86 Compensated
86C www.meas-spec.com August 2011
2/4
PERFORMANCE SPECIFICATIONS
Supply Current: 1.5mA
Ambient Temperature: 25° C (unless otherwise specifi ed)
PARAMETERS 005PSI ≥015PSI UNITS NOTES
MIN TYP MAX MIN TYP MAX
Span 50 100 150 75 100 150 mV 1
Zero Pressure Output -2.0 0 2.0 -1.0 0 1.0 mV 2
Pressure Non Linearit y -0.2 0.2 -0.1 0.1 %Span 3
Pressure Hysteresis -0.10 ±0.02 0.10 -0.05 ±0.02 0.05 %Span
Repeatability ±0.02 ±0.02 %Span
Input Resistanc e 2.5K 5.0K 6.5K 2.0K 3.5K 5.8K Ω
Output Resistance 4.0K 7.0K 4.0K 6.0K Ω
Temperature Error – Span -1.0 1.0 -0.75 0.75 %Span 4
Temperature Error – Offset -1.5 1.5 -0.50 0.50 %Span 4, 5
Thermal Hysteresis – Span -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 4
Thermal Hysteresis – Offset -0.25 ±0.05 0.25 -0.25 ±0.05 0.25 %Span 4
Long Term Stability – Span ±0.10 ±0.10 %Span/Year
Long Term Stability – Offset ±0.25 ±0.10 %Span/Year
Supply Current 0.5 1.5 2.0 0.5 1.5 2.0 mA 6
Output Load Resistance 5M 5M Ω 7
Insulation Resist ance (50Vdc) 50M 50M Ω 8
Output Noise (10Hz to 1KHz) 1.0 1.0 uV p-p
Response Time (10% to 90%) 0.1 0.1 ms
Pressure Overload 3X 3X Rated
Pressure Burst 4X 4X Rated 9
Compensated Temperature 0 50 -20 +85 °C
Operating Temperature -20 +70 -40 +125 ºC 10
Storage Temperature -50 +125 -50 +125 ºC 10
Media – Pressure Port Liqui ds and Gases compatible with 316/316L Stainless Steel
Media – Reference Port Compatible with Silicon, Pyrex, Gold, Fluoros i l ic one Rubber, and 316/316L Stai nl ess
Steel
Notes
1. For amplifi ed output circuits, 3.012V ±1% interchangeability with gain set resistor. See application sc hematic.
2. Measured at vacuum for absolute (A) and at ambient for gage (G).
3. Best fit straight l i ne.
4. Over t he compensated temperature range with respect to 25°C.
5. 15-psi range sensors have a temperature error of °0.75% (max) of zero from -20° C to +85°C.
6. Guarantees out put/ i nput rat i ometrici ty.
7. Load resist anc e to reduce measurement errors due to output loading.
8. Between case and sensing element.
9. The maximum pressure that can be applied to a transduc er without rupture of either the sensing element or transduc er.
10. Maximum tem perature range for product with standard cable and connector is -20°C to +105°C.