ACPL-330J 1.5 Amp Output Current IGBT Gate Driver Optocoupler with Integrated (VCE) Desaturation Detection, UVLO, Fault Feedback, Active Miller Clamp and Auto-Fault Reset Data Sheet Lead (Pb) Free RoHS 6 fully compliant RoHS 6 fully compliant options available; -xxxE denotes a lead-free product Description Features The ACPL-330J is an advanced 1.5 A output current, easyto-use, intelligent gate driver which makes IGBT VCE fault protection compact, affordable, and easy-to implement. Features such as integrated VCE detection, under voltage lockout (UVLO), "soft" IGBT turn-off, isolated open collector fault feedback and active Miller clamping provide maximum design flexibility and circuit protection. * 1.5 A maximum peak output current The ACPL-330J contains a AlGaAs LED. The LED is optically coupled to an integrated circuit with a power output stage. ACPL-330J is ideally suited for driving power IGBTs and MOSFETs used in motor control inverter applications. The voltage and current supplied by these optocouplers make them ideally suited for directly driving IGBTs with ratings up to 1200 V and 100 A. For IGBTs with higher ratings, the ACPL-330J can be used to drive a discrete power stage which drives the IGBT gate. The ACPL-330J has an insulation voltage of VIORM = 1414 VPEAK. * Desaturation Detection Block Diagram * 50 kV/s minimum common mode rejection (CMR) at VCM = 1500 V 13 V CC2 UVLO ANODE CATHODE 6, 7 D R I V E R 5, 8 LED1 11 14 V OUT DESAT DESAT 9, 12 SHIELD V EE V CLAMP V CC1 FAULT VS 2 10 LED2 3 16 1, 4 15 SHIELD V CLAMP VE * 1.0 A minimum peak output current * 250 ns maximum propagation delay over temperature range * 1.0A Active Miller Clamp. Clamp pin short to VEE if not in used * Miller Clamping * Under Voltage Lock-Out Protection (UVLO) with Hysteresis * Open Collector Isolated fault feedback * "Soft" IGBT Turn-off * Automatic Fault Reset after fixed Mute Time , typically 26ms * Available in SO-16 package * 100 ns maximum pulse width distortion (PWD) * ICC(max) < 5 mA maximum supply current * Wide VCC operating range: 15 V to 30 V over temperature range * Wide operating temperature range: -40C to 105C * Safety Approvals: UL, 5000 VRMS for 1 minute, CSA Approval, IEC/EN/DIN-EN 60747-5-5 VIORM = 1414 VPEAK Applications * Isolated IGBT/Power MOSFET gate drive * AC and brushless DC motor drives V LED * Industrial inverters and Uninterruptible Power Supply (UPS) CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD. The components featured in this datasheet are not to be used in military or aerospace applications or environments. Pin Description 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE 7 8 ANODE CATHODE VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 VOUT 11 VCLAMP 10 VEE 9 Pin Symbol Description 1 VS Input Ground 2 VCC1 Positive input supply voltage. (3.3 V to 5.5 V) 3 FAULT Fault output. FAULT changes from a high impedance state to a logic low output within 5 s of the voltage on the DESAT pin exceeding an internal reference voltage of 6.5 V. FAULT output is an open collector which allows the FAULT outputs from all ACPL-330J in a circuit to be connected together in a "wired OR" forming a single fault bus for interfacing directly to the micro-controller. 4 VS Input Ground 5 CATHODE Cathode 6 ANODE Anode 7 ANODE Anode 8 CATHODE Cathode 9 VEE Output supply voltage. 10 VCLAMP Miller clamp 11 VOUT Gate drive voltage output 12 VEE Output supply voltage. 13 VCC2 Positive output supply voltage 14 DESAT Desaturation voltage input. When the voltage on DESAT exceeds an internal reference voltage of 6.5 V while the IGBT is on, FAULT output is changed from a high impedance state to a logic low state within 5 s. 15 VLED LED anode. This pin must be left unconnected for guaranteed data sheet performance. (For optical coupling testing only) 16 VE Common (IGBT emitter) output supply voltage. Ordering Information ACPL-330J is UL Recognized with 5000 Vrms for 1 minute per UL1577. Option Part number RoHS Compliant Package ACPL-330J -000E SO-16 -500E Surface Mount Tape& Reel X X X IEC/EN/DIN EN 60747-5-5 Quantity X 45 per tube X 850 per reel To order, choose a part number from the part number column and combine with the desired option from the option column to form an order entry. Example 1: ACPL-330J-500E to order product of SO-16 Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-5 Safety Approval in RoHS compliant. Example 2: ACPL-330J-000E to order product of SO-16 Surface Mount package in tube packaging with IEC/EN/DIN EN 60747-5-5 Safety Approval and RoHS compliant. Option datasheets are available. Contact your Avago sales representative or authorized distributor for information. Remarks: The notation `#XXX' is used for existing products, while (new) products launched since 15th July 2001 and RoHS compliant option will use `-XXXE`. 2 Package Outline Drawings 16-Lead Surface Mount 0.457 (0.018) LAND PATTERN RECOMMENDATION 1.270 (0.050) 16 15 14 13 12 11 10 0.64 (0.025) 9 TYPE NUMBER DATE CODE A XXXX YYWW EEE AVAGO LEAD-FREE 7.493 0.254 (0.295 0.010) PIN 1 DOT 11.63 (0.458) LOT ID 2.16 (0.085) 1 2 3 4 5 6 7 8 10.312 0.254 (0.406 0.10) 8.763 0.254 (0.345 0.010) 9 0.457 (0.018) Dimensions in Millimeters (Inches) 3.505 0.127 (0.138 0.005) 0-8 0.64 (0.025) MIN. 10.363 0.254 (0.408 0.010) ALL LEADS TO BE COPLANAR 0.05 (0.002) 0.203 0.076 (0.008 0.003) STANDOFF Floating lead protrusion is 0.25 mm (10 mils) Max. Note: Initial and continued variation in color of the white mold compound is normal and does not affect performance or reliability of the device 3 Recommended Pb-Free IR Profile Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used. Regulatory Information The ACPL-330J has been approved by the following organizations: IEC/EN/DIN EN 60747-5-5 Approval under: DIN EN 60747-5-5 (VDE 0884-5):2011-11 EN 60747-5-5:2011 Approval under UL 1577, component recognition program up to VISO = 5000 VRMS. File E55361. UL Approval under CSA Component Acceptance Notice #5, File CA 88324. CSA Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* Description Symbol Characteristic Installation classification per DIN VDE 0110/39, Table 1 for rated mains voltage 150 Vrms for rated mains voltage 300 Vrms for rated mains voltage 600 Vrms for rated mains voltage 1000Vrms I - IV I - IV I - IV I - III Climatic Classification 40/100/21 Pollution Degree (DIN VDE 0110/39) 2 Unit Maximum Working Insulation Voltage VIORM 1414 Vpeak Input to Output Test Voltage, Method b**, VIORM x 1.875=VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC VPR 2652 Vpeak Input to Output Test Voltage, Method a**, VIORM x 1.6=VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC VPR 2262 Vpeak Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec) VIOTM 8000 Vpeak Case Temperature TS 175 C Input Current IS, INPUT 400 mA Output Power PS, OUTPUT 1200 mW RS >109 W Safety-limiting values - maximum values allowed in the event of a failure Insulation Resistance at TS, VIO = 500 V * Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application. Surface mount classification is class A in accordance with CECCOO802. ** Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Avago Regulatory Guide to Isolation Circuits, AV02-2041EN for a detailed description of Method a and Method b partial discharge test profiles. Dependence of Safety Limiting Values on Temperature. (take from DS AV01-0579EN Pg.7) 1400 PS , OUTPUT PS , INPUT 1200 PS - POWER - mW 1000 800 600 400 200 0 4 0 25 50 125 150 75 100 TS - CASE TEMPERATURE - C 175 200 Table 2. Insulation and Safety Related Specifications Parameter Symbol ACPL-330J Units Conditions Minimum External Air Gap (Clearance) L(101) 8.3 mm Measured from input terminals to output terminals, shortest distance through air. Minimum External Tracking (Creepage) L(102) 8.3 mm Measured from input terminals to output terminals, shortest distance path along body. 0.5 mm Through insulation distance conductor to conductor, usually the straight line distance thickness between the emitter and detector. >175 V DIN IEC 112/VDE 0303 Part 1 Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance (Comparative Tracking Index) CTI Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Table 3. Absolute Maximum Ratings Parameter Symbol Min. Max. Units Note Storage Temperature TS -55 125 C Operating Temperature TA -40 105 C 2 Output IC Junction Temperature TJ 125 C 2 Average Input Current IF(AVG) 25 mA 1 Peak Transient Input Current (<1 s pulse width, 300pps) IF(TRAN) 1.0 A Reverse Input Voltage VR 5 V "High" Peak Output Current IOH(PEAK) 1.5 A 3 "Low" Peak Output Current IOL(PEAK) 1.5 A 3 Positive Input Supply Voltage VCC1 -0.5 7.0 V FAULT Output Current IFAULT 8.0 FAULT Pin Voltage VFAULT -0.5 VCC1 V Total Output Supply Voltage (VCC2 - VEE) -0.5 33 V Negative Output Supply Voltage (VE - VEE) -0.5 15 V Positive Output Supply Voltage (VCC2 - VE) -0.5 33 - (VE - VEE) V Gate Drive Output Voltage VO(PEAK) -0.5 VCC2 V Peak Clamping Sinking Current IClamp 1.0 A Miller Clamping Pin Voltage VClamp -0.5 VCC2 V DESAT Voltage VDESAT VE VE + 10 V Output IC Power Dissipation PO 600 mW 2 Input IC Power Dissipation PI 150 mW 2 Solder Reflow Temperature Profile See Package Outline Drawings section mA 6 Table 4. Recommended Operating Conditions Parameter Symbol Min. Max. Units Note Operating Temperature TA - 40 105 C 2 Total Output Supply Voltage (VCC2 - VEE) 15 30 V 7 Negative Output Supply Voltage (VE - VEE) 0 15 V 4 Positive Output Supply Voltage (VCC2 - VE) 15 30 - (VE - VEE) V Input Current (ON) IF(ON) 8 12 mA Input Voltage (OFF) VF(OFF) - 3.6 0.8 V 5 Table 5. Electrical Specifications (DC) Unless otherwise noted, all typical values at TA = 25C, VCC2 - VEE = 30 V, VE - VEE = 0 V; all Minimum/Maximum specifications are at Recommended Operating Conditions. Parameter Symbol FAULT Logic Low Output Voltage VFAULTL FAULT Logic High Output Current IFAULTH High Level Output Current IOH Low Level Output Current IOL Low Level Output Current During Fault Condition IOLF 90 High Level Output Voltage VOH VCC-2.9 VCC-2.0 Low Level Output Voltage VOL 0.17 Clamp Pin Threshold Voltage VtClamp 2.0 V Clamp Low Level Sinking Current ICL 0.7 A VO = VEE + 2.5 High Level Supply Current ICC2H 2.5 5 mA IO = 0 mA Low Level Supply Current ICC2L 2.5 5 mA IO = 0 mA Blanking Capacitor Charging Current ICHG 0.13 -0.24 -0.33 mA Blanking Capacitor Discharge Current IDSCHG 10 30 DESAT Threshold VDESAT 6 6.5 UVLO Threshold VUVLO+ 10.5 VUVLOUVLO Hysteresis (VUVLO+ - VUVLO-) Threshold Input Current Low to High IFLH Threshold Input Voltage High to Low VFHL 0.8 Input Forward Voltage VF 1.2 Temperature Coefficient of Input Forward Voltage DVF/DTA Input Reverse Breakdown Voltage BVR Input Capacitance CIN 6 Min. -0.3 Typ. Max. Units Test Conditions 0.1 0.4 V IFAULT = 1.1 mA, VCC1 = 5.5V 0.1 0.4 V IFAULT = 1.1 mA, VCC1 = 3.3V 0.02 0.5 A VFAULT = 5.5 V, VCC1 = 5.5V 0.002 0.3 A VFAULT = 3.3 V, VCC1 = 3.3V A VO = VCC2 - 4 A VO = VCC2 - 15 A VO = VEE + 2.5 A VO = VEE + 15 3 mA VOUT - VEE = 14 V 6 V IO = -650 A 2, 4, 20 V IO = 100 mA 3, 5, 21 -0.75 -1.0 0.3 0.75 1.0 0.21 140 230 0.5 Fig. Note 4, 18 5 3 5, 19 5 7, 8,9 23 6, 7, 23 9 VDESAT = 2 V 8, 24 9, 10 mA VDESAT = 7.0 V 25 7.5 V VCC2 -VE >VUVLO- 9, 27 11.6 12.5 V VO > 5 V 7, 9, 11 9.2 10.3 11.1 V VO < 5 V 7, 9, 12 0.4 1.3 2.0 V 6 mA IO = 0 mA, VO > 5 V V 1.6 -1.3 5 70 1.95 V IF = 10 mA mV/C V IR = 10 A pF f = 1 MHz, VF = 0 V 9 Table 6. Switching Specifications (AC) Unless otherwise noted, all typical values at TA = 25C, VCC2 - VEE = 30 V, VE - VEE = 0 V; all Minimum/Maximum specifications are at Recommended Operating Conditions. Parameter Symbol Min. Typ. Max. Units Test Conditions Fig. Note Propagation Delay Time to High Output Level tPLH 100 180 250 ns tPHL 100 180 250 ns 1, 10, 11, 12, 13, 26 13, 15 Propagation Delay Time to Low Output Level Rg = 20 W, Cg = 5 nF, f = 10 kHz, Duty Cycle = 50%, IF = 10 mA, VCC2 = 30 V Pulse Width Distortion PWD -100 20 100 ns 14, 17 Propagation Delay Difference Between Any Two Parts or Channels (tPHL - tPLH) PDD -150 150 ns 17, 16 Rise Time tR 50 ns Fall Time tF 50 ns DESAT Sense to 90% VO Delay tDESAT(90%) 0.15 0.3 s CDESAT = 100pF, RF=2.1k, Rg = 20 W, Cg = 5 nF, VCC2 = 30 V 14, 27, 34 DESAT Sense to 10% VO Delay tDESAT(10%) 1.1 1.5 s CDESAT = 100pF, RF=2.1k , Rg = 20 W, Cg = 5 nF, VCC2 = 30 V 15, 16, 17, 27, 34 DESAT Sense to Low Level FAULT Signal Delay tDESAT(FAULT) 0.25 0.5 s CDESAT = 100 pF, RF = 2.1 k, CF = Open, Rg = 20 , Cg = 5 nF, VCC2 = 30 V 27, 34 18 0.8 DESAT Sense to DESAT Low Propagation Delay tDESAT(LOW) DESAT Input Mute tDESAT(MUTE) 15 26 Output High Level Common Mode Transient Immunity |CMH| 15 25 50 60 15 25 50 60 Output Low Level Common Mode Transient Immunity 7 |CML| 19 CDESAT = 100 pF, RF = 2.1 k, CF = 1 nF, Rg = 20 , Cg = 5 nF, VCC2 = 30 V 0.25 40 s CDESAT = 100pF, RF = 2.1 kW, Rg = 20 W, Cg = 5 nF, VCC2 = 30 V 27, 34 19 s CDESAT = 100pF, RF = 2.1 kW, Rg = 20 W, Cg = 5 nF, VCC1 = 5.5V, VCC2 = 30 V 34 20 kV/s TA = 25C, IF = 10 mA VCM = 1500 V, VCC2 = 30 V, RF = 2.1 k, CF = 15 pF 28, 29, 30, 31 21 TA = 25C, IF = 10 mA VCM = 1500 V, VCC2 = 30 V, RF = 2.1 k, CF = 1 nF kV/s TA = 25C, VF = 0 V VCM = 1500 V, VCC2 = 30 V, RF = 2.1 k, CF = 15 pF TA = 25C, VF = 0 V VCM = 1500 V, VCC2 = 30 V, RF = 2.1 k, CF = 1 nF 21, 26 28, 29, 30, 31 22 Table 7. Package Characteristics Parameter Symbol Min. Input-Output Momentary Withstand Voltage VISO 5000 Input-Output Resistance RI-O Input-Output Capacitance Output IC-to-Pins 9 &10 Thermal Resistance Typ. Max. Units Test Conditions Fig. Note Vrms RH < 50%, t = 1 min., TA = 25C 24, 25 > 109 W VI-O = 500 V 25 CI-O 1.3 pF freq=1 MHz q09-10 30 C/W TA = 25C Notes: 1. Derate linearly above 70C free air temperature at a rate of 0.3 mA/C. 2. In order to achieve the absolute maximum power dissipation specified, pins 4, 9, and 10 require ground plane connections and may require airflow. See the Thermal Model section in the application notes at the end of this data sheet for details on how to estimate junction temperature and power dissipation. In most cases the absolute maximum output IC junction temperature is the limiting factor. The actual power dissipation achievable will depend on the application environment (PCB Layout, air flow, part placement, etc.). See the Recommended PCB Layout section in the application notes for layout considerations. Output IC power dissipation is derated linearly at 10 mW/C above 90C. Input IC power dissipation does not require derating. 3. Maximum pulse width = 10 s. This value is intended to allow for component tolerances for designs with IO peak minimum = 1.0 A. Derate linearly from 2.0 A at +25C to 1.5 A at +105C. This compensates for increased IOPEAK due to changes in VOL over temperature. 4. This supply is optional. Required only when negative gate drive is implemented. 5. Maximum pulse width = 50 s. 6. See the Slow IGBT Gate Discharge During Fault Condition section in the applications notes at the end of this data sheet for further details. 7. 15 V is the recommended minimum operating positive supply voltage (VCC2 - VE) to ensure adequate margin in excess of the maximum VUVLO+ threshold of 12.5 V. For High Level Output Voltage testing, VOH is measured with a dc load current. When driving capacitive loads, VOH will approach VCC as IOH approaches zero units. 8. Maximum pulse width = 1.0 ms. 9. Once VO of the ACPL-330J is allowed to go high (VCC2 - VE > VUVLO+), the DESAT detection feature of the ACPL-330J will be the primary source of IGBT protection. UVLO is needed to ensure DESAT is functional. Once VCC2 is increased from 0V to above VUVLO+, DESAT will remain functional until VCC2 is decreased below VUVLO-. Thus, the DESAT detection and UVLO features of the ACPL-330J work in conjunction to ensure constant IGBT protection. 10. See the DESAT fault detection blanking time section in the applications notes at the end of this data sheet for further details. 11. This is the "increasing" (i.e. turn-on or "positive going" direction) of VCC2 - VE 12. This is the "decreasing" (i.e. turn-off or "negative going" direction) of VCC2 - VE 13. This load condition approximates the gate load of a 1200 V/75A IGBT. 14. Pulse Width Distortion (PWD) is defined as |tPHL - tPLH| for any given unit. 15. As measured from IF to VO. 16. The difference between tPHL and tPLH between any two ACPL-330J parts under the same test conditions. 17. As measured from ANODE, CATHODE of LED to VOUT 18. This is the amount of time from when the DESAT threshold is exceeded, until the FAULT output goes low. 19. This is the amount of time the DESAT threshold must be exceeded before VOUT begins to go low, and the FAULT output to go low. This is supply voltage dependent. 20. Auto Reset: This is the amount of time when VOUT will be asserted low after DESAT threshold is exceeded. See the Description of Operation (Auto Reset) topic in the application information section. 21. Common mode transient immunity in the high state is the maximum tolerable dVCM/dt of the common mode pulse, VCM, to assure that the output will remain in the high state (i.e., VO > 15 V or FAULT > 2 V). 22. Common mode transient immunity in the low state is the maximum tolerable dVCM/dt of the common mode pulse, VCM, to assure that the output will remain in a low state (i.e., VO < 1.0 V or FAULT < 0.8 V). 23. To clamp the output voltage at VCC - 3 VBE, a pull-down resistor between the output and VEE is recommended to sink a static current of 650 A while the output is high. See the Output Pull-Down Resistor section in the application notes at the end of this data sheet if an output pull-down resistor is not used. 24. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage 6000 Vrms for 1 second. This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/DIN EN 60747-5-5 Insulation Characteristic Table. 25. This is a two-terminal measurement: pins 1-8 are shorted together and pins 9-16 are shorted together. 26. Split resistors network with a ratio of 1:1 is needed at input LED1. See Figure 31. 8 IF tr tf 90% 50% V OUT 10% tPLH tPHL 0.25 0 ____IOUT = -650A VOL - OUTPUT LOW VOLTAGE - V (VOH - VCC) - HIGH OUTPUT VOLTAGE DROP - V Figure 1. Timing Curve -0.5 -1 -1.5 -2 -2.5 -40 -20 0 20 40 60 TA- TEMPERATURE -C 80 0.05 -20 0 20 40 60 TA- TEMPERATURE -C 80 105 Figure 3. VOL vs. temperature 4 _ _ _ _ 105C ______ 25C --------- -40C 29 VOL - OUTPUT LOW VOLTAGE - V V OH - HIGH OUTPUT VOLTAGE DROP - V 0.1 0 -40 30 28 27 26 0.0 Figure 4. VOH vs. IOH 9 0.15 105 Figure 2. VOH vs. temperature 25 0.2 0.2 0.4 0.6 0.8 IOH - OUTPUT HIGH CURRENT - A 1.0 _ _ _ _ 100C 25C --------- -40C 3 2 1 0 0 Figure 5. VOL vs. IOL 0.5 1 IOL - OUTPUT LOW CURRENT - A 1.5 2.65 ICC2 - OUTPUT SUPPLY CURRENT - mA ICC2 - OUTPUT SUPPLY CURRENT - mA 3.50 ICC2H ICC2L 3.25 3.00 2.75 2.50 2.25 2.00 -40 -20 0 20 40 60 TA- TEMPERATURE -C 80 VDESAT - DESAT THRESHOLD - V ICH - BLANKING CAPACITOR CHARGING CURRENT - mA -0.25 -0.30 -20 0 20 40 60 TA- TEMPERATURE -C 80 15 20 25 VCC2 - SUPPLY VOLTAGE - V 30 300 6.5 -20 0 20 40 60 TA- TEMPERATURE -C 300 TP - PROPAGATION DELAY - ns 250 200 150 0 80 105 Figure 9. DESAT threshold vs. temperature t PLH t PHL -20 7.0 6.0 -40 105 Figure 8. ICHG vs. temperature TP - PROPAGATION DELAY - ns 2.35 7.5 -0.35 -40 20 40 60 TA- TEMPERATURE -C Figure 10. Propagation delay vs. temperature 10 2.45 Figure 7. ICC2 vs. VCC2 -0.20 100 -40 2.55 2.25 105 Figure 6. ICC2 vs. temperature ICC2H ICC2L 80 105 t PLH t PHL 250 200 150 100 15 20 25 VCC - SUPPLY VOLTAGE - V Figure 11. Propagation delay vs. supply voltage 30 300 250 TP - PROPAGATION DELAY - ns t PLH t PHL 200 150 0 10 20 30 LOAD RESISTANCE - ohm 40 TDESAT90% - DESAT Sense to 90% Vo Delay - ns Figure 12. Propagation delay vs. load resistance 200 150 -20 0 20 40 60 TA- TEMPERATURE -C 80 105 TDESAT10% - DESAT Sense to 10% Vo Delay - us Figure 14. DESAT sense to 90% VOUT delay vs. temperature V cc2 =15V V cc2 =30V 2.0 1.0 0.0 10 20 30 40 LOAD RESISTANCE-ohm Figure 16. DESAT sense to 10% VOUT delay vs. load resistance 11 100 0 10 20 30 LOAD CAPACITANCE - nF 40 50 2.0 V cc2 =15V V cc2 =30V 1.5 1.0 0.5 0.0 -40 -20 0 20 40 60 TA- TEMPERATURE -C 80 105 Figure 15. DESAT sense to 10% VOUT delay vs. temperature 4.0 3.0 200 Figure 13. Propagation delay vs. load capacitance 250 100 -40 t PLH t PHL 0 50 TDESAT10% - DESAT Sense to 10% Vo Delay - us 100 50 TDESAT10% - DESAT Sense to 10% Vo Delay - ms TP - PROPAGATION DELAY - ns 300 0.012 V cc2 =15V V cc2 =30V 0.008 0.004 0.000 0 10 20 30 LOAD CAPACITANCE-nF 40 Figure 17. DESAT sense to 10% VOUT delay vs. load capacitance 50 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE 7 ANODE 8 CATHODE 10mA VE 16 VLED 15 DESAT 14 VCC2 13 0.1F 15V Pulsed VEE 12 IOUT VOUT 11 VCLAMP 10 VEE 9 +_ 0.1F +_ 30V Figure 18. IOH Pulsed test circuit 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 0.1F 15V Pulsed IOUT +_ 0.1F +_ 30V Figure 19. IOL Pulsed test circuit 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 10mA Figure 20. VOH Pulsed test circuit 12 0.1F VOUT 0.1F 650A +_ 30V 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 0.1F 100mA VOUT 0.1F +_ 30V Figure 21. VOL Pulsed test circuit 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 10mA 0.1F ICC2 0.1F +_ 30V Figure 22. ICC2H test circuit 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 Figure 23. ICC2L test circuit 13 0.1F ICC2 0.1F +_ 30V 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 VE 16 VLED 15 DESAT 14 ICHG 10mA 0.1F 0.1F +_ 30V Figure 24. ICHG Pulsed test circuit VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 VOUT 11 VCLAMP 10 VEE 9 +_ 1 7V 0.1F IDSCHG 0.1F +_ 30V Figure 25. IDSCHG test circuit 10mA, 10kHz, 50% Duty Cycle 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE 7 ANODE 8 CATHODE Figure 26. tPLH, tPHL, tf, tr, test circuit 14 0.1F VOUT 20 5nF 0.1F +_ 30V 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE RF=2.1k VFAULT VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 VOUT 11 VCLAMP 10 VEE 9 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 VIN 0.1F CF 5V +_ 7 ANODE 8 CATHODE 10mA VOUT 20 0.1F +_ 30V 5nF Figure 27. tDESAT fault test circuit 5V RF=2.1k SCOPE CF=15pF or 1nF 0.1F 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 30V 20 0.1F 360 VCM Figure 28. CMR Test circuit LED2 off 5V RF=2.1k SCOPE CF=15pF or 1nF 0.1F 5nF 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 30V 20 0.1F 360 VCM Figure 29. CMR Test Circuit LED2 on 15 5nF 5V RF=2.1k CF=15pF or 1nF 0.1F 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 VOUT 11 30V SCOPE 20 0.1F 360 Figure 30. CMR Test circuit LED1 off 5V 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE RF=2.1k CF=15pF or 1nF 0.1F 5nF VCM 30V SCOPE 20 0.1F 360 7 ANODE 8 CATHODE VCLAMP 10 VEE 9 5V 180 5 CATHODE 6 ANODE 7 ANODE 8 CATHODE 180 5nF Split resistors network with a ratio of 1:1 Figure 31. CMR Test Circuit LED1 on 16 VCM Application Information Product Overview Description The ACPL-330J is a highly integrated power control device that incorporates all the necessary components for a complete, isolated IGBT / MOSFET gate drive circuit with fault protection and feedback into one SO-16 package. Active Miller clamp function eliminates the need of negative gate drive in most application and allows the use of simple bootstrap supply for high side driver. An optically isolated power output stage drives IGBTs with power ratings of up to 100 A and 1200 V. A high speed internal optical link minimizes the propagation delays between the microcontroller and the IGBT while allowing the two systems to operate at very large common mode voltage differences that are common in industrial motor drives and other power switching applications. An output IC provides local protection for the IGBT to prevent damage during over current, and a second optical link provides a fully isolated fault status feedback signal for the microcontroller. A built in "watchdog" circuit, UVLO monitors the power stage supply voltage to prevent IGBT caused by insufficient gate drive voltages. This integrated IGBT gate driver is designed to increase the performance and reliability of a motor drive without the cost, size, and complexity of a discrete design. Two light emitting diodes and two integrated circuits housed in the same SO-16 package provide the input control circuitry, the output power stage, and two optical channels. The output Detector IC is designed manufactured on a high voltage BiCMOS/Power DMOS process. The forward optical signal path, as indicated by LED1, transmits the gate control signal. The return optical signal path, as indicated by LED2, transmits the fault status feedback signal. Under normal operation, the LED1 directly controls the IGBT gate through the isolated output detector IC, and LED2 remains off. When an IGBT fault is detected, the output detector IC immediately begins a "soft" shutdown sequence, reducing the IGBT current to zero in a controlled manner to avoid potential IGBT damage from inductive over voltages. Simultaneously, this fault status is transmitted back to the input via LED2, where the fault latch disables the gate control input and the active low fault output alerts the microcontroller. During power-up, the Under Voltage Lockout (UVLO) feature prevents the application of insufficient gate voltage to the IGBT, by forcing the ACPL-330J's output low. Once the output is in the high state, the DESAT (VCE) detection feature of the ACPL-330J provides IGBT protection. Thus, UVLO and DESAT work in conjunction to provide constant IGBT protection. 17 13 V CC2 UVLO ANODE CATHODE 6, 7 D R I V E R 5, 8 LED1 11 14 V OUT DESAT DESAT 9, 12 SHIELD V EE V CLAMP V CC1 FAULT VS 2 10 LED2 3 16 1, 4 15 SHIELD V CLAMP VE V LED Figure 32. Block Diagram of ACPL-330J Recommended Application Circuit The ACPL-330J has an LED input gate control, and an open collector fault output suitable for wired `OR' applications. The recommended application circuit shown in Figure 33 illustrates a typical gate drive implementation using the ACPL-330J. The following describes about driving IGBT. However, it is also applicable to MOSFET. Depending upon the MOSFET or IGBT gate threshold requirements, designers may want to adjust the VCC supply voltage (Recommended VCC = 17.5V for IGBT and 12.5V for MOSFET). The two supply bypass capacitors (0.1 F) provide the large transient currents necessary during a switching transition. Because of the transient nature of the charging currents, a low current (5mA) power supply suffices. The desaturation diode DDESAT 600V/1200V fast recovery type, trr below 75ns (e.g. ERA34-10) and capacitor CBLANK are necessary external components for the fault detection circuitry. The gate resistor RG serves to limit gate charge current and controls the IGBT collector voltage rise and fall times. The open collector fault output has a passive pull-up resistor RF (2.1 kW) and a 1000 pF filtering capacitor, CF. A 47 kW pull down resistor RPULL-DOWN on VOUT provides a predictable high level output voltage (VOH). In this application, the IGBT gate driver will shut down when a fault is detected and fault reset by next cycle of IGBT turn on. Application notes are mentioned at the end of this datasheet. + _ 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VE 16 VLED 15 RF 0.1F 0.1F DESAT 14 CF CBLANK 100 DDESAT RG + _ VCC2 13 VEE 12 Q1 R + _ VEE + VCE - RPULL--DOWN 9 Q2 + VCE - + HVDC 3-PHASE AC - HVDC Figure 33. Recommended application circuit (Single Supply) with desaturation detection and active Miller Clamp Description of Operation Normal Operation During normal operation, VOUT of the ACPL-330J is controlled by input LED current IF (pins 5, 6, 7 and 8), with the IGBT collector-to-emitter voltage being monitored through DESAT. The FAULT output is high. See Figure 34. Figure 34. Fault Timing diagramactivated is an internal feedback channel which brings the FAULT output low for the purpose of notifying the micro-controller of the fault condition. Fault Condition Fault Reset The DESAT pin monitors the IGBT Vce voltage. When the voltage on the DESAT pin exceeds 6.5 V while the IGBT is on, VOUT is slowly brought low in order to "softly" turn-off the IGBT and prevent large di/dt induced voltages. Also Once fault is detected, the output will be soft-shut down to low. All input LED signals will be ignored during the fault period to allow the driver to completely soft shut-down the IGBT. For ACPL-330J, the driver will automatically reset the FAULT pin after a fixed mute time of 25ms (typical). See Figure 34. t DESAT(LOW) IF 6.5V Automatic Reset after mute time V DESAT t BLANK t DESAT(10%) 90% VOUT 10% t DESAT(90%) FAULT 50% t DESAT(FAULT) t DESAT(MUTE) Figure 34. Fault Timing diagram 18 50% Output Control Slow IGBT Gate Discharge during Fault Condition The outputs (VOUT and FAULT) of the ACPL-330J are controlled by the combination of IF, UVLO and a detected IGBT Desat condition. Once UVLO is not active (VCC2 VE > VUVLO), VOUT is allowed to go high, and the DESAT (pin 14) detection feature of the ACPL-330J will be the primary source of IGBT protection. Once VCC2 is increased from 0V to above VUVLO+, DESAT will remain functional until VCC2 is decreased below VUVLO-. Thus, the DESAT detection and UVLO features of the ACPL-330J work in conjunction to ensure constant IGBT protection. When a desaturation fault is detected, a weak pull-down device in the ACPL-330J output drive stage will turn on to `softly' turn off the IGBT. This device slowly discharges the IGBT gate to prevent fast changes in drain current that could cause damaging voltage spikes due to lead and wire inductance. During the slow turn off, the large output pull-down device remains off until the output voltage falls below VEE + 2 Volts, at which time the large pull down device clamps the IGBT gate to VEE. Desaturation Detection and High Current Protection The ACPL-330J satisfies these criteria by combining a high speed, high output current driver, high voltage optical isolation between the input and output, local IGBT desaturation detection and shut down, and an optically isolated fault status feedback signal into a single 16-pin surface mount package. The fault detection method, which is adopted in the ACPL-330J is to monitor the saturation (collector) voltage of the IGBT and to trigger a local fault shutdown sequence if the collector voltage exceeds a predetermined threshold. A small gate discharge device slowly reduces the high short circuit IGBT current to prevent damaging voltage spikes. Before the dissipated energy can reach destructive levels, the IGBT is shut off. During the off state of the IGBT, the fault detect circuitry is simply disabled to prevent false `fault' signals. The alternative protection scheme of measuring IGBT current to prevent desaturation is effective if the short circuit capability of the power device is known, but this method will fail if the gate drive voltage decreases enough to only partially turn on the IGBT. By directly measuring the collector voltage, the ACPL-330J limits the power dissipation in the IGBT even with insufficient gate drive voltage. Another more subtle advantage of the desaturation detection method is that power dissipation in the IGBT is monitored, while the current sense method relies on a preset current threshold to predict the safe limit of operation. Therefore, an overly conservative over current threshold is not needed to protect the IGBT. DESAT Fault Detection Blanking Time The DESAT fault detection circuitry must remain disabled for a short time period following the turn-on of the IGBT to allow the collector voltage to fall below the DESAT threshold. This time period, called the DESAT blanking time is controlled by the internal DESAT charge current, the DESAT voltage threshold, and the external DESAT capacitor. The nominal blanking time is calculated in terms of external capacitance (CBLANK), FAULT threshold voltage (VDESAT ), and DESAT charge current (ICHG) as tBLANK = CBLANK x VDESAT / ICHG. The nominal blanking time with the recommended 100pF capacitor is 100pF * 6.5 V / 240 A = 2.7 sec. The capacitance value can be scaled slightly to adjust the blanking time, though a value smaller than 100 pF is not recommended. This nominal blanking time represents the longest time it will take for the ACPL-330J to respond to a DESAT fault condition. If the IGBT is turned on while the collector and emitter are shorted to the supply rails (switching into a short), the soft shut-down sequence will begin after approximately 3 sec. If the IGBT collector and emitter are shorted to the supply rails after the IGBT is already on, the response time will be much quicker due to the parasitic parallel capacitance of the DESAT diode. The recommended 100pF capacitor should provide adequate blanking as well as fault response times for most applications. IF UVLO(VCC2-VE) DESAT Function Pin 3 (FAULT) Output VOUT ON Active Not Active High Low ON Not Active Active (with DESAT fault) Low (FAULT) Low ON Not Active Active (no DESAT fault) High (or no fault) High OFF Active Not Active High Low OFF Not Active Not Active High Low 19 Under Voltage Lockout The ACPL-330J Under Voltage Lockout (UVLO) feature is designed to prevent the application of insufficient gate voltage to the IGBT by forcing the ACPL-330J output low during power-up. IGBTs typically require gate voltages of 15 V to achieve their rated VCE(ON) voltage. At gate voltages below 13 V typically, the VCE(ON) voltage increases dramatically, especially at higher currents. At very low gate voltages (below 10 V), the IGBT may operate in the linear region and quickly overheat. The UVLO function causes the output to be clamped whenever insufficient operating supply (VCC2) is applied. Once VCC2 exceeds VUVLO+ (the positive-going UVLO threshold), the UVLO clamp is released to allow the device output to turn on in response to input signals. As VCC2 is increased from 0 V (at some level below VUVLO+), first the DESAT protection circuitry becomes active. As VCC2 is further increased (above VUVLO+), the UVLO clamp is released. Before the time the UVLO clamp is released, the DESAT protection is already active. Therefore, the UVLO and DESAT Fault detection feature work together to provide seamless protection regardless of supply voltage (VCC2). Active Miller Clamp A Miller clamp allows the control of the Miller current during a high dV/dt situation and can eliminate the use of a negative supply voltage in most of the applications. During turn-off, the gate voltage is monitored and the clamp output is activated when gate voltage goes below 2V (relative to VEE). The clamp voltage is VOL+2.5V typ for a Miller current up to 1100mA. The clamp is disabled when the LED input is triggered again. Other Recommended Components The application circuit in Figure 33 includes an output pull-down resistor, a DESAT pin protection resistor, a FAULT pin capacitor, and a FAULT pin pullup resistor and Active Miller Clamp connection. Output Pull-Down Resistor During the output high transition, the output voltage rapidly rises to within 3 diode drops of VCC2. If the output current then drops to zero due to a capacitive load, the output voltage will slowly rise from roughly VCC2-3(VBE) to VCC2 within a period of several microseconds. To limit the output voltage to VCC2-3(VBE), a pull-down resistor, RPULL-DOWN between the output and VEE is recommended to sink a static current of several 650 A while the output is high. Pull-down resistor values are dependent on the amount of positive supply and can be adjusted according to the formula, Rpull-down = [VCC2-3 * (VBE)] / 650 A. 20 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 VCC RG RPULL-DOWN Figure 35. Output pull-down resistor. DESAT Pin Protection Resistor The freewheeling of flyback diodes connected across the IGBTs can have large instantaneous forward voltage transients which greatly exceed the nominal forward voltage of the diode. This may result in a large negative voltage spike on the DESAT pin which will draw substantial current out of the driver if protection is not used. To limit this current to levels that will not damage the driver IC, a 100 ohm resistor should be inserted in series with the DESAT diode. The added resistance will not alter the DESAT threshold or the DESAT blanking time. 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE 6 VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 Figure 36. DESAT pin protection. 100pF 100 VCC RG DDESAT Capacitor on FAULT Pin for High CMR Pull-up Resistor on FAULT Pin Rapid common mode transients can affect the fault pin voltage while the fault output is in the high state. A 1000 pF capacitor should be connected between the fault pin and ground to achieve adequate CMOS noise margins at the specified CMR value of 50 kV/s. The FAULT pin is an open collector output and therefore requires a pull-up resistor to provide a high-level signal. Also the FAULT output can be wire `OR'ed together with other types of protection (e.g. over-temperature, overvoltage, over-current ) to alert the microcontroller. Other Possible Application Circuit (Output Stage) 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 01F 01F 01F O 6 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 R O R 2 RG 1 +_ Q1 RPULL-DOWN _+ Q2 + VCE + VCE - + HVDC 3-PHASE AC - HVDC Figure 37. IGBT drive with negative gate drive, external booster and desaturation detection (VCLAMP should be connected to VEE when it is not used) VCLAMP is used as secondary gate discharge path. * indicates component required for negative gate drive topology 1 VS 2 VCC1 3 FAULT 4 VS 5 CATHODE VE 16 VLED 15 DESAT 14 VCC2 13 VEE 12 01F 01F 01F O 6 ANODE VOUT 11 7 ANODE VCLAMP 10 8 CATHODE VEE 9 R O R 2 RG 1 +_ Q1 RPULL-DOWN +_ Q2 + VCE + VCE - R3 Figure 38. Large IGBT drive with negative gate drive, external booster. VCLAMP control secondary discharge path for higher power application. 21 + HVDC 3-PHASE AC - HVDC Thermal Model The ACPL-330J is designed to dissipate the majority of the heat through pins 1, 4, 5 & 8 for the input IC and pins 9 & 12 for the output IC. (There are two VEE pins on the output side, pins 9 and 12, for this purpose.) Heat flow through other pins or through the package directly into ambient are considered negligible and not modeled here. In order to achieve the power dissipation specified in the absolute maximum specification, it is imperative that pins 5, 9, and 12 have ground planes connected to them. As long as the maximum power specification is not exceeded, the only other limitation to the amount of power one can dissipate is the absolute maximum junction temperature specification of 125C. The junction temperatures can be calculated with the following equations: Tji = Pi (i5 + 5A) + TA Tjo = Po (o9,12 + 9,12A) + TA Tjo Tji l9, 12 = 30C/W I1 = 60C/W TP9, 12 TP1 1A = 50C/W* 9, 12A = 50C/W* TA where Pi = power into input IC and Po = power into output IC. Since 5A and 9,12A are dependent on PCB layout and airflow, their exact number may not be available. Therefore, a more accurate method of calculating the junction temperature is with the following equations: Tji = Pi i5 + TP5 Tjo = Po o9,12 + TP9,12 These equations, however, require that the pin 5 and pins 9, 12 temperatures be measured with a thermal couple on the pin at the ACPL-330J package edge. If the calculated junction temperatures for the thermal model in Figure 39 is higher than 125C, the pin temperature for pins 9 and 12 should be measured (at the package edge) under worst case operating environment for a more accurate estimate of the junction temperatures. Tji = junction temperature of input side IC Tjo = junction temperature of output side IC TP5 = pin 5 temperature at package edge TP9,12 = pin 9 and 12 temperature at package edge I5 = input side IC to pin 5 thermal resistance o9,12 = output side IC to pin 9 and 12 thermal resistance 5A = pin 5 to ambient thermal resistance 9,12A = pin 9 and 12 to ambient thermal resistance *The 5A and 9,12A values shown here are for PCB layouts with reasonable air flow. This value may increase or decrease by a factor of 2 depending on PCB layout and/or airflow. Figure 39. ACPL-330J Thermal Model Related Application Notes AN5314 - Active Miller Clamp AN5315 - "Soft" Turn-off Feature AN1043 - Common-Mode Noise : Sources and Solutions AV02-0310EN - Plastic Optocouplers Product ESD and Moisture Sensitivity For product information and a complete list of distributors, please go to our web site: www.avagotech.com Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries. Data subject to change. Copyright (c) 2005-2015 Avago Technologies. All rights reserved. AV02-1280EN - November 20, 2015