MINIA TURE FUSES INIATURE 5x20mm / No. 201 DIN 41571, TT.2, .2, 250V 250V,, M Specifications Time-Current Characteristic Packaging Medium Time Lag (M) 000: Bulk (1000 pcs.) 002: Bulk (20x10 pcs.) 043: With mounted holder - Tape/Reel (1250 pcs.) on request Standard DIN 41571, T.2 Approvals Materials cURus Tube: End Caps: Optional Holders: Features Visual fault indication Direct solderable or plug-in versions Worldwide availability Glass Nickel-plated brass Nickel-plated caps Tin-plated copper wires Operating TTemperature emperature -25C to +70C (consider de-rating) Dimensions (mm) Climatic Category -25C/+70C/21 days (EN 60068-1..3) Stock Conditions +10C to +60C relative humidity 75% yearly average, without dew, maximum value for 30 days-95% Vibration Resistance 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60Hz at 0.75mm amplitude 60 - 2000Hz at 10g acceleration Solderability 260C, 3 sec. (Wave) 350C, 1 sec. (Hand) Optional Holders Soldering Heat Resistance 260C, 10 sec. (IEC 68-2-20) Marking , M, Current Rating, 250V, C Unit Weight Limits for Pre-arcing Time Rated Current 32mA ... 1.25A 1.5 x IN 2.1 x IN 4 x IN > 1h < 10 min 40ms ... 2s 1.1g (approx.) 2.1g (with leads) 10 x IN 5ms ... 90ms Permissible continuous operating current is 100 % at ambient temperature of 23C (73.4F). 100% Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IN 1.5 x IN 10 x IN max. (mV) max. (W) min. (A2s) 32mA 50mA 63mA 80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 500mA 630mA 800mA 1.00A 1.25A 0032 0050 0063 0080 0100 0125 0160 0200 0250 0315 0400 0500 0630 0800 1100 1125 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 80A / 250VAC 50-60Hz cos = 1.0 640 600 560 520 470 420 370 320 280 250 230 210 190 170 160 160 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.4 0.4 0.5 0.6 0.7 0.8 0.005 0.009 0.011 0.017 0.022 0.033 0.085 0.12 0.13 0.16 0.28 0.35 0.6 1.1 2.0 3.2 Approvals cURus * * * * * * * * * * * * * * * * Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 011906 Qty. OrderNumber Series 201 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. Specifications are subject to change without notice www.littelfuse.com MINIA TURE FUSES INIATURE 00 0,0 10 5x20mm / No. 201 I-t Characteristics ,00 10 (Min-Max Limit) DIN 41571, T.2 (32mA ... 1.25A) 0 0 1,0 0 10 10 Time (sec.) 0 1 0.1 1 0.0 01 0.0 1 1.5 2 3 4 5 6 7 8 9 10 15 I Fault / I Rated Contact Littelfuse for individual I-t curves 011906 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 5x20 mm mm/ No. 230 250V Specifications Time-Current Characteristic Very Quick Acting (FF) Packaging 000: Bulk (1.000 pcs.) 002: Pack (100 pcs.) Standard Materials None Tube: End Caps: Approvals None Ceramic Nickel-plated brass Operating TTemperature emperature -25 C to +70 C (consider de-rating) Climatic Category -25 C/+70 C/21 days (EN 60068-1..3) Stock Conditions Dimensions (mm) +10 C to +60 C relative humidity 75 % yearly average, without dew Vibration Resistance 5,2 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60 Hz at 0.75 mm amplitude 60 - 2000 Hz at 10 g acceleration 20 Marking , FF, Current Rating, 250V, E Limits for Pre-arcing Time Rated Current 1.0 x IN 1.5 x IN 1.60 A ... 10.00 A >1h < 30 min 2.75 x IN 4 x IN 10 x IN 2 ms ... 100 ms 1 ms ... 25 ms < 3 ms Permissible continuous operating current is 80 % at ambient temperature of 23 C (73.4 F). Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IN 1.5 x IN 10 x IN max. (mV) max. (W) max. (A2s) 1.60 A 2.00 A 2.50 A 3.15 A 4.00 A 5.00 A 1 6.30 A 1 8.00 A 1 10.00 A 1 1160 1200 1250 1315 1400 1500 1630 1800 2100 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 1000 A @ 250 V AC 50 Hz cos = 1.0 1000 600 500 480 480 500 480 400 400 0.12 0.35 0.44 0.75 1.60 2.50 5.00 10.00 20.00 Approvals None 1 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered. Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 012006 Qty. OrderNumber Series 230 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 00 0,0 10 5x20mm 5x20mm/ No. 230 Time-current characteristics (Min-Max Limits) 0 ,00 10 1,0 00 10 10 Time (sec.) 0 1 0.1 1 0.0 01 0.0 1 1.5 2 3 4 5 6 7 8 9 10 15 I Fault / I Rated Contact Littelfuse for individual I-t curves 012006 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 6.3x32 mm / No. 231 Leadfree Special TType, ype, 500 V V,, FF Specifications T ime-Current Packaging Characteristic 002: Pack (100 pcs.) Very Quick Acting (FF) Materials Standard Tube: End Caps: None Approvals Operating TTemperature emperature None -25 C to +70 C (consider de-rating) Features Designed for semiconductor protection For high voltage applications High breaking capacity Pluggable into clips or shocksafe holders Dimensions (mm) Ceramic Nickel-plated brass Climatic Category -25 C/+70 C/21 days (EN 60068-1..3) Stock Conditions +10 C to +60 C relative humidity 75 % yearly average, without dew, maximum value for 30 days-95 % Vibration Resistance 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60 Hz at 0.75 mm amplitude 60 - 2000 Hz at 10 g acceleration 6,3 32 Marking , FF, Current Rating, 500 V Unit Weight 2.5 g (approx.) Limits for Pre-arcing Time Rated Current 2.00 A ... 16.00 A 1.0 x IN 1 >1h 1.5 x IN 2.75 x IN < 30 min 4 x IN 10 x IN 2 ms ... 100 ms 1 ms ... 25 ms < 3 ms Permissible continuous operating current is 80 % at ambient temperature of 23C (73.4F). 80% Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IN 1.0 x IN 10 x IN max. (mV) max. (W) max. (A2s) 2.00 A 2.50 A 3.15 A 4.00 A 2 5.00 A 2 6.30 A 2 8.00 A 2 10.00 A 2 12.50 A 2 16.00 A 1,2 1200 1250 1315 1400 1500 1630 1800 2100 2125 2160 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V 1000A / 500VAC 50-60Hz cos = 1.0 800 800 800 700 600 600 600 500 500 480 3.0 3.0 3.0 3.6 3.6 3.6 5.2 5.2 6.3 6.3 0.35 0.44 0.75 1.6 2.5 5 10 20 38 68 Approvals None 1 16.00 A: 0.9 x I > 1 h N 2 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered. Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 012006 Qty. OrderNumber Series 231 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. Specifications are subject to change without notice www.littelfuse.com MINIA TURE FUSES INIATURE 00 0,0 10 6.3x32mm / No. 231 I-t Characteristics (Min-Max Limit) 0 ,00 10 1,0 00 10 10 Time (sec.) 0 1 0.1 1 0.0 01 0.0 1 1.5 2 3 4 5 6 7 8 9 10 15 I Fault / I Rated Contact Littelfuse for individual I-t curves 012006 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 5x25mm 5x25mm/ No. 240 Indicator Indicator,, 250V Specifications Time-Current Packaging Quick Acting (F) Characteristic 002: Pack (100 pcs.) Standard Materials None Tube: End Caps: Approvals None Ceramic Nickel-plated brass Operating TTemperature emperature -25C to +70C (consider de-rating) Climatic Category -25C/+70C/21 days (EN 60068-1..3) Stock Conditions +10C to +60C relative humidity 75% yearly average, without dew Dimensions (mm) Vibration Resistance 250,5 O5,2 +0,1 - 0,2 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60Hz at 0.75mm amplitude 60 - 2000Hz at 10g acceleration Marking Kappe mit Kennmelder cap with indicator , F, Current Rating, 250V Limits for Pre-arcing Time Rated Current 1.60A ... 6.3A 1.5 x IRated 2.1 x IRated 4 x IRated 10 x IRated > 1h < 30 min < 300ms < 20ms Permissible continuous operating current is 100 % at ambient temperature of 23C (73.4F). Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IRated 1.5 x IRated 10 x IRated max. (mV) max. (W) max. (A2s) 1.6A 2.0A 2.5A 4.0A 6.3A 1 1160 1200 1250 1400 1630 250V1 250V1 250V1 250V1 250V1 1500A @ 250 V AC 50Hz cos = 0.7 640 420 320 200 170 1.3 2.5 5.8 21.0 78.0 on request color of indicator orange blue yellow brown green Operating Voltage 10 V Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 012006 Qty. OrderNumber Series 240 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE Time (sec.) 5x25mm 5x25mm/ No. 240 I Fault / I Rated Contact Littelfuse for individual I-t curves 012006 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 5x25mm 5x25mm/ No. 241 Indicator Indicator,, 250V Specifications T ime-Current Packaging Characteristic Medium Time Lag (M) 002: Pack (100 pcs.) Standard Materials None Tube: End Caps: Approvals Ceramic Nickel-plated brass Operating TTemperature emperature None -25C to +70C (consider de-rating) Climatic Category -25C/+70C/21 days (EN 60068-1..3) Stock Conditions +10C to +60C relative humidity 75% yearly average, without dew Dimensions (mm) Ausf. / type: 80mA ... 1,25A O5,2 +0,1 - 0,2 Vibration Resistance 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60Hz at 0.75mm amplitude 60 - 2000Hz at 10g acceleration 250,5 Marking Kappe mit Kennmelder cap with indicator , M, Current Rating, 250V O5,2 +0,1 - 0,2 Ausf. / type: 1,6A ... 6,3A 250,5 Limits for Pre-arcing Time Rated Current 80mA ... 100mA 125mA ... 1.25A 1.6A ... 10A 1.5 x IRated 2.1 x IRated 2.75 x IRated <2min <2min <30min >1h - 4 x IRated 10 x IRated 40ms ... 500ms 60ms ... 2s 60ms ... 2s 5ms ... 30ms 5ms ... 70ms 5ms ... 70ms Permissible continuous operating current is 80 % at ambient temperature of 23C (73.4F). 80% Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IRated 1.5 x IRated 10 x IRated 2 max. (mV) max. (W) min. (A2s) 80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 500mA 630mA 800mA4 1A4 1.25A4 1.6A1 2A1 2.5A1 3.15A1 4A1 6.3A1 8A1 2 10A1 2 1 0080 0100 0125 0160 0200 0250 0315 0400 0500 0630 0800 1100 1125 1160 1200 1250 1315 1400 1630 1800 2100 1.6 ... 10A looks like No. 240 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 2 80A @ 250 V AC 50Hz cos = 1.0 1500A @ 250 V AC 50Hz cos = 0.7 520 500 500 400 400 375 410 280 250 220 400 350 315 480 360 300 250 180 160 160 0.015 0.030 0.053 0.11 0.23 0.38 0.60 0.75 1.5 2.3 3.0 4.5 6.8 2.3 4.5 7.5 30 34 140 170 260 on request 150 not mentioned in the norms 3 operating temperature 10V 4 color of indicator grey red velvet orange blue yellow black brown white green grey red velvet orange blue yellow black brown green grey red according to DIN 41576, T.2 Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 012006 Qty. OrderNumber Series 241 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE Time (sec.) 5x25mm 5x25mm/ No. 241 I Fault / I Rated Contact Littelfuse for individual I-t curves 012006 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 5x20 mm mm/ No. 311 Indicator Indicator,, 250 V Specifications Time-Current Packaging Mitteltrage (M) Characteristic 002: Pack (20 x 10 pcs.) Standard Materials DIN 41577, T.2 Tube: End Caps: Approvals None Ceramic Nickel-plated brass Operating TTemperature emperature -40 C to +85 C (consider de-rating) Climatic Category -40 C / +85 C / 21 days (IEC 60068-1,-2-1,-2-2,-2-78) Stock Conditions Dimensions (mm) +10 C to +60 C relative humidity 75 % yearly average, without dew O5,2 +0,1 - 0,2 Ausf. / type: 800mA ... 4A Vibration Resistance 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60 Hz at 0.75 mm amplitude 60 - 2000 Hz at 10 g acceleration 200,5 Marking Kappe mit Kennmelder cap with indicator , M, Current Rating, 250 V, G O5,2 +0,1 - 0,2 Ausf. / type: 6,3A 200,5 Limits for Pre-arcing Time Rated Current 1.5 x IN 2.1 x IN 2.75 x IN 800 mA ... 6.30 A >1h < 30 min - 4 x IN 10 x IN 60 ms ... 2 s 5 ms ... 70 ms Permissible continuous operating current is 80 % at ambient temperature of 23 C (73.4 F). Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IN 1.5 x IN 10 x IN max. (mV) max. (W) min. (A2s) 800 mA 1A 1.25 A 1.6 A 2A 2.5 A 4A 6.3 A 1 250 V2 250 V2 250 V2 250 V2 250 V2 250 V2 250 V2 250 V2 0800 1100 1125 1160 1200 1250 1400 1630 1500 A @ 250 V AC 50 Hz cos = 0.7 400 350 310 480 360 300 180 160 1.0 1.2 1.7 2.5 4.5 8.2 30.0 94.0 on request Approvals None 1 without gauge stud 2 operating voltage 10 V Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 050930 Qty. OrderNumber Series 311 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. WebSite www.littelfuse.com MINIA TURE FUSES INIATURE Time (sec.) 5x20mm 5x20mm/ No. 311 I Fault / I Rated Contact Littelfuse for individual I-t curves 050930 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. WebSite www.littelfuse.com MINIA TURE FUSES INIATURE 5x25mm 5x25mm/ No. 321 Indicator Indicator,, 250V Specifications Time-Current Packaging Mittetrage (M) Characteristic 002: Pack (100 pcs.) Standard Materials DIN 41577, T.2 Tube: End Caps: Approvals None Ceramic Nickel-plated brass Operating TTemperature emperature -25C to +70C (consider de-rating) Climatic Category -25C/+70C/21 days (EN 60068-1..3) Stock Conditions +10C to +60C relative humidity 75% yearly average, without dew O5,2 +0,1 - 0,2 Dimensions Vibration Resistance 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60Hz at 0.75mm amplitude 60 - 2000Hz at 10g acceleration 250,5 Marking Kappe mit Kennmelder cap with indicator , M, Current Rating, 250V, C Limits for Pre-arcing Time Rated Current 80mA ... 100mA 125 mA ... 630 mA 1.5 x IRated >1h 2.1 x IRated 2.75 x IRated <2min - 4 x IRated 10 x IRated 40ms ... 500ms 60ms ... 2s > 5ms Permissible continuous operating current is 80 % at ambient temperature of 23C (73.4F). 80% Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IRated 1.5 x IRated 10 x IRated max. (mV) max. (W) min. (A2s) 80mA 100mA 125mA 160mA 200mA 250mA 315mA 400mA 500mA 630mA 1 250V1 250V1 250V1 250V1 250V1 250V1 250V1 250V1 1 250V1 250V 0080 0100 0125 0160 0200 0250 0315 0400 0500 0630 80A @ 250 V AC 50Hz cos = 1.0 520 500 500 480 400 500 470 400 400 380 on request 0.015 0.030 0.053 0.11 0.23 0.38 0.53 0.75 1.5 2.3 color of indicator grey red velvet orange blue yellow black brown white green operating voltage 10 V Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 012006 Qty. OrderNumber Series 321 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. Specifications are subject to change without notice www.littelfuse.com MINIA TURE FUSES INIATURE Time (sec.) 5x25mm 5x25mm/ No. 321 I Fault / I Rated Contact Littelfuse for individual I-t curves 012006 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 6.3x32 mm / No. 354 Leadfree Special TType, ype, 440 V V,, F Specifications Time-Current Packaging Quick Acting (F) Characteristic 002: Pack (100 pcs.) Standard Materials None Tube: End Caps: Approvals Operating TTemperature emperature cULus Recognized: File No. E 67006 -25C to +70C (consider de-rating) Features For high voltage applications High breaking capacity Agency approved Pluggable into clips or shocksafe holders Dimensions (mm) Ceramic Nickel-plated brass Climatic Category -25C/+70C/21 days (EN 60068-1..3) Stock Conditions +10C to +60C relative humidity 75% yearly average, without dew, maximum value for 30 days-95% Vibration Resistance 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60Hz at 0.75mm amplitude 60 - 2000Hz at 10g acceleration 6,3 32 Marking , F, Current Rating, 440V, Approvals Unit Weight 3.0g (approx.) Limits for Pre-arcing Time 1.5 x IN 2.5 x IN 4 x IN 10 x IN 630 mA ... 800 mA 1.00 A ... 10.00 A >1h >1h < 30 min < 30 min 8 ms ... 400 ms 20 ms ... 1 s <20 ms <50 ms Permissible continuous operating current is 100 % at ambient temperature of 23 C (73.4 F). Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IN 1.5 x IN 10 x IN max. (mV) max. (W) max. (A2s) 630 mA 800 mA 1.00 A 1.25 A 1.60 A 2.00 A 2.50 A 3.15 A 1 4.00 A 1 5.00 A 1 6.30 A 1 8.00 A 1 10.00 A 1 0630 0800 1100 1125 1160 1200 1250 1315 1400 1500 1630 1800 2100 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 1000 A / 440 V AC 50-60 Hz cos = 1.0 600 550 500 470 420 320 300 270 230 200 190 180 170 1.1 1.3 1.6 2.0 2.2 2.4 2.6 2.9 3.2 3.5 3.8 4.0 4.0 0.12 0.32 0.33 1.8 2.0 5.3 9.0 23 43 78 150 280 500 Approvals cURus Rated Current * * * * * * * * * * * 1 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered. Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 011906 Qty. OrderNumber Series 354 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. Specifications are subject to change without notice www.littelfuse.com MINIA TURE FUSES INIATURE 00 0,0 10 6.3x32mm / No. 354 I-t Characteristics (Min-Max Limit) ,00 10 (630 ... 800mA) (1.00 ... 10.00A) 0 0 1,0 0 10 10 Time (sec.) 0 1 0.1 1 0.0 01 0.0 1 1.5 2 3 4 5 6 7 8 9 10 15 I Fault / I Rated Contact Littelfuse for individual I-t curves 011906 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 6.3x32 mm / No. 356 Leadfree Special TType, ype, 440 V V,, T Specifications T ime-Current Packaging Time Lag (T) Characteristic 002: Pack (100 pcs.) Materials Standard Tube: End Caps: None Approvals Operating TTemperature emperature cULus Recognized: File No. E 67006 -25C to +70C (consider de-rating) Features For high voltage applications Surge tolerant High breaking capacity Agency approved Pluggable into clips or shocksafe holders Dimensions (mm) Ceramic Nickel-plated brass Climatic Category -25C/+70C/21 days (EN 60068-1..3) Stock Conditions +10C to +60C relative humidity 75% yearly average, without dew, maximum value for 30 days-95% Vibration Resistance 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60Hz at 0.75mm amplitude 60 - 2000Hz at 10g acceleration 6,3 32 Marking , T, Current Rating, 440V, Approvals Unit W eight Weight 3.0g (approx.) Limits for Pre-arcing Time 400 mA ... 10.00 A 1.5 x IN 2.5 x IN 4 x IN >1h < 15 min 150 ms ... 2 s 10 x IN 10 ms ... 300 ms Permissible continuous operating current is 100 % at ambient temperature of 23C (73.4F). 100% Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IN 1.5 x IN 10 x IN max. (mV) max. (W) min. (A2s) 400 mA 500 mA 630 mA 800 mA 1.00 A 1.25 A 1.60 A 2.00 A 2.50 A 3.15 A 4.00 A 5.00 A 1 6.30 A 1 8.00 A 1 10.00 A 1 0400 0500 0630 0800 1100 1125 1160 1200 1250 1315 1400 1500 1630 1800 2100 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 1000A / 440VAC 50-60Hz cos = 1.0 1200 1100 800 700 500 350 320 270 250 230 200 180 150 140 120 1.5 1.6 1.7 1.7 1.8 1.8 1.8 2.0 2.3 2.4 2.6 3.0 3.2 3.8 4.0 0.16 0.53 2.0 3.1 4.4 3.1 8.3 9.2 22 36 62 91 130 240 510 Approvals cURus Rated Current * * * * * * * * * * * 1 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered. Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 012006 Qty. OrderNumber Series 356 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. Specifications are subject to change without notice www.littelfuse.com MINIA TURE FUSES INIATURE 00 0,0 10 6.3x32 mm / No. 356 I-t Characteristics (Min-Max Limit) ,00 10 0 0 1,0 0 10 10 Time (sec.) 0 1 0.1 1 0.0 01 0.0 1 1.5 2 3 4 5 6 7 8 9 10 15 I Fault / I Rated Contact Littelfuse for individual I-t curves 012006 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com MINIA TURE FUSES INIATURE 6.3x32mm / No. 358 Leadfree Special TType, ype, 500 V V,, T Specifications T ime-Current Packaging Time Lag (T) Characteristic 002: Pack (100 pcs.) Standard Materials Features Operating TTemperature emperature Tube: End Caps: None For high voltage applications Surge tolerant High breaking capacity Pluggable into clips or shocksafe holders Ceramic Nickel-plated brass -25 C to +85 C (consider de-rating) Climatic Category -25 C/+70 C/21 days (EN 60068-1,-2-1,-2-2,-2-78) Stock Conditions Dimensions (mm) +10 C to +60 C relative humidity 75 % yearly average, without dew, maximum value for 30 days-95 % Vibration Resistance 6,3 24 cycles at 15 min. each (EN 60068-2-6) 10 - 60 Hz at 0.75 mm amplitude 60 - 2000 Hz at 10 g acceleration 32 Marking , T, Current Rating, 500V, Approvals Unit Weight 3.0 g (approx.) Limits for Pre-arcing Time 1.5 x IN 3.15 A ... 10.00 A >1h 2.5 x IN 4 x IN < 15 min 150 ms ... 2 s 10 x IN 10 ms ... 300 ms Permissible continuous operating current is 100 % at ambient temperature of 23 C (73.4 F). Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral Current Code Rating Capacity 1.0 x IN 1.5 x IN 10 x IN max. (mV) max. (W) min. (A2s) 3.15 A 4.00 A 1 5.00 A 1 6.30 A 1 8.00 A 1 10.00 A 1315 1400 1500 1630 1800 2100 500 V 500 V 500 V 500 V 500 V 500 V 1500 A / 500 V AC 50-60 Hz cos = 1.0 220 200 180 150 140 120 2.3 2.6 3.0 3.2 3.8 4.0 18 41 62 123 250 500 Approvals cURus Rated Current * * * * * * 1Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered. p=pending Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 011706 Qty. OrderNumber Series 358 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. Specifications are subject to change without notice www.littelfuse.com MINIA TURE FUSES INIATURE 00 0,0 10 6.3x32mm / No. 358 I-t Characteristics (Min-Max Limit) ,00 10 0 0 1,0 0 10 10 Time (sec.) 0 1 0.1 1 0.0 01 0.0 1 1.5 2 3 4 5 6 7 8 9 10 15 I Fault / I Rated Contact Littelfuse for individual I-t curves 011706 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com