Embedded Power for Business-Critical Continuity Rev. 08.28.12_141 LPT100-M Series 1 of 3 LPT100-M Series 130 Watts Total Power: Input Voltage: # of Outputs: 80 - 130 Watts 90 - 264 Vac Triple Special Features * * * * * * * * * * * * * Medical and ITE safeties Active power factor correction 2" x 4" footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection LPX50 enclosure kit available Electrical Specifications Input Input range: Frequency: Inrush current: Efficiency: EMI/RFI: Safety ground leakage current: 90 - 264 Vac; 127 - 300 Vdc 47 - 63 Hz 50 A max., cold start @ 25 C 82% typical at full load FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted 275 A @ 50/60 Hz, 264 Vac input Output Maximum power: 80 W for convection; 130 W with 200 LFM forced air Adjustment range: All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101-M +10%, -15% Hold-up time: 10 ms @ 130 W load, 120 Vac input Overload protection: Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3 Overvoltage protection: 15 - 35% above nominal output Logical Control Power failure: Safety * * * * * * * TUV 60950, 60601-1 UL 60950, 60601-1 CSA 60950, 60601-1 NEMKO 60950, 60601-1 AUSTEL 60950, 60601-1 CB Certificate & report CE Mark (LVD) Remote sense: Active LowTTL logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec before loss of regulation Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Environmental Specifications Rev. 08.28.12_141 LPT100-M Series 2 of 3 Operating temperature: Storage temperature: Electromagnetic susceptibility: 0 to 50 C ambient derate each output as 2.5% per degree from 50 to 70 C. -20 C start up -40 C to +85 C designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95% Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated: 583,000 hours at full load and 25 C ambient conditions. 230 Vac input, Bellcore Mechanical Drawing SK3 M1 1 1 GND LIVE (43.8) 1.72" NEUTRAL 1 SK1 8 SK3 3 Mounting Hole O0.16"[4.0] 4 Places 3.73" (94.7) Max. Screw Head Diameter .22" (5.6) 1.29" (32.7) 4.00" (101.6) 0.10" (2.5) max lead protrusion 2.00" (50.8) 4 SK2 0.197" (5.0) Minimum Standoff height Embedded Power for Business-Critical Continuity Americas Ordering Information Model Number Maximum Load Maximum Load Output Minimum with Convection with 30CFM Voltage Load Cooling Forced Air +3.3 V LPT101-M LPT102-M LPT103-M LPT104-M 0A 13 A 18 A Peak Load Regulation2 Ripple P/P (PARD)3 20 A 2% 50 mV +5 V 0A 5A 9A 10 A 5% 50 mV +12 V 0A 1A 2.3 A 2.3 A 5% 120 mV +5 V 0A 13 A 18 A 20 A 2% 50 mV +12 V 0A 5A 9A 10 A 5% 120 mV -12 V 0A 1A 2A 2A 5% 120 mV +5 V 0A 13 A 18 A 20 A 2% 50 mV +15 V 0A 4A 7.2 A 8A 5% 150 mV -15 V 0A 1A 1.5 A 2A 5% 150 mV +5 V 0A 13 A 18 A 20 A 2% 50 mV +24 V 0A 1.5 A 3A 3.5 A 7% 240 mV +12 V 0A 1A 2.3 A 2.3 A 5% 120 mV 1. Peak current lasting < 15 seconds with a maximum 10% duty cycle. Rev. 08.28.12_141 LPT100-M Series 3 of 3 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 2. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. For global contact, visit: 3. Peak-to-peak with 20 mHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. www.Emerson.com/EmbeddedPower Pin Assignments Connector SK1 PIN 1 PIN 3 SK2 PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 SK3 PIN 1 PIN 2 PIN 3 PIN 4 Mating Connectors LPT100-M Neutral Live V1out V1out GND GND GND GND V2out V3out Power Fail GND + Remote Sense - Remote Sense AC Input (SK1): Molex P/N 09-50-3031 PINS: 08-52-0072 AC Ground: Molex P/N 01-90020001 DC Output (SK2): JST P/N VHR-8N PINS: SVH-21T-P1.1 Remote Sense (SK3): Molex P/N 51065-0400 PINS: 50212-8100 Emerson Network Power Connector Kit #70-841-026, includes all of the above techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is .02". 3. All mounting holes should be grounded for EMI purpose 4. Mounting M1 is safety ground connection 5. Specifications are for convection rating at factory settings at 115 Vac input 25 C unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20" (5 m) in height. 7. For DC input an external DC safety rated fuse must be used. 8. Warranty: 2 year 9. Weight: 0.44 lb. / 0.20 kg Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson and the Emerson Network Power logo are trademarks of Emerson Electric Co. (c)2012 Emerson Electric Co. All rights reserved.