General-purpose Limit Switch D4A-@N The Limit Switch with Better Seal, Shock Resistance, and Strength * A double seal on the head, a complete gasket cover, and other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13). * Block mounting method to reduce weight to 290 g. * Block mounting method also reduces downtime for maintenance. * Wide standard operating temperature range: -40C to 100C (standard type). * Models with fluoro-rubber available for greater resistance to chemicals. * DPDT, double-break models available for complex operations. * Approved by UL, CSA, and CCC (Chinese standard). Model Number Structure Model Number Legend D4A-@@@@N 1 2 3 1. Receptacle Box 1: 1/2-14 NPT conduit (SPDT, double-break) 2: 1/2-14 NPT conduit (DPDT, double-break) 3: G 1/2 conduit (SPDT, double-break) 4: G 1/2 conduit (DPDT, double-break) 2. Switch Box 1: SPDT, double-break, without indicator 3: SPDT, double-break, neon lamp E: SPDT, double-break, LED (24 VDC, leakage current: 1.3 mA) 5: DPDT, double-break, simultaneous operation, without indicator 7: DPDT, double-break, sequential operation, without indicator (See note 1.) 9: DPDT, double-break, center neutral operation, without indicator (See note 2.) L: DPDT, double-break, simultaneous operation, neon lamp P: DPDT, double-break, simultaneous operation, LED 3. Head 01: 02: 03: 04: 05: 17: 18: 06: 07-V: 07-H: 08: 09: 10: 11: 12: 14: 15: 16: Roller lever, standard Roller lever, high-sensitivity Roller lever, low torque Roller lever, high-sensitivity, low torque Roller lever, maintained Roller lever, sequential operation Roller lever, center neutral operation Side plunger, standard Side plunger, vertical roller Side plunger, horizontal roller Side plunger, adjustable Top plunger, standard Top plunger, roller Top plunger, adjustable Flexible rod, spring wire Flexible rod, plastic rod Flexible rod, cat whisker Flexible rod, coil spring Note: 1. Use the D4A-0017N Special Head. 2. Use the D4A-0018N Special Head. 3. Fluoro-rubber sealed type is also available. 74 General-purpose Limit Switch D4A-@N Ordering Information List of Models SPDT, Double-break Switches Receptacle box Indicator Actuator Roller lever (See note 1.) Side plunger Top plunger Flexible rod G 1/2 Conduit Without indicator Model With neon lamp indicator (AC) Approved standards Model With LED indicator (DC) Approved standards Model Standard D4A-3101N UL, CSA D4A-3301N UL, CSA D4A-3E01N High-sensitivity D4A-3102N UL, CSA D4A-3302N UL, CSA D4A-3E02N Low-torque D4A-3103N UL, CSA --- UL, CSA --- High-sensitivity, Lowtorque D4A-3104N UL, CSA D4A-3304N UL, CSA --- Maintained (See note 2.) D4A-3105N UL, CSA D4A-3305N UL, CSA D4A-3E05N Standard D4A-3106N UL, CSA --- UL, CSA --- Vertical roller D4A-3107-VN UL, CSA D4A-3307-VN UL, CSA D4A-3E07-VN Horizontal roller D4A-3107-HN UL, CSA D4A-3307-HN UL, CSA --- Adjustable D4A-3108N UL, CSA D4A-3308N UL, CSA D4A-3E08N Standard D4A-3109N UL, CSA D4A-3309N UL, CSA --- Roller D4A-3110N UL, CSA D4A-3310N UL, CSA --- Adjustable D4A-3111N UL, CSA D4A-3311N UL, CSA --- Spring wire D4A-3112N UL, CSA D4A-3312N UL, CSA D4A-3E12N Plastic rod D4A-3114N UL, CSA D4A-3314N UL, CSA D4A-3E14N Cat whisker D4A-3115N UL, CSA D4A-3315N UL, CSA D4A-3E15N Coil spring D4A-3116N UL, CSA D4A-3316N UL, CSA D4A-3E16N Note: 1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on pages 92 and 93). 2. The Maintained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock. 3. Switches are also available with @1/2-14 NPT conduits. The model numbers correspond as follows: G 1/2 Conduits 1/2-14 NPT Conduits D4A-3@@@N D4A-1@@@N D4A-4@@@N D4A-2@@@N 4. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is -10 to 120C.) Add "-F" to the model number. (Example: D4A-3101N becomes D4A-3101N-F.) Ask your nearest OMRON representative for details. General-purpose Limit Switch D4A-@N 75 DPDT, Double-break Switches Receptacle box Indicator Actuator Roller lever (See note 1.) Side plunger Top plunger Flexible rod G 1/2 Conduit Without indicator Model With neon lamp indicator (AC) Approved standards Model With LED indicator (DC) Approved standards Model Standard D4A-4501N UL, CSA D4A-4L01N UL, CSA D4A-4P01N High-sensitivity D4A-4502N UL, CSA --- --- --- Low-torque D4A-4503N UL, CSA --- --- --- High-sensitivity, Lowtorque D4A-4504N UL, CSA --- --- --- Maintained (See note 2.) D4A-4505N UL, CSA --- --- --- Sequential operation D4A-4717N UL, CSA --- --- --- Center neutral operation D4A-4918N UL, CSA --- --- --- Standard D4A-4506N UL, CSA --- --- --- Vertical roller D4A-4507-VN UL, CSA --- --- --- Horizontal roller D4A-4507-HN UL, CSA --- --- --- Adjustable D4A-4508N UL, CSA --- --- --- Standard D4A-4509N UL, CSA --- --- --- Roller D4A-4510N UL, CSA D4A-4L10N UL, CSA D4A-4P10N Adjustable D4A-4511N UL, CSA --- --- --- Spring wire D4A-4512N UL, CSA --- --- --- Plastic rod D4A-4514N UL, CSA --- --- --- Cat whisker D4A-4515N UL, CSA --- --- --- Coil spring D4A-4516N UL, CSA --- --- --- Note: 1. The lever is not included with the Roller Level Models. Select the lever from those listed in this data sheet and order it separately (refer to Levers on pages 92 and 93). 2. The Maintained Switches have a lock mechanism for the switch operation and thus use a Fork Lever Lock. 3. Switches are also available with @1/2-14 NPT conduits. The model numbers correspond as follows: G 1/2 Conduits 1/2-14 NPT Conduits D4A-3@@@N D4A-1@@@N D4A-4@@@N D4A-2@@@N 4. Switches are also available with fluoro-rubber seals for higher resistance to chemicals. (The operating temperature range for these Switches, however, is -10 to 120C.) Add "-F" to the model number. (Example: D4A-4501N becomes D4A-4501N-F.) Ask your nearest OMRON representative about delivery times and prices. 76 General-purpose Limit Switch D4A-@N Individual Parts Replacement of Parts Because the D4A-@N employs block mounting construction, the switch box, receptacle, and operating head may be ordered as a complete assembly or individually as replacement parts. Receptacle Switch box Head Lever Levers for Roller Lever Switches are optionally available. Select the lever from those listed in this datasheet and order (refer to Levers on pages 92 and 93). D4A-1101N D4A-1000N D4A-0100N D4A-0001N Receptacle Box Type Appearance 1/2-14NPT conduit (See note 2.) Model G1/2 conduit (See note 1.) Approved standards Model Approved standards SPDT doublebreak D4A-1000N UL, CSA D4A-3000N UL, CSA DPDT doublebreak D4A-2000N UL, CSA D4A-4000N UL, CSA Note: 1. M6-screw mounting (standard mounting) 2. 10-32UNF-screw mounting (standard mounting) Switch Box Type Appearance Without indicator Model SPDT double-break With neon lamp indicator (AC) Approved standards Model With LED indicator (DC) Approved standards Model D4A-0100N UL, CSA D4A-0300N UL, CSA D4A-0E00N D4A-0500N UL, CSA D4A-0L00N --- D4A-0P00N Sequential oper- D4A-0700N ation UL, CSA --- --- --- Center neutral operation UL, CSA --- --- --- (Without indicator lamp) DPDT double-break Simultaneous operation (Without indicator lamp) D4A-0900N General-purpose Limit Switch D4A-@N 77 Heads Type Appearance Roller lever (See note 1.) Approved standards Standard: High-sensitivity: Low torque: Sequential operation: Center neutral operation: D4A-0001N D4A-0002N D4A-0003N (see note 2) D4A-0017N (see note 3) D4A-0018N (see note 3) UL, CSA Maintained: D4A-0005N UL, CSA Side plunger UL, CSA Standard: D4A-0006N Horizontal roller: D4A-0007-HN Vertical roller: D4A-0007-VN Side adjustable: D4A-0008N Top plunger UL, CSA Standard: D4A-0009N Roller plunger: D4A-0010N Plunger adjustable: D4A-0011N Flexible rod UL, CSA Spring wire D4A-0012N Plastic rod D4A-0014N Cat whisker D4A-0015N Coil spring D4A-0016N Note: 1. Levers for Roller Lever Switches are optionally available. Select the lever from those listed in this data sheet and order (refer to Levers on pages 92 and 93). 2. The D4A-C00 adjustable roller lever is too heavy and long for these heads and it should not be used or mechanical malfunction will result. 3. These heads cannot be used for double break operations. Levers Actuator type Roller Lever Model D4A-A00 D4A-A10 D4A-A20 D4A-A30 D4A-B06 Adjustable Roller Lever D4A-C00 Resin Loop Lever D4A-F00 Fork Lever Lock D4A-E30 D4A-D00 D4A-E20 D4A-E10 D4A-E00 Note: Refer to page 92 for Lever shapes and applicable models. 78 General-purpose Limit Switch D4A-@N Specifications Approved Standards Agency Standard UL UL508 File No. E76675 CSA CSA C22.2 No. 14 LR45746 CCC (CQC) GB14048.5 2003010305077615 Note: Ask your OMRON representative for information on approved models. Approved Standard Ratings UL/CSA A600 D4A-@1@@N (SPDT, Double-break, Without Indicator) Rated voltage Carry current Current Volt-amperes Make 10 A 120 VAC 240 VAC 480 VAC 600 VAC Break 7,200 VA 6A 3A 1.5 A 1.2 A 60 A 30 A 15 A 12 A Make Break 720 VA A300 D4A-@3@@N (SPDT, Double-break, With Neon Lamp) Rated voltage Carry current Current Volt-amperes Make 120 VAC 240 VAC 10 A 60 A 30 A Break 6A 3A Make 7,200 VA Break 720 VA B600 D4A-@5@@N (DPDT, Double-break, Simultaneous Operation) D4A-@7@@N (DPDT, Double-break, Sequential Operation) D4A-@9@@N (DPDT, Double-break, Center Neutral Operation) Rated voltage Carry current Current Volt-amperes Make 5A 120 VAC 240 VAC 480 VAC 600 VAC 30 A 15 A 7.5 A 6.0 A Break 3A 1.5 A 0.75 A 0.6 A Make 3,600 VA Break 360 VA CCC (GB14048.5) Applicable category and ratings AC-15 2 A/125 VAC General-purpose Limit Switch D4A-@N 79 General Ratings Type Rated voltage Non-inductive load Resistive load NC 125 VAC (See note 5.) SPDT double-break (with/without indicator) DPDT double-break (without indicator) DPDT double-break (with indicator) 10 A NO 10 A 3A NO 1.5 A NC Motor load NO NC NO 10 A 5A 2.5 A 10 A 10 A 2A 1A 10 A 3A 1.5 A 480 VAC 10 A 10 A 1.5 A 0.8 A 3A 1.5 A 0.8 A 600 VAC 3A 1A 1A 0.5 A 1.5 A 1A 0.5 A 8 VDC 10 A 6A 3A 10 A 6A 14 VDC 10 A 6A 3A 10 A 6A 30 VDC 6A 4A 3A 6A 4A 125 VDC (See note 5.) 0.8 A 0.2 A 0.2 A 0.8 A 0.2 A 250 VDC (See note 5.) 0.4 A 0.1 A 0.1 A 0.4 A 0.1 A 125 VAC 5A 2A 4A 3A 250 VAC 3A 1A 2A 1.5 A 480 VAC 1.5 A 0.5 A 1A 0.8 A 600 VAC 1A 0.4 A 0.7 A 0.5 A 14 VDC 5A 2A 4A 3A 30 VDC 3A 1A 2A 1.5 A 125 VDC 0.4 A 0.1 A 0.4 A 0.1 A 250 VDC 0.2 A 0.05 A 0.2 A 0.05 A 125 VAC 5A 2A 4A 3A 250 VAC 3A 1A 2A 1.5 A 12 VDC 5A --- --- --- 24 VDC 3A 48 VDC 1A --- SPDT, double-break Without indicator Note: 1. 2. 3. 4. 5. NC Inductive load 250 VAC (See note 5.) Type Inrush current Inductive load Lamp load Normally closed 30 A max. Normally open 20 A max. With indicator DPDT, double-break Without indicator With indicator The above current ratings are for steady-state current. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). Lamp loads have an inrush current of 10 times the steady-state current. Motor loads have an inrush current of 6 times the steady-state current. For those with indicators, refer to the following rated voltages. Ratings for Indicators Classification SPDT double-break DPDT double-break 80 Indicator Model Neon lamp D4A-0300N LED D4A-0E00N Rated voltage 125 VAC, 250 VAC Carry current Approx. 0.47 mA Internal resistance 150 k 12 VDC Approx. 3.2 mA 2.2 k 24 VDC Approx. 4 mA 4.7 k 24 VDC Approx. 1.3 mA 15 k 48 VDC Approx. 2 mA 22 k Neon lamp D4A-0L00N 125 VAC, 250 VAC Approx. 0.28 mA 240 k LED D4A-0P00N 48 VDC Approx. 1.4 mA --- General-purpose Limit Switch D4A-@N Characteristics Degree of protection IP67 Durability (See note 3.) Mechanical: SPDT, double-break, roller lever: 50,000,000 operations min. (See note 2.) DPDT, double-break, roller lever: 30,000,000 operations min. (See note 2.) Electrical: SPDT, double-break: for 125 VAC, 10 A resistive load: 1,000,000 operations min. DPDT, double-break: for 125 VAC, 5 A resistive load: 750,000 operations min. Operating speed 1 mm to 2 m/s (for D4A-3101N roller lever model) Operating frequency Mechanical: 300 operations/minute Electrical: 30 operations/minute Rated frequency 50/60 Hz Insulation resistance 100 M min. (at 500 VDC) between terminals of the same polarity, between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part Contact resistance 25 m max. (initial value) Temperature rise 50C max. Dielectric strength 1,000 VAC, 50/60 Hz for 1 min. between terminals of same polarity 2,200 VAC, 50/60 Hz for 1 min. between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part (See note 4.) Pollution degree (operating environment) 3 Protection against electric shock Class I (with grounding terminal) Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (See note 5.) Shock resistance Destruction: 1,000 m/s2 min. Malfunction: SPDT, double-break, roller lever: 600 m/s2 min. (See note 5.) DPDT, double-break, roller lever: 300 m/s2 min. (See note 5.) Ambient operating humidity 35% to 95% (with no icing) Weight Approx. 290 g (for D4A-3101N roller lever model) Note: 1. The above figures are initial values. 2. Excluding maintained models. 3. The values are calculated at an operating temperature of 5C to 35C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments. 4. 1,500 VAC is applied to the indicator lamp type. 5. Not including wobble levers (cat whisker, plastic rod, coil spring, and spring wire types). Type Ambient temperature Roller lever (See note 5-1.) -40C to 100C Plunger, flexible rod (See note 5-2.) -20C to 100C With indicator -10C to 80C Fluoro-rubber seal -10C to 120C 5-1. Excluding low-torque and high-sensitivity models. 5-2. Including roller lever low-torque and high-sensitivity operating models. General-purpose Limit Switch D4A-@N 81 Connections Contact Forms (Switch Boxes) STDP Double-break Switches Type Contact model Without indicator 1NC/1NO snap-action Operating pattern With neon lamp indicator (See note.) D4A-0100N D4A-0300N Za 4 With LED indicator (See note.) D4A-0E00N Lamp unit 3 Za 4 Lamp unit 3 4 2 1 Za 3 2 1 1 2 Lamp unit Lamp Unit Internal Circuits Lamp unit Energized 1-2 Lamp Unit Internal Circuits 3-4 Stroke Neon lamp LEDs Bridge rectifier Resistor Resistor Note: Switches with indicators are factory-set to light when the switch is not operated. DTDP Double-break Switches Each of these Switches can be used to replace two limit switches in applications, such as high-speed control in machine tools and switching motors between forward and reverse, that previously required 2 limit switches. This simplifies wiring, saves space, and reduces costs. Type Contact model Without indicator 2NC/2NO snap-action, D4A-0500N simultaneous operation With neon lamp indicator (See note.) D4A-0L00N Operating pattern Remarks With LED indicator (See note.) D4A-0P00N Energized 1-2 3-4 5-6 Head is compatible with double-break head. Can be switched for operation on both sides of actuator. 7-8 Stroke 2NC/2NO snap-action, D4A-0700N sequential operation (2-step operation) --- --- Energized Use the D4A-0017N Special Head. Energized Use the D4A-0018N Special Head. 1-2 3-4 5-6 7-8 Stroke 2NC/2NO snap-action, D4A-0900N central neutral operation --- --1-2 3-4 5-6 7-8 Left operation 82 General-purpose Limit Switch D4A-@N Free Right position operation Item Contact form Without indicator With neon lamp indicator (See note.) With LED indicator (See note.) D4A-0L00N D4A-0500N D4A-0700N D4A-0900N 4 Za 4 3 1 2 8 7 5 6 D4A-0P00N Lamp unit Lamp unit Lamp unit Za Za Za 1 3 8 2 5 Lamp unit Lamp unit --internal circuit Lamp unit 7 4 6 1 Lamp unit 3 8 2 5 Za 6 Lamp unit Neon lamp Bridge rectifier 7 Lamp unit Constant current diode Resistor LED Note: Switches with indicators are factory-set to light when the switch is not operated, but the setting can be changed to light for operation (dotted lines). Nomenclature DPDT Double-break Head With the Roller Lever and Side Plunger Switches, the direction of the switch head can be varied to any of the four directions by loosing the roller lever switch screws at the four corners of the head. Roller The roller actuator is made of hardened stainless steel and excels in resistance to wear. The Roller Lever Switch employs a system which allows selection of the operation of only one side (left or right) or both sides without use of any tools. Lever With the Roller Lever Switch, the lever can be installed anywhere in a 360 range (180 if the lever is reversed and attached to the shaft). Oil Seal Improved sealing property is ensured with a double-seal construction (a oil seal plus an X-ring seal). Operating Position Mark (arrow) Bearings The copper-alloy bearings ensure long life expectancy. Switch Box Boasts long life expectancy (50 million mechanical operations or more with the 2-pole Double-break Switches and 30 million mechanical operations or more with the DPDT Double-break Switches). Receptacle The plug-in type receptacle provides adequate space for wiring. Conduit Opening G 1/2 conduit threads featuring high sealing property are used. (Consult your OMRON representative for details on SC connectors). A terminal box with 1/2-14NPT conduit threads is also available on request. Ground Terminal Screw A ground terminal is provided to enhance safety. Sealed Gasket The employed full-cover method prevents the gasket from direct exposure to oil or water spray. Switch Box Screw A Phillips screw is used to secure the switch housing for ease of use, and features a measure to prevent the screw from coming off. Note: 1. NBR is used in rubber components. 2. Fluoro-rubber sealed types use fluoro-rubber. 3. For Roller Levers, there is some lever play in the free position (about 2 mm), but this is due to the structure of the head and does not interfere with performance. General-purpose Limit Switch D4A-@N 83 Easy-maintenance Block Mounting Block mounting makes it possible to easily assemble or disassemble the head, switch body, and receptacle of the D4A-@N by tightening or loosening the attached screws. Head Actuator Switch box Receptacle Engineering Data Electrical Durability (SPDT Double-break) Durability (x 104 operations) 125 VAC 250 VAC Operating frequencies: 30 operations/min, cos = 1 480 VAC Durability (x 104 operations) (Ambient temperature: 5C to 35C; ambient humidity: 40% to 70%) 125 VAC Operating frequencies: 30 operations/min, cos = 0.4 250 VAC 480 VAC Switching current (A) Switching current (A) 125 VAC Operating frequencies: 30 operations/min, cos = 1 250 VAC 480 VAC Durability (x 104 operations) Durability (x 104 operations) Electrical Durability (DPDT Double-break) Operating frequencies: 30 operations/min, cos = 0.4 125 VAC 250 VAC 480 VAC Switching current (A) 84 General-purpose Limit Switch D4A-@N Switching current (A) Installation Operation Changing the Operating Direction The head of the side rotary type can be converted in seconds to CW, CCW, or both-way operation. Follow the procedures on the right hand side for conversion (not applicable to the Maintained, Sequential Operating, Center Neutral Operating Switches). Operating Part (Rear of Head) Operating position arrow marks Procedures 1. Dismount the head by loosening the four screws that secure it. 2. Turn over the head to set the desired operation (CW, CCW, or both). The desired side can be selected by setting the mode selector knob shown in the figure. This knob is factory set to the "CW+CCW" (both-way operation) position. 3. When set to the CW position, the head rotates in clockwise direction. When set to the CCW position, the head rotates in counterclockwise direction. In either case, be sure to accurately align the arrow mark to the setting position. General-purpose Limit Switch D4A-@N 85 Head and Lever Positions The operating head can be positioned and locked in any of four 90 positions and a lever can lock in any position through 360 around the shaft of the Limit Switch. Furthermore, the lever can be reversed and attached to the shaft (refer to the figures below on the right hand side). Therefore the roller is compatible with a wide movement range of a dog. A Fork Lever Lock can be used with maintained models (D4A-0005N) only. Remove the head from the Switch by loosening the screws (the screws can be loosened but not removed from the head). The operating head can be positioned and locked in any of four 90 positions. The lever can lock in any position through 360 around the shaft. The lever can be reversed and attached to the shaft, in which case the switching operation should complete in a range of 0 to 180. 180 operating position 360 operating position Four, M4 x 12 There are four kinds of fork lever locks. The position of each roller is different. It is possible to use D4A-E00 through D4A-E30 levers instead, if they are reversed before attaching. They can be used with D4A-@@05N models only. D4A-E00 D4A-E10 D4A-E20 D4A-E30 By loosening the Allen-head bolt on an adjustable roller lever or rod lever, the length of the lever can be adjusted. D4A-C00 Loosen the bolt to adjust the length of the lever. D4A-D00 Adjustable between 33 and 91 mm Loosen the screw to adjust the length of the rod. Lighting Mode Selection of Indicators The lighting mode of the operation indicator can be changed easily between two modes: lighting when the Switch is operating and lighting when the Switch is not operating. Lights When Not Operating Lights When Operating (See note 1.) (See note 2.) Power supply Internal circuits 4 3 Load 4 3 1 2 2 1 Built-in switch 86 Power supply Built-in switch Internal circuits General-purpose Limit Switch D4A-@N Note: 1. The lamp is lit when the actuator is at the free position. The lamp will be off when the contacts of the Limit Switch have been actuated and snapped to each other at the operating position. Load 2. The lamp is lit when the contacts have been released and snapped only from the operating position. Change the lighting mode as follows: Push the claw securing the lamp section to the right (do not push strongly). Remove the lamp section. Mount the lamp section so that legend "NC-ON" or "NO-ON" will appear in the display window. Note: In either case, the lamp will not light when the load is ON. Lever Position D4A-A00 D4A-A10 67 to 72.5 59 to 64.5 52.9 to 58.4 44.9 to 50.4 D4A-A20 73 to 78.5 38.9 to 44.4 D4A-A30 86.9 to 92.4 25 to 30.5 Nameplate The whole switch model without lever is printed. The type of switch box is printed. (The type is also indicated on the head and receptacle.) Compatibility with D4A-@ The D4A-@N is compatible with the D4A-@ when the following accessories are attached to the D4A-@N. D4A-@ Receptacle box D4A-@N Switch box D4A-@N Head Note: The D4A-@N without the above accessories is not compatible with the D4A-@. General-purpose Limit Switch D4A-@N 87 Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Insert the model number code in @ for the switch body. 3. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. Roller Lever Switches Note: Levers of the side rotary type are optionally available. Standard D4A-1@01N, D4A-2@01N High-sensitivity D4A-1@02N, D4A-2@02N Low Torque D4A-1@03N, D4A-2@03N 62.5 48 Four, M4 (length: 12) screws for head 21 7.25 dia. 24.5 34 19 5.2+0.2 0 dia. mounting holes High-sensitivity/Low Torque D4A-1@04N, D4A-2@04N Sequential Operation D4A-2@17N Center Neutral Operating D4A-2@18N 2.6R 75.5 59.50.2 70.5 6 0.8 2.6R 5.2 29.40.2 42 Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 Two, M5 (length: 20) screws for box 1/2-14NPT conduit 62 47.5 21 Four, M4 (length: 12) screws for head Maintained D4A-1@05N, D4A-2@05N 7.25 dia. 38.1 19.1 5.2+0.2 0 dia. mounting holes 2.6R 59.50.2 75.5 70.5 6 0.8 2.6R 5.2 Two, M5 (length: 20) screws for box 29.40.2 42 1/2-14NPT conduit Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 SPDT Double-break Model D4A-1@01N D4A-1@02N D4A-1@03N D4A-1@04N D4A-1@05N OF max. 0.39 N*m 0.39 N*m 0.2 N*m 0.2 N*m 0.39 N*m RF min. 0.05 N*m 0.05 N*m --- --- --- PT max. 15 (12) 7 (6) 15 (12) 7 (6) 65 (60) OT min. 70 75 70 75 20 MD max. 5 (4) 4 (3) 5 (4) 4 (3) 35 (30) DPDT Double-break Model D4A-2@01N D4A-2@02N D4A-2@03N D4A-2@04N D4A-2@05N 0.39 N*m 0.2 N*m 0.2 N*m RF min. 0.05 N*m 0.05 N*m --- --- --- 0.05 N*m 0.02 N*m PT max. 15 (12) 7 (6) 15 (12) 7 (6) 65 (60) 1-stage: 12 (10) 2-stage: 20 (17) 19 (15) OT min. 70 75 70 75 20 65 65 MD max. 7 (6) 5 (4) 7 (6) 5 (4) 35 (30) 6 (5) 5 (4) 88 General-purpose Limit Switch D4A-@N 0.39 N*m D4A-2@18N 0.39 N*m The figures in the parentheses are average values. 0.39 N*m D4A-2@17N OF max. 0.39 N*m Side Plunger Switches Standard D4A-1@06N, D4A-2@06N Stainless steel PT OP plunger Four, M4 (length: 12) screws for head 21.5 19 21 31.1 10 dia. 5.2+0.2 0 dia. mounting holes 59.50.2 70.5 2.6R 75.5 6 0.8 2.6R 29.40.2 42 Horizontal Roller D4A-1@07-HN, D4A-2@07-HN Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 Two, M5 (length: 20) screws for box 5.2 1/2-14NPT conduit Four, M4 (length: 12) screws for head PT 21.5 19 11 dia.x 5 stainless steel roller OP 21 31.1 5.2+0.2 0 dia. mounting holes 59.50.2 70.5 2.6R 75.5 6 0.8 2.6R 5.2 29.40.2 42 Vertical Roller D4A-1@07-VN, D4A-2@07-VN Two, No.10-32UNF 16.5 (depth: 10) screws 28 for back-mounting 29.5 44 Two, M5 (length: 20) screws for box 1/2-14NPT conduit Four, M4 (length: 12) screws for head PT 21 OP 21.5 31.1 19 11 dia.x 5 stainless steel roller 5.2+0.2 0 dia. mounting holes 59.50.2 70.5 2.6R 75.5 6 0.8 2.6R 5.2 29.40.2 42 Adjustable D4A-1@08N, D4A-2@08N Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 Two, M5 (length: 20) screws for box 1/2-14NPT conduit Four, M4 (length: 12) screws for head M5 x 0.8 (length: 14 Allen-head bolt PT OP 21.5 19 21 31.1 5.2+0.2 0 dia. mounting holes 2.6R 75.5 59.50.2 70.5 6 0.8 2.6R 5.2 29.40.2 42 Model Two, M5 (length: 20) screws for box 1/2-14NPT conduit SPDT double-break D4A-1@06N D4A-1@07-HN D4A-1@07-VN Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 DPDT double-break D4A-1@08N 19.61 N D4A-2@06N 19.61 N D4A-2@07-HN D4A-2@07-VN 19.61 N 19.61 N D4A-2@08N OF max. 19.61 N 19.61 N 19.61 N 19.61 N RF min. 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N PT max. 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm 2.4 mm OT min. 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm MD max. 0.6 mm 0.6 mm 0.6 mm 0.6 mm 1.0 mm 1.0 mm 1.0 mm 1.0 mm OP 340.8 mm 440.8 mm 440.8 mm 41 to 47.5 mm 340.8 mm 440.8 mm 440.8 mm 41 to 47.5 mm General-purpose Limit Switch D4A-@N 89 Top Plunger Switches Standard D4A-1@09N, D4A-2@09N 10 dia. Stainless steel plunger PT 21 Four, M4 (length: 12) screws for head 27 OP 5.2+0.2 0 dia. mounting holes 59.50.2 2.6R 75.5 70.5 6 0.8 2.6R 5.2 Two, M5 (length: 20) screws for box 29.40.2 42 Roller Plunger D4A-1@10N, D4A-2@10N 1/2-14NPT conduit 11 dia. x 5 stainless steel roller Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 21 PT Four, M4 (length: 12) screws for head 27 OP 5.2+0.2 0 dia. mounting holes 2.6R 75.5 70.5 59.50.2 6 0.8 5.2 2.6R Two, M5 (length: 20) screws for box 29.40.2 42 Adjustable D4A-1@11N, D4A-2@11N 1/2-14NPT conduit M5 x 0.8 (length:14) Allen-head bolt PT Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 21 Four, M4 (length: 12) screws for head OP 27 5.2+0.2 0 dia. mounting holes 59.50.2 2.6R 75.5 70.5 6 0.8 2.6R 5.2 29.40.2 42 Model Two, M5 (length: 20) screws for box 1/2-14NPT conduit Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 SPDT double-break D4A-1@09N OF max. 17.65 N RF min. PT max. D4A-1@10N DPDT double-break D4A-1@11N D4A-2@09N D4A-2@10N D4A-2@11N 17.65 N 17.65 N 17.65 N 17.65 N 17.65 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N 1.6 mm 1.6 mm 1.6 mm 1.6 mm 1.6 mm 1.6 mm OT min. 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm 5.1 mm MD max. 0.4 mm 0.4 mm 0.4 mm 1.0 mm 1.0 mm 1.0 mm OP 460.8 mm 560.8 mm 55.5 to 62 mm 460.8 mm 560.8 mm 55.5 to 62 mm 90 General-purpose Limit Switch D4A-@N Flexible Rod Switches Spring Wire D4A-1@12N, D4A-2@12N (see note 1) 8 dia. max. 1.8 dia. (see note 2) PT Stainless steel wire rod 330 (287) 21 Four, M4 (length: 12) screws for head 88 27 5.2+0.2 0 dia. mounting holes 59.50.2 70.5 2.6R 75.5 6 0.8 Two, M5 (length: 20) screws for box 5.2 2.6R 29.40.2 42 1/2-14NPT conduit Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 (see note 1) Plastic Rod D4A-1@14N, D4A-2@14N (see note 2) PT 7 dia. Plastic rod (106.5) 21 Four, M4 (length: 12) screws for head 88.5 150 27 5.2+0.2 0 dia. mounting holes 2.6R 59.50.2 75.5 70.5 6 0.8 2.6R 5.2 29.40.2 42 Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting Two, M5 (length: 20) screws for box 1/2-14NPT conduit 29.5 44 (see note 1) Cat Whisker D4A-1@15N, D4A-2@15N (see note 2) PT 1.4 dia. Stainless steel wire rod (124) 21 Four, M4 (length: 12) screws for head 93.5 170.5 27 5.2+0.2 0 dia. mounting holes 70.5 59.50.2 2.6R 75.5 6 0.8 2.6R 5.2 29.40.2 42 Two, M5 (length: 20) screws for box 1/2-14NPT conduit Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 Note: 1. The stainless rod can be operated from any direction except the axial direction (i.e., from the top). 2. The optimum operating range of the stainless rod is within 1/3 of the entire length from the top end. General-purpose Limit Switch D4A-@N 91 Coil Spring D4A-1@16N, D4A-2@16N (see note 1) (see note 2) PT (106.5) 6.5 dia. 150 Stainless steel coil spring 21 Four, M4 (length: 12) screws for head 27 5.2+0.2 0 dia. mounting holes 2.6R 59.50.2 75.5 70.5 6 0.8 5.2 2.6R Two, No.10-32UNF 16.5 (depth: 10) screws for 28 back-mounting 29.5 44 Two, M5 (length: 20) screws for box 29.40.2 42 1/2-14NPT conduit Note: 1. The stainless rod can be operated from any direction except the axial direction (i.e., from the top). 2. The optimum operating range of the stainless rod is within 1/3 of the entire length from the top end. Model SPDT double-break D4A-1@12N DPDT double-break D4A-1@14N D4A-1@15N D4A-1@16N D4A-2@12N D4A-2@14N D4A-2@15N OF max. 0.98 N 1.47 N 0.98 N 1.47 N PT max. 15 (5) 15 (5) 15 (5) 15 (5) D4A-2@16N Levers (for Roller Lever Switches) Note: No D4A-0003N or D4A-0004N head should be used with the adjustable roller lever or mechanical malfunctioning could result because the total weight of the adjustable roller lever is comparatively large. Use a standard-load head (D4A-0001N or D4A-0002N) instead. Roller Lever D4A-A00 Roller Lever D4A-A10 19.5 11.5 7.9 19.1 dia. Roller Lever D4A-A20 19.1 dia. Stainless sintered roller M5 Allen bolt 18 M5 Allen bolt 9 Roller Lever D4A-A30 18 9 Roller Lever D4A-B06 19.1 dia. 7.9 (see note) 38.1 33.7 7.3 dia. 18 9 39.4 Note: Stainless sintered roller 21 15 17.5 dia. (see note) M5 Allen bolt 38.1 7.3 dia. 7.3 dia. M5 Allen bolt 7.3 dia. 18 Note: Stainless sintered roller General-purpose Limit Switch D4A-@N 7.9 Stainless sintered roller 38.1 38.1 92 19.1 dia. 7.9 Stainless sintered roller 9 M5 Allen bolt 7.3 dia. 18 9 16.5 Adjustable Roller Lever D4A-C00 19.1 dia. Stainless Adjustable Rod Lever D4A-D00 7.9 14 20 10.5 3 dia. sintered roller Stainless rod 6.4 graduation 150 max. (adjustable) 33 to 91 (adjustable) 13 7.3 dia. 7.3 dia. 160 113 M5 Allen bolt 4.5 M5 Allen bolt 4.5 13 18 21.2 7.5 21.2 2.5 Fork Lever Lock 17 D4A-E30 (2) Fork Lever Lock D4A-E20 17 Stainless sintered roller 7.9 3.6 19.1 dia. (2) 7.9 3.6 38.1 38.1 7.3 dia. Stainless sintered roller M5 Allen bolt 38.1 Fork Lever Lock D4A-E10 7.9 9 Stainless sintered roller 38.1 (See note.) Fork Lever Lock D4A-E00 26 26 22 6.2 3.6 7.3 dia. M5 Allen bolt (See note.) (2) 90 19.1 dia. 90 9 Stainless sintered roller 22 6.2 (2) 19.1 dia. 38.1 7.3 dia. M5 Allen bolt 38.1 9 Stainless sintered roller 19.1 dia. 90 38.1 7.9 3.6 Stainless sintered roller Stainless sintered roller M5 Allen bolt (See note.) 9 90 7.3 dia. Stainless sintered roller 38.1 (See note.) Nylon Loop Lever D4A-F00 7.3 dia. M5 Allen bolt 25 max. Nylon M5 Allen bolt Note: A Fork Lever Lock can be used with D4A-@@05N models only. General-purpose Limit Switch D4A-@N 93 Precautions Refer to the "Precautions for General-purpose Limit Switches (Including Multiple Limit Switches, Mechanical Touch Switches, High-precision Switches, Touch Switches, On-site Flexible Switches; Not Including Safety Switches)" on page 17. Correct Use Tightening Torque Operating Environment To maintain the high sealing capability of the Limit Switch, tighten the screws for the head and switch box with the following torques: * Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. * Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. Suitable Not Suitable Head (four 12-mm M4 screws): 1.2 to 1.4 N*m Switch box (two 20-mm M5 screws): 2.4 to 2.7 N*m Solderless Terminals The D4A-@N with DPDT double-break incorporates solderless terminals. Operation The operating methods, cam and dog shapes, operating frequency, and overtravel (OT) have a significant effect on the service life and accuracy of the Limit Switch. The shape of the cam should be as smooth as possible. * Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance. * The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge killers) or remove the source of silicon gas. Mounting Model A marginal overtravel (OT) value should be set. The ideal value is the rated OT value x 0.7. The actuator should not be remodeled to change the operating position. Connectors To satisfy IP67, apply sealing tape to the connector conduit. Appropriate outer diameter of cables is 5.5 to 14 dia. Use OMRON's SC-@M Series. Tighten the Connectors to a torque of 1.8 to 2.2 N*m. Maintenance and Repair 1/2-14NPT Conduit The user must not maintain or repair equipment incorporating any D4A-N model. Contact the manufacturer of the equipment for any maintenance or repairs required. D4A-1@@@N D4A-2@@@N Front Mounting Two, 5.2+0.2 0 dia. holes or M5 tapped holes Tightening Torque A loose screw may cause malfunctions. Be sure to tighten each screw to the proper tightening torque as shown in the table. 59.50.15 29.40.15 Rear Mounting (Rear View) Two, 6.2+0.2 0 dia. holes (Recommended mounting screws: M6. Switch Box depth: 10.) 59.50.15 29.40.15 94 General-purpose Limit Switch D4A-@N No. 1 Type Appropriate tightening torque Terminal screws (M3.5 screws) 0.78 to 0.88 N*m (including grounding terminals) 2 Head mounting screws 3 Switch box mounting screws 1.18 to 1.37 N*m 2.35 to 2.75 N*m 4 Body mounting screws (See note.) 4.90 to 5.88 N*m 5 Connectors 1.77 to 2.16 N*m 6 Actuator mounting screws 2.45 to 2.65 N*m Note: When using M5 Allen-head bolts, particularly when the head direction has been changed, check the torque of each screw and make sure that the screws are free of foreign substances, and that each screw is tightened to the proper torque. General-purpose Limit Switch D4A-@N 95 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron's payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in "break down" situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://oeweb.omron.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, "including" means "including without limitation"; and "Omron Companies" (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at www.omron247.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONICS LLC 1 Commerce Drive Schaumburg, IL 60173 Tel: 847.843.7900 For U.S. technical support or other inquiries: 800.556.6766 OMRON CANADA, INC. 885 Milner Avenue Toronto, Ontario M1B 5V8 Tel: 416.286.6465 MEXICO SALES OFFICES Mexico, D.F. 555.660.3144 Ciudad Juarez 656.623.7083 Monterrey, N.L. 818.377.4281 Queretaro 442.135.4510 BRAZIL SALES OFFICE Sao Paulo 55.11.2101.6310 ARGENTINA SALES OFFICE Cono Sur 54.114.787.1129 CHILE SALES OFFICE Santiago 562.206.4592 OMRON ON-LINE Global www.omron.com USA www.omron247.com Canada www.omron.ca Brazil www.omron.com.br Latin America www.espanol.omron.com OTHER LATIN AMERICAN SALES mela@omron.com Cat. No. X019-E1-07............................407............Specifications subject to change without notice..............Printed in USA