9312/DM9312 One of Eight Line Data Selectors/Multiplexers General Description Features These data selectors/multiplexers contain inverter/drivers to supply full complementary, on-chip, binary decoded data selection. The 9312 is a single 8-bit multiplexer with complementary outputs and a strobe control. When the strobe is low, the function is enabled. When a high logic level is applied to the strobe, the output is forced to the logic zero state regardless of the logic level of the data inputs. Y Y Y Y Selects one-of-eight data sources Performs parallel to serial conversion Strobe controlled outputs Complementary outputs Connection Diagram Dual-In-Line Package TL/F/6605 - 1 Order Number 9312DMQB, 9312FMQB or DM9312N See NS Package Number J16A, N16E or W16A Function Table Inputs Select Outputs Strobe C B A G X L L L L H H H H X L L H H L L H H X L H L H L H L H H L L L L L L L L Y Y L D0 D1 D2 D3 D4 D5 D6 D7 H D0 D1 D2 D3 D4 D5 D6 D7 H e High Level, L e Low Level, X e Don't Care. D0, D1 . . . D7 e The level of the respective D input. C1995 National Semiconductor Corporation TL/F/6605 RRD-B30M105/Printed in U. S. A. 9312/DM9312 One of Eight Line Data Selectors/Multiplexers June 1989 Absolute Maximum Ratings (Note) Note: The ``Absolute Maximum Ratings'' are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the ``Electrical Characteristics'' table are not guaranteed at the absolute maximum ratings. The ``Recommended Operating Conditions'' table will define the conditions for actual device operation. If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/Distributors for availability and specifications. Supply Voltage 7V Input Voltage 5.5V Operating Free Air Temperature Range b 55 C to a 125 C Military Commercial 0 C to a 70 C Storage Temperature Range b 65 C to a 150 C Recommended Operating Conditions Symbol Military Parameter VCC Supply Voltage VIH High Level Input Voltage VIL Low Level Input Voltage IOH High Level Output Current IOL Low Level Output Current TA Free Air Operating Temperature Commercial Units Min Nom Max Min Nom Max 4.5 5 5.5 4.75 5 5.25 2 2 V 0.8 0.8 V b 0.8 b 0.8 mA 16 mA 70 C 16 b 55 V 125 0 Electrical Characteristics over recommended operating free air temperature range (unless otherwise noted) Symbol Parameter Conditions VI Input Clamp Voltage VCC e Min, II e b12 mA VOH High Level Output Voltage VCC e Min, IOH e Max VIL e Max, VIH e Min VOL Low Level Output Voltage VCC e Min, IOL e Max VIH e Min, VIL e Max II Input Current @ Max Input Voltage IIH Min 2.4 Typ (Note 1) Max Units b 1.5 V 3.4 0.4 V VCC e Max, VI e 5.5V 1 mA High Level Input Current VCC e Max, VI e 2.4V 40 mA IIL Low Level Input Current VCC e Max, VI e 0.4V b 1.6 mA IOS Short Circuit Output Current VCC e Max (Note 2) Supply Current VCC e Max, (Note 3) ICC 0.2 V MIL b 20 b 70 COM b 30 b 85 Note 1: All typicals are at VCC e 5V, TA e 25 C. Note 2: Not more than one output should be shorted at a time. Note 3: ICC is measured with the STROBE and DATA SELECT inputs 4.5V and all other inputs and outputs open. 2 27 44 mA mA Switching Characteristics at VCC e 5V and TA e 25 C (See Section 1 for Test Waveforms and Output Load) Symbol Parameter Military From (Input) To (Output) Commercial RL e 400X, CL e 15 pF Min Max Min Units Max tPLH Propagation Delay Time Low to High Level Output Selectz to Y 34 33 ns tPHL Propagation Delay Time High to Low Level Output Select to Y 34 35 ns tPLH Propagation Delay Time Low to High Level Output Select to Y 24 28 ns tPHL Propagation Delay Time High to Low Level Output Select to Y 26 25 ns tPLH Propagation Delay Time Low to High Level Output Data to Y 24 23 ns tPHL Propagation Delay Time High to Low Level Output Data to Y 24 25 ns tPLH Propagation Delay Time Low to High Level Output Data to Y 14 13 ns tPHL Propagation Delay Time High to Low Level Output Data to Y 16 13 ns tPLH Propagation Delay Time Low to High Level Output Strobe to Y 30 33 ns tPHL Propagation Delay Time High to Low Level Output Strobe to Y 30 32 ns tPLH Propagation Delay Time Low to High Level Output Strobe to Y 20 19 ns tPHL Propagation Delay Time High to Low Level Output Strobe to Y 23 21 ns 3 Logic Diagram 9312 TL/F/6605 - 2 4 Physical Dimensions inches (millimeters) 16-Lead Ceramic Dual-In-Line Package (J) Order Number 9312DMBQ NS Package Number J16A 16-Lead Molded Dual-In-Line Package (N) Order Number DM9312N NS Package Number N16E 5 9312/DM9312 One of Eight Line Data Selectors/Multiplexers Physical Dimensions inches (millimeters) (Continued) 16-Lead Ceramic Flat Package (W) Order Number 9312FMQB NS Package Number W16A LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. National Semiconductor Corporation 1111 West Bardin Road Arlington, TX 76017 Tel: 1(800) 272-9959 Fax: 1(800) 737-7018 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. National Semiconductor Europe Fax: (a49) 0-180-530 85 86 Email: cnjwge @ tevm2.nsc.com Deutsch Tel: (a49) 0-180-530 85 85 English Tel: (a49) 0-180-532 78 32 Fran3ais Tel: (a49) 0-180-532 93 58 Italiano Tel: (a49) 0-180-534 16 80 National Semiconductor Hong Kong Ltd. 13th Floor, Straight Block, Ocean Centre, 5 Canton Rd. Tsimshatsui, Kowloon Hong Kong Tel: (852) 2737-1600 Fax: (852) 2736-9960 National Semiconductor Japan Ltd. Tel: 81-043-299-2309 Fax: 81-043-299-2408 National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.