I~
1.
937
_
MAX
250
DIA
.138-32
UNC-28
.188
DEEP
2
PLACES
L
~-<w+----->-
641
60
1.
562
MAX
8"-14~8"-14"
LOCK
RING
IF
NEEDED
ISEE
NOTE
91
.380
.332
If
1.828
MAX
INTERNAL
TOOTH
LDCKWASHER
ISEE
NOTE
61
PANEL
SEAL
"0"-RING
.
610
DIA
-+---i-o-+--i
MAX
J
..
i
I
MARKING
_
_,,..__
........
__
1,--_--.1,,........1
-1--1SEE
NOTE
Bl
MIN
.906
MAX
I'--
MAIN TERMINAL
.
2501-
MIN
A . 62 .
625
A
t ----------t
VIEW
A-A
CONFIGURATION 1
MIL-PRF-39019/6H
14 May 2010
SUPERSEDING
MIL-PRF-39019/6G
27 August 1997
PERFORMANCE SPECIFICATION SHEET
CIRCUIT BREAKERS, MAGNETIC, LOW-POWER, SEALED, TRIP-FREE
THREE-POLE, AUXILIARY CONTACTS
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall consist of
this specification sheet and MIL-PRF-39019.
(SEE NOTE 11)
(SEE NOTE 13)
C
3 AUXILARY
NC
CONTACT TERMINALS
NO
(SEE NOTE 14)
FIGURE 1. Circuit breaker configuration.
AMSC N/A FSC 5925
r
1-------'Y
...+-..
~'----------,
1.937
L
~
-l
+
-~:
~
1.
5
8•-14~
HEX
N
CSE
ON-OFF
PLATE
LOCK
RING------~-~-~-~'+7
IF
NEEDED
(SEE
NOTE
9)
.
610
DIA
-+----.----,
MAX
LOAD
.250
MIN
1
1
3
15
1
c
;Jl,tt~\
LINE
CIRCUIT
DIAGRAM
(MAIN
CONTACTS
OPEN)
SEE
NOTE
10
.250
DIA
.138-32
UNC-2B
.188
DEEP
2
PLACES
KEYWAY
------,.,
.
063
•.
005
WIDE
950
X
.
030
•.
005
DEEP
MARKING
EE
NOTE
MAIN
TERMINALS
SEE
NOTE
13
~
INSULATING
L_J
BLOCK
(SEE
NOTE
15)
A
___________________
j
.138-32 X .250
SCREW
CNO.
6
LOCKWASHERl
SEE
NOTE
15
3
AUX
CONTACT
TERMINALS
(SEE
NOTE
14)
CONFIGURATION
2
VIEW
A-A
MIL-PRF-39019/6H
FIGURE 1. Circuit breaker configuration -Continued.
2
~
.687
•.005
,,-
I \
•.
005
./"":"
.140
DIA
.687;1-
/'-
'<
:t,005
.125
•.
005 DIA
. 062 HIN
DEPTH
391 DIA
•.005
.625
•.005
PANEL
MOUNTING
DETAIL
MIL-PRF-39019/6H
Inches mm Inches mm Inches mm Inches mm Inches mm
.005 0.13 .125 3.18 .325 8.26 .392 9.96 .687 17.45
.015 0.38 .138 3.51 .332 8.43 .493 12.52 .906 23.01
.030 0.76 .140 3.56 .375 9.52 .507 12.88 1.562 39.67
.060 1.52 .188 4.78 .380 9.65 .610 15.49 1.828 46.43
.062 1.57 .240 6.10 .382 9.70 .625 15.88 1.937 49.20
.063 1.60 .250 6.35 .391 9.93 .641 16.28 1.950 49.53
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ±.031 (0.79 mm).
4. The shape of the circuit breaker is shown for information only. Slight deviations from this outline drawing,
which do not alter the functional aspect of the device, are acceptable.
5. Hex mounting nut .375-32 UNEF-2B thread, .093 ±.005 (2.36 ±0.13 mm) thick or equivalent MS25082-20,
-B20.
6. Internal tooth lockwasher, .507/.493 O.D., .392/.382 I.D., .025 ±.005 (0.64 ±0.13mm) thick, stainless steel or
equivalent MS35333-134.
7. The effective bushing thread length (not including mounting hardware) is .280 (7.11 mm) minimum.
8. Marking may appear on any surface except the mounting surface.
9. Lock ring not required if on-off plate has locking tab.
10. Numerical marking optional on circuit diagram.
11. Sealscrew, .138-32 UNC-2A x .312 (7.92 mm) long, stainless steel number 18-8 (type 347) MS35265-25 or
equivalent with appropriate O-rings. O-rings should be chosen to enable the circuit breaker to meet the
performance requirements of this specification. Possible source: AMP Hexseal Corporation.
12. Use of panel screws will enhance circuit breaker shock and vibration characteristics.
13. Threaded inserts exceed height of bushing by .005 to .015 (0.13 mm to 0.38 mm).
14. Auxiliary contact terminals shall be located on the back side of the circuit breaker (same surface as main
terminals), but otherwise their location, style, and form shall be optional, consistent with dimensional or other
specified requirements. Auxiliary contact terminals shall accommodate two number 20 AWG wires.
15. For configuration 2 add "S" at end of dash number for screw terminals with insulating block (see table I).
When circuit breakers are subjected to the resistance to solvents test, the insulating block shall be removed
and shall not be tested. Main terminal screw MS35265-26 or equivalent.
FIGURE 1. Circuit breaker configuration -Continued.
3
MIL-PRF-39019/6H
REQUIREMENTS:
Dimensions and configuration: See figure 1 and note 15.
Weight: For reference only, approximately 150 grams.
Mounting hardware: See figure 1.
Terminals: See figure 1.
Voltage and frequency rating: 50 V dc, maximum and 240 V ac, maximum at 60 Hz and 400 Hz.
High inrush: 800 percent at 60 Hz and dc, 1,400 percent at 400 Hz (see table I).
Current rating: See table I.
Circuit diagram: See figure 1.
Time delay: See table I.
Resistance or impedance: See table I.
Part or Identifying Number (PIN): The PIN shall be M39019/06-(dash number taken from table I) (e.g.,
M39019/06-200, M39019/06-200S).
Cross reference: See table II.
TABLE I. Circuit breaker dash numbers and applicable characteristics.
Dash number 1/ Current
rating
(amps)
Time delay Resistance or impedance
(ohms -max) 2/
Standard
delay
High
inrush
DC
60 Hz
400 Hz
200
300
0.05
A
680.0
690.0
710.0
201 301 0.05 B 680.0 690.0 710.0
202 --- 0.05 C 680.0 690.0 710.0
203 302 0.1 A 150.0 170.0 180.0
204 303 0.1 B 150.0 170.0 180.0
205
---
0.1
C
150.0
170.0
180.0
206
304
0.25
A
20.0
26.0
27.0
207 305 0.25 B 20.0 26.0 27.0
208 --- 0.25 C 20.0 26.0 27.0
209 306 0.5 A 5.4 6.0 6.6
210
307
0.5
B
5.4
6.0
6.6
211
---
0.5
C
5.4
6.0
6.6
212 308 0.75 A 2.5 2.7 2.8
213 309 0.75 B 2.5 2.7 2.8
214 --- 0.75 C 2.5 2.7 2.8
215
310
1.0
A
1.35
1.5
1.61
See footnotes at end of table.
4
MIL-PRF-39019/6H
TABLE I. Circuit breaker dash numbers and applicable characteristics -Continued.
Dash number 1/
Current
rating
(amps)
Time delay
Resistance or impedance (ohms -max) 2/
Standard
delay
High
inrush
DC
60 Hz
400 Hz
216
311
1.0
B
1.35
1.5
1.61
217 --- 1.0 C 1.35 1.5 1.61
218 312 2.0 A 0.40 0.40 0.50
219 313 2.0 B 0.40 0.40 0.50
220
---
2.0
C
0.40
0.40
0.50
221 314 2.5 A 0.25 0.25 0.27
222 315 2.5 B 0.25 0.25 0.27
223 --- 2.5 C 0.25 0.25 0.27
224 316 3.0 A 0.15 0.15 0.17
225
317
3.0
B
0.15
0.15
0.17
226
---
3.0
C
0.15
0.15
0.17
227 318 4.0 A 0.10 0.10 0.12
228 319 4.0 B 0.10 0.10 0.12
229 --- 4.0 C 0.10 0.10 0.12
230
320
5.0
A
0.061
0.063
0.072
231
321
5.0
B
0.061
0.063
0.072
232 --- 5 .0 C 0.061 0.063 0.072
233 322 6.0 A 0.042 0.043 0.050
234 323 6.0 B 0.042 0.043 0.050
235
---
6.0
C
0.042
0.043
0.050
236
324
7.0
A
0.036
0.036
0.040
237 325 7.0 B 0.036 0.036 0.040
238 --- 7.0 C 0.036 0.036 0.040
239 326 7.5 A 0.031 0.031 0.038
240
327
7.5
B
0.031
0.031
0.038
241
---
7.5
C
0.031
0.031
0.038
242 328 8.0 A 0.027 0.028 0.035
243 329 8.0 B 0.027 0.028 0.035
244 --- 8.0 C 0.027 0.028 0.035
245
330
9.0
A
0.022
0.022
0.028
246
331
9.0
B
0.022
0.022
0.028
247 --- 9 .0 C 0.022 0.022 0.028
248 332 10.0 A 0.018 0.021 0.024
249 333 10.0 B 0.018 0.021 0.024
250
---
10.0
C
0.018
0.021
0.024
See footnotes at end of table.
5
MIL-PRF-39019/6H
TABLE I. Circuit breaker dash numbers and applicable characteristics -Continued.
Dash number 1/
Current
rating
(amps)
Time delay
Resistance or impedance
(ohms -max) 2/
Standard
delay
High
inrush
DC
60 Hz
400 Hz
251
334
12.5
A
0.012
0.013
0.015
252 335 12.5 B 0.012 0.013 0.015
253 --- 12.5 C 0.012 0.013 0.015
254 336 15.0 A 0.009 0.009 0.010
255
337
15.0
B
0.009
0.009
0.010
256 --- 15.0 C 0.009 0.009 0.010
257 338 20.0 A 0.006 0.006 0.007
258 339 20.0 B 0.006 0.006 0.007
259 --- 20.0 C 0.006 0.006 0.007
260
340
1.25
A
0.9
1.0
1.1
261
341
1.25
B
0.9
1.0
1.1
262 --- 1.25 C 0.9 1.0 1.1
263 342 1.5 A 0.65 0.70 0.75
264 343 1.5 B 0.65 0.70 0.75
265
---
1.5
C
0.65
0.70
0.75
1/ For configuration 2, add "S" at end of dash number.
2/ The corresponding maximum wattage losses, which in no case shall exceed 3.0 watts, may be calculated as
I2R or I2Z.
6
MIL-PRF-39019/6H
TABLE II. Cross reference of superseded part numbers.
Superseded
New
Superseded
New
Superseded
New
MIL-C-39019/6B part number MIL-C-39019/6B part number MIL-C-39019/6B part number
part number M39019/06-part number M39019/06-part number M39019/06-
M39019/6-
M39019/6-
M39019/6-
1
200
41
230
81
218
2 201 42 231 82 219
3 200 43 230 83 218
4 201 44 231 84 219
5 200 45 230 85 218
6 201 46 231 86 219
7 200 47 230 87 227
8 201 48 231 88 228
9 200 49 230 89 227
10 201 50 231 90 228
11 209 51 248 91 227
12 210 52 249 92 228
13 209 53 248 93 233
14 210 54 249 94 234
15 209 55 248 95 233
16 210 56 249 96 234
17 209 57 248 97 233
18 210 58 249 98 234
19 209 59 248 99 236
20 210 60 249 100 237
21 215 61 254 101 236
22 216 62 255 102 237
23 215 63 254 103 236
24 216 64 255 104 237
25 215 65 254 105 242
26 216 66 255 106 243
27 215 67 254 107 242
28 216 68 255 108 243
29 215 69 254 109 242
30 216 70 255 110 243
31 224 71 257 111 245
32 225 72 258 112 246
33 224 73 257 113 245
34 225 74 258 114 246
35 224 75 257 115 245
36 225 76 258 116 246
37 224 77 257 117 251
38 225 78 258 118 252
39 224 79 257 119 251
40 225 80 258 120 252
121 251
122
252
7
MIL-PRF-39019/6H
The margins of this specification are marked with vertical lines to indicate where changes from the previous issue
were made. This was done as a convenience only and the Government assumes no liability whatsoever for any
inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this
document based on the entire content irrespective of the marginal notations and relationship to the last previous
issue.
Custodians: Preparing activity:
Army - CR Army - CR
Navy - EC
Air Force -85 Agent:
DLA -CC DLA -CC
Review activities: (Project 5925-2009-037)
Army - AT, AV, MI
Navy -AS, MC
Air Force -19, 99
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.daps.dla.mil.
8