Low Voltage Outputs
High Power Density
Efficiency 89% on 3.3 volt
Telecom Approval & Compliance
Wide Operating Temperature
International Safety Approvals
Meets Tight 0.6”
Board Pitch Requirements
Specification
Input
Input Voltage 36-76 VDC
Input Current 0.8 A - 2.37 A typical for ILQ100
0.39 A - 1.18 A typical for ILQ50
Remote On/Off Negative Logic standard
Positive Logic available
Input Reverse Voltage External components required
Protection
Output
Output Voltage 1.2-5 VDC
Output Voltage -20%, +10% (1.2V, 1.8 V,
Adjustment 2.5 V), ±15% (3.3 V, 5 V)
Line Regulation ±0.5% max
Load Regulation ±1.0% max
Output Voltage ±1%
Accuracy
Ripple & Noise 100 mV max
Transient Response 5% deviation 100 µs recovery
time for a 50% load step
Temperature 0.02%/°C
Coefficient
Remote Sensing Standard
Overvoltage 120% - 140% auto restart
Protection
Overcurrent 105% - 140% for ILQ100 auto restart
Protection 105% - 150% for ILQ50 auto restart
Short Circuit Protected to short circuit conditions
Protection
Over Temperature Shutdown in overtemp condition
Protection
General
Efficiency 89% at 3.3 V (ILQ100)
Isolation Voltage 1500 VDC Input to Output
1500 VDC Input to Baseplate
500 VDC Output to Baseplate
Package Style Open frame, baseplate option
for ILQ100
Weight 50g Open frame
75g (baseplate 100 W)
Environmental
Operating -40°C to +85°C Ambient;
Temperature 100°C with baseplate
with 200LFM air ILQ100: full power to 50°C
ILQ50: full power to 75°C
see derating charts
Cooling Convection or Forced Air
Humidity 5-95% RH non condensing
Storage Temperature -40°C to +100°C
Shock 196.1 m/s2
Vibration 10-55 Hz (1 min) amplitude
0.825 mm constant X,Y, Z axis
1 hour each.
Safety
Safety Approvals UL1950, EN60950, CSA950
CE Marked for LVD
EMI/EMC FCC level B Part 15 with
external filtering
Warranty 1 Year
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
DC/DC Quar ter Bricks/High Efficiency
Up To 25 Amps
ILQ50/100 Series
Intelligent Design Quality Product
XPiQ inc.
ILQ 50-100 2/11/01 1:56 pm Page 1
OUTPUT VOLTAGE & CURRENT RATINGS
Power (Watts) Voltage Maximum Current Efficiency Model 48 V Input
Single Output
14.4 W 1.2 V 12.0 A 78% ILQ50-312AL
21.6 W 1.8 V 12.0 A 83% ILQ50-318AL
30.0 W 2.5 V 12.0 A 85% ILQ50-325AL
39.6 W 3.3 V 12.0 A 88% ILQ50-300AL
50.0 W 5.0 V 10.0 A 90% ILQ50-301AL
30.0 W 1.2 V 25.0 A 80% ILQ100-312AL
45.0 W 1.8 V 25.0 A 84% ILQ100-318AL
62.5 W 2.5 V 25.0 A 86% ILQ100-325AL
82.5 W 3.3 V 25.0 A 89% ILQ100-300AL
100.0 W 5.0 V 20.0 A 90% ILQ100-301AL
Mechanical Details
Pin# Label Function
1 -Vin Negative Input Terminal
2 CNT ON/OFF Control Terminal
3 +Vin Positive Input Terminal
4 -V Negative Output Terminal
5 -S Negative Remote Sensing
6 TRIM Output Voltage Adjustment Terminal
7 +S Positive Remote Sensing
8 +V Positive Output Terminal
Pin Out
Open Frame Models
ILQ50 or ILQ100
“AL” or “AH” suffix
Baseplate Models
Available on ILQ100 only
“BL” or “BH” suffix
Open Frame ILQ50-300AL unit used as a standard curve. Open Frame ILQ100-300AL unit used as a standard curve.
1. For Positive On/Off logic, replace suffix “L” with suffix “H”.
2. For ILQ 100 Series only - change AL suffix to BL suffix for baseplate version.
Notes
ILQ50 ILQ100
Derating Cur ves
OUTPUT VOLTAGE & CURRENT RATINGS ILQ 50-100
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
ILQ 50-100 2/11/01 1:56 pm Page 2