MINI-BEAM®
SM2A312CV and SM2A312CV2
Self-contained AC-operated Convergent Mode Sensors
Printed in USA P/N 03402L7H
• Compact, modulated, self-contained convergent mode
sensors for 24-240V ac operation
Produces a precise 1.3 mm (0.05 in) diameter sensing spot
at a focus point 16 mm (0.65 in) from the lens surface
(model SM2A312CV) or a 3.0 mm (0.12 in) sensing spot at
43 mm (1.70 in) focus (model SM2A312CV2)
Switch-selectable for light operate or dark operate
SPST SCR solid-state output switches up to 300mA; low
leakage current and saturation voltage
Rugged, epoxy-encapsulated construction: meets NEMA
standards 1, 2, 3, 3S, 4, 4X, 12 and 13; IEC IP67
Physically and electrically interchangeable with 18 mm
barrel-type photoelectrics
MINI-BEAM Convergent Mode
37.5 mm
1.5 in
30 mm
1.2 in
22.5 mm
0.9 in
15 mm
0.6 in
7.5 mm
0.3 in
0
0
1.0 mm
2.0 mm
3.0 mm
1.0 mm
2.0 mm
3.0 mm
0
0.04 in
0.08 in
0.12 in
0.04 in
0.08 in
0.12 in
DISTANCE
SM2A312CV
Convergent Mode
Models Range Cable Supply
Voltage Output
Type Excess Gain Beam Pattern
SM2A312CV
SM2A312CVQD
16 mm
(0.65 in)
Spot
Size
at Focus:
1.3 mm
(0.05 in)
2 m (6.5 ft)
3-Pin Micro QD 24-240V ac SPST
Solid-state
2-Wire
1
10
100
10 mm
.4 in 100 mm
4 in 1000 mm
40 in
1 mm
.04 in
1000
E
X
C
E
S
S
G
A
I
N
DISTANCE
Convergent Mode
SM2A312CV
Performance based on 90% reflectance white test card
Visible red, 650 nm
125 mm
5 in
100 mm
4 in
75 mm
3 in
50 mm
2 in
25 mm
1 in
0
0
1.0 mm
2.0 mm
3.0 mm
1.0 mm
2.0 mm
3.0 mm
0
0.04 in
0.08 in
0.12 in
0.04 in
0.08 in
0.12 in
DISTANCE
SM2A312CV2
Convergent Mode
SM2A312CV2
SM2A312CV2QD
43 mm
(1.7 in)
Spot
Size
at Focus:
3.0 mm
(0.12 in)
2 m (6.5 ft)
3-Pin Micro QD 24-240V ac SPST
Solid-state
2-Wire
1
10
100
10 mm
.4 in 100 mm
4 in 1000 mm
40 in
1 mm
.04 in
1000
E
X
C
E
S
S
G
A
I
N
DISTANCE
SM2A312CV2
Convergent Mode
For Standard MINI-BEAMs:
i) 9 m (30 ft) cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g. - SM2A312CV W/30).
ii) A 150 mm (6 in.) long pigtail cable with attached QD connector is available by adding suffix “QDP” to the model number of any
MINI-BEAM sensor (e.g. - SM2A312CVQDP). See page 5 for more information.
iii) A model with a QD connector requires an accessory mating cable. See page 5 for more information.
MINI-BEAM®Sensors
SM2A312CV and SM2A312CV2
page 2
MINI-BEAM Installation and Alignment
Proper operation of the SM2A312CV or SM2A312CV2 sensor requires that
it be mounted securely and aligned properly. In some applications,
excessive movement or vibration can result in intermittent or false
operation caused by loss of alignment. For best results, final-mount the
sensor in an 18mm-hole by its threaded barrel or use a mounting bracket
(see page 6).
Begin with the sensor at the approximate position where it will be
mounted. With power applied to the circuit and with the sensor set for
“light operate”, direct the sensor’s visible red spot at the object
approximately 16 mm (0.65 in) (for model SM2A312CV) or 43 mm (1.7
in) (for model SM2A312CV2) directly in front of the lens. Move the sensor
very slightly toward or away from the object while observing the red LED
indicator on the back of the sensor. Note the near and far points at which
sensing occurs (the range of distance over which the LED remains lit).
Mount the sensor at a point approximately midway in the range. This
should correspond to the point at which the red sensing spot on the object
appears most sharply defined. Mount the sensor at this position and
distance.
15 Turn
Gain
Adjustment
and Light/Dark
Operate Switch*
Gasketed
Acrylic Cover
Red LED lights when the
sensor's output is conducting
Low Reflectivity Background
Up
Down
Left Right
SM2A312CV
or
SM2A312CV2
Object
*Note regarding Light/Dark operate switch:
• Turn switch
fully
clockwise for light operate (sensor outputs conduct when object is present)
• Turn switch
fully
counterclockwise for dark operate (sensor outputs conduct when object is absent)
Distance from Sensor lens to object:
16 mm (0.65 in) for SM2A312CV
43 mm (1.7 in) for SM2A312CV2
CONVERGENT MODE ALIGNMENT
SM2A312CV OR CV2
page 3
MINI-BEAM®Sensors
SM2A312CV and SM2A312CV2
VALOX®is a registered trademark of General Electric Company
MINI-BEAM AC Product Specifications
Certifications
Supply Voltage and Current 24 to 240V ac (50/60 Hz), 250V ac max
Supply Protection Circuitry Protected against transient voltages
Output Configuration SPST SCR solid-state relay with either normally closed or normally open contact (light/dark operate
selectable); 2-wire hookup
Output Rating Minimum load current 5 mA; maximum steady-state load capability 300 mA to 50°C ambient (122°F)
100 mA to 70°C ambient (158°F)
Inrush capability 3 amps for 1 second (non-repetitive); 10 amps for 1 cycle (non-repetitive)
Off-state leakage current less than 1.7 mA rms
On-state voltage drop 5 volts at 300 mA load, 10 volts at 15 mA load
Output Protection Circuitry Protected against false pulse on power-up
Output Response Time 4 milliseconds on and off
“OFF” response time specification does not include load response of up to 1/2ac cycle (8.3 milliseconds).
Response time specification of load should be considered when important.
(NOTE: 300 millisecond delay on power-up.)
Repeatability 1.3 milliseconds; Response time and repeatability specifications are independent of signal strength.
Adjustments LIGHT/DARK OPERATE select switch, and 15-turn slotted brass screw GAIN (sensitivity) adjustment po-
tentiometer (clutched at both ends of travel). Both controls are located on rear panel of sensor and
protected by a gasketed, clear acrylic cover.
Indicators Red indicator LED on rear of sensor is “ON” when the load is energized
Construction Reinforced VALOX®housing, totally encapsulated, o-ring sealing, acrylic lenses, and stainless steel screws
Environmental Rating Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12, and 13; IEC IP67
Connections PVC-jacketed 2-conductor 2 m (6.5ft) or 9 m (30ft) cables, or 3-pin micro-style quick disconnect (QD)
fitting are available. QD cables are ordered separately. See page 5.
Operating Temperature Temperature: -20° to +70°C (-4° to +158°F)
Maximum Relative Humidity: 90% at 50°C (non-condensing)
Application Notes i) ac MINI-BEAMs may be destroyed from overload conditions
ii) Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state
voltage of the sensor will interfere with proper operation of the load
iii) The false-pulse protection feature may cause momentary drop-out of the load when the sensor is
wired in series or parallel with mechanical switch contacts
MINI-BEAM®Sensors
SM2A312CV and SM2A312CV2
page 4
MINI-BEAM Dimension Information
MINI-BEAM AC Sensor with Integral Cable MINI-BEAM AC Sensor with Quick-Disconnect
MINI-BEAM AC Hookup Diagrams
AC Sensors with Attached Cable AC Sensors with Quick Disconnect
(3-Pin Micro-Style)
bn
bu Load
24-240V ac
rd/bk
gn
rd/wh Load 24-240V ac
Quick Disconnect (QD) Option
AC MINI-BEAM sensors are sold with either a 2 m (6.5 ft)
or a 9 m (30 ft) attached PVC-covered cable, or with a 3-pin
micro-style QD cable fitting.
AC QD sensors are identified by the letters “QD” in their
model number suffix. For more information on mating QD
cables, see page 5.
3-Pin Micro-Style Pin-out
(Cable Connector Shown)
Green Wire
Red/Black
Wire
Red/White
Wire
12.2 mm (0.48 in)
Mounting Peg
(ø 6.3 mm x 2.5 mm)
ø 3 mm Clearance (2)
M18 x 1 x 15 mm Thread
(Mounting Nut Supplied)
3.2 mm
(0.13 in)
27.4 mm (1.08 in)
30.7 mm
(1.21 in)
24.1 mm
(0.95 in)
19.1 mm
(0.75 in)
66.0 mm
(2.60 in)
2 m (6.5 ft) Cable
1/2-20 UNF Thread
Quick Disconnect
20.0 mm
(0.79 in)
page 5
MINI-BEAM®Sensors
SM2A312CV and SM2A312CV2
MINI-BEAM MODIFICATIONS
Description
All MINI-BEAM sensors may be ordered with an integral 9 m (30 ft)
cable in place of the standard 2 m (6.5 ft) cable
Model Suffix Modification Example of Model
Number
W/30 9 meter (30 ft) cable SM2A312CV W/30
All MINI-BEAMs may be built
with a 150 mm (6 in) long
integral cable which is
terminated with the
appropriate QD connector.
QDP Pigtail Quick
Disconnect SM2A312CVQDP
Replacement Lens Assemblies
MINI-BEAM lens assemblies are field-replaceable.
Model Description
UC-300C.7
UC-300C2
Replacement lens for CV
Replacement lens for CV2
Micro-Style Quick Disconnect Cables
38 mm max.
(1.5 in)
1/2-20UNF-2B
ø15 mm
(0.6 in)
38 mm max.
(1.5 in)
Cable: PVC jacket, polyurethane connector body, nickel-plated brass coupling nut
Conductors: 22 or 20 AWG high-flex stranded, PVC insulation, gold-plated contacts
Temperature: -40 to +80°C (-40 to +176°F)
Voltage Rating: 250V ac/300V dc (3-pin), 125V ac/150V dc (4-pin)
3-Pin
Straight
MQDC-306
MQDC-315
MQDC-330
2 m (6.5 ft)
5 m (15 ft)
9 m (30 ft)
ø1/2-20UNF-2B
ø15 mm
(0.6 in)
44 mm max.
(1.7 in)
Style
3-Pin
Right-angle
MQDC-306RA
MQDC-315RA
MQDC-330RA
2 m (6.5 ft)
5 m (15 ft)
9 m (30 ft)
Green Wire
Red/Black
Wire
Red/White
Wire
Model Length Dimensions Pin-out
MINI-BEAM®Sensors
SM2A312CV and SM2A312CV2
page 6
Mounting Brackets
SMB46L
SMB312PD Stainless steel 18 mm barrel-
mounting bracket
Model Description
• “L” bracket
• 14 ga 316 stainless steel
C
L
8 mm
(0.3 in) 16 mm
(0.6 in)
65 mm
(2.6 in)
27 mm
(1.1 in)
2 mm
(.1 in)
6 mm
(0.2 in)
5 mm (0.2 in)
(2x)
ø36 mm (1.4 in)
ø6.5 mm (0.26 in) (6x)
15 mm
(0.6 in)
6 mm
(0.2 in)
54 mm
(2.1 in)
SMB312S Stainless steel 2-axis, side
mounting bracket
R 5.1 mm
(0.20 in)
ø 4.6 mm
(0.18 in)
ø 4.6 mm Slot
(0.18 in)
20°
90°
C
L
15°
(2)
R 24.1 mm
(0.95 in)
31.8 mm
(1.25 in)
40.6 mm
(1.60 in)
45.5 mm
(1.79 in)
18.42 mm
(0.725 in)
R 3.1 mm
(0.12 in) (2)
15.2 mm
(0.60 in)
2.5 mm
(0.10 in)
SMB312B Stainless steel 2-axis, bottom
mounting bracket
Includes SMB12F (below)
90°
10° (2)
10° (2)
2.5 mm
(0.10 in) 3.1 mm
Slot (2)
(0.12 in)
4.3 mm Slot (2)
(0.17 in)
8.6 mm (2)
(0.34 in)
ø 6.9 mm
(0.27 in)
17.3 mm (2)
(0.68 in)
35.0 mm (2)
(1.38 in)
50.8 mm
(2.00 in)
23.4 mm
(0.92 in)
11.4 mm
(0.45 in)
9.1 mm
(0.36 in)
24.1 mm
(0.95 in)
EC312A-100 2-conductor All MINI-BEAM SM2A312 ac models
The following cables are available for extending the length of existing sensor cable. These are 30 m (100 ft) lengths of MINI-BEAM cable.
This cable may be spliced to existing cable. Connectors, if used, must be customer-supplied.
Model Type Used with:
Extension Cables (without connectors)
page 7
MINI-BEAM®Sensors
SM2A312CV and SM2A312CV2
Mounting Brackets
54 mm
(2.1 in)
C
L
8 mm
(0.3 in) 16 mm
(0.6 in)
17 mm
(0.7 in)
34 mm
(1.3 in)
65 mm
(2.6 in)
27 mm
(1.1 in) 16 mm
(0.6 in)
2 mm
(.1 in)
6 mm
(0.2 in)
10 mm
(0.4 in)
5 mm (0.2 in)
(4x)
ø36 mm (1.4 in)
ø6.5 mm (0.26 in) (6x)
3.5 mm
(0.14 in)
15 mm
(0.6 in)
6 mm
(0.2 in)
65 mm
(2.6 in)
27 mm
(1.1 in)
2 mm
(.1 in)
16 mm
(0.6 in)
70 mm
(2.8 in)
54 mm
(2.1 in)
C
L
8 mm
(0.3 in) 16 mm
(0.6 in)
17 mm
(0.7 in)
34 mm
(1.3 in)
6 mm
(0.2 in)
13 mm
(0.5 in)
5 mm (0.2 in)
(4x)
ø36 mm (1.4 in)
ø6.5 mm (0.26 in) (6x)
3.5 mm
(0.14 in)
15 mm
(0.6 in)
6 mm
(0.2 in)
SMB46S
Model Description Dimensions
SMB46U
• “S” bracket
• 14 ga 316 stainless steel
40.0 mm
(1.60 in)
42.4 mm
(1.67 in)
30.0 mm
(1.18 in)
2.5 mm
(0.10 in)
21.1 mm
(0.83 in)
Nut Plate
M5 x 0.8
x 60 mm
Screw (2)
13 mm
(0.5 in)
14.0 mm
(0.55 in)
• “U” bracket
• 14 ga 316 stainless steel
SMB18C
• 18 mm split clamp black
VALOX®bracket
• Stainless steel mounting
hardware included
46.0 mm
(1.81 in)
44.5 mm
(1.75 in)
36.0 mm
(1.42 in)
2.5 mm
(0.10 in)
25.4 mm
(1.00 in)
13.0 mm (0.50 in) Nut Plate
Spacer
(If Required)
M5 x 0.8
x 60 mm
Screw (2)
6.4 mm
(0.25 in)
10.9 mm
(0.43 in)
SMB18S
• 18 mm swivel, black VALOX®
bracket
• Stainless steel mounting
hardware included
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications) (612) 544-3573
MINI-BEAM®Sensors
SM2A312CV and SM2A312CV2
WARNING These photoelectric presence sensors do NOT include the self-checking redundant circuitry
necessary to allow their use in personnel safety applications. A sensor failure or malfunction can result in either
an energized or a de-energized sensor output condition.
Never use these products as sensing devices for personnel protection. Their use as a safety device may create
an unsafe condition which could lead to serious injury or death.
Only MINI-SCREEN®, MULTI-SCREEN®, MICRO-SCREEN, MACHINE-GUARDand PERIMETER-GUARDSystems, and other
systems so designated, are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding
devices. No other Banner sensors or controls are designed to meet these standards, and they must NOT be used as sensing
devices for personnel protection.
!
WARRANTY: Banner Engineering Corporation warrants it products to be free from defects for one year. Banner Engineering
Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned
to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of
Banner products. This warranty is in lieu of any other warranty either expressed or implied.