SG73
anti-surge thick film chip resistor
applications and ratings
Additional environmental applications can also be found at www.koaspeer.com
Parentheses indicate EIA package size codes.
Absolute
Maximum
Working
Voltage
Resistance
Range
(E-12)
(K±10%, M±20%)
SG731J
(0603)
SG732E
(1210)
SG732H/W2H
(2010)
SG733A/W3A
(2512)
±400
±200
±400
Part
Designation
Absolute
Maximum
Overload
Voltage
Operating
Temp.
Range
Power
Rating
@ 70°C
T.C.R.
(ppm/°C)
Max.
0.1W
.33W
0.5W
150V 200V
-55°C
to
+155°C
SG732B
(1206)
SG732A
(0805) ±200
1Ω - 8.2Ω
0.125W
50V 100V
10Ω - 1MΩ
1Ω - 8.2Ω
10Ω - 1MΩ
200V 400V
Rated
Terminal
Part Temp.
Rated
Ambient
Temp.
±200
±400 1Ω - 8.2Ω
10Ω - 1MΩ
±200
±400 1Ω - 8.2Ω
10Ω - 1MΩ
0.75W ±200
±400 1Ω - 8.2Ω
10Ω - 1MΩ
1W
70°C
70°C
70°C
70°C
70°C
70°C
125°C
125°C
125°C
125°C
125°C
125°C ±200
±400 1Ω - 8.2Ω
10Ω - 1MΩ
Rated voltage = √Power rating x resistance value or max. working voltage, whichever is lower
environmental applications
Derating Curve
% Rated Power
100
80
60
40
20
-60 -40 04060 80 100 160
70
20
Ambient Temperature
(°C)
0
-55
120
155
-20 140
% Rated Power
100
80
60
40
20
-60 -40 80
100
16020
(°C)
0
-55 120 155
-20 140
125
04060
Terminal Part Temperature
1J, 2A, 2B,
2E, W2H, W3A
For resistors operated at an ambient temperature
of 70°C or above, a power rating shall be derated
in accordance with the derating curve.
For resistors operated at a terminal part temperature
of described for each size or above, a power rating
shall be derated in accordance with the derating curve.
Please refer to “Introduction of the derating curve based
on the terminal part temperature” in the beginning
of our catalog before use.
SG73 SG73
51
KOA Speer Electronics, Inc. • 199 Bolivar Drive • Bradford, PA 16701 • USA • 814-362-5536 • Fax: 814-362-8883 • www.koaspeer.com
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use. 11/16/16
resistors
If any questions should arise whether to use the “Rated Ambient Temperature” or the “Rated Terminal Part Temperature,” please give priority to the
“Rated Terminal Part Temperature.” Prior to use and for more details refer to “Introduction of the derating curves on the terminal part temperature”
in the beginning of the catalog.
One-Pulse Limiting Electric Power
One-Pulse Limiting Electric Power
100000
100
.1 100
3A
1
Pulse Duration
(ms)
10001.001
10000
1000
10
10.01
2H
2E
2B
2A
1J
SG73
Performance Characteristics
Parameter
Requirement ∆ R ±(%+0.1Ω)
Limit Typical Test Method
Resistance
T.C.R.
25°C
+25°C/-55°C and +25°C/+125°C
Within specified
tolerance
Within specified
T.C.R.
—
—
Overload (Short time) Rated Voltage x 2.5 for 5 seconds
±2% ±0.5%
Resistance to Solder Heat 260°C ± 5°C, 10 seconds ± 1 second
±1% ±0.75%
Rapid Change of Temperature -55°C (30 minutes), +125°C (30 minutes), 100 cycles
±0.5% ±0.3%
Moisture Resistance 40°C ± 2°C, 90%~95%RH, 1000 hours; 1.5 hr ON, 0.5 hr OFF cycle
±3% ±0.75%
Endurance at 70°C 70°C ± 2°C, 1000 hours, 1.5 hr ON, 0.5 hr OFF cycle
±3% ±0.75%
High Temperature Exposure +155°C, 1000 hours
±1% ±0.3%
The maximum applicable voltage is equal
to the max. overload voltage. Please contact
factory for resistance characteristics of
continuous applied pulse.