Industrial Power Supplies TSP Series, 90-600 Watt CB Innovative and Powerful Features! True industrial grade design Rugged metal case for EMC LVD Scheme IEC 60950-1 UL 60950-1 UL 508 UL 60079-15 ATEX II3G IECEX harsh industrial environments For worldwide use - Autoselect input and international safety approvals ATEX and IECEx certification (opt. EX) Model TSP 090-124N meets NEC class 2 Industrial operating temperature range: -25C to +70C Variable output voltage Indefinite short circuit, overvoltage and overtemperature protection Power OK signal Remote On/Off Shock and vibration proof Wall mounting (opt.) Redundancy module Buffer module for power backup Battery controller module 3-year product warranty The TRACOPOWER TSP series is a new generation of high performance DIN-rail mount power supplies designed to work reliably even under difficult factory floor conditions. Excellent electrical specifications and high immunity against electrical disturbances makes these compact modules the best choice to power sensitive loads in industrial process control systems, machine tools or other demanding industrial applications. Easy installation with detachable screw terminal block and snap-on mounting on DIN-rails. For system applications all models offer a DC-OK signal and external shut down function. Redundant operation with true power sharing is available as an option. With another option these power supplies can be extended to build a perfect DCUPS system with automatic battery management. The TSP series power supplies complies with the latest safety and EMC standards for industrial environments and are also available with ATEX certification for applications in hazardous locations (class I, division 2) Models Order Code Output Power (Pmax) **Output Voltage (Vnom) ***Output Current (Imax) TSP 070-112* 72 W 12 VDC 6.0 A TSP 090-124* 90 W 24 VDC 3.75 A TSP 090-124N 90 W 24 VDC 3.75 A TSP 090-148* 96 W 48 VDC 2.0 A TSP 140-112* 144 W 12 VDC 12.0 A TSP 180-124* 180 W 24 VDC 7.5 A TSP 180-148* 192 W 48 VDC 4.0 A 24 VDC 15.0 A TSP 360-124* TSP 360-148* 360 W TSP 600-124* TSP 600-136 TSP 600-148* 600 W 48 VDC 7.5 A 24 VDC 25.0 A 36 VDC 16.5 A 48 VDC 12.5 A * For ATEX / IECEx compliant model add appendix -EX to order code. ** Output voltage adjustable 12-14 VDC, 24-28 VDC and 48-56VDC *** Max. current at nominal output voltage and operating temperature up to 40 C max. http://www.tracopower.com Page 1 of 15 Industrial Power Supplies TSP Series 90-600 Watt Product Features The Ultimate DIN - Rail Power Supply ! Remote On/Off Control Output for true N+1 Redundancy or Battery Operation Jumper for Parallel Operation or Battery Charge Mode selectable by Jumper Detachable Screw Terminal Block for quick disconnect and easy Installation Rugged, Ultracompact Metal Case, Shock and Vibration tested per IEC 60068-2 Standard Industrial Safety Approval Package to comply with: IEC/EN 60950-1 UL/cUL 60950-1 UL 508, CSA-C22.2 No.107 EN/UL 60079-15 ATEX 94/9/EC, IECEx (Opt. EX) ANSI/ISA 12.12.01 Double Output Terminals for easy wiring of multiple loads Dual Color Status Indicator LED EMC Compliance to EN 61204-3 Standard for Industrial Power Supplies SEMI F47 Adjustable Output Voltage Remote Diagnostic via floating Relay Contact or PNP Output Convection Cooling, no internal Fan, Thermal Overload Protection Autorange Input for worldwide Use Self-locking DIN-rail fixing Latch or optional Wall Mounting Brackets http://www.tracopower.com Page 2 of 15 Industrial Power Supplies TSP Series 90-600 Watt Input Specifications Input voltage range - TSP 070/090 85 - 263 VAC universal input - other models: 85 - 132 / 187 - 264 VAC autoselect - output current derating at operation below 100 VAC see graph B, page 5 Input voltage frequency 47 - 63 Hz Harmonic limits EN 61000-3-2, Class A (for limited output power) Holdup time 20 ms min. (full load 115/230 VAC) Inrush current - TSP 070/090 - TSP 140/180 - TSP 360 - TSP 600 115 VAC < 12 A < 13 A < 16 A < 25 A 230 VAC < 20 A < 25 A < 25 A < 30 A Recommended circuit breaker, - TSP 070/090/140/180 6.0 - 16.0 A characteristic B - TSP 360 10.0 - 16.0 A - TSP 600 16.0 - 25.0 A Efficiency 87 % typ. Output Specifications Output voltage adj. range - 12 VDC models: - 24 VDC models: - 36 VDC model: - 48 VDC models: Regulation 12 - 14 VDC 24 - 28 VDC 36 - 42 VDC 48 - 56 VDC At output voltage higher than nominal output voltage max. output current has to be reduced accordingly, in order not to exceed max. output power. - Input variation 0.5 % max. - Load variation (10-100 %) 0.5 % max. Ripple and Noise (20MHz bandwidth) 100 mV pk-pk typ. (200 mV pk-pk max. at Imax) Electronic short circuit protection current limitation at Imax. constant current, automatic recovery Output overvoltage protection - 12 VDC models: - 24 VDC models: - 36 VDC model: - 48 VDC models: 20 V 35 V 43 V 60 V Overload protection electronic overload protection Overtemperature protection switch off at overtemperature, automatic restart Power back immunity - 12 VDC models: - 24 VDC models: - 36 VDC model: - 48 VDC models: 16 V 35 V 48 V 63 V Status indicator dual color LED (green: DC ok, red: DC off) Power OK signal - trigger threshold: - 12 VDC models: 9 - 11 V - 24 VDC models: 18 - 22 V - 36 VDC model: 27 - 34 V - 48 VDC models: 36 - 46 V - active output signal: - 12 VDC models: 11.0 V 1.0 V (reference to -Vout) (20 mA max. for TSP 070, 40 mA max. for TSP 140) - 24 VDC models: 22.0 V 2.0V / 20 mA max. (10 mA max. for TSP 090, 20mA max. for others) - 36 VDC model: 34.0 V 2.0 V / 20 mA max. - 48 VDC models: 44.0 V 4.0 V / 15 mA max. - relay output DC OK = contact closed rated: 30 VDC/1.0 A for 12/24 VDC models rated: 30 VDC/2.0 A for 36 VDC model rated: 48 VDC/0.5 A for 48 VDC models http://www.tracopower.com Page 3 of 15 Industrial Power Supplies TSP Series 90-600 Watt General Specifications Max. capacitive load unlimited Temperature range - Operating -25C to +70C max. (for derating see graph A on page 5) - Storage -25C to +85C Cooling convection cooling, no internal fan Humidity (non condensing) 95 % rel. H max. Pollution degree 2 Temperature coefficient 0.02 %/K Reliability, calculated MTBF (at +25C acc. to IEC 61709) - TSP 070/090 >1.8 Mio h - TSP 140 >1.2 Mio h - TSP 180/360/600 >0.9 Mio h Remote On/Off by ext. contact. DC on: -S contact open DC off: -S connectetd via 1Kohm to -Vout Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards - Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03 - Industrial control equipment UL 508, CSA-C22.2 No. 107 - Electrical equipment for machines EN 60204 - Electronic equipment for power installation EN 50178 - Safety transformers for SMPS EN 61558-2-16 - Limited power source (model TSP 090-124N) EN 60950 sect. 2.5 and NEC Class 2 - Control equipment for hazardous location UL 60079-15 (Class I, Division 2, Groups A,B,C,D AEx n C II C T4 U) IEC/EN 60079-15 (Class I, Zone 2, EEx nC II C T4 U), ( II3G EEX nAC IIC T4 (T3 with limited power) Safety approvals and - CB report for IEC/EN 60950-1 certifications www.tracopower.com/products/tsp-cb.pdf - UL approvals UL 60950-1 rec. File: e181381, UL 508C listed File: e210002 www.ul.com -> certifications - CSA certification (file no. 219759) for UL 60950-1, UL 508, UL 60079-15-02, ANSI/ISA 12.12.01, CSA-22.2 No. 60950-1-03, CSA C22.2 No. 107, CSA 60079-15-02 www.tracopower.com/products/tsp-csa.pdf - II3G ATEX 94/9/EC certificate no. EPS 12 ATEX 1 424 X (option -EX only) www.tracopower.com/products/tsp-atex.pdf - IECEx test report for IEC 60079-15 www.tracopower.com/products/tsp-iecex.pdf - BG certification for EN 60950-1, EN 60204, EN 61558-2-16, EN 50178 www.tracopower.com/products/tsp-bg.pdf Class of protection safety class I (IEC 536) Degree of protection IP 20 (IEC/EN 60529) Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 - Conducted RI suppression on input EN 55011 class B, EN 55022 class B, - Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 - Electrostatic discharge (ESD) IEC / EN 61000-4-2 4 kV / 8 kV criteria B - Radiated RF field immunity IEC / EN 61000-4-3 10 V / m criteria A - Electrical fast transient / burst immunity IEC / EN 61000-4-4 2 kV criteria B - Surge immunity IEC / EN 61000-4-5 1 kV / 2 kV criteria B - Immunity to conducted RF disturbances IEC / EN 61000-4-6 10 V criteria A - Power frequency field immunity IEC / EN 61000-4-8 30 A / m criteria A - Mains voltage dips and interruptions IEC / EN 61000-4-11 criteria B/C - Voltage sag immunity SEMI F47 www.tracopower.com/products/TSP_SemiF47.pdf http://www.tracopower.com Page 4 of 15 Industrial Power Supplies TSP Series 90-600 Watt General Specifications Environment - Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 - 55 Hz, 1 g, 1 oct/min - Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms Enclosure material aluminium (chassis) / stainless steel (cover) Mounting - DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) - Wall mounting (option) with wall mounting bracket - see page 12 Connection detachable screw terminals (plugs included) 2 terminals per output Remote On/Off connection - 2 pin molex male terminal KK series mating connector information (cable not included) www.tracopower.com/products/tsp-rc-cable.pdf Installation instructions www.tracopower.com/products/tsp_inst.pdf Output Power Derating A) B) Output Power Derating vs Ambient Temperature 100 100 80 60 50 40 -25 90 TSP 600 TSP 070 TSP 140 TSP 090 TSP 180 TSP 360 40 50 Temperature [C] 60 70 Output Power [% Pmax] Output Power [% Pmax] 90 70 Output Power Derating vs Input Voltage 80 70 60 50 40 85 90 100 110 115 132 187 Input Voltage [VAC] All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. http://www.tracopower.com 230 264 Page 5 of 15 AC/DC Power Modules TSP Series 90-600 Watt Function Modules Redundancy Module: With this module and two power supplies of the TSP series a highly reliable, true redundant power system can be configured without any additional components. This module provides: TSP-REM360 - Operation with true current sharing - Alarm outputs and redundancy OK signal - Hot swappable inputs can be loaded up to 15 A each (resp. 25 A with model TSP REM600) TSP-REM600 Models Order Code Output Voltage adj. Output Power TSP-REM360 24 VDC (24 - 27 VDC) 360 W TSP-REM600 600 W TSP-REM datasheet: www.tracopower.com/products/tsp-rem.pdf Battery Controller Module: This module provides a professional battery controller to charge and monitor an external lead-acid battery. Together with a power supply of the TSP series and a battery pack a perfect DC-UPS system can be configured. This module provides: - Battery protection for over voltage, deep discharge, short circuit and reverse connection - Remote On/Off for battery and power supply - Alarm outputs for input, output and battery condition - Controlled end of charge voltage by temperature sensor TSP-BCM12 TSP-BCM24 TSP-BCM48 TSP-BCM24A TSP-BCM48A Models Order Code Output Voltage Output Power TSP-BCM12 12 VDC 180 W TSP-BCM24 TSP-BCM24A TSP-BCM48 TSP-BCM48A TSP-BCMU360 24 VDC 48 VDC 24/48 VDC TSP-BCMU360 360 W 600 W 360 W TSP-BAT datasheet: www.tracopower.com/products/tsp-bat.pdf 600 W TSP-BCM datasheet: www.tracopower.com/products/tsp-bcm.pdf 360 W TSP-BCMU datasheet: www.tracopower.com/products/tsp-bcmu.pdf Buffer Module: This module will maintain the output voltage of a 24 VDC power supply during typical mains faults, short time blackouts or voltage dips of up to ten full 50 Hz cycles. During this buffer period no deterioration of the 24 VDC output voltage will occur. This module provides: TSP-BFM24 - Capacitor bank for energy storage, no battery needed! - Maintenance free, long lifetime, high performance also at low temperature. - Guaranteed Hold-up-time 200 ms/25 A to 4 s/1.2 A max. - Output 24 to 28 VDC, 600 W max. - Active ready and inhibit signals Models Order Code Output Voltage Output Power TSP-BFM24 24 - 28VDC 600 W http://www.tracopower.com TSP-BFM datasheet: www.tracopower.com/products/tsp-bfm.pdf Page 6 of 15 AC/DC Power Modules TSP Series 90-600 Watt TSP-BCM12 Battery Controller Module This module provides a professional battery management system to charge and monitor an external lead-acid battery. Together with a power supply of the TSP series, a perfect DC-UPS system can be configured. The connected battery will be charged and held in charged mode by the power supply. In the event of a mains power failure the battery will supply the output power until the battery is discharged. As a consequence, the output voltage of the system is equivalent to the battery voltage. To avoid overcharging the battery, an external temperature sensor adjusts the battery voltage automatically to the required end of charge voltage. This can extend the battery life. The battery is protected against deep discharge. Mains power and battery status are monitored regularly and failures indicated by corresponding LED's and alarm outputs. The module also provides an external On/Off input to switch-off both, power supply and battery. TSP-TS battery temperature sensor (10 kOhm NTC with 2m cable) included Models Order code (includes terminal plugs) Inputs Input Power max Output Voltage nom. *Output Power max. 180 W 12 VDC 180 W 12 VDC Power Supply and 12 VDC Battery TSP-BCM12 *reduce max. output current by battery charging current Function Diagram + DC IN_ TSP Power Supply Remote Link Connector Positions Front view J1.2 J2.3 J2.4 + J1.1 J2.1 J2.2 _ J1.4 + J1.3 _ J3.1 J3.2 Output Load Fuse Volt adjust Bottom view Top view - - + + Output 24V Battery Battery Controller J5.1 J5.2 J5.3 J5.4 J5.5 J5.6 DC-OK BAT.-OK DC-OK input output J5.7 J5.8 Remote On/Off J5.9 J5.10 AC OK Bat. OK DC OK Remote On/Off 48 V/6.6 A DC IN Battery Temp. Sensor (TS) Remote Link T Temp. Sensor TSP-TS (included) - + - + Specifications Operating temperature -25C to +70C max. derating above +40C : 1.67 %/K Electromagnetic compatibility in correspondence to connected units (no internal switching device) Battery protection against over voltage, deep discharge, overcharge, short circuit and reverse connection (built-in fuse) Status signals DC OK input, DC OK output, BAT OK all relay contact closed at status OK Rating per relay contact 30 VDC / 1.0 A max. Reliability, calculated MTBF, at +25C acc. to IEC 61709 >1.5 Mio h Dimensions see page 10 Remote link cable (0.5 m) 1 cable included (order code TSP-JC) www.tracopower.com/products/tsp-rc-cable.pdf Remote On/Off by ext. contact: contact open = On, contact closed = Off Safety approvals - CB test certificate IEC 60950-1 (SIQ for EN) www.tracopower.com/products/tsp-bcm-cb.pdf - BG certificate www.tracopower.com/products/tsp-bcm12-bg.pdf Installation instructions www.tracopower.com/products/tsp-bcm-manual.pdf http://www.tracopower.com Page 7 of 15 Industrial Power Supplies TSP Series 90-600 Watt TSP-BCM24 Battery Controller Module This module provides a professional battery management system to charge and monitor an external lead-acid battery. Together with a power supply of the TSP series, a perfect DC-UPS system can be configured. The connected battery will be charged and held in charged mode by the power supply. In the event of a mains power failure the battery will supply the output power until the battery is discharged. As a consequence, the output voltage of the system is equivalent to the battery voltage. To avoid overcharging the battery, an external temperature sensor adjusts the battery voltage automatically to the required end of charge voltage. This can extend the battery life. The battery is protected against deep discharge. Mains power and battery status are monitored regularly and failures indicated by corresponding LED's and alarm outputs. The module also provides an external On/Off input to switch-off both, power supply and battery. TSP-TS battery temperature sensor (10 kOhm NTC with 2m cable) included Models Order code (includes terminal plugs) Inputs Input Power max TSP-BCM24 24 VDC Power Supply and 24 VDC Battery 360 W TSP-BCM24A 600 W Function Diagram + DC IN_ TSP Power Supply Remote Link Output Voltage nom. 600 W *reduce max. output current by battery charging current Front view J2.3 J2.4 + J1.1 J2.1 J2.2 _ J1.4 + J1.3 _ J3.1 J3.2 Output Load Fuse Volt adjust 360 W 24 VDC Connector Positions J1.2 *Output Power max. Bottom view Top view - - + + Output 24V Battery Battery Controller J5.1 J5.2 J5.3 J5.4 J5.5 J5.6 DC-OK BAT.-OK DC-OK input output J5.7 J5.8 Remote On/Off J5.9 J5.10 AC OK Bat. OK DC OK Remote On/Off 48 V/6.6 A DC IN Battery Temp. Sensor (TS) Remote Link T Temp. Sensor TSP-TS (included) - + - + Specifications Operating temperature -25C to +70C max. derating above +40C : 1.67 %/K Electromagnetic compatibility in correspondence to connected units (no internal switching device) Battery protection against over voltage, deep discharge, overcharge, short circuit and reverse connection (built-in fuse) Status signals DC OK input, DC OK output, BAT OK all relay contact closed at status OK Rating per relay contact 30 VDC / 1.0 A max. Reliability, calculated MTBF, at +25C acc. to IEC 61709 >1.5 Mio h Dimensions see page 10 Remote link cable (0.5 m) 1 cable included (order code TSP-JC) www.tracopower.com/products/tsp-rc-cable.pdf Remote On/Off by ext. contact: contact open = On, contact closed = Off Safety approvals - CB test certificate IEC 60950-1 (SIQ for EN) www.tracopower.com/products/tsp-bcm-cb.pdf - BG certificate www.tracopower.com/products/tsp-bcm24-bg.pdf Installation instructions www.tracopower.com/products/tsp-bcm-manual.pdf http://www.tracopower.com Page 8 of 15 Industrial Power Supplies TSP Series 90-600 Watt TSP-BCM48 Battery Controller Module This module provides a professional battery management system to charge and monitor an external lead-acid battery. Together with a power supply of the TSP series, a perfect DC-UPS system can be configured. The connected battery will be charged and held in charged mode by the power supply. In the event of a mains power failure the battery will supply the output power until the battery is discharged. As a consequence, the output voltage of the system is equivalent to the battery voltage. To avoid overcharging the battery, an external temperature sensor adjusts the battery voltage automatically to the required end of charge voltage. This can extend the battery life. The battery is protected against deep discharge. Mains power and battery status are monitored regularly and failures indicated by corresponding LED's and alarm outputs. The module also provides an external On/Off input to switch-off both, power supply and battery. TSP-TS battery temperature sensor (10 kOhm NTC with 2m cable) included Models Order code (includes terminal plugs) Inputs Input Power max TSP-BCM48 48 VDC Power Supply and 48 VDC Battery 360 W TSP-BCM48A DC IN_ TSP Power Supply Remote Link 48 - 56 VDC 600 W Function Diagram + Output Voltage Connector Positions Front view J1.2 J1.1 Current Limit J3.1 J3.2 J2.3 J2.4 + J2.1 J2.2 _ J1.4 + J1.3 _ Output Load Fuse Volt adjust *Output Current max. 6.4 A 11.0 A Bottom view Top view - - + + Output 48V Battery Battery Controller J5.1 1 1 1 J5.2 J5.3 J5.4 J5.5 J5.6 DC-OK BAT.-OK DC-OK input output J5.7 J5.8 Remote On/Off J5.9 J5.10 AC OK Bat. OK DC OK Remote On/Off 48 V/6.6 A DC IN Battery Temp. Sensor (TS) Remote Link T Temp. Sensor TSP-TS (included) - + - + Specifications Operating temperature -25C to +70C max. derating above +40C : 1.67 %/K Electromagnetic compatibility in correspondence to connected units (no internal switching device) Battery protection against over voltage, deep discharge, overcharge, short circuit and reverse connection (built-in fuse) Status signals DC OK input, DC OK output, BAT OK all relay contact closed at status OK Rating per relay contact 30 VDC / 1.0 A max. Reliability, calculated MTBF, at +25C acc. to IEC 61709 >1.5 Mio h Dimensions see page 10 Remote link cable (0.5 m) 1 cable included (order code TSP-JC) www.tracopower.com/products/tsp-rc-cable.pdf Remote On/Off by ext. contact: contact open = On, contact closed = Off Installation instructions www.tracopower.com/products/tsp-bcm-manual.pdf http://www.tracopower.com Page 9 of 15 AC/DC Power Modules TSP Series 90-600 Watt TSP-BCMU360 Universal Battery Controller Module This module provides a professional battery management system to charge and monitor an external lead-acid battery. Together with a power supply of the TSP series or any other stabilized 24 VDC or 48 VDC power supply a perfect DC-UPS system can be configured. The connected battery will be charged and held in charged mode by the power supply. In the event of a mains power failure the battery will supply the output power until the battery is discharged. As a consequence, the output voltage of the system is equivalent to the battery voltage. To avoid overcharging the battery, an external temperature sensor adjusts the battery voltage automatically to the required end of charge voltage. This can extend the battery life. The battery is protected against deep discharge. Mains power and battery status are monitored regularly and failures indicated by corresponding LED's and alarm outputs. The module also provides an external On/Off input to switch-off both, power supply and battery. TSP-TS battery temperature sensor (10 kOhm NTC with 2m cable) included Models Order code (includes terminal plugs) TSP-BCMU360 Inputs Any 24 VDC or 48 VDC Power Supply or Battery Function Diagram Input Power max Output Voltage *Output Current max. 360 W 23.2 - 48.7 VDC 6.6 A Connector Positions Front view Bottom view Top view - - + + Output AC OK Bat. OK DC OK Remote On/Off 48 V/6.6 A DC IN Battery Temp. Sensor (TS) Remote Link - + - + Specifications Operating temperature -25C to +70C max. derating above +40C : 1.67 %/K Electromagnetic compatibility in correspondence to connected units (no internal switching device) Battery protection against over voltage, deep discharge, overcharge, short circuit and reverse connection (built-in fuse) Status signals DC OK input, DC OK output, BAT OK all relay contact closed at status OK Rating per relay contact 30 VDC / 1.0 A max. Reliability, calculated MTBF, at +25C acc. to IEC 61709 >1.5 Mio h Dimensions see page 10 Remote link cable (0.5 m) 1 cable included (order code TSP-JC) www.tracopower.com/products/tsp-rc-cable.pdf Remote On/Off by ext. contact: contact open = On, contact closed = Off Installation instructions www.tracopower.com/products/tsp-bcmu-manual.pdf http://www.tracopower.com Page 10 of 15 Industrial Power Supplies TSP Series 90-600 Watt TSP-BAT Battery Pack The TSP battery packs are designed to build, in connection with the TSP-BCM battery controller module, a complete DC-UPS system. The entire range utilizes 12 V maintenance free VRLA (valve regulated lead acid) batteries made by PANASONIC. These are not spillable lead gel type batteries. Two 12 V batteries are connected in series and assembled into a stainless steel enclosure, with integrated connector and connection cable. Models Order code (includes mating connectors) Nominal Voltage Charge current max. Nominal Capacity (at 25C, 77F) 0.36 A 1.2 Ah 0.80 A 3.4 Ah TSP-BAT24-012 TSP-BAT24-034 TSP-BAT24-072 24 VDC TSP-BAT24-120 TSP-BAT24-072KIT 7.2 Ah 3.00 A 12.0 Ah Installation rack without batteries TSP-BAT24-120KIT TSP-BAT24-012 1.75 A TSP-BAT24-034 TSP-BAT24-072 TSP-BAT24-120 Specifications Temperature ranges (max) - during discharge -15C to +50C max. - when charging / charged 0C to +40C max. - storage -15C to +40C max. Battery lifetime 3 - 5 years see general battery information for details & warranty limitations www.tracopower.com/products/tsp-panas_gen.pdf Remote link cable (0.5 m) 1 cable included (order code TSP-JC) www.tracopower.com/products/tsp-rc-cable.pdf Weight TSP-BAT24-034 3.2 kg (7.1lb) TSP-BAT24-072 5.8 kg (12.9lb) TSP-BAT24-120 9.0 kg (20.0lb) Battery datasheets TSP-BAT24-012 TSP-BAT24-034 TSP-BAT24-072 TSP-BAT24-120 http://www.tracopower.com www.tracopower.com/products/tsp-powers_012.pdf www.tracopower.com/products/tsp-panas_034.pdf www.tracopower.com/products/tsp-panas_072.pdf www.tracopower.com/products/tsp-panas_120.pdf Page 11 of 15 Industrial Power Supplies TSP Series 90-600 Watt Outline Dimensions 110.0 (1.38) (4.33) 38.5 (1.52) 35.0 DC OK DC ON O/P ADJ. 80.0 (3.15) 110.0 (4.33) Models: TSP 070/090 TSP-REM360 TSP-BCM12 TSP-BCM24 TSP-BCM48 PE N L (0.20) 25.0 5.0 5.0 (0.98) (0.20) P/S P S Remote Weight: 0.5kg (1.0lb) 110.0 (2.13) DC OK DC ON (4.33) 38.5 (1.52) 54.0 O/P ADJ. 80.0 (3.15) 110.0 (4.33) Models: TSP 140/180 TSP-REM600 TSP-BCM24A TSP-BCM48A TSP-BCMU360 TSP-BFM24 L (0.20) 25.0 5.0 (0.98) Remote 14.5 (0.57) S P PE N P/S Weight: 0.7kg (1.4lb) http://www.tracopower.com Dimensions in [mm], ( ) = inch Tolerances: 0.5 mm (0.02) Page 12 of 15 Industrial Power Supplies TSP Series 90-600 Watt Outline Dimensions TSP 360 125.0 (3.15) (4.92) 45.0 (1.77) 80.0 DC OK DC ON 86.5 (3.41) 125.0 (4.92) O/P ADJ. PE N L 46.0 5.0 (0.20) (1.81) 25.0 (0.98) 17.0 (0.67) 25.0 (0.98) Remote P S P/S Weight: 1.1kg (2.4lb) Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) http://www.tracopower.com Page 13 of 15 Industrial Power Supplies TSP Series 90-600 Watt Outline Dimensions TSP 600 P/S Remote P S 25.0 25.0 (0.98) (0.98) 21.0 123.0 (4.84) 125.0 (6.50) (4.92) DC ON DC OK PE N 86.5 (3.41) 125.0 (4.92) 45.0 (1.77) 165.0 (0.83) O/P ADJ. L Weight: 2.8kg (6.0lb) Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) http://www.tracopower.com Page 14 of 15 Industrial Power Supplies TSP Series 90-600 Watt TSP-WMK Wall Mounting Bracket Ordercode of Kit For Models Content of Kit TSP-WMK03 TSP-WMK02 TSP 070, TSP 090, TSP 140, TSP 180 TSP 360, TSP 600 1 bracket 2 brackets TSP-WMK03 85.0 (3.35) 42.5 (1.67) 34.5 (1.36) 34.5 (1.36) R 2.12 (0.083) 7.0 (0.28) 15.0 (0.59) 37.0 (1.45) 25.0 (0.98) 25.0 (0.98) 74.0 (2.91) 2.0 (0.08) 55.0 (2.16) 4 x positioning holes 2.0 (0.08) 2.0 (0.08) R 2.12 (0.083) TSP 070 TSP 090 TSP 140 TSP 180 2.0 (0.08) o 4.25 (0.17) R 2.12 (0.083) o 4.25 (0.17) R 2.12 (0.083) o 4.25 (0.17) 15.0 (0.59) Material: 2 mm Mild Steel Tolerance: 0.1mm ( 0.004) TSP-WMK02 46.0 (1.81) TSP 360 33.0 (1.30) 96.0 (3.78) 62.5 (2.46) 50.0 (1.97) o 4.3 (0.17) 2x o4.3 (0.17) 2.0 (0.08) 30.0 (1.18) 2.0 (0.08) 25 (0.98) 4 x positioning holes TSP 600 Material: 2 mm Mild Steel Tolerance: 0.1mm ( 0.004) 62.5 (2.46) 15.0 (0.59) 7.0 (0.28) 173.0 (6.81) Dimensions in [mm], ( ) = Inch Tolerances: 0.5 mm (0.02) Dimensions: [mm] ( ) = Inch Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www.tracopower.com Rev. June 13. 2013 Page 15 of 15