FERROXCUBE DATA SHEET Cable shields EMI-suppression products Supersedes data of September 2004 2008 Sep 01 Ferroxcube EMI-suppression products Cable shields CABLE SHIELDS FOR EMI-SUPPRESSION Tubular cable shields D d handbook, halfpage L For dimensions see Table 1. CBW153 Fig.1 Tubular cable shield. Table 1 Type numbers, dimensions and parameters; see Fig.1 TYPE NUMBER CST7.8/5.3/9.8-3S4 CST8/5.3/10-3S4 CST8.3/3.5/10-3S4 CST9.5/4.8/4.8-4S2 CST9.5/4.8/6.4-4S2 CST9.5/4.8/9.5-4S2 CST9.5/4.8/10-4S2 CST9.5/4.8/13-4S2 CST9.5/4.8/19-4S2 CST9.5/5.1/15-3S4 CST9.5/5.1/15-4S2 CST9.7/5/5.1-4S2 CST14/6.4/5.3-4S2 CST14/6.4/10-4S2 CST14/6.4/14-4S2 CST14/6.4/15-4S2 CST14/6.4/29-4S2 CST14/7.3/29-4S2 CST16/7.9/14-4S2 CST16/7.9/29-4S2 CST17/9.5/13-3S4 CST17/9.5/13-4S2 2008 Sep 01 | Z typ |(1) () at DIMENSIONS D d L 7.8 0.2 8 -0.4 8.3 -0.4 9.5 0.25 9.5 0.25 9.5 0.25 9.5 0.25 9.5 0.25 9.5 0.25 9.5 0.3 9.5 0.3 9.65 0.25 14.3 0.45 14.3 0.45 14.3 0.45 14.3 0.45 14.3 0.45 14.3 0.45 16.25 -0.75 16.25 -0.75 17.45 0.35 17.45 0.4 5.3 +0.3 5.3 +0.3 3.5 +0.3 4.75 0.25 4.75 0.25 4.75 0.15 4.75 0.15 4.75 0.15 4.75 0.15 5.1 0.15 5.1 0.15 5 0.2 6.35 0.25 6.35 0.25 6.35 0.25 6.35 0.25 6.35 0.25 7.25 0.15 7.9 0.25 7.9 0.25 9.53 0.25 9.5 0.25 9.8 0.2 10 -0.4 10 -0.6 4.8 0.2 6.35 0.35 9.5 0.3 10.4 0.25 12.7 0.5 19.05 0.7 14.5 0.45 14.5 0.45 5.05 -0.45 5.3 -0.45 10.1 0.4 13.8 0.4 15 0.45 28.6 0.75 28.6 0.75 14.3 0.35 28.6 0.75 12.7 0.5 12.7 0.5 1381 25 MHz 33 36(2) 70 18 23 40 53 60 100 66 66 26 35 70 90 100 170 143 70 130 55 55 100 MHz 50 50 96 35 50 70 80 95 145 110 110 43 60 105 150 170 250 215 113 213 90 88 Ferroxcube EMI-suppression products TYPE NUMBER CST17/9.5/29-3S4 CST17/9.5/29-4S2 CST17/11/60-3S4 CST19/10/15-4S2 CST19/10/29-4S2 CST19/11/12-3S4 CST26/13/21-4S2 CST26/13/29-4S2 CST29/19/7.5-4S2 Cable shields D d L 17.45 0.35 17.45 0.35 17.2 -1.2 19 -0.65 19 -0.65 19 0.4 25.9 0.75 25.9 0.75 29 0.75 9.53 0.25 9.53 0.25 11 0.5 10.15 0.25 10.15 0.25 10.6 0.3 12.8 0.25 12.8 0.25 19 0.5 28.55 0.75 28.55 0.75 60 -2.5 14.65 -0.75 28.6 0.75 11.5 0.4 21.3 0.5 28.6 0.8 7.5 0.25 Note 1. Minimum guaranteed impedance is Ztyp -20%. 2. At 30 MHz. 2008 Sep 01 | Ztyp |(1) () at DIMENSIONS 1382 25 MHz 100 MHz 125 125 200 70 128 50 110 145 28 200 250 320 110 196 75 180 225 47 Ferroxcube EMI-suppression products Cable shields Round cable shields (split) A E handbook, halfpage A B C C handbook, halfpage D B CBW154 D CBW155 For dimensions see Table 2. For dimensions see Table 2. Fig.3 Nylon case. Fig.2 Shield (CSA) outline. handbook, halfpage D C CE handbook, halfpage A B A B CBW156 D CBW157 For dimensions see Table 2. For dimensions see Table 2. Fig.4 Shield (CSC) outline. 2008 Sep 01 Fig.5 Nylon case. 1383 Ferroxcube EMI-suppression products Cable shields General data ITEM SPECIFICATION Case material polyamide (PA66), glass reinforced, flame retardant in accordance with "UL94V-0" , grade A82, colour black Table 2 Type numbers, dimensions and parameters; see Figs 2 to 5 | Ztyp |(1) () at DIMENSIONS TYPE NUMBER FIG. A B C D E 25 MHz 100 MHz Round cable shields CSA15/7.5/29-4S2 2 CSA19/9.4/29-4S2 2 15 0.25 6.6 0.3 28.6 0.8 7.5 0.15 - 165 275 18.65 0.4 10.15 0.3 28.6 0.8 9.4 0.15 - 140 225 CSA26/13/29-4S2 2 25.9 0.5 13.05 0.3 28.6 0.8 12.8 0.25 - 155 250 CSC16/7.9/14-4S2 4 15.9 0.4 7.9 0.3 14.3 0.4 7.95 0.2 - 50 113 7.0 32.3 165 275 Round cable shields in matching nylon cases CSA15/7.5/29-4S2-EN Nylon case CSA19/9.4/29-4S2-EN Nylon case CSA26/13/29-4S2-EN Nylon case CSC16/7.9/14-4S2-EN Nylon case 2+3 17.9 9.0 3 17.9 7.0 32.3 9.2 9.0 - - 2+3 22.1 10.2 32.3 11.7 9.0 140 225 3 22.1 10.2 32.3 11.7 9.0 - - 2+3 29 13.4 32.5 14.8 18.0 155 250 3 29 13.4 32.5 14.8 18.0 - - 4+5 24.7 7.6 22.8 10.2 17.8 50 5 24.7 7.6 22.8 10.2 17.8 - Note 1. Minimum guaranteed impedance is Ztyp -20%. 2008 Sep 01 9.2 1384 113 - Ferroxcube EMI-suppression products Cable shields Flat cable shields (split) D D C C E B A C A D handbook, halfpage A B E B E MFP074 a. b. For dimensions see Table 3. Fig.6 Outlines of flat cable shields (split) and accessories. 2008 Sep 01 1385 c. Ferroxcube EMI-suppression products Cable shields General data ITEM SPECIFICATION Case material polyamide (PA66), glass reinforced, flame retardant in accordance with "UL94V-0" , grade A82, colour black Clip material Table 3 spring steel (0.5 mm), zinc plated Type numbers, dimensions and parameters; see Fig.6 TYPE NUMBER FIG. | Ztyp |(1) () at DIMENSIONS A B C D E 25 MHz 100 MHz Flat cable shields (split) CSU45/6.4/29-4S2 6a 45.1 0.75 34.4 0.7 28.6 0.7 6.35 0.25 0.85 0.2 96 225 CSU76/6.4/13-3S4 6a 76.2 1.5 65.3 1.3 12.7 0.4 6.35 0.25 0.85 0.2 36 110 CSU76/6.4/15-3S4 6a 76.2 1.5 65.3 1.3 15.0 0.6 6.35 0.25 0.85 0.2 50 159 CSU76/6.4/29-4S2 6a 76.2 1.5 65.3 1.3 28.6 0.8 6.35 0.25 0.85 0.2 75 215 CSU76/6.4/29-3S4 6a 76.2 1.5 65.3 1.3 28.6 0.8 6.35 0.25 0.85 0.2 CLI-CSU6.4 6c 16.1 70 235 11.0 12.7 11.4 8.0 - - 96 225 Flat cable shields in matching nylon cases CSU45/6.4/29-4S2-EN Nylon case CSU76/6.4/29-4S2-EN Nylon case 6a+b 49.5 34.3 32.3 8.1 20 6b 49.5 34.3 32.3 8.1 20 - - 6a+b 80.8 65.5 32.3 8.1 50.8 75 215 6b 80.8 65.5 32.3 8.1 50.8 - - Note 1. Minimum guaranteed impedance is Ztyp -20%. 2008 Sep 01 1386 Ferroxcube EMI-suppression products Cable shields Flat cable shields A A D handbook, halfpage A handbook, halfpage C B A D C B E E CBW161 CBW162 A-A For dimensions see Table 4. For dimensions see Table 4. Fig.7 CSF38/12/25 outline. Table 4 Fig.8 CSF38/12/25-S outline. Type numbers, dimensions and parameters; see Figs 7 and 8 TYPE NUMBER | Ztyp |(1) () at DIMENSIONS FIG. A B C D E 25 MHz 100 MHz Flat cable shields CSF38/12/25-3S4 7 38.1 1.0 12.1 0.35 25.4 0.75 26.7 0.75 1.9 0.35 CSF38/12/25-3S4-S 8 38.5 0.6 12.1 0.4 Note 1. Minimum guaranteed impedance is Ztyp -20%. 2008 Sep 01 1387 25.4 0.8 26.8 0.8 1.9 0.4 110 215 98 196 Ferroxcube EMI-suppression products Cable shields DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS PRODUCT STATUS DEFINITIONS Preliminary specification Development This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS INDICATION DEFINITION Prototype These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. Design-in These products are recommended for new designs. Preferred These products are recommended for use in current designs and are available via our sales channels. Support These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability. 2008 Sep 01 1388