Model Ihold I
Trip V
max. dc I
max. max. time to trip Pd max. Resistance Approvals
(A) (A) (V) (A) (s @ A) (W) R min.()
R max.()
RI max.()
Order Qty. Order- Model Packaging
Information Number
VTD170 1.70 3.40 15 100 3.0 @ 8.5 1.40 0.030 0.052 0.105
VTD170XS 1.70 3.40 15 100 3.0 @ 8.5 1.40 0.030 0.052 0.105
VTD175 1.75 3.80 15 100 3.0 @ 8.5 1.40 0.025 0.045 0.045
VTD175S 1.75 3.80 15 100 3.0 @ 9.0 1.40 0.025 0.045 0.090
VTD175L 1.75 3.80 15 100 3.0 @ 9.0 1.40 0.025 0.045 0.090
VTD175XL 1.75 3.80 15 100 5.0 @ 8.75 1.40 0.029 0.051 0.102
VTD200 2.00 4.50 15 100 4.0 @ 10.0 1.50 0.021 0.039 0.080
VTD200 2.00 4.50 15 100 4.0 @ 10.0 1.50 0.021 0.039 0.080
VTD210 2.10 4.70 15 100 5.0 @ 10.0 1.50 0.018 0.030 0.060
VTD210S 2.10 4.70 15 100 5.0 @ 10.0 1.50 0.018 0.030 0.060
VTD210SS 2.10 4.70 15 100 5.0 @ 10.0 1.50 0.018 0.030 0.060
VTD210L 2.10 4.70 15 100 5.0 @ 10.0 1.50 0.018 0.030 0.060
VTD210LS 2.10 4.70 15 100 5.0 @ 10.0 1.50 0.018 0.030 0.060
VTD240 2.40 5.40 15 100 4.0 @ 12.0 1.50 0.015 0.026 0.052
Dimensions (mm)
S: one slot
SS: two slots
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
041006 www.littelfuse.com
POLYFUSE® RESETTABLE FUSES
Permissible continuous operating current is 100 % at ambient temperature of 20 ºC (68 ºF).
Speci cations
Packaging
A small pack
D standard
Materials
Insulating material: Polyester Tape
Terminals: Nickel
Max. Device Surface Temperature in Tripped State
110 °C
Operating / Storage Temperature
-40 ºC to +85 ºC (consider derating)
Humidity Ageing
+60 °C, 95 % R.H., 1000 hours, ± 10 % typical
resistance change
Vibration
MIL-STD-883C, Condition A, no change
Thermal Shock
MIL-STD-202F, Method 107G
+85 °C to -40 °C 10 times ±5 % typical resistance
change
Marking
“P”, Part Code, identi cation, lot number
Strap Type, 16 V
Standard
UL 1434 1st Edition
CSA C22.2 No. 0 CSA TIL No. CA-3A
Approvals
cULus Recognition
TÜV
Features
The new VTD product series feature a slim, low
pro le and low resistance design. These devices
are ideal to be installed directly onto the latest
generation batteries including cylindrical and
prismatic cells. The VTD product offers protec-
tion against both overcurrent and overtempera-
ture fault conditions.
VTD
Dimensions (mm)
Model A B C D E F pack ag ing quantity
Fig Min Max Min Max Min Max Min Min Max Min small pack standard
VTD170 1 15.4 17.5 7.0 7.4 0.5 0.8 4.0 3.9 4.1 500 10,000
VTD170XS 2 20.9 22.9 4.9 5.3 0.5 0.8 4.0 3.9 4.1 500 10,000
VTD175 1 20.9 22.2 3.5 3.8 0.5 0.7 4.0 2.9 3.1 500 10,000
VTD175S 2 20.9 22.2 3.5 3.8 0.5 0.7 4.0 2.9 3.1 500 10,000
VTD175L 1 26.0 28.0 3.5 3.8 0.5 0.8 6.5 2.9 3.1 500 10,000
VTD175XL 4 25.5 28.2 3.5 3.9 0.5 0.8 8.7 2.4 2.6 5.7 500 10,000
VTD200 1 20.9 23.1 3.8 4.3 0.6 0.7 4.0 2.9 3.1 500 10,000
VTD200S 2 20.9 23.1 3.8 4.3 0.6 0.7 4.0 2.9 3.1 500 10,000
VTD210 1 20.9 23.1 4.9 5.3 0.6 0.8 4.1 3.9 4.1 500 10,000
VTD210S 2 20.9 23.1 4.9 5.3 0.6 0.8 4.1 3.9 4.1 500 10,000
VTD210SS 3 20.9 23.1 4.9 5.3 0.6 0.8 4.1 3.9 4.1 500 10,000
VTD210L 1 24.0 26.0 4.9 5.3 0.6 0.8 5.0 3.9 4.1 500 10,000
VTD210LS 2 24.0 26.0 4.9 5.3 0.6 0.8 5.0 3.9 4.1 500 10,000
VTD240 1 24.2 26.2 4.9 5.3 0.6 0.8 5.0 3.9 4.1 500 10,000
NOTE:
I hold = Hold current: maximum current device will pass without tripping in 20 °C still air.
I trip = Trip current: minimum current at which the device will trip in 20 °C still air.
Vmax = Maximum voltage device can withstand without damage at rated current (I max)
I max = Maximum fault current device can withstand without damage at rated voltage (Vmax)
Pd = Power dissipated from device when in the tripped state at 20 °C still air.
R min= Minimum resistance of device in initial (un-soldered) state.
R 1max= Maximum resistance of device at 20 °C measured one hour after tripping for 20 s.
Caution: Operation beyond the speci ed rating may result in damage and possible arcing and ame.
Speci cations are subject to change without notice
Thermal Derating Chart
Model Ambient Operation Temperature - Ihold (A)
-40 °C -20 °C 0 °C 23 °C 40 °C 50 °C 60 °C 70 °C 85 °C
VTD170 3.20 2.70 2.20 1.70 1.30 1.00 0.80 0.50 0.10
VTD170XS 3.20 2.70 2.20 1.70 1.30 1.00 0.80 0.50 0.10
VTD175 3.20 2.70 2.20 1.75 1.30 1.00 0.80 0.50 0.10
VTD175S 3.20 2.70 2.20 1.75 1.30 1.00 0.80 0.50 0.10
VTD175L 3.20 2.70 2.20 1.75 1.30 1.00 0.80 0.50 0.10
VTD175XL 3.20 2.70 2.20 1.75 1.30 1.00 0.80 0.50 0.10
VTD200 3.70 3.20 2.60 2.00 1.50 1.20 0.90 0.50 0.10
VTD200S 3.70 3.20 2.60 2.00 1.50 1.20 0.90 0.50 0.10
VTD210 4.10 3.50 2.90 2.10 1.60 1.30 1.00 0.70 0.10
VTD210S 4.10 3.50 2.90 2.10 1.60 1.30 1.00 0.70 0.10
VTD210SS 4.10 3.50 2.90 2.10 1.60 1.30 1.00 0.70 0.10
VTD210L 4.10 3.50 2.90 2.10 1.60 1.30 1.00 0.70 0.10
VTD210LS 4.10 3.50 2.90 2.10 1.60 1.30 1.00 0.70 0.10
VTD240 4.40 3.70 3.10 2.40 1.80 1.50 1.20 0.90 0.10
A: VTD170
B: VTD210
1.00 10.00 100.00
Fault Current (A)
0.01
0.10
1.00
10.00
100.00
Time-to-Trip (s)
AB
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
041006 www.littelfuse.com
POLYFUSE® RESETTABLE FUSES
VTD
Further Time-Current-Curves on request
Mouser Electronics
Authorized Distributor