3
Electrical / Optical Characteristic at TA = 25°C
Red
Parameter Symbol Min Typ Max Units Test Conditions
Average Luminous Intensity (Digit Average) Iv–20 – mcdI
F = 10mA
Peak Wavelength Op– 640 – nm IF = 20mA
Dominant Wavelength Od– 626 – nm IF = 20mA
Forward Voltage per segment/DP VF– 8.0/4.0 9.2/4.6 V IF = 20mA
Reverse Current per segment/DP IR– – 100 PAVR = 20V/10V (DP)
Luminous Intensity Matching Ratio
(Segment to Segment)
Iv–M 2:1 IF = 10mA
Green
Parameter Symbol Min Typ Max Units Test Conditions
Average Luminous Intensity (Digit Average) Iv–28 – mcdI
F = 10mA
Peak Wavelength Op– 565 – nm IF = 20mA
Dominant Wavelength Od– 569 – nm IF = 20mA
Forward Voltage per segment/DP VF– 9.0/4.5 10/5 V IF = 20mA
Reverse Current per segment/DP IR– – 100 PAVR = 20V/10V (DP)
Luminous Intensity Matching Ratio
(Segment to Segment)
Iv–M 2:1 IF = 10mA
Yellow
Parameter Symbol Min Typ Max Units Test Conditions
Average Luminous Intensity (Digit Average) Iv–12 – mcdI
F = 10mA
Peak Wavelength Op– 587 – nm IF = 20mA
Dominant Wavelength Od– 589 – nm IF = 20mA
Forward Voltage per segment/DP VF– 8.6/4.3 9.2/4.6 V IF = 20mA
Reverse Current per segment/DP IR– – 100 PAVR = 20V/10V (DP)
Luminous Intensity Matching Ratio
(Segment to Segment)
Iv–M 2:1 IF = 10mA