Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
© 2005 Tyco Electronics Corporation. All rights reserved.
SPECIFICATION CONTROL DRAWING
55A1141
Title
FOUR CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT
Date
7-26-05
Revision
A
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
COMPONENT WIRES – 55A0111 SHIELD – TIN-COATED COPPER JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
CABLE CONSTRUCTION DETAILS
JACKET THICKNESS
(in.) OUTSIDE DIAMETER
(in.)
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
SHIELD
SIZE
(AWG) MINIMUM NOMINAL NOMINAL MAXIMUM
MAXIMUM
WEIGHT
(lb/1000 ft)
55A1141-30-* 30 38 .006 .008 .091 .104 7.7
55A1141-28-* 28 38 .006 .008 .098 .113 9.3
55A1141-26-* 26 38 .006 .008 .110 .127 12.1
55A1141-24-* 24 38 .006 .008 .123 .141 15.4
55A1141-22-* 22 38 .006 .008 .137 .159 19.7
55A1141-20-* 20 38 .006 .008 .154 .179 27.0
55A1141-18-* 18 38 .006 .008 .178 .208 37.7
55A1141-16-* 16 38 .006 .008 .198 .231 46.4
55A1141-14-* 14 38 .007 .009 .241 .282 69.1
55A1141-12-* 12 38 .007 .009 .284 .334 99.6
55A1141-10-* 10 38 .008 .010 .347 .408 154.
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 7 hours
BLOCKING: 200 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
FLAMMABILITY: Procedure 1,
3 seconds (maximum); 3 inches (maximum);
no flaming of facial tissue
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
LIFE CYCLE: 200 ± 3°C for 168 hours
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND TEST (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The "*" in the part numbers above shall be replaced by color
code designators with a slash separating the component
wire colors and a dash separating the component wire colors
from the jacket color.
1/ Example: AWG 22, black, brown, red and orange
component wires; white jacket:
55A1141-22-0/1/2/3-9
NOTE: Nominal values are for information only.
Nominal values are not requirements.
Page 1 of 1