W A T L O W
113
Infrared Sensors
Infrared Sensors
Raytek®Family
Noncontact Temperature
Measurement
Watlow offers a wide variety of
Raytek®infrared thermometers that
monitor and control temperature in
various manufacturing processes.
These thermometers measure
temperature of fast moving
processes quickly and efficiently.
They measure the temperature of the
product directly, instead of the oven
or the dryer. This allows you to
quickly adjust to process parameters
to ensure top product quality.
Infrared thermometers are easily
integrated into existing process
control systems and have the
following benefits:
Non-destructive: the product is
never touched or contaminated
Fast and reliable: moving objects
are measured accurately and
quickly
Flexible: temperature
measurements can be made of a
large area or a small spot
Small Size, Big Features
These products may be compact,
but do not compromise on features.
Using advanced micro-fabrication
techniques, the cost and size of
these sensors remain small while
retaining sophisticated features such
as emissivity, signal conditioning
and t-ambient processing. The wide
temperature range in each model
allows you to detect process
variations and monitor start-up
performance.
Infrared Thermocouples
If you are looking for a low-
maintenance solution for infrared
thermocouples, consider the MI™ or
CI™. The MI™, a two-piece system
with miniature sensing head and
separate electronics, features
adjustable emissivity and selectable
peak hold, valley hold and
averaging.
The CI™ is a compact, integrated
unit with the same output impedance
as a thermocouple. It functions
accurately—without offset errors—
when used in conjunction with the
thermocouple break protection
circuitry in most controllers, displays
and transmitters.
Both the MI™ and CI™ have rugged
stainless steel housings to ensure
continuous, long-term performance,
even in environments with high
ambient temperatures.
An Affordable Solution for
Your Process
The miniature size and low cost of
the MI™ (shown above) make it an
ideal configuration for installation at
multiple points along your process.
The sensor is isolated from the
electronics box which allows it
to withstand ambient temperatures
up to 200°C (392°F) with cooling
accessories.
Whether you choose a modular system
based on the GP™ monitor, or the
MI™ or CI™, we have a compact,
value-priced infrared thermometer to
meet your needs. Cooling jackets, air
purge collars and other accessories
are available to ensure accurate
performance regardless of your
environment.
Raytek®Service Ensures Long
Use
With over 30 years experience,
Raytek®knows infrared temperature
measurement. Application
specialists are available to help
answer your technical questions.
Each product includes a two year
warranty. In addition, maintenance,
training, calibration and other
customized services are available to
ensure that you receive the
maximum benefits from your Raytek®
infrared, noncontact thermometer.
For more information on Raytek®
infrared temperature measurement
solutions, contact your Watlow sales
agent or applications specialist
today.
*Must specify at time of order.
Raytek®is a registered trademark of the Raytek Corporation. MiniTemp™, ST
ProPlus™, GP™, CI™ and MI™ are trademarks of Raytek Corporation.
Temperature Signal Power
Product Range Accuracy Processing Display Supply Outputs
GP™ Monitor
-18 to 540°C 1 percent Adjustable Yes
110-220VÅ(ac)
Thermocouple
w/ GPR™ (0 to 1000°F) 4-20mA
& 2 Alarms
GP™ Monitor
0 to 500°C 2 percent Adjustable Yes
110-220VÅ(ac)
Thermocouple
w/ CI™ (0 to 1000°F) 4-20mA
w/ 2 models & 2 Alarms
MI™ -40 to 600°C 1 percent Adjustable No 12-24VÎ(dc) 4-20mA,
(-40 to 1112°F) J or K T/C,
or mV
CI™ 0 to 500°C 2 percent N/A No 12-24VÎ(dc) *J or K T/C,
(32 to 932°F) or mV
w/ 2 models
114
Raytek®MI™
RAYMID10LTCB3 MI electronics and sensing head with 10:1 optics and 9.8 ft (3 m) cable
RAYMID10LTCB8 MI electronics and sensing head with 10:1 optics and 26 ft (8 m) cable
XXXMIACAB Adjustable bracket for MID
XXXMIACAJ MI air purge jacket (no cooling)
XXXMIACCJ MI air cooling and purging system with 2.8 ft (0.8 m) insulated air hose
XXXMIACCJ1 MI air cooling and purging system with 9.2 ft (2.8 m) insulated air hose
XXXMIACFB MI sensor head fixed mounting bracket
XXXMIACMN MI sensor head mounting nuts (5)
Raytek®CI™
RAYCI1A Type J output sensing head w/1 m cable, ± 3°C accuracy 0 to 115°C
5.4°F, 32 to 240°F)
RAYCI1A10L Type J output sensing head w/3 m cable (MAX 105°C, 220°F),
± Caccuracy 0 to 115°C (± 5.4°F, 32 to 240°F)
RAYCI1B Type J output sensing head w/1m cable, ± Caccuracy 100 to 500°C
5.4°F, 202 to 932°F)
RAYCI1B10H Type J output sensing head w/3m high temp cable (MAX 260°C, 500°F),
± Caccuracy 100 to 500°C (± 5.4°F, 202 to 932°F)
RAYCI1B10L Type J output sensing head w/3m cable (MAX 105°C, 220°F),
± 3°C accuracy 100 to 500°C (± 5.4°F, 202 to 932°F)
RAYCI2A Type K output sensing head w/1m cable, ± Caccuracy 0 to 115°C
5.4°F, 32 to 240°F)
RAYCI2A10L Type K output sensing head w/3m cable (MAX 105°C, 220°F),
± Caccuracy 0 to 115°C 5.4 F, 32 to 240°F)
RAYCI2B Type K output sensing head w/1m cable, ± 3°C accuracy 100 to 500°C
5.4°F, 202 to 932°F)
RAYCI3A10L Linear voltage output sensing head w/3m cable (MAX 105°C, 220°F),
± Caccuracy 0 to 115°C (± 5.4°F, 32 to 240°F)
XXXCIACAP Air purge collar for CI
XXXCIACFB Fixed bracket for CI
XXXCIACMN Mounting nuts (2) for CI
XXXCIADJB Adjustable bracket for CI
XXXCIAP Air purge collar (aluminum) for CI
XXXCIDCPS 24VÎ(dc), 125mA switching power supply (110/220V input)
Raytek®GP™
RAYGPC GPC panel-mount meter with standard 5VÎ(dc) alarm outputs, 110/220VÅ(ac) power input
RAYGPRSF GPR standard focus sensing head with 8-14 micron spectral response
and 35:1 optical resolution
XXXGPACFB GPC mounting bracket for sub-panel mounting of monitor
XXXGPRCB15 50 ft (15 m) 5 conductor cable with 5-pin bayonet connector
MiniTemp™
RAYMT4U Enhanced MiniTemp MT4 model with class 2 laser sighting
RAYMTAPK Nylon carrying pouch with belt clip
ST™ Pro
RAYST20XBUS ST 20 Pro™ eXtra-Bright
ST™ ProPlus
RAYST60XBUS ST 60 ProPlus™ eXtra-Bright
RAYST80XBUS ST 80 ProPlus™ eXtra-Bright
RAYST80XBUS-IS ST 80 ProPlus™ eXtra-Bright intrinsically safe
I
In
nf
fr
ra
ar
re
ed
d T
Th
he
er
rm
mo
oc
co
ou
up
pl
le
es
sD
De
es
sc
cr
ri
ip
pt
ti
io
on
n
Infrared Sensors
Raytek®Family
Product Offering
T
Te
em
mp
pe
er
ra
at
tu
ur
re
e M
Mo
on
ni
it
to
or
ri
in
ng
g S
Sy
ys
st
te
em
m
D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
H
Ha
an
nd
d H
He
el
ld
d I
IR
R T
Th
he
er
rm
mo
om
me
et
te
er
rs
sD
De
es
sc
cr
ri
ip
pt
ti
io
on
n
Items in bolded green type are stocked for immediate availability.
W A T L O W
115
Infrared Sensors
Infrared Sensors
Hand Held
MiniTemp™
The Raytek®MiniTemp™ is pocket-
sized and easy to use—just point,
shoot and read the temperature on
the large backlit display. When you
need a fast, easy and safe way to
measure surface temperature, you
need a MiniTemp™ noncontact
thermometer. Use MiniTemp™ at
work, at home, anywhere.
Choice of Models
Choose between MiniTemp™ MT2,
no laser sighting, or MiniTemp™
MT4, with laser sighting. Both
models are powered by a 9V battery
and display temperatures in either
°C or °F. An accessory pack
including a pouch and wrist strap is
also available.
Applications
Blown film extrusion
Cast film extrusion
Originally oriented film extrusion
Sheet extrusion
Extrusion coating
Laminating and bossing
Thermoforming
Models MT2 MT4
Specifications
Options/Accessories
Soft Pouch with Wrist Strap
25 mm @
200 mm 50 mm @
400 mm 75 mm @
600 mm
1 in. @
8 in. 2 in. @
16 in. 3 in. @
24 in.
D
S
D
S
8
1
=
D:S = 8:1 at focal point
Target Spot Sizes
*For more information on emissivity for unique applications visit www.raytek.com/emissivity.htm
**U.S. only. Warranty duration may vary by country.
Temperature range -18 to 275°C (0 to 525°F)
Accuracy -1 to 275°C (30 to 525°F) ±2% or ±2°C
(±3.5°F), whichever is greater,
-18 to -1°C (0 to 30°F) ±3°C (±5°F)
Repeatability ±2% of reading or ±2°C (±3°F), whichever
is greater
Response time 500mSec, 95% response
Spectral response 7-18 µm
Emissivity* Pre-set 0.95
Ambient operating range 0 to 50°C (32 to 120°F)
Relative humidity 10-95% RH non-condensing, @ up to
30°C (86°F)
Storage temperature -20 to 65°C (-4° to 150°F) without battery
Weight/dimensions 0.5 lb (227g); 6 X 4 X 1.5 in.
(152 X 101 X 38 mm)
Power 9V Alkaline or NiCd battery (included)
Battery life (Alkaline) 22 hours 12 hours
Laser Class II
Distance to spot size 8 :1
Typical distance to target (spot)
Up to 4 ft (1.5 m)
Display hold (7 seconds) √√
LCD backlit √√
Temperature display °C or °F selectable
Display resolution 0.2°C (0.5°F)
Options/accessories Nylon holster
Warranty 1 year**
116
Infrared Sensors
Hand Held
ST Pro™ 20 XB
Choose the ST Pro™ XB when you
need a dependable professional tool
for day-to-day applications. You
won’t find other noncontact
thermometers with the temperature
range, ability to measure so small an
area and comparable laser sighting
at this price. Simply point, shoot and
read.
With a wide temperature range, MAX
temperature display and choice of
laser sighting options, the ST Pro™
makes temperature measurement a
breeze. The ST20XB features
rugged rubber overmolding and the
ability to be tripod mounted.
Choose the infrared noncontact
thermometer that millions of
professionals use worldwide. Call
today and discover the advantage—
fast, easy and safe temperature
measurement backed by over 40
years of experience. Raytek®Infrared Noncontact
Thermometers are the
professional’s choice for:
Blown film extrusion
Cast film extrusion
Originally oriented film extrusion
Sheet extrusion
Extrusion coating
Laminating and bossing
Thermoforming
Hazardous locations (ST80-IS)
W A T L O W
117
Infrared Sensors
Temperature range -32 to 535°C (-25 to 999°F)
Accuracy -32 to 26°C (-25 to -15°F): ±3°C (±5°F)
(Assumes ambient operating -26 to -18°C (-15 to 0°F): ±2.5°C (±4°F)
temperature of 23°C (73°F)) -18 to 23°C (0 to 73°F): ±2°C (±3°F)
23 to 510°C (73 to 950°F): ±1% of reading
or ±1°C (±2°F), whichever is greater
Above 510°C (950°F): ±1.5% of reading
Repeatability ±0.5% or ±1°C (±2°F), whichever is greater
Response time 0.5 second (95% of reading)
Spectral response 8-14 µm
Emissivity* Pre-set at 0.95
Ambient operating temp. 0 to 50°C (32 to 120°F)
Relative humidity
10-90% RH non-condensing at <30°C (86°F) ambient
Storage temperature -20 to 60°C (-13 to 158°F) without battery
Weight/dimensions 11 oz (320 g), 8 X 6 X 2 in.
(200 X 160 X 55 mm)
Power 9V Alkaline or NiCd battery
Battery life (Alkaline) 10 hours w/laser & backlight on
20 hours w/laser & backlight off
Laser (class II) Offset single point laser point XB
Typical distance to target Up to 6 ft (2 m)
Distance to spot (D:S) 12:1 at focus point
MAX temp display
Display hold (7 seconds)
LCD backlit
Temperature display °C or °F selectable
Display resolution 0.2°C (0.5°F)
Hard carrying case
Tripod mounting
Warranty* 1 year
Additional options/accessories
Nylon holster
NIST/DKD traceable calibration certificate
(includes one year warranty)
Models ST20 XB
Specifications
1.5 in.@
12 in.
3 in.@
36 in.
5.3 in.@
60 in.
ST20XB Target Spot Sizes
D:S = 12:1 at Focus Point
Infrared Sensors
Hand Held
ST Pro™ 20 XB
*U.S. only. Warranty duration may vary by country.
118
Infrared Sensors
Hand Held
ST ProPlus™ 60/80 XB
When you need more features and
higher specifications, choose the
ProPlus™ for your most demanding
applications. Advanced infrared
technology for reading higher
temperatures and powerful optics for
measuring smaller areas (or from
farther back), make the ProPlus™
the professional’s choice for
noncontact temperature measure-
ment. Whether you choose the ST60
or the ST80, gathering temperature
data has never been easier. Simply
point, shoot and read.
Innovative features like extra bright
laser sighting, adjustable emissivity,
a wide temperature range and 12
point data logging, make any
temperature measurement
application a snap. This rugged
unit with rubber overmolding also
includes a jack for the optional
Raytek®ST RTD temperature probe,
and can be tripod mounted for
hands-free operation. The ST80 is
also available in a model rated
“Intrinsically Safe” by Factory Mutual
Research for use in hazardous
locations.
Raytek®Infrared Noncontact
Thermometers are the
professional’s choice for:
Blown film extrusion
Cast film extrusion
Originally oriented film extrusion
Sheet extrusion
Extrusion coating
Laminating and bossing
Thermoforming
Hazardous locations (ST80-IS)
Options/Accessories
RTD temperature probe
Nylon holster
NIST traceable calibration
certificate
Factory Mutual Research
Intrinsically Safe Rated ST80-IS,
including probe (Intrinsically Safe,
Class 1 Division 1 Groups
A,B,C,D Class I, Zone 0, AEx ia
IIC, T4 at 50°C (122°F) when used
with 9V alkaline battery)
W A T L O W
119
Infrared Sensors
Infrared Sensors
Hand Held
ST ProPlus™ 60/80 XB
0.9 in.@
12 in.
24 mm@
300 mm
30 mm@
900 mm
62 mm@
1500 mm
1.2 in.@
36 in.
2.5 in.@
60 in.
0.8 in.@
12 in.
0.7 in.@
36 in.
1.7 in.@
60 in.
19 mm@
300 mm
18 mm@
900 mm
42 mm@
1500 mm
ST60 ProPlus™ Target Spot Sizes
D:S = 30:1 at Focus Point
ST80 ProPlus™ Target Spot Sizes
D:S = 50:1 at Focus Point
Temperature range -32 to 600°C -32 to760°C
(-25 to 1100°F) (-25 to 1400°F)
Accuracy -32 to 26°C (-25 to -15°F): ±3°C (±5°F)
(Assumes ambient operating -26 to -18°C (-15 to 0°F): ±2.5°C (±4°F)
temperature of 23°C (73°F)) -18 to 23°C (0 to 73°F): ±2°C (±3°F)
For targets above 23°C (73°F): ±1% of reading
or ±1°C (±2°F), whichever is greater
Repeatability ±0.5% or ±1°C (±2°F), whichever is greater
Response time 0.5 second (95% of reading)
Spectral response 8-14 µm
Emissivity** Digitally adjustable emissivity
(from 0.1 to 1.0 by 0.01)
Ambient operating temp. 0 to 50°C (32 to 120°F)
Relative humidity 10-90% RH non-condensing,
at <30°C (86°F) ambient
Storage temperature -20 to 60°C (-13° to 158°F) without battery
Weight/dimensions 11 oz (320 g); 8 X 6 X 2 in.
(200 X 160 X 55 mm)
Power 9V Alkaline or NiCd battery
Battery life (Alkaline) 20 hours w/laser & backlight on 50%
40 hours w/laser & backlight off
Laser sighting (class II) Extra bright laser point
Typical distance to target 15 ft (5 m) 25 ft (8 m)
Distance to spot (D:S) 30:1 at focus point 50:1 at focus point
MIN, MAX, AVG, DIF
temp display
Data logging 12 points
Probe jack
Display hold (7 seconds)
Hi/Low alarm
LCD backlit
Temperature display °C or °F selectable
Display resolution 0.1°C (0.1°F)
Hard carrying case
Locking trigger
Tripod mounting 0.25 in. (6.35 mm) 20 UNC threading
Models ST60 XB
ST80 XB / ST80 XB-IS*
Specifications
*Approved by Factory Mutual Research for use in hazardous locations.
**For more information on emissivity, or for unique applications visit www.raytek.com/emissivity.htm
120
Infrared Sensors
Fixed Mount
Raytek®GP™ Sensor
The GP™ sensor is a versatile, two-
piece temperature monitoring
system which combines a compact,
value-priced monitor with an infrared
sensing head. The heart of the
system is the 18DIN GP™ monitor
which provides advanced infrared
processing capabilities including
peak and valley hold, averaging
and a user-adjustable offset. The
rugged GPR sensor is available with
standard- or close-focus optics
and provides target temperature
readings with one percent accuracy.
Along with its large four-digit LED
display, the monitor provides a user-
defined 4-20mA or thermocouple
output. Two adjustable set points/
deadbands control 5V alarm outputs
or optional 3A mechanical relays.
The GP monitor accepts universal
110-220VÅ(ac) power and provides
a 24VÎ(dc)/50mA excitation voltage
for loop power to external sensors.
All monitor functions are configured
via the front panel, including °C/°F
switching.
The GP™ monitor provides
adjustable emissivity when used
with the GPR™ infrared sensor. This
high performance, eight to 14 micron
infrared sensor with detachable
cable combines current loop driven
signals with 35:1 optics.
The GP™ monitor also works with
other Raytek®infrared sensors,
including the CI™ and MID™.
Highlights
• Temperature range from -18 to
538°C (0 to 1000°F)
Compact 18DIN digital monitor
with large four-digit display
Monitor and sensor functions
configured on front panel
Signal processing capabilities
typically found on much larger
systems
Adjustable emissivity
Universal 110-220VÅ(ac) power
User-defined 4-20mA or thermo-
couple output (J,K,E,N,R,S,T)
Adjustable dual set points and
deadband alarm outputs
Choice of sensing head to match
application requirements
Standard- and close-focus optics
available
Accessories for cooling and air
purging
Field interchangeable sensing
heads
Accessories/Options:
Cooling housings for high ambient
conditions
Air purge fittings for sensing
heads
Adjustable mounting brackets and
adapters
External isolated solid state relays
for alarm outputs (10 Amp AC)
3A mechanical output relays
W A T L O W
121
Infrared Sensors
Infrared Sensors
Fixed Mount
Raytek®GP™ Sensor
Sensing Head —
Optical Specifications
(Note: nominal spot size based on 90 percent energy)
GPR Sensing Head Optical Charts
Dimensions
GPR Sensing Head
0.23
(6)
0.5
(13)
4.92
(125) 1.18
(30)
1.5
(38)
1.65
(42)
in. (mm)
1.5 in.
(38)
20 UN-2A
Temperature range -18 to 538°C
(0 to 1000°F)
Accuracy (mA output) ±1% of measured value or ±1°C (±2°F),
whichever is greater, @ 23°C ±5°C (73°F ±9°F)
Repeatability ±0.5% of measured value or
±1°C (2°F), whichever is greater
Response time (95 percent) 700mSec
Spectral response 8-14 µm
Emissivity 0.1 to 1.09 digitally adjustable increments of 0.01
Signal processing Peak/valley hold (up to 998 sec, 999=infinite
hold with external reset) Variable averaging
filter (up to 60 seconds) T-ambient: fixed
background ambient temperature compensation
Model GPR
Measurement Specifications (Monitor with Sensing Head)
*GPR rated with adapter and compression fitting.
Outputs 4-digit, 7 segment LED display, °C/°F selectable.
User configurable 4-20mA current or
thermocouple output (J, K, E, N, R, S, T).
Two adjustable set points with deadbands
controlling +5V alarm outputs or optional 3A
mechanical relay
Power supply 110/220VÅ(ac), ±20 percent, 50-60Hz.
User configurable inputs for GPR, GPM, any
0.5V or 4-20mA sensor or thermocouple
(J, K, E, N, R, S, T).
External reset input to reset peak/valley hold
24VÎ(dc)/50mA excitation voltage
GPR Electrical Specifications
Environmental rating
GP monitor front panel IP 54 (IEC 529); NEMA-12
GPR sensing head IP 65 (IEC 529); NEMA-4*
Ambient temperature range
GP monitor 0 to 50°C (32 to 120°F)
GPR sensing head 0 to 65°C (32 to 150°F)
with optional water cooling 0 to 177°C (32 to 350°F)
Storage temperature -30 to 65°C (-22 to 150°F)
Relative humidity 10 to 95% non-condensing
GP monitor dimensions 1.75 X 3.63 X 4.75 in. (18DIN X 120 mm)
GP monitor weight 0.7 lbs (320 g)
General Specifications
122
Infrared Sensors
Fixed Mount
Raytek®GP™ Monitor
The GP™ monitor provides a
compact, easy-to-use interface and
display for process instruments.
This low-cost 18DIN digital panel
meter comes standard with features
which are optional on other panel
meters in this price range. The GP™
monitor accepts inputs from any
0-5V sensor, 4-20mA sensor or
thermocouple type J,K,E,N,R,S,T.
In addition, the monitor can be
used with many Raytek®noncontact,
infrared temperature sensors.
Along with it’s large four-digit LED
display, the monitor provides a
user-defined 4-20mA or thermo-
couple output. Two adjustable set
points/deadbands control 5V alarm
outputs or optional 3A mechanical
relays. The GP™
monitor accepts 110-220VÅ(ac)
power and provides a 24VÎ(dc)/50
mA excitation voltage, capable of
providing loop power to external
sensors.
For signal processing requirements,
the monitor provides peak hold,
valley hold and averaging and a
user adjustable offset. Best of all,
there are no internal jumpers used
for setup, as all monitor functions
are configured via the front panel.
Versatile. Compact. Value-priced.
All reasons to standardize on the
GP™ monitor for your process
monitoring requirements.
Highlights
Accepts any 0-5V or 4-20mA
sensor input
Accepts Type J, K, E, N, R, S, T
thermocouple inputs
Compact 18DIN monitor
Large four-digit LED display
Universal 110/220VÅ(ac) power
Provides 24VÎ(dc) / 50mA
excitation voltage
User defined 4-20mA or thermo-
couple output (J,K,E,N,R,S,T)
Adjustable dual set points and
deadband controlling alarm
outputs
Signal processing: peak hold,
valley hold, averaging
User adjustable offset
External reset input
W A T L O W
123
Infrared Sensors
Infrared Sensors
Fixed Mount
Raytek®GP™ Monitor
General Dimensions
Panel cut-out: 1.75 in. x 3.63 in.
(92 mm x 44 mm)
Accessory — Solid State Relay
External isolated solid state relays for
alarm outputs (10 amp AC)
4.13 in.
(105 mm)
3.78 in.
(96 mm)
1.9 in.
(48 mm)
2.25 in.
(57 mm)
1.75 in.
(45 mm)
Resolution and accuracy 0-5V input resolution 1 mV, accuracy @ ±2 mV.
4-20mA input resolution 0.01mA, accuracy
@ ±0.02mA. J, K, E, N, T thermocouple input,
±0.05 percent or ±2°C, whichever is greater.
R,S thermocouple input, ±0.5 percent or ±3°C,
whichever is greater. 4-20mA output
resolution 0.014mA accuracy @ ±0.02mA.
J, K, E, N, T thermocouple output, ±0.05
percent or ±2°C, whichever is greater.
R,S thermocouple output, ±0.5 percent or
±4°C, whichever is greater.
Repeatability ±0.5% of measured value
Response time (95 percent) 500mSec
Warmup time 5 seconds
Signal Processing Peak hold, valley hold (up to 998 sec,
999=infinite hold with external reset).
Variable averaging filter (up to 60 seconds)
Measurement Specifications
Inputs User-configurable inputs for 0-5 V or 4-20mA
or J, K, E, N, R, S thermocouple. External
reset input to reset peak/valley hold circuit.
Outputs selectable 4-digit, 7 segment LED display, °C/°F.
User-configurable 4-20mA current or
thermocouple output (J, K, E, N, R, S, T).
Two adjustable set points with deadbands
controlling +5V alarm outputs or optional
3A mechanical relays. 24VÎ(dc)/50mA excitation
voltage for powering external sensors
Power supply 110/220VÅ(ac), ±20 percent, 50-60Hz
Electrical Specifications
Environmental rating GP front panel IP54 (IEC 529); NEMA-12
Ambient temperature range 0 to 50°C (32 to 120°F)
Storage temperature -30 to 65°C (-22 to 150°F)
GP monitor dimensions 1.75 X 3.63 X 4.75 in. (18DIN X 120 mm)
GP monitor weight 0.7 lbs (320 g)
General Specifications
124
Infrared Sensors
Fixed Mount
Raytek®MI™ Temperature
Measurement System
The MI™ product is a two-piece
infrared temperature measurement
system with miniature sensing head
and separate electronics. The
sensor is small enough to be
installed just about anywhere, yet
performs as well as much larger
systems. The MI™ electronics
include a host of signal processing
features which you won’t normally
find in systems in this price range,
including emissivity, peak hold,
valley hold and averaging, all of
which are adjustable on the five-digit
LCD interface.
Designed for applications where the
target temperature is in the -40 to
600°C (-40 to 1112°F) range, the
sensor is housed in a rugged
stainless steel enclosure to ensure
long term performance, even in
harsh industrial environments with
ambient temperatures up to 85°C
(185°F) without cooling.
Although the MI™ system is small in
size, it still has the features you
need, with one percent accuracy
and 10:1 optics, with user selectable
output signals. And the MI’s™
response time is as fast or faster
than many high-end systems.
The MI’s™ system’s miniature size
and low cost make it ideal for
installation at multiple points along
your process. Accurate. Easy to
install. Affordable. With the MI™
system, precision infrared
temperature measurement is now an
economical alternative.
Highlights
Small sensing head fits where
other sensors cannot
Ambient operating range to 85°C
(185°F) without cooling
Five-digit backlit LCD interface
Adjustable emissivity, peak hold,
valley hold and averaging
One percent accuracy from -40 to
600°C (-40 to 1112°F)
10:1 optics
Powered by 12-24VÎ(dc) at 100
mA
Accessories for cooling and air
purging
Remote electronics box
User selectable output signals
Optional RS232 or RS485
communication
W A T L O W
125
Infrared Sensors
Infrared Sensors
Fixed Mount
Raytek®MI™ Sensor
Nominal Optical Specifications
General Specifications
D:S is the optical resolution expressed as a
ratio of the distance to the resolution spot
divided by the diameter of the spot.
Optical resolution for the MID is 2:1 and 10:1.
Nominal spot size based on 90 percent
energy.
3.2
(80)
2.4
(60)
1.0
(25)
in. (mm)
Sensing Head
Electronics Housing
Accessories/Options*
Each standard MID package
includes a sensing head, one
mounting nut, 3.2 ft (1 m) of cable,
die-cast housing with premounted
electronics, and an operator’s
manual.
Adjustable or fixed mounting
bracket
Air purge jacket
Air cooling/purging system
Longer cable: 9.8 ft (3 m)*
RS232 or RS485 communication*
*Must be specified at time of order
Temperature range -40 to 600°C (-40 to 1112°F); -25 to 600°C
for J thermocouple output
Accuracy ±1% of reading or ±1°C (±2°F), whichever is
greater @ 23°C ±5°C (73°F ±9°F).
Thermocouple output accuracy ±1% of
reading or ±2.5°C, whichever is greater
@ 23°C ±5°C (73°F ±9°F)
Spectral response 8 to 14 microns
Optical resolution 10:1
Repeatability ±0.5% of reading or
±0.5°C (1°F), whichever is greater
Temperature coefficient 0.15K per K or 0.15% per K, whichever is greater
Temperature resolution 0.3°C (0.5°F)
Response time 150ms (95%)
Emissivity 0.100 to 1.100 digitally adjustable
increments of 0.001
Transmission 0.100 to 1.100 digitally adjustable
increments of 0.001
Signal processing Peak hold, valley hold, variable averaging filter,
adjustable up to 998 seconds
Measurement Specifications
Outputs Scalable 4-20mA, 0-20mA, 0-5V, J or K
thermocouple, 10mV/°C head ambient signal
Cable length 3.2 ft (1 m) standard, 9.8 ft (3 m) optional
Output impedance (T/C output) 20 ohm
Minimum lead impedance
(mV output) 100K ohms
Maximum loop impedance
(mA output) 500 ohms with 24VÎ(dc) power supply
Current draw 100mA
Power supply 11-26VÎ(dc)
Electrical Specifications
Environmental rating NEMA-4 (IP 65)
Ambient temperature range
Sensing head 0 to 85°C (32 to 185°F)
With air cooling -18 to 200°C (0 to 392°F)
Electronics housing 0 to 65°C (32 to 150)
Storage temperature -18 to 85°C (0 to 185°F)
Relative humidity 10 to 95% non-condensing
Construction
Sensing head Stainless steel
Electronics housing Zinc, die-cast
Weight
Sensing head (w/1 m cable) 1.75 oz (50 g)
Electronics housing 9.5 oz (270 g)
General Specifications
0.67 (17)
1.1 (28)
M 12x1
Ø 0.55 (14)
0.43 (11)
Preinstalled Cable
Standard Cable Length 3 ft (1 m)
Ø 0.2 (5)
in. (mm)
126
Infrared Sensors
Fixed Mount
Raytek®CI™ Sensor
The CI™ sensor provides the
advantages of infrared temperature
measurement in a compact, low cost
integrated sensor. Designed for easy
integration into a standard four-wire
system, the CI™ sensor can easily
replace traditional contact probes
with a Type J or Type K
thermocouple output, or with a 0-5
volt output if your application is
susceptible to noise or requires a
longer cable run.
The CI™ sensor is designed to
measure target temperatures ranging
from 0 to 500°C (32 to 932°F). The
CI’s™ onboard electronics are
protected by a rugged IP 65 (NEMA-
4) stainless steel housing and the
sensor can function in ambient
temperatures to 70°C (160°F) without
cooling. With water cooling, the CI™
sensor can withstand ambient
temperatures to 260°C (500°F).
Because the CI™ sensor has the
same 50 ohm output impedance as a
thermocouple, it functions
accurately—without offset errors—
when used in conjunction with the
thermocouple break protection
circuitry in most controllers, displays,
and transmitters.
Compact. Easy to install. Affordable.
The CI™ sensor is ideal for both
OEM and end-user applications.
Highlights
Type J or K, or 0-5V output
Two models cover temperature
ranges from 0 to 500°C (32 to
932°F)
IP 65 (NEMA-4) stainless steel
electronics housing
4:1 optics at 90 percent energy
350 mSec (95 percent) response
time
Powered by 12-24VÎ(dc) at
20mA
Accessories for cooling and air
purging
Output Type J Type K 10 mV/°C linear
thermocouple thermocouple voltage, scaled
0-5V (0-500°C)
Range A 0 to 350°C (32 to 662°F)
Range B 30 to 500°C (86 to 932°F)
Accuracy ±2% or ±3°C (±6°F), whichever is greater, btw 0 to
115°C (32 to 240°F); ±5% or ±6°C (±10°F),
whichever is greater, btw 30 to 100°C (86 to 212°F)
W A T L O W
127
Infrared Sensors
Infrared Sensors
Fixed Mount
Raytek®CI™ Sensor
D:S is the optical resolution expressed as a
ratio of the distance to the resolution spot
divided by the diameter of the spot.
Optical resolution for the CI™ is 4:1.
Nominal spot size based on 90 percent energy
Nominal Optical Specifications
General Dimensions
in. (mm)
3.5
(89)
2.48
(63)0.27
(7)
0.75
(19)
Ø0.67
(17) 0.75 in. - 16 UNF 2A
Ø0.75
(19)
Ø0.56
(14)
3 ft (1 m)
PVC Cable
Ø0.17 (4)
3 ft (1 m) Cable
Standard
Maximum
Ambient Temp
105°C (220°F)
Accessories/Options*
Sensing head comes with a
3 ft (0.9 m) cable, two mounting
nuts, and an operator’s manual.
GP monitor provides display, and
4-20mA output
Air-/water-cooled housing*
High temperature cables
(standard with air-/water-cooled
housing)
Adjustable or fixed mounting
bracket
Air purge collar
Longer cables 10 ft (3 m)*
*Must be specified at time of order
Spectral response 7 to 18 microns
System repeatability ±1% of measured value or
±1°C (2°F), whichever is greater
Temperature resolution <0.5°C (1°F)
Response time (95%) 350mSec
Emissivity Fixed at 0.95
Measurement Specifications
Outputs User-selectable thermocouple output (model
specific, either J or K) or voltage output 10mV/°C
head ambient signal
Cable length 3 ft (0.9 m) standard, longer cables optional
Output impedance 50 ohm
Minimum lead impedance 50K ohms
Power supply 12-24VÎ(dc) (£2.5% ripple) @ 20mA
Electrical Specifications
Environmental rating NEMA-4 (IP 65)
Ambient temperature range
Sensing head 0 to 70°C (32 to 160°F)
With air cooling 0 to 90°C (32 to 200°F)
With water cooling 0 to 260°C (32 to 500°F)
Storage temperature -30 to 85°C (-22 to 185°F)
Relative humidity 10 to 95% non-condensing
Shock IEC 68-2-27 (MIL STD 810D)
50 g’s, 11 mSec, any axis
Vibration IEC 68-2-27 (MIL STD 810D)
3 g’s, any axis, 11-200Hz
Dimensions 3.4 L in. X 0.75 in. D (19 mm L X 87 mm D)
Weight 4.5 oz (130 g)
General Specifications
Models and Temperature Ranges
Models CI1 CI2 CI3
Notes