TEST AND REQUIREMENTS
Essentially all tests are carried out in
accordance with the schedule of
“IEC publication 60115-8”, category
LCT/UCT/56 (rated temperature
range: Lower Category
Temperature, Upper Category
Temperature; damp heat, long term,
56 days). The testing also covers the
requirements specified by EIA and
EIAJ.
The tests are carried out in
accordance with IEC publication
60068, “Recommended basic
climatic and mechanical robustness
testing procedure for electronic
components” and under standard
atmospheric conditions according to
“IEC 60068-1”, subclause 5.3.
Unless otherwise specified the
following values apply:
Temperature: 15 °C to 35 °C
Relative humidity: 25% to 75%
Air pressure: 86 kPa to 106 kPa
(860 mbar to 1060 mbar).
Table 4 Test procedures and requirements
IEC
60115-8
CLAUSE
IEC
60068-2
TEST
METHOD
TEST PROCEDURE REQUIREMENTS
Tests in accordance with the schedule of IEC publication 60115-8
4.4.1 visual
examination no holes; clean surface;
no damage
applied voltage (+0/−10%); R − Rnom: max. ±5%
R < 10 Ω: 0.1 V
10 Ω ≤ R < 100 Ω: 0.3 V
100 Ω ≤ R < 1 kΩ: 1 V
1 kΩ ≤ R < 10 kΩ: 3 V
10 kΩ ≤ R < 100 kΩ: 10 V
4.5 resistance
100 kΩ ≤ R < 100 MΩ: 25 V
4.18 20 (Tb) resistance to
soldering heat unmounted chips: 10 ±1 s; 260 ±5 °C no visible damage
∆R/R max.: ±(2% + 0.1 Ω)
4.29 45 (Xa) component
solvent
resistance
isopropyl alcohol or H2O
followed by brushing
in accordance with “MIL 202 F”
no visible damage
4.17 20 (Ta) solderability unmounted chips completely immersed
for 2 ±0.5 s in a solder bath at
235 ±2 °C
good tinning
(≥95% covered); no visible
damage
4.7 voltage proof
on insulation maximum voltage (RMS) during
1 minute metal block method no breakdown or flashover
4.13 short time
overload room temperature; P = 6.25 × Pn;
5 s (V ≤ 2 × Vmax) ∆R/R max.: ±(3% + 0.1 Ω)
In Table 4 the tests and
requirements are listed with
reference to the relevant clauses of
“IEC publications 60115-8 and
60068”; a short description of the
test procedure is also given. In some
instances deviations from the IEC
recommendations were necessary
for our method of specifying.
All soldering tests are performed
with mildly activat ed flux.