Suitable for handling low signals in
computer peripherals, telecommunica-
tions and security equipment
Capable of switching loads up to 2 A
Conforms to FCC part 68 1500 V surge
withstand
Reliable bifurcated crossbar contacts
Fully-sealed construction
Low Signal Relay G5V-2
Ordering Information
Specifications
CONTACT DATA
Load Resistive load (p.f. = 1)
Rated load 0.50 A at 125 VAC
2 A at 30 VDC
Contact material Ag (Au clad)
Carry current 2 A
Max. operating voltage 125 VAC
125 VDC
Max. operating current 2 A
Max. switching capacity 62.50 VA
60W
Min. permissible load 10 µA, 10 mVDC
To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-2-
DC12
).
Type Contact form Construction Par t number
Standard DPDT Fully-sealed G5V-2
High-sensitivity G5V-2-H
Ultra-sensitive G5V-2-H1
2
G5V-2 G5V-2
Rated Rated Coil Coil inductance Pick-up Dropout Maximum Power
voltage current resistance (Ref. value) (H) voltage voltage voltage consumption
(VDC) (mA) ()Ar mature OFF Armature ON % of rated voltage (mW)
3 120 25 0.04 0.07 75% max. 5% min. 120% max. Approx. 360
5 72 70 0.12 0.19 at 70°C
6 60 100 0.18 0.29 (158°F)
9 40 225 0.40 0.62
12 30 400 0.75 1.18
24 15 1,600 3.16 4.81
48 7.5 6,400 110% max.
at 70°C
(158°F)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
High-sensitivity type
Ultra-sensitive type
COIL DATA
Standard type
Rated Rated Coil Coil inductance Pick-up Dropout Maximum Power
voltage current resistance (Ref. value) (H) voltage voltage voltage consumption
(VDC) (mA) ()Ar mature OFF Armature ON % of rated voltage (mW)
3 166.70 18 0.04 0.05 75% max. 5% min. 120% max. Approx. 500
5 100 50 0.09 0.11 at 65°C
6 83.30 72 0.16 0.19 (149°F)
9 55.60 162 0.31 0.49
12 41.70 288 0.47 0.74
24 20.80 1,152 1.98 2.68
48 12 4,000 110% max. Approx. 580
at 60°C
(140°F)
Rated Rated Coil Coil inductance Pick-up Dropout Maximum Power
voltage current resistance (Ref. value) (H) voltage voltage voltage consumption
(VDC) (mA) ()Ar mature OFF Armature ON % of rated voltage (mW)
3 50 60 0.18 0.26 75% max. 5% min. 150% max. Approx. 150
5 30 166.70 0.46 0.71 at 70°C
6 25 240 0.70 0.97 (158°F)
9 16.70 540 1.67 2.33
12 12.50 960 2.90 3.99
24 8.30 2,880 6.72 9.27 Approx. 200
48 6.25 7,680 20.10 26.70 Approx. 300
3
G5V-2 G5V-2
Contact resistance 50 m max. G5V-2, G5V-2-H, 100 m max. G5V-2-H1
Operate time 7 ms max. (mean value: approx. 3.5 ms)
Release time 3 ms max. (mean value: approx. 0.8 ms)
Bounce time Operate Mean value: approx. 0.5 ms
Release Mean value: approx. 3.5 ms
Operating frequency Mechanical 36,000 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 M min (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for
ultra-sensitive type)
Surge withstand voltage 1,500 V 10 X 160 µs (conforms to part 68 of FCC rules)
Vibration Mechanical durability 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude
Malfunction durability
Shock Mechanical durability 1,000 m/s2 (approx. 100 G)
Malfunction durability 200 m/s2 (approx. 20 G)
Ambient temperature Operating/storage -25° to 70°C (-13° to 158°F)
Humidity 35% to 85% RH
Ser vice life Mechanical 15 million operations min. (at operating frequency of 36,000 operations/hour)
Electrical See “Characteristic Data”
Weight 6 g (0.21 oz)
CHARACTERISTICS
CHARACTERISTIC DATA
Maximum switching capacity Electrical service life Ambient temperature vs.
maximum voltage
Rated operating current (A)
Rated operating voltage (V)
Service life (x10
3
operations)
Rated operating current (A)
Maximum voltage (%)
Ambient temperature [°C (°F)]
---- 48 VDC coil voltage (standard type)
All other types and voltages
Note: Data shown are of initial value.
4
G5V-2 G5V-2
Dimensions
Unit: mm (inch)
Fully-sealed Terminal arrangement/Internal Mounting holes
(bottom view) (bottom view)
Type Contact form Coil rating Contact ratings
G5V-2 DPDT 3 to 48 VDC 0.6 A, 125 VAC
G5V-2-H 3 to 24 VDC 0.6 A,110 VDC
2.0 A, 30 VDC
G5V-2-H1 3 to 48 VDC 0.6 A, 125 VAC
0.6 A, 110 VDC
1.0 A, 24 VDC
APPROVALS
UL (File No. E41515)/CSA (File No. LR24825)
Note: 1. and indicate mounting orientation marks.
2. A tolerance of ±0.10 (0.004) applies to the above dimensions.
123456
1
2345
6
123456
RELAYS
Note: 1. The rated v alues approved by each of the safety standards may be different from the perf ormance characteristics individually
defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
3. Complies with UL1950 Basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external
spacings).
OMRON ELECTRONICS, INC. OMRON CANADA, INC.
One East Commerce Drive 885 Milner Avenue
Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8
1-800-55-OMRON 416-286-6465
Cat. No. GC RLY7 01/00 Specifications subject to change without notice. Printed in the U.S.A.
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.