Industr ial / Com merc i al Options
· 1% AQL 2 Side Visual Screening.
· 100% 4 Side Visual Screening.
· 1% AQL for the electrical parameter s
Capacitance, Dissipation Factor,
Insulation Resistance, and Dielectric
Withstanding Voltage.
High Relia bility Options
MIL-PRF-49464 Group A
· 100%, 100 +0 /-4 Hours Voltage
Conditioning.
· 100% Electrical Screening
· 100% 6 Side Visual Screening.
· Bond Strength.
· Die Shear Strength.
· Temperature Coefficient Limits.
MIL-PRF-49464 G roup B
· MIL-PRF-49464, Group A above
· Thermal Shock and Immersion.
· Resistance to Soldering Heat.
· Moisture Resistance.
· Low Voltage Humidity.
· Life.
Special agreed upon testing to customers’
formal specification. Customer Drawing
Required!
(May include, but is not limited to, one o r
more of the followi ng common requests.)
· MIL-PRF-38534 Class H Element
Evaluation.
· MIL-PRF-38534 Class K Element
Evaluation.
· 10(0) Destructive Bond Pull per MIL -
STD-883, Method 2011.
· 10(0) Die Shear per MIL -STD-883,
Method 2019.
Consult Factory for other al terna t i v es or
assistance in specifying custom testing.
6 Side Visual Screening per MIL -STD-883,
Method 2032.
7
Dielectric Aging Characteristics
Test Level Codes
A, (modified), -55°C to +125°C.
Resistance to Solder Heat
Vibration, High Frequency
G, 30g’s peak, 10Hz to 2kHz.
D, 3 grams minimum with .001” dia wire
Limit per MIL -STD-883, Figure 2019-4.
Environmental & Physical Testing Procedures Capacitance Tolerance Table
Industr ial / Com merc i al Options
· 1% AQL 2 Side Visual Screening.
· 100% 4 Side Visual Screening.
· 1% AQL for the electrical parameters
Capacitance, Dissipation Factor,
Insulation Resistance, and Dielectric
Withstanding Voltage.
MIL-PRF-49464 Group A
· 100%, 100 +0 /-4 Hours Voltage
Conditioning.
· 100% Electrical Screening
· 100% 6 Side Visual Screening.
· Bond Strength.
· Die Shear Strength.
· Temperature Coefficient Limits.
MIL-PRF-49464 Group B
· MIL-PRF-49464, Group A above
· Thermal Shock and Immersion.
· Resistance to Soldering Heat.
· Moisture Resistance.
· Low Voltage Humidity.
· Life.
Special agreed upon testing to customers’
formal specification. Customer Drawing
Required!
(May include, but is not limited to, one o r
more of the followi ng common requests.)
· MIL-PRF-38534 Class H Element
Evaluation.
· MIL-PRF-38534 Class K Element
Evaluation.
· 10(0) Destructive Bond Pull per MIL -
STD-883, Method 2011.
· 10(0) Die Shear per MIL -STD-883,
Method 2019.
Consult Factory for other al terna t i v es or
assistance in specifying custom testing.
6 Side Visual Screening per MIL -STD-883,
Method 2032.
-16
-14
-12
-10
-8
-6
-4
-2
0
00.1 110 100 1000 10000 100000