© Coilcraft, Inc. 2005
Specifications subject to change without notice.
Please check our website for latest information.
Mini Spring™ Air Core Inductors
Document 107-1
Document 107-1 Revised 01/30/03
Test SRF5DCR6
Part Inductance2Percent Q4freq. min max Irms7Weight
number1Turns (nH) tolerance3min (MHz) (GHz) (mOhm) (A) (mg)
A01T_ 1 2.5 10 145 150 12.5 1.1 4 31
A02T_ 2 5.0 10,5,2 140 150 6.5 1.8 4 42
A03T_ 3 8.0 5,2 140 150 5.0 2.6 4 52
A04T_ 4 12.5 5,2 137 150 3.3 3.4 4 65
A05T_ 5 18.5 5,2 132 150 2.5 3.9 4 78
B06T_ 6 17.5 5,2 100 150 2.2 4.5 4 100
B07T_ 7 22.0 5,2 102 150 2.1 5.2 4 110
B08T_ 8 28.0 5,2 105 150 1.8 6.0 4 118
B09T_ 9 35.5 5,2 112 150 1.5 6.8 4 133
B10T_ 10 43.0 5,2 106 150 1.2 7.9 4 147
These surface mount air core “spring” inductors provide
extremely high Q over a wide frequency range.
They’re jacketed with a high temperature material that
ensures mechanical stability and very tight tolerance. It
also forms a flat top, making them suitable for automatic
placement and reflow or vapor phase processing. Solder
coated leads ensure reliable soldering.
Coilcraft Mini Spring™ inductors are available in standard
EIA tape and reel packaging: 12 mm for size A, and
16 mm for size B parts.
Coilcraft Designer’s Kit C102 contains samples of all
5% inductance tolerance parts. Kits with 2% tolerance
are also available. To order, contact Coilcraft or visit
http://order.coilcraft.com.
1. When ordering, please specify tolerance code:
A02TG
Tolerance: G =2% J = 5% K = 10%
2. Inductance measured using Agilent/HP 4286 with Coilcraft SMD-A fixture and correlation.
3. Tolerances in bold are stocked for immediate shipment.
4. Q measured using Agilent/HP 4291A with Agilent/HP 16193A test fixture.
5. SRF tested on the Agilent/HP 8720D and the SMD-D test fixture.
6. DCR tested on the Cambridge Technology Model 510 Micro-ohmmeter.
7. Average current for a 15°C rise above 25°C ambient.
8. Operating temperature range -40°C to +125°C.
9. Electrical specifications at 25°C.
See Qualification Standards section for environmental and test data