PERFORMANCE DATE
Type
Historical Part Number - ZC0204
Climatic Category 55/155/56
Short Time Overload
IEC60115-1 clause 4.13
(U=2,5* , ≤2* Umax, 5 [s])
Standard
operation ±[%]
0,15(>211kΩ) 0,03 (≤1M) ; 0,15 (>1M) 0,03 (≤1M) ; 0,15 (>1M)
Power
operation - 0,05 (≤1M) ; 0,15 (>1M) 0,05 (≤1M) ; 0,15 (>1M)
Single pulse high voltage overload
IEC60115-1 clause 4.27
(U=10* ,Severity 4, 10 pulses 10[µs]/700[µs]
Standard
operation ±[%] - 0,15 0,25
Power
operation - 0,15 0,5
Periodic electric overload
IEC60115-1 clause 4.39
(U=15* ,0.1[s]on, 2.5[s]off,1000 cycles
Standard
operation ±[%] - 0,15 0,15
Power
operation - 0,3 0,3
Failure Rate (Total, max, 60[%] cont. lev.) [10
h
] ≤ 0,1
Endurance at 70ºC,
IEC60115-1 clause 4.25.1
(U= Umax,, 1,5[h]ON ; 0,5[h]OFF)
Precision
operation ±[%]
Standard
operation ±[%]
Power
operation ±[%]
Endurance at upper Category Temp.
IEC60115-1 clause 4.25.3
( 1000[h]
±[%]
125ºC 0,25 (<211kΩ) ; 1 (>211kΩ) 0,15 (≤1M) ; 0,5 (>1M)
(>1M)
155ºC - 0,3 (≤1M) ; 1 (>1M)
(>1M)
Damp Heat, Steady State
IEC60115-1 clause 4.24
(40±2[°C], 93±3[% r.h.], 56[d])
±[%] 0,5 (<211kΩ) ; 1 (>211kΩ) 0,25 (≤ 1M) ; 1 (>1M) 0,25 (≤ 1M) ; 1 (>1M)
Damp Heat, Steady State, Accelerated
IEC60115-1 clause 4.37
(85±2[°C], 85±5[%RH], U = 0.3* )
±[%] - 0,25 (≤ 1M) ; 2 (>1M) 0,5 (≤ 1M) ; 2 (>1M)
Temperature Cycling
IEC60068-2-14 ; IEC60115-1 clause 4.19
( 30[min] each , 1000 cycles)
±[%]
-55~155ºC
- 0,5 0,5
Vibration
IEC60068-2-6 ; IEC60115-1 clause 4.22
(10;2000[Hz], ≤1,5[mm] , or ≤200[m/s2] 7,5[h])
±[%] - 0,05 (≤ 1M) ; 0,1 (>1M) 0,05
Resistance to Soldering Heat
IEC60115-1 clause 4.18
(260±5[°C], 10±1[s])Solder bath method
±[%] 0,1 (<211kΩ) ;
0,25(>211kΩ) 0,1 (≤ 10R) ; 0,05 (>10R) 0,1 (≤ 10R) ; 0,05 (>10R)
Electrostatic Discharge
IEC60115-1 clause 4.38 ; IEC61340-3-1
( 3 positives + 3 negatives discharges)
±[%] - 0,5 [2 kV] 0,5 [4 kV]
Voltage proof
IEC60115-1 clause 4.7 URMS=UINS, 60 [s] - No flash over or breakdown
Flammability
IEC60115-1 clause 4.35, IEC60695-11-5
Needle flame test, 10[s]
-
Solderability
IEC60068-2-20 ; IEC60115-1 clause 4.17
(235±3[ºC] 2±0,2[s],SnAg
Cu
or SnAg
)
- ≥ 95% covered, no visible damage
Component Resistance to Solvents
IEC60068-2-45 ; IEC60115-1 clause 4.29
(50[ºC] method 2)
No visible damage
Resistance to solvents of Marking
IEC60068-2-45 ; IEC60115-1 clause 4.30
(50[ºC] method 1) Marking visible , no visible damage
Marking
IEC60062
Color code
NOTES: MARKING [COLOR CODE]:
•
ZCM204 Color code marking is applied according to IEC 60062 in four bands (E24 series) for 5 % tolerance, or in five bands (E96 or E192 series).
Each color band appears as a single solid
line, voids are permissible if at least 2/3 of the band is visible from each radial angle of view. The
last color band for tolerance is approximately 50 % wider than the other bands.
•
ZCM207 Color code marking is applied according to IEC 60062 in four (E24 series) or six bands (E96 series). Each color band appears as a single
solid line, voids are permissible if at least
2/3 of the band is visible from each radial angle of view. The last color band represents the TCR for
resistors with TCR 50 ppm/K and nominal tolerance 1 %.
Zero ohm jumpers are marked with one centered black band.