LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
1 Revision: S6
2011/06/22
www.deltaww.com
RoHS Compliant 1310nm 6.144 Gbps SFP
Transceiver for CPRI Application
FEATURES
RoHS compliance
Compliant with SFP transceiver SFF-8472
MSA specification
1310nm FP laser
Built-in digital diagnostic monitoring function
Compliant with CPRI protocols for wireless
base station
Compliant with Industry Standard RFT
Electrical Connector and Cage
Duplex LC connector
Laser Class 1 Product which comply with the
requirements of EN 60825
Description
The LCP-6144B4HDRx is hot pluggable 3.3V
Small-Form-Factor transceiver modules designed
for high-speed communication applications that
require rates up to 6.144Gbps.
The LCP-6144B4HDRx is designed to be
compliant with SFF-8472 SFP Multi-source
Agreement (MSA) with digital diagnostic
monitoring functions: Temperature, V
CC
, TX
optical power, TX laser bias current, and RX
received optical power.
The post-amplifier of the LCP-6144B4HDRx
also includes a Loss of Signal (LOS) circuit that
provides a TTL logic-high output when the received
optical level is below a preset LOS Assert
threshold.
Applications
Up to 2km link over SMF for 6.144Gbps CPRI
application
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
2 Revision: S6
2011/06/22
www.deltaww.com
Absolute Maximum Ratings
Parameter Symbol
Min. Typ. Max. Unit
Storage Temperature T
S
-40 85
Supply Voltage Range @3.3V V
CC3
-0.5 3.6 V
Recommended Operating Conditions
Parameter Symbol
Min. Typ. Max. Unit Note
Case Operating Temperature T
C
-5 +70 1
Supply Voltage @3.3V V
CC3
3.135 3.30 3.465
V
Relative Humidity (non condensation) - 5 85 %
Note 1: See order information for detail
Electrical Characteristics
(V
CC
=3.135V to 3.465V)
Parameter Symbol
Min. Typ. Max. Unit Note
Total Supply Current I
CC
330 mA
Transmitter
Transmitter Differential Input Voltage Vin,pp
0.3 1 V 1
Transmitter Disable Input-High V
DISH
2 V
CC
+0.3
V
Transmitter Disable Input-Low V
DISL
0 0.8 V
Transmitter Fault Pull up Resistor R
TX_FAULT
4.7 10 k 2
Transmitter Fault Output-High V
TXFH
2 V
CC
+0.3
V
Transmitter Fault Output-Low V
TXFL
0 0.8 V
Receiver
Receiver Differential Output Voltage V
out,pp
0.4 0.7 1 V 3
Receiver LOS Load R
RXLOS
4.7 10 k 2
LOS Output Voltage-Low V
LOSH
2 V
CC
+0.3
V
LOS Output Voltage-High V
LOSL
0 0.8 V
Output Data Rise/Fall Time @6.144Gbps t
r
/ t
f
30 psec 4
Notes:
1. Internally AC coupled and terminated to 100 Ohm differential load.
2. Pull up to V
CC
on host Board.
3. Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer.
4. Unfiltered, 20 – 80%.
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
3 Revision: S6
2011/06/22
www.deltaww.com
Optical Transmitter Characteristics
Parameter Symbol Min Typ Max Units
Notes
Center Wavelength λ 1260 1360 nm
Optical Modulaion Amplitude OMA 300 uW
Spectral Width (RMS) σ 4 nm
Side Mode Suppression Ratio SMSR 30 dB
Average output power
AP -8.4 +0.5 dBm
Extinction Ratio ER 3.5 dB
Transmitter eye mask {0.25, 0.40, 0.45, 0.25, 0.28, 0.40}
Output Eye Mask
4. Optical Receiver Characteristics
Parameter Symbol Min Typ Max Units Notes
Overload P
O
0 dBm
Sensitivity in OMA @ 6.144Gbps RSO 46 uW [1]
Wavelength λ 1260 1580 nm
LOS De-assert LOS
D
-16 dBm
LOS Assert LOS
A
-30 dBm
Return Loss
12 dB
LOS Hysteresis
0.5 dB
Notes:
1. Value in OMA measured with 2^7-1 PRBS for BER = 10
-12
.
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
4 Revision: S6
2011/06/22
www.deltaww.com
SFP+ Transceiver Electrical Pad Layout
Module Electrical Pin Definition
Pin
Logic Symbol Name/Description Note
1 VeeT Module Transmitter Ground 1
2 LVTTL-O TX_Fault Module Transmitter Fault 2
3 LVTTL-I TX_Disable Transmitter Disable; Turns off transmitter laser output 3
4 LVTTL-I/O SDA 2- write Serial Interface Data Line
5 LVTTL-I/O SCL 2- write Serial Interface Clock
6 MOD_ABS Module Absent, connected to V
ee
T or V
ee
R in the module 4
7 LVTTL-I RS0 Not Implement
8 LVTTL-O RX_LOS Receiver Loss of Signal Indication 2
9 LVTTL-I RS1 Not Implement
10
VeeR Module Receiver Ground 1
11
VeeR Module Receiver Ground 1
12
CML-O RD- Receiver Inverted Data Output
13
CML-O RD+ Receiver Non-Inverter Data Output
14
VeeR Module Receiver Ground 1
15
VccR Module Receiver 3.3V Supply
16
VccT Module Transmitter 3.3V Supply
17
VeeT Module Transmitter Ground 1
18
CML-I TD+ Transmitter Non-Inverted Data Input
19
CML-I TD- Transmitter Inverted Data Input
20
VeeT Module Transmitter Griund 1
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
5 Revision: S6
2011/06/22
www.deltaww.com
Note:
1. The module signal ground pins, VeeR and VeeT, shall be isolated from the module case.
2. This pin is an open collector/drain output pin and shall be pulled up with 4.7k-10k ohms to Host_Vcc
on the host board. Pull ups can be connected to multiple power supplies, however the host board
design shall ensure that no module pin has voltage exceeding module VccT/R + 0.5V.
3. This pin is an open collector/drain input pin and shall be pulled up with 4.7k-10k ohms to VccT in the
Module.
4. This pin shall be pulled up with 4.7k-10k ohms to Host_Vcc on the host board.
Low speed electrical control pins and 2-wire interface
In addition to the 2-wire serial interface, the SFP+ module has the following low speed pins for control and
status:
TX_Fault
TX_Disable
RS0/RS1
MOD_ABS
RX_LOS
1 TX_Fault
TX_Fault is a module output pin that when High, indicates that the module transmitter has detected a fault
condition related to laser operation or safety.
The TX_Fault output pin is an open drain/collector and must be pulled p to the Host_Vcc with 4.7k-10k
ohms on the host board
2 TX_Disable
TX_Disable is a module input pin. When TX_Disable is asserted High or Left open, the SFP+ module
transmitter output must be turned off. The TX_DIS pin must be pulled up to VccT in the SFP+ module..
3 RS0/RS1
RS0 and RS1 are module input rate select pins and are pulled low to VeeT with a > 30k resistor in the
module. RS0 is an input hardware pin which optionally selects the optical receive data path rate coverage
for an SFP+ module. RS1 is an input hardware pin which optionally selects the optical transmit path data
rate coverage for an SFP+ module.
4 MOD_ABS
Mod_ABS is pulled up to Host_Vcc with 4.7k-10k ohms on the host board and connected to VeeT or VeeR
in the SFP+ module. MOD_ABS is then asserted “High” when the SFP+ module is physically absent from
a host slot. In the SFP MSA (INF8074i) this pin had the same function but is called MOD_DEF0.
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
6 Revision: S6
2011/06/22
www.deltaww.com
5 SCL/SDA
SCL is the 2-wire interface clock and SDA is the 2-wire interface data line. SCL and SDA are pulled up to
a voltage in the range of 3.14V to 3.46V on the host.
6 RX_LOS
RX_LOS when High indicated an optical signal level below that specified in the relevant standard. The
RX_LOS pin is an open drain/collector output and must be pulled up to host Vcc with a 4.7k-10k ohms on
the host board.RX_LOS assert min and de-assert max are defined in the relevant standard. To avoid
spurious transition of RX_LOS a minimum hysteresis of 0.5 dB is recommended.
Recommend Circuit Schematic
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
7 Revision: S6
2011/06/22
www.deltaww.com
Package Outline Drawing for Metal Housing with Bail de-latch
Latch Color Identifier
Blue
Complies with 21 CFR
1040.10 and 1040.11
Made in x
FS
1.UNIT:mm
SEE COLOR CODE
SEE COLOR CODE
2.COLOR CODE:
NOTES:
SINGLE MODE IS BLUE
MULTI MODE IS BLACK
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
8 Revision: S6
2011/06/22
www.deltaww.com
Timing parameters for SFP+ management
Parameter Symbol Min. Max. Unit Note
TX_DISABLE Assert time t_off 100 msec 1
TX_DISABLE Deassert time t_on 100 msec 2
Time to initialize, including
reset of TX_FAULT t_init 300 msec 3
TX Fault Assert Time t_fault 100 msec 4
TX_DISABLE to reset t_reset 10 µsec 5
LOS Assert Time t_loss_on 100 msec 6
LOS Deassert Time t_loss_off 100 msec 7
Serial ID Clock Rate f_serial_clock 100 kHz
Notes:
1)
Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal
2)
Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of
nominal
3)
From power on or negation of TX_Fault using TX Disable
4)
Time from fault to TX fault on.
5)
Time TX Disable must be held high to reset TX_Fault
6) Time from LOS state to Rx LOS assert
7) Time from non-LOS state to Rx LOS deassert
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
9 Revision: S6
2011/06/22
www.deltaww.com
Enhanced Digital Diagnostic Interface
The memory map in the following describes an extension to the memory map defined in SFP MSA. The enhanced
interface uses the two wire serial bus address 1010001X (A2h) to provide diagnostic information about the module’s
present operating conditions.
2 wire address 1010000 X (A0h)
2 wire address 1010001 X (A2h)
0
0
55
Alarm and Warning Thresholds
(56 bytes)
95
Serial ID Defined by SFP MSA
(96 bytes) 56
95
Cal Constants
(40 bytes)
96
96
119
Real Time Diagnostic Interface
(24 bytes)
127
Vender Specific
(32 bytes) 120
127
Vender Specific
128
128
247
User Writable EEPROM
(120 bytes)
255
Reserved in SFP MSA
(128 bytes) 248
255
Vender Specific
(8 bytes)
Digital Diagnostic Memory Map Specific Data Field Descriptions
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
10 Revision: S6
2011/06/22
www.deltaww.com
EEPROM Serial ID Memory Contents (2-Wire Address A0h)
Address Hex ASCII Address Hex ASCII Address Hex ASCII
00 03 43 2D - 86 DC
01 04 44 36 6 87 DC
02 07 45 31 1 88 DC
03 00 46 34 4 89 DC
04 00 47 34 4 90 DC
05 00 48 42 B 91 DC
06 00 49 34 4 92 68
07 00 50 48 H 93 F0
08 00 51 44 D 94 03
09 00 52 52 R 95 CS2 Note 5
10 00 53 20 Note 1 96 00
11 03 54 20 97 00
12 3D 55 20 98 00
13 00 56 41 99 00
14 02 57 00 100 00
15 14 58 00 101 00
16 00 59 00 102 00
17 00 60 05 103 00
18 00 61 1E 104 00
19 00 62 00 105 00
20 44 D 63 CS1 Note 2 106 00
21 45 E 64 00 107 00
22 4C L 65 1A 108 00
23 54 T 66 00 109 00
24 41 A 67 00 110 00
25 20 68 SN Note 3 111 00
26 20 69 SN 112 00
27 20 70 SN 113 00
28 20 71 SN 114 00
29 20 72 SN 115 00
30 20 73 SN 116 00
31 20 74 SN 117 00
32 20 75 SN 118 00
33 20 76 SN 119 00
34 20 77 SN 120 00
35 20 78 SN 121 00
36 00 79 SN 122 00
37 00 80 SN 123 00
38 00 81 SN 124 00
39 00 82 SN 125 00
40 4C L 83 SN 126 00
41 43 C 84 DC Note 4 127 00
42 50 P 85 DC 128 00 Note 6
Notes:
1) Byte 53: Base on part number. Please reference ordering information.
2) Byte 63: Check sum of bytes 0-62.
3) Byte 68-83: Serial number.
4) Byte 84-91: Date code.
5) Byte 95: Check sum of bytes 64-94.
6) Byte 128 to 255 had been set hex 00.
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
11 Revision: S6
2011/06/22
www.deltaww.com
Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
Address
#
Bytes
Name Value (Dec.) Unit Note
00-01 2 Temp High Alarm T
C
(MAX.)+8
02-03 2 Temp Low Alarm T
C
(MIN.)-8
04-05 2 Temp High Warning T
C
(MAX.)+3
06-07 2 Temp Low Warning T
C
(MIN.)-3
1
08-09 2 Voltage High Alarm 3.8
10-11 2 Voltage Low Alarm 2.8
12-13 2 Voltage High Warning 3.5
14-15 2 Voltage Low Warning 3.1
Volt
16-17 2 Bias High Alarm I
OP
*2+35
18-19 2 Bias Low Alarm I
OP
–25
20-21 2 Bias High Warning I
OP
*2+30
22-23 2 Bias Low Warning I
OP
–20
mA 2
24-25 2 TX Power High Alarm 2.5
26-27 2 TX Power Low Alarm -10.4
28-29 2 TX Power High Warning 1.5
30-31 2 TX Power Low Warning -9.4
dBm
32-33 2 RX Power High Alarm 2
34-35 2 RX Power Low Alarm -15.4
36-37 2 RX Power High Warning 1
38-39 2 RX Power Low Warning -14.4
dBm
40-45 16 Reversed
56-91 36 External Calibration Constants
92-94 3 Reversed
95 1 Checksum 3
96-97 2 Real Time Temperature
98-99 2 Real Time Supply Voltage
100-101
2 Real Time Tx Bias Current
102-103
2 Real Time Tx Optical Power
104-105
2 Real Time Rx Received Power
106-109
4 Reserved
110 1 Optional Status/ Control Bits 4
111 1 Reserved
112-119
8 Optional Set of Alarm and Warning 5
Notes:
1) T
C
: Case Operating temperature
2) I
OP
: Operating current at room temperature. The min. setting current is 0 mA.
3) Byte 95 contains the low order 8bits of sum of bytes 0~94
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
12 Revision: S6
2011/06/22
www.deltaww.com
4)
State/ Control Bits
Byte Bit Name Description
110 7 Tx Disable State Digital state of the Tx disable input pin
110 6 Soft Tx Disable Read/ Write bit that allow software disable of laser
110 5 Reserved
110 4 Rate Select State Rate Select State
110 3 Soft Rate Select Software Rate Select State
110 2 Tx Fault Digital state of the Tx fault output pin
110 1 LOS Digital state of the LOS output pin.
110 0 Data_Ready_Bar NA
5.)
Optional Set of Alarm and Warning
Byte Bit Name Description
112 7 Temp High Alarm Set when internal temperature exceeds high alarm level
112 6 Temp Low Alarm Set when internal temperature is below low alarm level
112 5 Vcc High Alarm Set when internal supply voltage exceeds high alarm level
112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level
112 3 Tx Bias High Alarm Set when Tx Bias current exceeds high alarm level
112 2 Tx Bias Low Alarm Set when Tx Bias current is below low alarm level
112 1 Tx Power High Alarm Set when Tx output power exceeds high alarm level
112 0 Tx Power Low Alarm Set when Tx output power is below low alarm level
113 7 Rx Power High Alarm Set when received power exceeds high alarm level
113 6 Rx Power Low Alarm Set when received power is below low alarm level
113 5-0 Reserved
116 7 Temp High Warning Set when internal temperature exceeds high warning level
116 6 Temp Low Warning Set when internal temperature is below low warning level
116 5 Vcc High Warning Set when internal supply voltage exceeds high warning level
116 4 Vcc Low Warning Set when internal supply voltage is below low warning level
116 3 Tx Bias High Warning Set when Tx Bias current exceeds high warning level
116 2 Tx Bias Low Warning Set when Tx Bias current is below low warning level
116 1 Tx Power High Warning Set when Tx output power exceeds high warning level
116 0 Tx Power Low Warning Set when Tx output power is below low warning level
117 7 Rx Power High Warning Set when received power exceeds high warning level
117 6 Rx Power Low Warning Set when received power is below low warning level
117 5-0 Reserved
Digital Diagnostic Monitor Accuracy
Parameter Typical Value Note
Transceiver Temperature ± 5
Power Supply Voltage ±3% 1
TX Bias Current ± 10%
TX Optical Power ± 3dB
RX Optical Power ± 3dB
Notes:
1)
Voltage is measured internal to the transceiver
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
13 Revision: S6
2011/06/22
www.deltaww.com
Regulatory Compliance
Feature Reference
Electromagnetic Interference (EMI) FCC Part15 Class B
Electrostatic Discharge (ESD) IEC/EN 61000-4-2
MIL-STD-883E
EIA-JESD22-A115-A
Laser Eye Safety IEC 60825-1:2001
EN 60825
Component Recognition IEC/EN 60950-1
UL60950
Ordering information for SFP modules
LCP-6144B4HDRX
1
X
1
:
Temperature
Blank: -5 to +70 degree C
H: -10 to +85 degree C
T: -40 to +85 degree C
Appendix A. Document Revision
Version No. Date Description
S0 2010-09-03 First released
S1 2010-10-15
P2: Electrical output data rise/ fall time of Rx was changed
30~85ps.
P3: Optical rise/ fall time of Tx was changed max. 70ps.
P11: Correct the alarm setting value of Tx power.
S2 2010-11-24 P3: Updated eye mask specification.
S3 2010-12-13
P1: Laser is changed from FP to DFB laser.
P2: Modified Rx differential output voltage.
P3: Updated wavelength information of Tx and Rx.
LCP-6144B4HDRx
DELTA ELECTRONICS, INC.
14 Revision: S6
2011/06/22
www.deltaww.com
S4 2010-12-21
P1: Laser is changed from DFB to FP laser.
P3: Changed the wavelength range and
spectral width of
Tx as laser is changed from DFB to FP laser.
S5 2011-03-11 P11: Modified the low alarm and warning of bias setting.
S6 2011-06-22 P3: Modified the spec. of rising and falling time.