DIN 1.0 / 2.3 (50Ω) Connectors 114-90009
2 of 2 Rev. A3
3. INSTRUCTIONS
3.1 Prepare cable
- Prepare the cable according to the dimension table.
- It’s recommended not to remove the foil; if that causes problems with high voltage performance you can
remove the foil up to the braid but leave the foil beneath the braid.
- Slide crimp ferrule over
3.1.1 Dimension table (recommended dimensions)
DIMENSION “a” “b” “c”
3.1.1.1 10.7±0.2 3.6±0.2 6
±0.2
3.1.1.2 12.7±0.2 3.2±0.2 8.5±0.2
3.1.1.3 10.4±0.2 3.55±0.2 5.4±0.2
3.1.1.4 10.0±0.2 2.8±0.2 5.8±0.2
3.1.1.5 3±0.1 2
±0.1 0
3.2 Crimp on center conductor
- For Cable LMR-240 FR push the center conductor until the spring inside the positioner is depressed.
- For Cable WP 93385 L2, slide the Dielectric disk (1460460-1) on the cable center conductor against the
cable dielectric.
- Slide center contact over cable center conductor.
- Make sure that the center conductor butts on the dielectric disk.
- Crimp center conductor as close as possible to the dielectric disk; using the appropriate crimp dies
mentioned in the data table section 2 page 1.
3.3 Contact assembly
- Flare braid and insert contact into the crimp of the body. The contact must bottom on the internal
dielectric of the connector.
- Slide the crimp ferrule over the braid until it bottoms against the body. Crimp the ferrule using the
appropriate crimp dies mentioned in the data table section 2 page 1.