Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled For more Information please call 1-800-Belden1 General Description: Fire Alarm Cable, Plenum-FPLP, 2-18 AWG solid bare copper conductors with Flamarrest(R) insulation, Flamarrest(R)jacket with ripcord Usage (Overall) Suitable Applications: Fire Protection, Alarm, Signal, Monitor/Detection, Audio Circuits, Control Circuits, Initiating Circuits, Notification Circuits Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 2 18 Solid BC - Bare Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Trade Name Insulation Material Flamarrest(R) Wall Thickness (mm) LS PVC - Low Smoke Polyvinyl Chloride 0.203 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest(R) Nom. Wall Thickness (mm) LS PVC - Low Smoke Polyvinyl Chloride 0.381 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm) Twists (twist/m) 69.849725 14.4364 Overall Cabling Color Code Chart: Number Color 1 Black 2 Red Overall Nominal Diameter: 3.658 mm Mechanical Characteristics (Overall) Operating Temperature Range: 0C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 23.811 Kg/Km Max. Recommended Pulling Tension: 174.369 N Min. Bend Radius/Minor Axis: 38.100 mm Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled Min. Bend Radius/Minor Axis: 38.100 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: FPLP NEC Articles: 760 EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Other Specification: California State Fire Marshall Flame Test UL Flame Test: NFPA 262 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 5320UL Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.492 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 101.711 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 20.9984 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 5 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 6320UL D15C500 152 MT 3.402 KG BLUE 2 #18 FLRST FLRST 6320UL 002U1000 305 MT 7.711 KG RED 2 #18 FLRST FLRST 6320UL 002U500 152 MT 4.082 KG RED 6320UL 0021000 305 MT 7.711 KG RED 6320UL 003U1000 305 MT 7.711 KG ORANGE 2 #18 FLRST FLRST 6320UL 0031000 305 MT 7.711 KG ORANGE 2 #18 FLRST FLRST 6320UL 004U1000 305 MT 7.711 KG YELLOW 2 #18 FLRST FLRST 6320UL 005U1000 305 MT 7.711 KG GREEN, DARK 2 #18 FLRST FLRST 6320UL 0051000 305 MT 7.711 KG GREEN, DARK 2 #18 FLRST FLRST Page 2 of 3 Notes Item Desc 2 #18 FLRST FLRST C 2 #18 FLRST FLRST 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6320UL Multi-Conductor - Commercial Applications - 2 Conductors Cabled 6320UL 007C500 152 MT 3.402 KG VIOLET 2 #18 FLRST FLRST 6320UL 007U1000 305 MT 7.711 KG VIOLET 2 #18 FLRST FLRST 6320UL 009C500 152 MT 3.402 KG WHITE 2 #18 FLRST FLRST 6320UL 009U1000 305 MT 7.711 KG WHITE 2 #18 FLRST FLRST 6320UL 010C500 152 MT 3.402 KG BLACK 2 #18 FLRST FLRST 6320UL 010U1000 305 MT 7.711 KG BLACK 2 #18 FLRST FLRST 6320UL 0101000 305 MT 7.711 KG BLACK 2 #18 FLRST FLRST 6320UL 012U1000 305 MT 7.711 KG PINK 2 #18 FLRST FLRST Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 03-13-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013