. C2 3 VDD Power-Supply Input. 2.5V to 4.5V input range. Connect to system power through a decoupling network. Connect a 10nF typical decoupling capacitor close to pin. C3 4 GND Ground. Connect to the negative power rail of the system. -- -- EP Exposed Pad (TDFN Only). Connect to ground. SDA tF tLOW tSP tF tSU:DAT tR tR tBUF tHD:STA SCL tHD:STA S tSU:STA tHD:DAT tSU:STO Sr P S Figure 1. 2-Wire Bus Timing Diagram VDD BIAS VOLTAGE REFERENCE IC GROUND Figure 2. Block Diagram www.maximintegrated.com EO MAX17040 MAX17041 ADC (VCELL) CELL GND Detailed Description TIME BASE (32kHz) SEO STATE MACHINE (SOC, RATE) CTG 2-WIRE INTERFACE SDA SCL Figure 1 shows the 2-wire bus timing diagram, and Figure 2 is the MAX17040/MAX17041 block diagram. ModelGauge Theory of Operation The MAX17040/MAX17041 use a sophisticated battery model, which determines the SOC of a nonlinear Li+ battery. The model effectively simulates the internal dynamics of a Li+ battery and determines the SOC. The model considers the time effects of a battery caused by the chemical reactions and impedance in the battery. The MAX17040/MAX17041 SOC calculation does not accumulate error with time. This is advantageous Maxim Integrated 5 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge compared to traditional coulomb counters, which suffer from SOC drift caused by current-sense offset and cell self-discharge. This model provides good performance for many Li+ chemistry variants across temperature and age. To achieve optimum performance, the MAX17040/ MAX17041 must be programmed with configuration data custom to the application. Contact the factory for details. Fuel-Gauge Performance The classical coulomb-counter-based fuel gauges suffer from accuracy drift due to the accumulation of the offset error in the current-sense measurement. Although the error is often very small, the error increases over time in such systems, cannot be eliminated, and requires periodic corrections. The corrections are usually performed on a predefined SOC level near full or empty. Some other systems use the relaxed battery voltage to perform corrections. These systems determine the true SOC based on the battery voltage after a long time of no activity. Both have the same limitation: if the correction condition is not observed over time in the actual application, the error in the system is boundless. In some systems, a full charge/ discharge cycle is required to eliminate the drift error. To determine the true accuracy of a fuel gauge, as experienced by end users, the battery should be exercised in a dynamic manner. The end-user accuracy cannot be understood with only simple cycles. The MAX17040/ MAX17041 do not suffer from the drift problem since they do not rely on the current information. IC Power-Up When the battery is first inserted into the system, there is no previous knowledge about the battery's SOC. The IC assumes that the battery has been in a relaxed state for the previous 30min. The first A/D voltage measurement is translated into a best "first guess" for the SOC. Initial error caused by the battery not being in a relaxed state fades over time, regardless of cell loading following this initial conversion. Because the SOC determination is convergent rather than divergent (as in a coulomb counter), this initial error does not have a long-lasting impact. www.maximintegrated.com Quick-Start A quick-start allows the MAX17040/MAX17041 to restart fuel-gauge calculations in the same manner as initial power-up of the IC. For example, if an application's power-up sequence is exceedingly noisy such that excess error is introduced into the IC's "first guess" of SOC, the host can issue a quick-start to reduce the error. A quickstart is initiated by a rising edge on the EO pin when SEO is logic-low, or through software by writing 4000h to the MODE register. External Oscillator Control When the SEO pin is logic-high, the MAX17040/ MAX17041 disable the 32kHz internal oscillator and rely on external clocking from the EO pin. A precision external clock source reduces current consumption during normal operation. When the SEO pin is logic-low, the EO pin becomes an interrupt input. Any rising edge detected on EO causes the MAX17040/MAX17041 to initiate a quick-start. Sleep Mode Holding both SDA and SCL logic-low forces the MAX17040/ MAX17041 into Sleep mode. While in Sleep mode, all IC operations are halted and power drain of the IC is greatly reduced. After exiting Sleep mode, fuel-gauge operation continues from the point it was halted. SDA and SCL must be held low for at least 2.5s to guarantee transition into Sleep mode. Afterwards, a rising edge on either SDA or SCL immediately transitions the IC out of Sleep mode. Power-On Reset (POR) Writing a value of 0054h to the COMMAND register causes the MAX17040/MAX17041 to completely reset as if power had been removed. The reset occurs when the last bit has been clocked in. The IC does not respond with an I2C ACK after this command sequence. Registers All host interaction with the MAX17040/MAX17041 is handled by writing to and reading from register locations. The MAX17040/MAX17041 have six 16-bit registers: SOC, VCELL, MODE, VERSION, RCOMP, and COMMAND. Register reads and writes are only valid if all 16 bits are transferred. Any write command that is terminated early is ignored. The function of each register is described as follows. All remaining address locations not listed in Table 1 are reserved. Data read from reserved locations is undefined. Maxim Integrated 6 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Table 1. Register Summary ADDRESS (HEX) REGISTER 02h-03h VCELL 04h-05h SOC 06h-07h MODE 08h-09h VERSION 0Ch-0Dh RCOMP FEh-FFh COMMAND READ/ WRITE DEFAULT (HEX) Reports 12-bit A/D measurement of battery voltage. R -- Reports 16-bit SOC result calculated by ModelGauge algorithm. R -- Sends special commands to the IC. W -- Returns IC version. R -- R/W 9700h W -- DESCRIPTION Battery compensation. Adjusts IC performance based on application conditions. Sends special commands to the IC. VCELL Register Battery voltage is measured at the CELL pin input with respect to GND over a 0 to 5.00V range for the MAX17040 and 0 to 10.00V for the MAX17041 with resolutions of 1.25mV and 2.50mV, respectively. The A/D calculates the average cell voltage for a period of 125ms after IC POR and then for a period of 500ms for every cycle afterwards. The result is placed in the VCELL register at the end of each conversion period. Figure 3 shows the VCELL register format. SOC Register The SOC register is a read-only register that displays the state of charge of the cell as calculated by the ModelGauge algorithm. The result is displayed as a percentage of the cell's full capacity. This register auto- matically adapts to variation in battery size since the MAX17040/MAX17041 naturally recognize relative SOC. Units of % can be directly determined by observing only the high byte of the SOC register. The low byte provides additional resolution in units 1/256%. The reported SOC also includes residual capacity, which might not be available to the actual application because of early termination voltage requirements. When SOC() = 0, typical applications have no remaining capacity. The first update occurs within 250ms after POR of the IC. Subsequent updates occur at variable intervals depending on application conditions. ModelGauge calculations outside the register are clamped at minimum and maximum register limits. Figure 4 shows the SOC register format. MSB--ADDRESS 02h 211 210 29 28 27 26 LSB--ADDRESS 03h 25 MSB 24 23 LSB MSB 22 21 20 0 0 0 0 LSB 0: BITS ALWAYS READ LOGIC 0 UNITS: 1.25mV FOR MAX17040 2.50mV FOR MAX17041 Figure 3. VCELL Register Format MSB--ADDRESS 04h 27 26 25 24 MSB 23 22 LSB--ADDRESS 05h 21 20 2-1 LSB MSB 2-2 2-3 2-4 2-5 2-6 2-7 2-8 LSB UNITS: 1.0% Figure 4. SOC Register Format www.maximintegrated.com Maxim Integrated 7 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge MODE Register Table 3. COMMAND Register Command The MODE register allows the host processor to send special commands to the IC (Figure 4). Valid MODE register write values are listed as follows. All other MODE register values are reserved. Table 2 shows the MODE register command. COMMAND 4000h Quick-Start COMMAND 0054h POR DESCRIPTION See the Power-On Reset (POR) description section. Application Examples The MAX17040/MAX17041 have a variety of configurations, depending on the application. Table 4 shows the most common system configurations and the proper pin connections for each. Table 2. MODE Register Command VALUE VALUE DESCRIPTION See the Quick-Start description section. Figure 5 shows an example application for a 1S cell pack. The MAX17040 is mounted on the system side and powered directly from the cell pack. The external RC networks on VDD and CELL provide noise filtering of the IC power supply and A/D measurement. In this example, the SEO pin is connected to VDD to allow an external clock and reduce power usage by the MAX17040. The system's 32kHz clock is connected to the EO input pin. VERSION Register The VERSION register is a read-only register that contains a value indicating the production version of the MAX17040/MAX17041. RCOMP Register Figure 6 shows a MAX17041 example application using a 2S cell pack. The MAX17041 is mounted on the system side and powered from a 3.3V supply generated by the system. The CELL pin is still connected directly to PACK+ through an external noise filter. The SEO pin is connected low to allow the system hardware to reset the fuel gauge. After power is supplied, the system watchdog generates a low-to-high transition on the EO pin to signal the MAX17041 to perform a quick-start. RCOMP is a 16-bit value used to compensate the ModelGauge algorithm. RCOMP can be adjusted to optimize performance for different lithium chemistries or different operating temperatures. Contact Maxim for instructions for optimization. The factory-default value for RCOMP is 9700h. COMMAND Register The COMMAND register allows the host processor to send special commands to the IC. Valid COMMAND register write values are listed as follows. All other COMMAND register values are reserved. Table 3 shows the COMMAND register command. Table 4. Possible Application Configurations IC VDD SEO EO 1S Pack-Side Location SYSTEM CONFIGURATION MAX17040 Power directly from battery Connect to GND Connect to GND 1S Host-Side Location MAX17040 Power directly from battery Connect to GND Connect to GND 1S Host-Side Location, External Clocking MAX17040 Power directly from battery Connect to VDD Connect to precision 32kHz clock source 1S Host-Side Location, Hardware Quick-Start MAX17040 Power directly from battery Connect to GND Connect to risingedge reset signal 2S Pack-Side Location MAX17041 Power from 2.5V to 4.5V LDO in pack Connect to GND Connect to GND 2S Host-Side Location MAX17041 Power from 2.5V to 4.5V LDO or PMIC Connect to GND Connect to GND 2S Host-Side Location, External Clocking MAX17041 Power from 2.5V to 4.5V LDO or PMIC Connect to VDD Connect to precision 32kHz clock source 2S Host-Side Location, Hardware Quick-Start MAX17041 Power from 2.5V to 4.5V LDO or PMIC Connect to GND Connect to risingedge reset signal www.maximintegrated.com Maxim Integrated 8 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge BATTERY SYSTEM SYSTEM VDD PACK+ 150 1k VDD CELL PROTECTION IC (Li+/POLYMER) 1F SYSTEM P MAX17040 SEO 32kHz OSCILLATOR OUTPUT I2C BUS EO SDA CTG GND SCL EP MASTER 10nF SYSTEM GND PACK- Figure 5. MAX17040 Application Example with External Clock BATTERY SYSTEM SYSTEM VDD PACK+ 1k PROTECTION IC (Li+/POLYMER) 1F CELL SEO VDD EO 3.3V OUTPUT CTG GND SDA SCL I2C BUS MASTER SYSTEM P EP PACK- SYSTEM PMIC MAX17041 WATCHDOG SYSTEM GND Figure 6. MAX17041 Application Example with Hardware Reset 2-Wire Bus System The 2-wire bus system supports operation as a slave-only device in a single or multislave, and single or multimaster system. Slave devices can share the bus by uniquely setting the 7-bit slave address. The 2-wire interface consists of a serial data line (SDA) and serial clock line (SCL). SDA and SCL provide bidirectional communication between the MAX17040/MAX17041 slave device and a master device at speeds up to 400kHz. The MAX17040/ www.maximintegrated.com MAX17041s' SDA pin operates bidirectionally; that is, when the MAX17040/MAX17041 receive data, SDA operates as an input, and when the MAX17040/MAX17041 return data, SDA operates as an open-drain output, with the host system providing a resistive pullup. The MAX17040/MAX17041 always operate as a slave device, receiving and transmitting data under the control of a master device. The master initiates all transactions on the bus and generates the SCL signal, as well as the START and STOP bits, which begin and end each transaction. Maxim Integrated 9 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Bit Transfer Data Order Bus Idle Slave Address One data bit is transferred during each SCL clock cycle, with the cycle defined by SCL transitioning low to high and then high to low. The SDA logic level must remain stable during the high period of the SCL clock pulse. Any change in SDA when SCL is high is interpreted as a START or STOP control signal. The bus is defined to be idle, or not busy, when no master device has control. Both SDA and SCL remain high when the bus is idle. The STOP condition is the proper method to return the bus to the idle state. START and STOP Conditions The master initiates transactions with a START condition (S) by forcing a high-to-low transition on SDA while SCL is high. The master terminates a transaction with a STOP condition (P), a low-to-high transition on SDA while SCL is high. A Repeated START condition (Sr) can be used in place of a STOP then START sequence to terminate one transaction and begin another without returning the bus to the idle state. In multimaster systems, a Repeated START allows the master to retain control of the bus. The START and STOP conditions are the only bus activities in which the SDA transitions when SCL is high. Acknowledge Bits Each byte of a data transfer is acknowledged with an Acknowledge bit (A) or a No-Acknowledge bit (N). Both the master and the MAX17040 slave generate acknowledge bits. To generate an acknowledge, the receiving device must pull SDA low before the rising edge of the acknowledge-related clock pulse (ninth pulse) and keep it low until SCL returns low. To generate a no acknowledge (also called NAK), the receiver releases SDA before the rising edge of the acknowledge-related clock pulse and leaves SDA high until SCL returns low. Monitoring the Acknowledge bits allows for detection of unsuccessful data transfers. An unsuccessful data transfer can occur if a receiving device is busy or if a system fault has occurred. In the event of an unsuccessful data transfer, the bus master should reattempt communication. www.maximintegrated.com A byte of data consists of 8 bits ordered most significant bit (MSb) first. The least significant bit (LSb) of each byte is followed by the Acknowledge bit. The MAX17040/ MAX17041 registers composed of multibyte values are ordered MSB first. The MSB of multibyte registers is stored on even data-memory addresses. A bus master initiates communication with a slave device by issuing a START condition followed by a Slave Address (SAddr) and the Read/Write (R/W) bit. When the bus is idle, the MAX17040/MAX17041 continuously monitor for a START condition followed by its Slave Address. When the MAX17040/MAX17041 receive a Slave Address that matches the value in the Slave Address Register, it responds with an Acknowledge bit during the clock period following the R/W bit. The 7-bit slave address is fixed to 6Ch (write)/6DH (read): MAX17040/MAX17041 SLAVE ADDRESS 0110110 Read/Write Bit The R/W bit following the slave address determines the data direction of subsequent bytes in the transfer. R/W = 0 selects a write transaction, with the following bytes being written by the master to the slave. R/W = 1 selects a read transaction, with the following bytes being read from the slave by the master. Bus Timing The MAX17040/MAX17041 are compatible with any bus timing up to 400kHz. No special configuration is required to operate at any speed. 2-Wire Command Protocols The command protocols involve several transaction formats. The simplest format consists of the master writing the START bit, slave address, R/W bit, and then monitoring the Acknowledge bit for presence of the MAX17040/ MAX17041. More complex formats, such as the Write Data and Read Data, read data and execute devicespecific operations. All bytes in each command format require the slave or host to return an Acknowledge bit before continuing with the next byte. Table 5 shows the key that applies to the transaction formats. Maxim Integrated 10 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Table 5. 2-Wire Protocol Key KEY DESCRIPTION KEY DESCRIPTION S START bit Sr Repeated START SAddr Slave address (7 bit) W R/W bit = 0 MAddr Memory address byte P STOP bit Data Data byte written by master Data Data byte returned by slave A Acknowledge bit--master A Acknowledge bit--slave N No acknowledge--master N No acknowledge--slave Basic Transaction Formats Write: S. SAddr W. A. MAddr. A. Data0. A. Data1. A. P A write transaction transfers 2 or more data bytes to the MAX17040/MAX17041. The data transfer begins at the memory address supplied in the MAddr byte. Control of the SDA signal is retained by the master throughout the transaction, except for the acknowledge cycles: Read: S. SAddr W. A. MAddr. A. Sr. SAddr R. A. Data0. A. Data1. N. P Write Portion Read Portion A read transaction transfers 2 or more bytes from the MAX17040/MAX17041. Read transactions are composed of two parts, a write portion followed by a read portion, and are therefore inherently longer than a write transaction. The write portion communicates the starting point for the read operation. The read portion follows immediately, beginning with a Repeated START, Slave Address with R/W set to a 1. Control of SDA is assumed by the MAX17040/MAX17041, beginning with the Slave Address Acknowledge cycle. Control of the SDA signal is retained by the MAX17040/MAX17041 throughout the transaction, except for the acknowledge cycles. The master indicates the end of a read transaction by responding to the last byte it requires with a no acknowledge. This signals the MAX17040/MAX17041 that control of SDA is to remain with the master following the acknowledge clock. Write Data Protocol The write data protocol is used to write to register to the MAX17040/MAX17041 starting at memory address MAddr. Data0 represents the data written to MAddr, Data1 represents the data written to MAddr + 1, and DataN represents the last data byte, written to MAddr + N. The master indicates the end of a write transaction by sending a STOP or Repeated START after receiving the last Acknowledge bit: The MSB of the data to be stored at address MAddr can be written immediately after the MAddr byte is acknowledged. Because the address is automatically incremented after the LSB of each byte is received by the MAX17040/ MAX17041, the MSB of the data at address MAddr + 1 can be written immediately after the acknowledgment of the data at address MAddr. If the bus master continues an autoincremented write transaction beyond address 4Fh, the MAX17040/MAX17041 ignore the data. A valid write must include both register bytes. Data is also ignored on writes to read-only addresses. Incomplete bytes and bytes that are not acknowledged by the MAX17040/ MAX17041 are not written to memory. Read Data Protocol The read data protocol is used to read to register from the MAX17040/MAX17041 starting at the memory address specified by MAddr. Both register bytes must be read in the same transaction for the register data to be valid. Data0 represents the data byte in memory location MAddr, Data1 represents the data from MAddr + 1, and DataN represents the last byte read by the master: S. SAddr W. A. MAddr. A. Sr. SAddr R. A. Data0. A. Data1. A... DataN. N. P Data is returned beginning with the MSB of the data in MAddr. Because the address is automatically incremented after the LSB of each byte is returned, the MSB of the data at address MAddr + 1 is available to the host immediately after the acknowledgment of the data at address MAddr. If the bus master continues to read beyond address FFh, the MAX17040/MAX17041 output data values of FFh. Addresses labeled Reserved in the memory map return undefined data. The bus master terminates the read transaction at any byte boundary by issuing a no acknowledge followed by a STOP or Repeated START. S. SAddr W. A. MAddr. A. Data0. A. Data1. A... DataN. A. P www.maximintegrated.com Maxim Integrated 11 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Pin Configurations TOP VIEW SDA SCL 8 7 6 MAX17040 MAX17041 TOP VIEW BUMP SIDE DOWN EO SEO 5 1 2 3 A SDA SCL CTG B EO N.C. CELL C SEO VDD GND + MAX17040 MAX17041 + 1 2 3 4 CTG CELL VDD GND UCSP TDFN (2mm x 3mm) Package Information For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a "+", "#", or "-" in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE PACKAGE CODE OUTLINE NO. LAND PATTERN NO. 8 TDFN T823+1 21-0174 90-0091 9 UCSP W91C1+1 21-0459 Refer to Application Note 1891 www.maximintegrated.com Maxim Integrated 12 MAX17040/MAX17041 1-Cell/2-Cell Fuel Gauge with ModelGauge Revision History REVISION NUMBER REVISION DATE 0 7/08 Initial release 10/08 * Corrected the order of the pins in the Pin Configuration * Changed the max operating voltage from 5.5V to 4.5V * Inserted the "CELL Pin Input Impedance" specification into the DC Electrical Characteristics table * Corrected the order of the pins in the Pin Description table and changed the max operating voltage for the VDD pin 1, 2, 3, 5, 8 2 3/09 * Added the following sentence to the Registers section: "Register reads and writes are only valid if all 16 bits are transferred" * Added the following sentence to the Write Data Protocol section: "A valid write must include both register bytes" * Added the following sentence to the Read Data Protocol section: "Both register bytes must be read in the same transaction for the register data to be valid" 6, 11 3 4/10 Exposed pad connection to ground in Figures 5 and 6; corrected errors in specifications 1, 2, 7, 9, 13 4 8/10 Changed CELL pin external resistor value; added description and ordering information for UCSP package type 1, 2, 3, 5, 9, 12, 13 5 10/10 Updated Ordering Information table 6 8/11 Corrected time from start up until SOC valid; added text indicating accurate results require custom configuration for each application 7 6/12 Corrected soldering temperature in Absolute Maximum Ratings 8 8/12 Changed Soft POR command from 5400h to 0054h to avoid possible memory corruption 9 10/16 Updated title, General Description, Applications, and title of diagram 1 PAGES CHANGED DESCRIPTION -- 1, 2, 5, 12, 13 4, 6, 7, 13 2 6, 8, 13 1-13 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated's website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. (c) 2016 Maxim Integrated Products, Inc. 13 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Maxim Integrated: MAX17041X+T10 MAX17040G+T MAX17041G+T MAX17040X+T10 MAX17040X+U MAX17041X+ MAX17041G+U MAX17040G+U