MTC1 Series
Isolated 1W SM 2:1 Input Single Output DC-DC Converters
KDC_MTC1.E01 Page 1 of 12
All enquiries: www.murata-ps.com/support
www.murata-ps.com
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
SELECTION GUIDE
Order Code1
Input
Voltage
Output
Voltage
Output
Current
Rated Input
Current
Efficiency Ripple and
Noise MTTF2
Nom. Min. Typ. Typ. Max. MIL Telecordia
V V mA mA % % mVp/p mVp/p kHrs kHrs
MTC1S1203MC 12 3.3 303 110 72 75 25 50 1143 17407
MTC1S1205MC 12 5 200 110 77 78.5 25 50 1129 17407
MTC1S1212MC 12 12 83 100 77 79 20 40 977 17407
MTC1S2403MC 24 3.3 303 55 73 75.5 30 55 1042 17109
MTC1S2405MC 24 5 200 55 74 76.5 25 50 990 17109
MTC1S2412MC 24 12 83 55 75 77 25 50 833 17109
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range
12V input types 9 12 18
V
24V input types 18 24 36
Input reflected ripple
current All variants 2 mA p-p
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation test voltage Production tested for 1 second 3000 VAC
Qualification tested for 1 minute 3000 VAC
Isolation capacitance All variants 7 pF
Resistance Viso = 1kVDC 1 GΩ
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated power All output types 1 W
Minimal load to meet datasheet specification 10 %
Voltage set point accuracy 3V, 5V output types -2.5 2 %
12V output types -3 2
Line regulation Low line to high line ±0.05 ±0.2 %
Load regulation All output types ±0.25 ±0.5 %
Transient response
Peak deviation (25-75%
& 75-25% swing)
2403 variant ±4
%Vout
2405 variant ±3
All other variants ±2
Settling time
(within 5% Vout Nom.)
1203 220
s
1205 260
1212, 2403 & 2405 100
2412 70
1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are
MTC1SXXXXMC-R7 (30 pieces per reel), or MTC1SXXXXMC-R13 (150 pieces per reel)
2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
FEATURES
UL 60950 recognised for reinforced
insulation
ANSI/AAMI ES60601-1, 1 MOPP/ 2 MOOPs
recognised
3kVAC isolation test voltage ‘Hi Pot Test’
Continuous short circuit protection
Output Voltage Trim
Remote on/off pin
No electrolytic capacitors
Operating temperature range -40°C to
100°C
2:1 Input Range
PRODUCT OVERVIEW
The MTC1 series of miniature surface mount DC-
DC converters offers a single output voltage from
input voltage ranges of 9-18V and 18-36V. The
MTC1 series regulated output voltage is adjust-
able by ±10% and a remote on/off pin is also
included for application power saving.
The MTC1 ideally suited to applications which
include medical. Industrial, telecommunications,
battery powered systems, and process automa-
tion.