DC/DC CONVERTERS 36-100 W High Efficiency DC/DC Converters 1
2 YEAR WARRANTY
EXQ125 Series
Single output
Ultra-high efficiency topology, 91% at 3.3 V,
88% typical at 1.8 V
Industry standard footprint
Wide baseplate temperature, -40 °C to +100 °C
90% to 110% output trim
No minimum load
Overvoltage protection
Remote ON/OFF
Available RoHS compliant
The EXQ125 is a new ultra high efficiency, open-frame, isolated converter series in
an industry standard quarter-brick footprint that provides up to 100 Watts of output
power. The EXQ125 delivers very high output current at low voltages, and excellent
useable power density for today’s high end applications. The seven models in the
series feature an input voltage range of 33 Vdc to 75 Vdc and are available in output
voltages of 12 V, 5 V, 3.3 V, 2.5 V, 1.8 V, 1.5 V and 1.2 V. The output voltage on each
model is adjustable from 90% to 110% of the nominal value. The EXQ125 series
also has a remote ON/OFF capability. Overcurrent and overvoltage protection
features are included as standard. With full international safety approval including
EN60950 (TÜV Rheinland) and UL/cUL1950, the EXQ125 reduces compliance costs
and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC CHARACTERISTICS
Conducted emissions EN55022 (See Note 2) Level A
EN55022 (See Note 2) Level B
Radiated emissions EN55022 Level B
Immunity:
ESD air EN61000-4-2 8 kV (NP), 15 kV (NP)
ESD contact EN61000-4-2 6 kV (NP), 8 kV (NP)
Radiated field enclosure EN61000-4-3 10 V/m (NP)
Conducted (DC power) EN61000-4-6 10 V (NP)
Conducted (signal) EN61000-4-6 10 V (NP)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Operational Input/output 1500 Vdc
Input/baseplate 1500 Vdc
Switching frequency Fixed 400 kHz typ.
Approvals and EN60950 (TÜV Rheinland)
standards (See Note 4) UL/cUL1950
Material flammability UL94V-0
Weight 45 g (1.6 oz)
MTBF Telcordia SR-332 2,284,281 hours
@ 25 °C, 100% load
ground benign
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating baseplate -40 °C to +100 °C
temperature
Non-operating -40 °C to +125 °C
OUTPUT SPECIFICATIONS
Voltage adjustability 90% to 110%
Set point accuracy ±1.5% max.
Line regulation Low line to high line ±0.1% max.
Load regulation Full load to min. load 0.2% max.
Minimum load 0 A
Overshoot At turn-on and turn-off None
Undershoot 1.2 V, 1.5 V (Z), 1.8 V (Z), None
2.5 V (Z) and 3.3 V (Z) models
Ripple and noise 5 Hz to 20 MHz 60 mV pk-pk
20 mV rms
Transient response 2% typ. deviation
(See Note 1) 100 µs recovery to
within 1% of setpoint
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 33-75 Vdc
Input current No load 85 mA
Remote OFF 20 mA
Input current (max.) 3.5 A max. @ Io max.
(See Note 3) and Vin = 33-75 Vdc
Input reflected ripple (See Note 5) 300 mA (pk-pk) typ.
Active high remote ON/OFF
Logic compatibility Open collector ref to -input
ON Open circuit or >4.0 Vdc
OFF <1.2 Vdc
Undervoltage lockout Power up 32.5 V (typ)
Power down 30.5 V (typ)
Start-up time Power up 6 ms (typ)
(See Note 6) Remote ON/OFF 2 ms (typ)
SPECIFICATIONS
File Name: exq125s.pdf Rev (02): 17 Nov 2005
TÜV
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Notes
1di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max. Deviation varies by model, see
Longform Datasheet.
2The EXQ125 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 118.
3Recommended input fusing is a 5 A HRC 200 V rated fuse.
4This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
5Measured with no external Pi filter. Significant reduction possible with
external filter. See Application Note 118.
6Start-up into resistive load.
7Contact the factory for Modified Standard pin length products.
8TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
9NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
Short circuit Continuous
Overvoltage Non-latching clamp
TELECOM SPECIFICATION
Central office interface A ETS300-132-2, input voltage
and current requirements
EXQ125 Series
Single output
DC/DC CONVERTERS 36-100 W High Efficiency DC/DC Converters 2
File Name: exq125s.pdf Rev (02): 17 Nov 2005
OUTPUT INPUT OVP OUTPUT OUTPUT OUTPUT EFFICIENCY REGULATION MODEL
POWER VOLTAGE VOLTAGE CURRENT CURRENT (TYP.) LINE LOAD NUMBER (8,9)
(MAX.) (MIN.) (MAX.)
36 W 33-75 Vdc 1.45 Vdc 1.2 V 0 A 30 A 86.5% ±0.1% ±0.2% EXQ125-48S1V2J
45 W 33-75 Vdc 1.8 Vdc 1.5 V 0 A 30 A 87.5% ±0.1% ±0.2% EXQ125-48S1V5J
54 W 33-75 Vdc 2.3 Vdc 1.8 V 0 A 30 A 88.0% ±0.1% ±0.2% EXQ125-48S1V8J
75 W 33-75 Vdc 3 Vdc 2.5 V 0 A 30 A 90.0% ±0.1% ±0.2% EXQ125-48S2V5J
82.5 W 33-75 Vdc 3.9 Vdc 3.3 V 0 A 25 A 91.0% ±0.1% ±0.2% EXQ125-48S3V3J
100 W 33-75 Vdc 6 Vdc 5 V 0 A 20 A 92.0% ±0.1% ±0.2% EXQ125-48S05J
100 W 33-75 Vdc 14.4 Vdc 12 V 0 A 8.3 A 93.0% ±0.1% ±0.2% EXQ125-48S12J
EXQ125-48S1V2-ZRNJ
Part Number System with Options
EX = Open Frame, Through Hole
Q= 1/4 Brick
Output Wattage Class
125 = 125 Watts
Input Voltage
48 = 48 Volts (33 V to 75 V range)
Number of Outputs
S = Single
Pin Length of Standard Product
Blank = 0.200” (5.08 mm)
Pin Length of Modified Standard Product
N = 0.145” (3.68 mm)
K = 0.110” (2.79 mm)
(See Note 7)
Control Logic
Blank = Positive
R = Negative
Blank = Standard Product
Z= Zero Undershoot,
Soft Turn-off Characteristic
(Applies to 1.5 V, 1.8 V,
2.5 V and 3.3 V models only)
Output Voltage
1V2 = 1.2 V, 1V5 = 1.5 V etc
RoHS Compliance (8)
J = Pb-free (RoHS 6/6 compliant)
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
PIN CONNECTIONS
PIN NUMBER FUNCTION
1+Vin
2On/Off
3-Vin
4-Vout
5-Sense
6Trim
7+Sense
8+Vout
EXQ125 Series
Single output
DC/DC CONVERTERS 36-100 W High Efficiency DC/DC Converters 2
Please consult our website for the following items: Application Note Longform Data Sheet www.artesyn.com
File Name: exq125s.pdf Rev (02): 17 Nov 2005
ALL DIMENSIONS IN INCHES [mm]
Recommended
Hole Pattern
M3 x 0.5 Threaded
Through (4 PLS)
Ø0.128 [Ø3.25]
(4 PLS)
Ø0.073 [Ø1.85]
(2 PLS)
0.000 [0.00]
0.215 [5.46]
0.070 [1.78]
0.070
[1.78]
0.365 [9.27]
0.515 [13.08]
0.665 [16.89]
0.815 [20.70]
0.50 [12.70]
0.215 [5.4 ]
0.515 [13.08 ]
0.815 [20.70 ]
*
0.20 [5.08]
1
2
34
5
6
7
8
0.000 [0.00]
0.215 [5.46]
0.365 [9.27]
0.515 [13.08]
0.665 [16.89]
0.815 [20.70]
0.215 [5.36 ]
0.515 [13.8 ]
0.815 [20.70]
1.030 [26.16]
0.000 [0.00]
3
2
18
7
6
5
4
Ø0.040 [Ø1.09]
(6 PLS)
Ø0.060 [Ø1.52]
(2 PLS)
2.000 [50.80]
2.280 [57.91]
1.860 [47.24]
0.210 [5.33]
0.210 [5.33]
1.450
[36.83]
1.030
[26.16]
Bottom View
Top View
*Standard available pin length.
0.145 (3.68) and 0.110 (2.79)
options also available. (See
Notes 8 and 9 for ordering details)
International Safety Standard Approvals
UL/cUL : UL1950 File No. E135734
TÜV TÜV Rheinland Certificate No. R72050216
CB Scheme No. US-TUVR-2217