CSRT = (tRP - 275µs) / (2.73 5 106)
where tRP is in seconds and CSRT is in farads.
The reset delay time is set by a current/capacitor-con-
trolled ramp compared to an internal 0.65V reference. An
internal 240nA ramp current source charges the external
capacitor. The charge to the capacitor is cleared when a
reset condition is detected. Once the reset condition is
removed, the voltage on the capacitor ramps according to
the formula: dV/dt = I/C. The CSRT capacitor must ramp to
0.65V to deassert the reset. CSRT must be a low-leakage
(<10nA) type capacitor; ceramic is recommended.
Operating as a Voltage Detector
The MAX6340/MAX6421–MAX6426 can be operated in
a voltage detector mode by floating the SRT pin. The
reset delay times for VCC rising above or falling below the
threshold are not significantly different. The reset output
is deasserted smoothly without false pulses.
Applications Information
Interfacing to Other Voltages for Logic
Compatibility
The open-drain outputs of the MAX6340/MAX6423/
MAX6425/MAX6426 can be used to interface to µPs with
other logic levels. As shown in Figure 1, the open-drain
output can be connected to voltages from 0 to 5.5V. This
allows for easy logic compatibility to various µPs.
Wired-OR Reset
To allow auxiliary circuitry to hold the system in reset,
an external open-drain logic signal can be connected
to the open-drain RESET of the MAX6340/MAX6423/
MAX6425/MAX6426, as shown in Figure 2. This config-
uration can reset the µP, but does not provide the reset
timeout when the external logic signal is released.
Negative-Going VCC Transients
In addition to issuing a reset to the µP during power-up,
power-down, and brownout conditions, these supervisors
are relatively immune to short-duration negative-go-
ing transients (glitches). The graph Maximum Transient
Duration vs. Reset Threshold Overdrive in the Typical
Operating Characteristics shows this relationship.
The area below the curve of the graph is the region in
which these devices typically do not generate a reset
pulse. This graph was generated using a negative-going
pulse applied to VCC, starting above the actual reset
threshold (VTH) and ending below it by the magnitude
indicated (reset-threshold overdrive). As the magnitude of
the transient decreases (farther below the reset thresh-
old), the maximum allowable pulse width decreases.
Typically, a VCC transient that goes 100mV below the
reset threshold and lasts 50µs or less does not cause a
reset pulse to be issued.
Ensuring a Valid RESET or RESET
Down to VCC = 0
When VCC falls below 1V, RESET/RESET current-sinking
(sourcing) capabilities decline drastically. In the case of
the MAX6421/MAX6424, high-impedance CMOS-logic
inputs connected to RESET can drift to undetermined
voltages. This presents no problems in most applications,
since most µPs and other circuitry do not operate with
VCC below 1V.
In those applications where RESET must be valid down
to zero, adding a pulldown resistor between RESET
and ground sinks any stray leakage currents, holding
RESET low (Figure 3). The value of the pulldown resis-
tor is not critical; 100kΩ is large enough not to load
RESET and small enough to pull RESET to ground. For
applications using the MAX6422, a 100kΩ pullup resis-
Figure 2. Wired-OR Reset Circuit
VDD
VCC
MAX6340
MAX6423
MAX6425
MAX6426
RESET
N
N
GND
OPEN-DRAIN
LOGIC
µP
RESET
10kΩ
www.maximintegrated.com Maxim Integrated
│
5
MAX6340/MAX6421–
MAX6426
Low-Power, SC70/SOT µP Reset Circuits
with Capacitor-Adjustable Reset Timeout Delay