Title SPECIFICATION CONTROL DRAWING SCD 400R1121
TWO CONDUCTOR CABLE, SHIELDED, JACKETED, LIMITED FIRE HAZARD, 600 VOLT Date 3-8-16 Revision B
This specification sheet forms a part of the latest issue of Raychem Specification WCD 3114.
SHIELD - TIN COATED COPPER
COMPONENT WIRES - 400R0111 JACKET - RADIATION-CROSSLINKED,
FLUOROPOLYMER
TABLE I. CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
SHIELD
SIZE
(AWG)
JACKET THICKNESS
(inch) (mm) OUTSIDE DIAMETER
(inch) (mm) MAXIMUM
WEIGHT
(lbs/1000 ft.)
(kg/km)
MINIMUM NOMINAL NOMINAL MAXIMUM
400R1121-26-* 26 38 .006 (.152) .008 (.203) .101 (2.57) .106 (2.69) 8.3 (12.4)
400R1121-24-* 24 36 .006 (.152) .008 (.203) .117 (2.97) .123 (3.12) 11.5 (17.1)
400R1121-22-* 22 36 .006 (.152) .008 (.203) .131 (3.33) .138 (3.51) 14.7 (21.9)
400R1121-20-* 20 36 .006 (.152) .008 (.203) .147 (3.73) .154 (3.91) 18.9 (28.1)
400R1121-18-* 18 36 .007 (.178) .009 (.229) .169 (4.29) .177 (4.50) 25.7 (38.2)
400R1121-16-* 16 36 .007 (.178) .009 (.229) .183 (4.65) .192 (4.88) 30.4 (45.2)
400R1121-14-* 14 36 .007 (.178) .009 (.229) .217 (5.51) .228 (5.79) 42.5 (63.2)
400R1121-12-* 12 36 .007 (.178) .009 (.229) .255 (6.48) .268 (6.81) 59.8 (89.0)
400R1121-10-* 10 36 .008 (.203) .010 (.254) .299 (7.59) .314 (7.98) 86.3 (128.)
NOTE: Nominal values are for information only. Nominal values are not requirements.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN A CCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES
AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL B E OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2015-2016 Tyco Electronics Corporation. All rights reserved.
SPECIFICATION CONTROL DRAWING Page
2 of 2
Revision
B
SCD
400R1121
TABLE II. CABLE PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (mm) (± 3%) WEIGHT
(lb) (kg) (± 3%)
ACCELERATED
AGING COLD
BEND ACCELERATED
AGING COLD
BEND
400R1121-26-* 3.00 (76.2) 3.00 (76.2) .250 (.113) 1.50 (.680)
400R1121-24-* 3.00 (76.2) 3.00 (76.2) .375 (.170) 1.50 (.680)
400R1121-22-* 6.00 (152.) 6.00 (152.) .375 (.170) 3.00 (1.36)
400R1121-20-* 6.00 (152.) 6.00 (152.) .375 (.170) 3.00 (1.36)
400R1121-18-* 6.00 (152.) 6.00 (152.) .500 (.227) 3.00 (1.36)
400R1121-16-* 6.00 (152.) 6.00 (152.) .500 (.227) 3.00 (1.36)
400R1121-14-* 6.00 (152.) 6.00 (152.) 1.00 (.454) 9.00 (4.08)
400R1121-12-* 10.0 (254.) 10.0 (254.) 1.00 (.454) 9.00 (4.08)
400R1121-10-* 10.0 (254.) 10.0 (254.) 1.00 (.454) 9.00 (4.08)
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 125°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 6 hours
BLOCKING: 150 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute
FLAMMABILITY: Char Length, 5 ft. (1.5 m) (ma ximum)
JACKET COLOR: White preferred
JACKET CONCENTRICITY: 70% (minimum)
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 200% (minimum)
Tensile Strength, 4000 lbf/in2 (27.6 MPa) (minimum)
JACKET FLAWS:
Spark Test, 1.5 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
SMOKE RELEASE:
Peak Smoke Release Rate, 0.40 m2/s (maximum)
Total Smoke Release, 150 m2 (maximum)
SMOKE TEST: D4, 50 (maximum); Dm, 300 (maximum)
TOXICITY: HCN: 100 ppm (maximum) SO2: 100 ppm (maximum)
CO: 3500 ppm (maximum) HF: 100 ppm (maximum)
NO: 100 ppm (maximum) HCI: 500 ppm (maximum)
VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute
1/ PART NUMBER:
The "*" in the part numbers in Tables I and II shall be replaced by color code
designators with a slash separating the component wire colors and a dash
separating the component wire colors from the jacket color.
Example: AWG 20, black and brown component wires; white jacket:
400R1121-20-0/1-9
CABLE IDENTIFICATION:
Jacket shall be marked in contrasting color as follows:
"RAYCHEM 400R1121-xx - 600V Yr of Mfg" (xx = applicable AWG size)
1/ See footer section on page 1