1N5817 - 1N5819
Current
1.0 A
Voltage
20 V to 40 V
MECHANICAL DATA
Low power losses, high efficiency
1.0 Amp. Schottky Barrier Rectifier
TYPICAL APPLICATIONS
Used in low voltage high frequency inverters, freewheeling,
dc-to-dc converters, and polarity protection applications.
FEATURES
High surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
Guarding for overvoltage protection
Low forward voltage drop
DO-204AL / DO-41
High frequency operation
Maximum Ratings and Electrical Characteristics at 25 ºC
V
RRM
Maximum Recurrent Peak Reverse Voltage (V)
Maximum RMS Voltage (V)
I
FSM
8.3 ms.Peak Forward Surge Current
V
DC
Maximum DC Blocking Voltage (V)
30 A
V
RMS
T
j
Operating Temperature Range -65 to +125 °C
(Jedec Method)
20
20
14
1N5817
30
30
21
1N5818
40
40
28
1N5819
Typical Thermal Resistance
I
F(AV)
Maximum Average Forward Rectified Current
1.0 A
100 °C/W
R
th (j-a)
T
stg
Storage Temperature Range
-65 to +150 °C
Electrical Characteristics at Tamb = 25 °C
0.550 V
V
F
Maximum Instantaneous Forward Voltage I
F
= 1.0 A
0.45 V
0.600 V
I
R
Maximum DC Reverse Current Tj = 25 °C
at Rated DC Blocking Voltage Tj =125°C
1.0 mA
10 mA
C
j
Typical Junction Capacitance
55 pF
(Note 2)
(Note 1)
9.5mm Lead Lenght @ Tc = 90°C (See graphic)
0.875 V
V
F
Maximum Instantaneous Forward Voltage I
F
= 3.0 A
0.750 V
0.900 V
R
th (j-c)
45 °C/W
(Note 1)
(Note 3)
www.fagorelectronica.com
Document Name: 1n5810 Version: Oct-11
Page Number: 1/4

Case: DO-204AL / DO-41. Epoxy meets UL 94V-0
flammability rating.

Polatity: Color band denotes cathode end.

Terminals:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test
Notes: 1. Pulse Test: 300µ Pulse Width, 1% Duty Cycle
2. Thermal Resistance from Junction to Case per diode
3. Pulse test: Pulse width £ 40ms
Package Outline Dimensions
:
(mm)
1N5817 - 1N5819
1.0 Amp. Schottky Barrier Rectifier
Ordering information
AMP
DO-204AL / DO-41
1N5819 AMP
TR
1N5819 TR 13" diameter tape and reel 5,000 0.325
AMMO BOX 3,000 0.325
AMP
1N5819 HF AMP AMMO BOX 3,000 0.325
TR
1N5819 HF TR 13" diameter tape and reel 5,000 0.325
ø0.8
±0.05
58.5
±0.5
5
+0.2
0
ø2.6
±0.1
www.fagorelectronica.com
Document Name: 1n5810 Version: Oct-11
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
1N5817 - 1N5819
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
1.0 Amp. Schottky Barrier Rectifier
Transient thermal impedance (°C/W)
TYPICAL TRANSIENT THERMAL IMPEDANCE
T, Pulse duration (sec)
0.1
100
0.01
1
10
0.1 1 10 100
www.fagorelectronica.com
Document Name: 1n5810 Version: Oct-11
Page Number: 3/4
0.1
I
F
, instantaneous forward current (A)
1
VF
, forward voltage (V)
0.1 0.5 0.9 1.3 1.7
TYPICAL FORWARD CHARACTERISTIC
20
Lead temperature (°C)
0
I
F(AV)
, average forward Current (A)
100
100
MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
30
10
0
10
1
I
FSM
, peak forward surge current (A)
400
10
100.1
Cj, junction capacitance (pF)
Percent of rated peak reverse voltage (%)
IR, Instantaneous Reverse current (mA)
0
1
0
0.50
1
0.1
00.1
100
100
15
20
0.3 0.7 1.1 1.5
25 75 150
TYPICAL REVERSE LEAKAGE
CHARACTERISTICS PER LEG
MAXIMUM FORWARD CURRENT DERATING
CURVE
20 40 60 80
Number of cycles at 60 Hz
100
TYPICAL JUNCTION CAPACITANCE
10
25
V
R
, reverse voltage (V)
10
100
17550
1.0
125
0.75
0.25
1.9 2.1
200
80
60
40
20
5
20
250
5
8.3ms Single Half Sine Wave
JEDEC Method
400.4 4
1N5817
1N5818, 1N5819
T
j
= 125 °C
T
j
= 25 °C
PULSE WIDTH = 300 µs
1% DUTY CYCLE
Tj = 25 °C
1N5817 - 1N5819
Disclaimer
1.0 Amp. Schottky Barrier Rectifier
www.fagorelectronica.com
Document Name: 1n5810 Version: Oct-11
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.