2Specifications are subject to change without notice (27.12.99)
EBF
General Specifications
EMC Electromagnetic
Compatibility
Immunity Acc. to IEC 60801-4
Acc. to IEC 60801-5
Power ON delay ≤200 ms
Indication for
Power supply ON LED, green
Environment
Degree of protection IP 20
Pollution degree 3
Operating temperature -20° to +50°C (-4° to +122°F)
Storage temperature -50° to +85°C (-58° to +185°F)
Weight 125 g
Screw terminals
Tightening torque Max. 0.5 Nm acc. to IEC 60947
Approvals UL, CSA
CE-marking Yes
Supply Specifications
Power supply
Overvoltage cat. III (IEC 60664)
Rated operational voltage (IEC 60038)
through term. A1 & A2 C24 24 VAC/DC, -10/+15%
230 115-230 VAC, -10/+15%
Frequency 50/60 Hz, -5/+5 Hz
Voltage interruption ≤40 ms
Dielectric voltage None
Rated impulse withstand
voltage 4 kV (1.2/50 µs)
Rated operational current
C24 60 mA (may be up to
300 mA for 10 s)
230 20 mA (may be up to
500 mA for 1 s)
Wiring DiagramMode of Operation
Operation Diagram
Knob-adjustable on absolute
scale.
The relay operates immedi-
ately when power supply is
applied.
When power supply is inter-
rupted, the time period
starts, and at expiration of
the set
tim
e period the relay
releases.
If power supply is reapplied
before the relay has
released, the time is reset
and the relay remains ON.
For safe charging of the
built-in capacitor, the power
supply must be applied for
min. 20 s or 1 time period +
1 s (whichever is less).
For safe reset of the relay
(after time-out), the power
supply must be interrupted
for at least 60 s.
Time Setting