100VAC Input/15VDC (80mA) Output
Non-Isolated AC/DC Converter
BP5034D15
Data Sheet
Absolute Maximum Ratings
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Parameter Symbol Limits Unit
Vi
Io
Vsurge
Topr
Tstg
195
80
2
20 to +80
30 to +85
V
mApk
kV
°C
°C
Unit
2
2
1
Conditions
V
V
mA
V
V
Vp-p
%
DC(80 to 138VAC)
Vi=141V, Io=80mA
Vi=141V
Vi=113 to 195V, Io=80mA
Vi=141V, Io=0 to 80mA
Vi=141V, Io=80mA
Vi=141V, Io=80mA
1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
2 Please refer to Load regulation, Conversion efficiency.
Electrical Characteristics
Input voltage range
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Power conversion efficiency
Parameter Symbol Typ. Max.Min.
Vi
Vo
Io
Vr
Vl
Vp
η
141
15.0
0.02
0.05
0.05
70
195
16.0
80
0.15
0.15
0.15
113
14.0
0
60
Load Regulation
Load Regulation
16.0
15.8
15.6
15.4
15.2
15.0
14.8
14.6
14.4
14.2
14.0
200 40 60 80
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Output Voltage Vo(V)
Conversion Efficiency
60% MinLine
Conversion Efficiency
80
70
60
50
40
30
20
10
0200 40 60 80
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Conversion Efficiency η(%)
Surface Temperature Increase
Surface Temperature Increase,
40
30
20
10
0200 40 60 80
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Temperature Rising T(°C)
Switching Frequency
Switching Frequency
120
100
80
60
40
20
0200 40 60 80
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Switching Frequency fsw(kHz)
Dimensions (Unit : mm)
Application Circuit
External Component Specifications
FUSE: Fuse
Use a quick-acting fuse of 0.5A
Capacitance : 3.3 to 22µF Rated voltage : 200V or higher
Ripple current is 0.13Arms or above.
Capacitance : 0.1 to 0.22µF Rated voltage : 200V or higher
Use a film or ceramic capacitor. Evaluate under actual operating
conditions.
C1: Input smoothing
capacitor
C2: Noise reduction
capacitor
Capacitance : 100 to 470µF Rated voltage : 25V or higher,
ESR is 0.39 max. Ripple current is 0.1Arms or above.
Evaluate under actual conditions.
C3: Output smoothing
capacitor
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectification can be used.)
D1: Rectifier diode
10 to 22 1/4W
Determine the ideal value through actual testing.
R1: Noise reduction
resistor
A varistor must be used to protect against lightning surges and static
electricity.
ZNR: Varistor
Pin No.
1
2
3
4
5
6
7
8
9
10
Function
Output terminal Vo(15V)
N.C.
N.C.
N.C.
COMMON
COMMON
N.C.
N.C.
Not used
Input terminal Vi(141VDC)
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
BP5034D15
Be sure to use fuse for safety.
15.7MAX.
Mark Side
4±1.0
28.2MAX. 10.0MAX.
3.5MAX.
6.5MAX.
2.549=22.86
1 2 3 4 5 6 7 8 10
0.5
±
0.1
P=2.54
±
0.2 1.3
±
0.2 0.25
±
0.05
3.25MAX
Derating Curve
Derating Curve
Operation Range
90
80
70
60
50
40
30
20
10
00 10-30-20 -10 20 4030 80706050 90
Ambient Temperature Ta(°C)
Output Current Io(mA)
Please note that pin No.10
side is input.
+15V
Output
Input
100µF/50V
AC100V
50Hz/60Hz 0.1µF
C2
FUSE
0.5A
110 8 7 6 5 4 3 2
+
+
10µF/250V
C1
ZNR
220V
R1
101/4W
D1
1SR139400
C3
100VAC Input/12VDC (100mA) Output
Non-Isolated AC/DC Converter
BP5034D12
Data Sheet
Application Circuit
Electrical Characteristics
Absolute Maximum Ratings
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Parameter Symbol Limits
Unit
Vi
Io
Vsurge
Topr
Tstg
195
100
2
25 to +80
25 to +105
V
mApk
kV
°C
°C
Unit
2
2
1
Conditions
V
V
mA
V
V
Vp-p
%
DC(80 to 138VAC level)
Vi=141V, Io=50mA
Vi=141V
Vi=113 to 195V, Io=50mA
Vi=141V, Io=0 to 50mA
Vi=141V, Io=50mA
Vi=141V, Io=100mA
1 The max output is changed due to the ambient temperature. Please refer to note regarding derating curve.
2 Please refer to Conversion efficiency.
Input voltage range
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Power conversion efficiency
Parameter Symbol Typ. Max.Min.
Vi
Vo
Io
Vr
Vl
Vp
η
141
12
0.02
0.05
0.05
68
195
12.8
100
0.1
0.15
0.15
113
11
0
60
Load Regulation
Load Regulation
13.0
12.8
12.6
12.4
12.2
12.0
11.8
11.6
11.4
11.2
11.0
200 40 60 80 100
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Output Voltage Vo(V)
Conversion Efficiency
60% MinLine
Conversion Efficiency
80
70
60
50
40
30
20
10
0200 40 60 80 100
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Conversion Efficiency (%)
Surface Temperature Increase
Surface Temperature Increase
40
30
20
10
0200 40 60 80 100
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Temperature Rising T(°C)
Switching Frequency
Switching Frequency
100
90
80
70
60
50
40
30
20
10
0200 40 60 80 100
(Ta=25°C, Vi=141V)
Output Current Io(mA)
Switching Frequency fsw(kHz)
Dimensions (Unit : mm)
External Component Specifications
FUSE: Fuse
Use a fuse of 0.5A
Capacitance : 3.3 to 22µF Ripple current is 0.13Arms or above.
Rated voltage : 200V or higher
Capacitance : 0.1 to 0.22µF Rated voltage : 200V or higher
Use a film or ceramic capacitor. Evaluate under actual operating conditions.
C1 : Input smoothing
capacitor
C2 : Noise reduction
capacitor
Capacitance : 100 to 470µF Rated voltage : 25V or higher, low impedance
Impedance is 0.39 max at high frequencies.
Ripple current is 0.1Arms or above.
Capacitance impedance affects the output ripple voltage.
C3 : Output smoothing
capacitor
In the absolute maximum ratings, the reverse surge voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the forward surge current should be 20A or higher.
D1 : Rectifier diode
10 to 22 1/4W
Determine the ideal value through actual testing.
R1 : Noise reduction
resistor
A varistor must be used to protect against lightning surges and static
electricity.
ZNR : Varistor
Pin No.
1
2
3
4
5
6
7
8
9
10
Terminal definition
Output terminal Vo(12V)
N.C.
N.C.
N.C.
COMMON
COMMON
N.C.
N.C.
Skipping Pin
Input terminal Vi(141VDC)
Please verify operation and characteristics in the customer's circuit before actual usage and
ensure that the load current does not exceed 0.1A.
BP5034D12
Be sure to use fuse for safety.
15.7MAX.
Mark Side
4±1.0
28.2MAX. 10.0MAX.
3.5MAX.
6.5MAX.
2.549=22.86
1 2 3 4 5 6 7 8 10
0.5±0.1
P=2.54±0.2 1.3±0.2 0.25± 0.05
3.25MAX.
Derating curve
Derating Curve
Operation Range
120
100
80
60
40
20
00 10-30-20 -10 20 4030 80706050 90
Ambient Temperature Ta(°C)
Output Current Io(mA)
Please note that pin No.10
side is input.
+12V
Output
Input
100µF/50V
AC100V
50Hz/60Hz 0.1µF
C2
FUSE
0.5A
110 8 7 6 5 4 3 2
+
+
10µF/250V
C1
ZNR
220V
R1
101/4W
D1
1SR35400A
C3
1/1 2010.01 - Rev.A
www.rohm.com
©2010 ROHM Co., Ltd. A l l ri ghts reserved.
R1010
A
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
Notice
ROHM Customer Support System
http://www.rohm.com/contact/
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specied herein is subject to change for improvement without notice.
The content specied herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specied in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specied herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specied in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, ofce-automation equipment, commu-
nication devices, electronic appliances and amusement devices).
The Products specied in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, re or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, re control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-
controller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specied herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.