BUSSMANN Technical Data 720099 Effective October 2017 Supersedes September 2015 SERIES 400 Volts gG/gL NH Fuse links Product description Eaton's Bussmann(R) series 400 V a.c. NH square bodied industrial fuse links are suitable for a wide variety of applications. Standard features * Reliable dual indicator system * Low temperature rise * Globally compliant * Compatible with Eaton's Bussmann series NH bases and NH Fuse gear Technical Data 720099 400 Volts gG/gL NH Fuse links Effective October 2017 Catalogue symbol: Microswitches * (amp)NHG(size)B-400 with conducting metal gripping lugs * (amp(NHG(size)BI-400 with insulated metal gripping lugs Fuse body size: 000 to 3 * Technical data: Volts: 400 V a.c. * * Amps: 2 to 630 A * Breaking capacity: 120 kA AC * Operating frequency: 45-62 Hz * Class of operation: gG/gL NH Fuse link body size Suitable microswitch 000 170H0236 00 170H0236 01 170H0235 1 170H0236 02 BVL50 2 170H0235 or 170H0236 03 BVL50 3 170H0235 Compatible fuse holders and fuse gear Description Standards/Approvals: Type Fuse bases 1-pole Data sheet number DIN-Rail mounting SD-D 10163 Screw mounting SD-S 10163 * IEC 60269 * VDE 0636 Fuse bases 3-pole DIN-Rail mounting TD-D 10163 * DIN 43620 Fuse bases accessories 10163 * CE IP20, Shroud and phase barriers kits Fuse rails Vertical EBF 10240 Fuse switch disconnectors Vertical EBV 10275 Horizontal - EBH size 000 10292 Horizontal - EBH sizes 00 to 4 10293 Packaging: Sizes 000 to 3: 3 per carton * Size - mm Table 1. NH Sizes Size a1 a2 (max) a3 a4 b c1 c2 d e1 (max) e2 (max) e3 (max) e4 f (max) 000 78.5 1.5 54 451.5 491.5 15 35 10 20.5 41 21 16 6 8 00 78.5 1.5 54 451.5 491.5 15 35 11 20.5 48 30 25 6 15 01 1352.5 75 622.5 682.5 15 40 11 2.50.5 48 30 25 6 15 1 1352.5 75 622.5 682.5 20 40 11 2.50.5 53 40 25 6 15 02 1502.5 75 622.5 682.5- 20 48 11 2.50.5 53 40 25 6 15 2 1502.5 75 622.5 682.5 25 48 11 2.50.5 61 53 25 6 15 03 1502.5 75 622.5 682.5 25 60 11 2.50.5 61 53 25 6 15 3 1502.5 75 622.5 682.5 32 60 11 30.5 75 70 25 6 18 2 EATON www.eaton.com Technical Data 720099 400 Volts gG/gL NH Fuse links Effective October 2017 Table 2. Part numbers Size 000 00 01 1 02 2 03 3 Rated current (Amps) 2 4 6 10 16 20 25 32 35 40 50 63 80 100 125 160 35 40 50 63 80 100 125 160 200 224 250 35 40 50 63 80 100 125 160 200 224 250 315 355 400 630 250 315 355 400 500 630 Rated voltage (V a.c.) 400 gG/gL dual indicator Voltage conducting metal gripping lugs 2NHG000B-400 4NHG000B-400 6NHG000B-400 10NHG000B-400 16NHG000B-400 20NHG000B-400 25NHG000B-400 32NHG000B-400 35NHG000B-400 40NHG000B-400 50NHG000B-400 63NHG000B-400 80NHG000B-400 100NHG000B-400 125NHG00B-400 160NHG00B-400 35NHG01B-400 40NHG01B-400 50NHG01B-400 63NHG01B-400 80NHG01B-400 100NHG01B-400 125NHG01B-400 160NHG01B-400 200NHG1B-400 224NHG1B-400 250NHG1B-400 35NHG02B-400 40NHG02B-400 50NHG02B-400 63NHG02B-400 80NHG02B-400 100NHG02B-400 125NHG02B-400 160NHG02B-400 200NHG02B-400 224NHG02B-400 250NHG02B-400 315NHG2B-400 355NHG2B-400 400NHG2B-400 630NHG2B-400 250NHG03B-400 315NHG03B-400 355NHG03B-400 400NHG03B-400 500NHG3B-400 630NHG3B-400 Insulated metal gripping lugs 2NHG000BI-400 4NHG000BI-400 6NHG000BI-400 10NHG000BI-400 16NHG000BI-400 20NHG000BI-400 25NHG000BI-400 32NHG000BI-400 35NHG000BI-400 40NHG000BI-400 50NHG000BI-400 63NHG000BI-400 80NHG000BI-400 100NHG000BI-400 125NHG00BI-400 160NHG00BI-400 35NHG01BI-400 40NHG01BI-400 50NHG01BI-400 63NHG01BI-400 80NHG01BI-400 100NHG01BI-400 125NHG01BI-400 160NHG01BI-400 200NHG1BI-400 224NHG1BI-400 250NHG1BI-400 35NHG02BI-400 40NHG02BI-400 50NHG02BI-400 63NHG02BI-400 80NHG02BI-400 100NHG02BI-400 125NHG02BI-400 160NHG02BI-400 200NHG02BI-400 224NHG02BI-400 250NHG02BI-400 315NHG2BI-400 355NHG2BI-400 400NHG2BI-400 250NHG03BI-400 315NHG03BI-400 355NHG03BI-400 400NHG03BI-400 500NHG3BI-400 630NHG3BI-400 Pack quantity 3 * Available upon request EATON www.eaton.com 3 Technical Data 720099 400 Volts gG/gL NH Fuse links Effective October 2017 Time in seconds (s) Time-current curves - NH Size 000 Current in Amps (A) Technical data - NH size 000 Part numbers Part numbers with insulated with metal metal gripping gripping lugs lugs 2NHG000B-400 2NHG000BI-400 4NHG000B-400 4NHG000BI-400 6NHG000B-400 6NHG000BI-400 10NHG000B-400 10NHG000BI-400 16NHG000B-400 16NHG000BI-400 20NHG000B-400 20NHG000BI-400 25NHG000B-400 25NHG000BI-400 32NHG000B-400 32NHG000BI-400 35NHG000B-400 35NHG000BI-400 40NHG000B-400 40NHG000BI-400 50NHG000B-400 50NHG000BI-400 63NHG000B-400 63NHG000BI-400 80NHG000B-400 80NHG000BI-400 100NHG000B-400 100NHG000BI-400 I2t (Amps2 Seconds) Fuse link size 000 Rated current (Amps) 2 4 6 10 16 20 25 32 35 40 50 63 80 100 Rated voltage (V a.c.) 400 Minimum pre-arcing 3.5 6 14 60 240 584 1000 2400 2900 4000 4000 6000 9900 18,100 *I1 120kA at 400 V a.c. 5.5 10.5 19 175 710 1800 2800 9600 11,300 16,400 12,000 20,400 35,700 39,800 Watts loss 0.8 1.4 2.2 1.5 2.3 2.2 3.1 2.8 2.8 3 3.4 4.5 4.7 5.2 Net weight per fuse (kg) 0.133 *I1 is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements EATON www.eaton.com 4 Technical Data 720099 400 Volts gG/gL NH Fuse links Effective October 2017 Time in seconds (s) Time-current curves - NH Size 00 Current in Amps (A) Technical data - NH size 00 Part numbers with metal gripping lugs 125NHG00B-400 160NHG00B-400 Part numbers with insulated metal gripping Fuse link lugs size 125NHG00BI-400 00 160NHG00BI-400 I2t (Amps2 Seconds) Rated current (Amps) 125 160 Rated voltage (V a.c.) 400 Minimum pre-arcing 25,000 60,000 *I1 120kA at 400 V a.c. 80,000 126,000 *I1 is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements 5 EATON www.eaton.com Watts loss 8 7.8 Net weight per fuse (kg) 0.185 Technical Data 720099 400 Volts gG/gL NH Fuse links Effective October 2017 Time in seconds (s) Time-current curves - NH Size 01 and 1 Current in Amps (A) Technical data - NH size 01 and 1 I2t (Amps2 Seconds) Part numbers with metal gripping lugs 35NHG01B-400 40NHG01B-400 50NHG01B-400 Part numbers with insulated gripping lugs 35NHG01BI-400 40NHG01BI-400 50NHG01BI-400 63NHG01B-400 80NHG01B-400 100NHG01B-400 125NHG01B-400 160NHG01B-400 200NHG1B-400 224NHG1B-400 250NHG1B-400 63NHG01BI-400 80NHG01BI-400 100NHG01BI-400 125NHG01BI-400 160NHG01BI-400 200NHG1BI-400 224NHG1BI-400 250NHG1BI-400 Fuse link size 01 1 Rated current (Amps) 35 40 50 63 80 100 125 160 200 224 250 Rated voltage (V a.c.) 400 Minimum pre-arcing 2400 3300 4200 *I1 120kA at 400 V a.c. 7600 10,600 10,400 Watts loss 4.9 5 4.7 6600 9600 16,000 24,000 53,000 89,000 119,000 171,000 16,300 33,600 56,000 86,400 111,300 232,000 322,000 479,000 5.6 5.6 6.8 8.8 8.9 12 12 14 Net weight per fuse (kg) 0.269 0.387 *I1 is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements EATON www.eaton.com 6 Technical Data 720099 400 Volts gG/gL NH Fuse links Effective October 2017 Time-current curves - NH Size 02 and 2 10 000 400 355 6 4 315 2 250 1 000 224 6 200 4 160 2 125 100 100 6 80 TIME - Seconds Time in seconds (s) 4 63 2 50 10 40 35 6 4 2 630 1 6 4 2 0.1 6 4 2 0.01 6 8 100 2 4 6 8 1000 Current in Amps (A) CURRENT - Amperes 2 4 6 8 10 000 2 Technical data - NH size 02 and 2 I2t (Amps2 Seconds) Part numbers with metal gripping lugs 35NHG02B-400 40NHG02B-400 50NHG02B-400 Part numbers with insulated metal gripping lugs 35NHG02BI-400 40NHG02BI-400 50NHG02BI-400 63NHG02B-400 80NHG02B-400 100NHG02B-400 125NHG02B-400 160NHG02B-400 200NHG02B-400 224NHG02B-400 250NHG02B-400 315NHG2B-400 355NHG2B-400 400NHG2B-400 630NHG2B-400 63NHG02BI-400 80NHG02BI-400 100NHG02BI-400 125NHG02BI-400 160NHG02BI-400 200NHG02BI-400 224NHG02BI-400 250NHG02BI-400 315NHG2BI-400 2 355NHG2BI-400 400NHG2BI-400 - Fuse link size 02 Rated current (Amps) 35 40 50 63 80 100 125 160 200 224 250 315 355 400 630 Rated voltage (V a.c.) 400 Minimum pre-arcing 2400 3300 4200 *I1 120kA at 400 V a.c. 7600 10,600 10,400 Watts loss 4.4 5 6.5 6600 10,000 16,000 24,000 50,000 89,000 119,000 171,000 280,000 350,000 504,000 2,100,000 16,300 34,800 56,000 86,400 185,000 232,000 322,000 479,000 924,000 1,155,000 1,673,000 5,775,000 5.5 5.5 6.6 8.7 10 12 12 14 19 22 24 44 *I1 is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements 7 EATON www.eaton.com Net weight per fuse (kg) 0.402 0.630 Technical Data 720099 400 Volts gG/gL NH Fuse links Effective October 2017 Time in seconds (s) Time-current curves - NH Size 03 and 3 Current in Amps (A) Technical data - NH size 03 and 3 I2t (Amps2 Seconds) Part numbers with metal gripping lugs 250NHG03B-400 315NHG03B-400 355NHG03B-400 Part numbers with insulated metal gripping lugs 250NHG03BI-400 315NHG03BI-400 355NHG03BI-400 Fuse link size 03 400NHG03B-400 500NHG3B-400 630NHG3B-400 400NHG03BI-400 500NHG3BI-400 630NHG3BI-400 3 Rated current (Amps) 250 315 355 Rated voltage (V a.c.) 400 400 500 630 Minimum pre-arcing 115,000 280,000 350,000 *I1 120kA at 400 V a.c. 379,500 924,000 1,155,000 Watts loss 18 19 22 504,000 686,000 1,590,000 1,663,000 2,605,000 6,201,000 24 30 36 *I1 is the maximum breaking capacity test at rated voltage according to IEC 60269 requirements Eaton EMEA Headquarters Route de la Longeraie 7 1110 Morges, Switzerland Net weight per fuse (kg) 0.634 1.043 Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. Eaton Electrical Products Limited Melton Road Burton-on-the-Wolds Leicestershire, LE12 5TH United Kingdom (c) 2017 Eaton All Rights Reserved PDF Only Publication No. 720099 October 2017 Eaton is a registered trademark. All other trademarks are property of their respective owners.