Model Super TJE Ultra Precision Pressure Transducer DESCRIPTION Model Super TJE is one of the most accurate industrial pressure The gage Model Super TJE is a strain gage based transducer transducers available today. The Super TJE features 0.05 % and features a unique "true gage" design which utilizes a accuracy and zero temperature error of less than 0.0015 % second welded stainless steel diaphragm that hermetically seals FS/F. These specifications are maintained by welding a double the strain gage circuitry from atmospheric contamination. This jacket shell of stainless steel along with our proprietary "true design references the primary pressure sensing diaphragm to gage" second diaphragm that isolates the strain gage circuitry the atmosphere, and provides a stable zero regardless of the from atmospheric contamination. High output options of 5 Vdc transducer environment. or 10 Vdc and 4 mA to 20 mA eliminate the need for an amplifier card in the data system. An optional signature calibration chip provides calibration information for automatic set-up with the Model SC four-or-twelve-channel digital indicator. FEATURES * 0.0015 % FS/F temperature effect * 0.05 % accuracy * 10 psig to 7500 psig range * True gage or absolute * mV/V, 4 mA to 20 mA, 0 Vdc to 5 Vdc, or 0 Vdc to 10 Vdc output * Isolated double wall construction * Enhanced temperature stability * Intrinsically safe available (2N option only)12 * CE13 The absolute Model Super TJE has an all-welded vacuum reference chamber assuring long-term stability. Model Super TJE PERFORMANCE SPECIFICATIONS Characteristic Measure Pressure ranges1 10 psig; 15, 25, 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500 psig/a Accuracy10 0.05 % full scale Resolution Infinite Calibration 5-point calibration: 0 %, 50 %, and 100 % of full scale ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero 0.0015 % full scale/F Temperature effect, span 0.0015 % reading/F Temperature effect, sealing Hermetically sealed IP68/NEMA 6P ELECTRICAL SPECIFICATIONS Characteristic Measure Strained gage type Bonded foil Insulation resistance 5000 mOhm @ 50 Vdc Bridge resistance 350 ohm Shunt calibration data Included Electrical termination (std) PTIH-10-6P or equiv. (Hermetic stainless) Mating connector (not incl) PT06A-10-6S or equiv. (AA111) OPTION CODES Range Code Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensorship for updated listings. Pressure ranges 10, 15, 25, 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500 psig/a Temperature compensation 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 7 1g. 70 F to 325 F 7 Internal amplifiers 4 2a. 0 Vdc to 5 Vdc (4 wire) output4 2c. 0 Vdc to 5 Vdc output4 2j. 4 mA to 20 mA (3 wire) output4 2k. 4 mA to 20 mA (two wire) output4, 15 2n. 4 mA to 20 mA (two wire) intrinsically safe4, 15 2t. 0 Vdc to 10 Vdc output4 2u. Unamp., mV/V output Internal amplifier enhancements 3a. Input/output isolation14 3d. Remote buffered shunt calibration Pressure ports6 5a. 1/4-18 NPT female (2000 psi to 7500 psi) 5b. 1/4-18 NPT male (10 psi to 1500 psi) 5d. 7/16-20 UNF male 5g. G 1/4 male 5t. G 1/2 male Electrical termination 6a. Bendix PTIH-10-6P (or equiv), 6 pin (max 250 F) 6e. Integral cable: Teflon (0 F to 180 F) 6f. Integral cable: PVC (-20 F to 160 F) 6g. Integral cable: Neoprene (0 F to 180 F) 5 6h. Integral cable: Silicone (-65 F to 300 F) 6i. Integral underwater cable (max 180 F)5 6m. DIN 43650 6q. Molded integral cable: Polyurethane (max 180 F) 5 6t. Integral cable with Heyco spring strain relief (5 ft) Shunt calibration 8a. Precision internal resistor7 Special calibration6 9a. 10 point (5 up/5 down) 20 % increments @ 70 F (gage) 9b. 20 point (10 up/10 down) 10 % increments @ 70 F (gage) Bridge resistance 12b. 5000 ohm (foil) (max 400 F) Zero and span adjustment 14a. No access to pots 14b. Top access to pots Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration7 53t. TEDS IEEE1451.4 module11 MECHANICAL SPECIFICATIONS Characteristic Measure Media All gases and liquids compatible with wetted parts Wetted parts material 10 psi to 1500 psi 17-4 PH stainless steel 2000 psi to 7500 psi 15-5 PH stainless steel Weight 12 oz Case material Stainless steel Marking Permanent metal name plate MILSTD130F 4.3; Individual sequential serial number per sensor; Country of origin and date of manufacture 2 Honeywell * Sensing and Control Ultra Precision Pressure Transducer RANGE CODES Pressure range 10** 15 25 50 75 100 150 200 300 500 750 1000 1500 2000 3000 5000 7500 AV BJ BL BN BP BR CJ CL CP CR CT CV DJ DN DR DT D mm [in] psia NA 41 [1.63] D mm [in] psig 51 [2.0] 3000 3500 4000 RANGE CODE 41 [1.63] L mm [in] psia NA 66 [2.62] L* mm [in] psia 92 [3.63] NA DL L mm [in] psig 64 [2.5] 66 [2.62] L* mm [in] psig 92 [3.63] 89 [3.5] Over pressure 150 % FS (test) (psi) Over pressure (burst) (psi) 100 200 Port volume cm3 [in3] 2,8[0.17] Natural frequency (Hz) 1.6 K 2.1 K 400 800 2000 8000 12 K 20 K 25 K 40 K 54 K 60 K 3,1 [0.12] 2.5 K 2.9 K 3.5 K 4.5 K 6K 7K 9K 9.5 K 12 K 17 K 20 K 35 K * Length with amplified option ** 10 psi not available with absolute pressure Mounting diagram and characteristics Typical system diagram For reference only Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Honeywell * Sensing and Control 3 Model Super TJE INTERNAL AMPLIFIERS Voltage output: Option 2a4 Vehicle voltage output: Option 2c4 Vehicle voltage output: Option 2t4 Current three-wire: Option 2j4 Current twowire: Option 2k4 Intrinsically safe amp: Option 2n*** 2 mV/V 0 Vdc to 5 Vdc 0-5 Vdc or 5 Vdc @ 5 mA 0-10 Vdc or 10 Vdc @ 5 mA 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA Input power (voltage) 10 Vdc regulated 15 Vdc or 26-32 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc3 9 Vdc to 32 Vdc3 9 Vdc to 28 Vdc3 Input power (current) 28.5 mA @ 10 Vdc 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA Freq. resp. (amp) Natural frequency 2000 Hz 3000 Hz 3000 Hz 2500 Hz 2500 Hz 2000 Hz Power supply rej. NA 60 db 60 db 60 db 60 db 60 db 60 db Operating temp. -100 F to 250 F -20 F to 185 F -40 F to 200 F -40 F to 185 F -40 F to 185 F -40 F to 185 F -20 F to 185 F Reverse voltage protection NA Yes Yes Yes Yes Yes Yes Short cir. protection NA Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std)3 A (+) Excitation B (+) Excitation C (-) Excitation D (-) Excitation E (-) Output F (+) Output A (+) Supply B Output com. C Supply ret. D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B Output com.** C Supply ret.** D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B Output com.** C Supply ret.** D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B Output com.** C Supply ret.** D (+) Output E Shunt Cal 1 F Shunt Cal 2 A (+) Supply B No conn. C No conn. D (+) Output E Case ground F No conn. A (+) Supply B No conn. C No conn. D (+) Output E Case ground F No conn. Wiring code: cable3,8,9 R (+) Excitation Bl (-) Excitation G (-) Output W (+) Output R (+) Supply Bl Output com. G Supply ret. W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl Output com* G Supply ret.* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl Output com* G Supply ret.* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl Output com* G Supply ret.* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 R (+) Supply Bl (+) Output W Case ground R (+) Supply Bl (+) Output W Case ground Amplifier Specifications mV/V output standard Output signal * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See Honeywell's Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00. 4 Honeywell * Sensing and Control Model Super TJE NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Ultra Precision Pressure Transducer Gage pressure units greater than 500 psi are sealed at atmospheric pressure. Input power (voltage) for internal amplifier options 2j, 2k, 2n (2N) depends on load resistance. Interconnecting shunt cal. 1 with shunt cal. 2 terminal provides 50 % (unamplified units), 75% (4 mA to 20 mA three-wire units), or 80 % (voltage amp. units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2a, 2b, 2c, 2t and 2j. Not available with temperatures below -29 C [-20 F] or above 85 C [185 F]. Not available with option 1c, 1e, 1f, 1g, 1h or 1i. Availability varies according to range. Cannot be used with amplified option. G=Green; B=Blue; W=White; Bl=Black; Br=Brown; Y=Yellow; R=Red; O=Orange. Color specifying cable and number or letter specifying connector. No mating connector necessary with cable option. Accuracies stated are expected for best fit straight line for all errors including linearity, hysteresis & non-repeatability thru zero. Consult factory for TEDS availability with amplified models. Range dependent; consult factory. Termination dependent; consult factory. Internal amp and termination dependent; consult factory. Input/output isolation only available with voltage (2A, 2B, or 2C amplifiers). 5000 ohm bridge required. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY * DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008605-1-EN IL50 GLO May 2008 Copyright (c) 2008 Honeywell International Inc. All rights reserved.