Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5504UE Multi-Conductor - Commercial Applications For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Riser-CMR, 6-22 AWG stranded bare copper conductors with polyolefin insulation, PVC jacket with ripcord Usage (Overall) Suitable Applications: Security Systems, Intercom/PA Systems, Sound/Audio Systems, Power Limited Controls, and Single Line Telephone. Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 6 22 7x30 BC - Bare Copper Total Number of Conductors: 6 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PP - Polypropylene 0.203 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.432 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Lay Length & Direction: Length (mm) Direction Twists (twist/m) 63.500 Left Hand 15.749 Overall Cabling Color Code Chart: Number Color 1 Black 2 Red 3 White 4 Green 5 Brown 6 Blue Overall Nominal Diameter: 4.267 mm Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 75C Page 1 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5504UE Multi-Conductor - Commercial Applications Bulk Cable Weight: 28.276 Kg/Km Max. Recommended Pulling Tension: 242.872 N Min. Bend Radius/Minor Axis: 41.275 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR NEC Articles: 800 CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1666 Vertical Shaft C(UL) Flame Test: FT4 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 6504UE Surface Printing (Overall) Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 55.777 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 53.1522 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Description Current 10C Temperature Rise 2 Amps per conductor @ 25C ambient Put Ups and Colors: Item # Putup Ship Weight Color 5504UE 008U1000 305 MT 9.072 KG GRAY 5504UE 0081000 305 MT 9.072 KG GRAY 5504UE 008500 152 MT 4.536 KG GRAY Page 2 of 3 Notes Item Desc 6 #22 PP FRPVC C 6 #22 PP FRPVC 6 #22 PP FRPVC 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5504UE Multi-Conductor - Commercial Applications 5504UE 009C500 152 MT 4.309 KG WHITE 6 #22 PP FRPVC 5504UE 009U1000 305 MT 9.072 KG WHITE 6 #22 PP FRPVC 5504UE 009U500 152 MT 4.763 KG WHITE 6 #22 PP FRPVC Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 08-20-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 08-21-2013