Ultra Precision Pressure Transducer
Model Super TJE
DESCRIPTION
Model Super TJE is one of the most accurate industrial pressure
transducers available today. The Super TJE features 0.05 %
accuracy and zero temperature error of less than 0.0015 %
FS/°F. These specifications are maintained by welding a double
jacket shell of stainless steel along with our proprietary “true
gage” second diaphragm that isolates the strain gage circuitry
from atmospheric contamination. High output options of 5 Vdc
or 10 Vdc and 4 mA to 20 mA eliminate the need for an amplifier
card in the data system. An optional signature calibration chip
provides calibration information for automatic set-up with the
Model SC four-or-twelve-channel digital indicator.
The gage Model Super TJE is a strain gage based transducer
and features a unique “true gage” design which utilizes a
second welded stainless steel diaphragm that hermetically seals
the strain gage circuitry from atmospheric contamination. This
design references the primary pressure sensing diaphragm to
the atmosphere, and provides a stable zero regardless of the
transducer environment.
The absolute Model Super TJE has an all-welded vacuum
reference chamber assuring long-term stability.
FEATURES
• 0.0015%FS/°Ftemperatureeffect
• 0.05%accuracy
• 10psigto7500psigrange
• Truegageorabsolute
• mV/V,4mAto20mA,0Vdcto5Vdc,or0Vdcto10Vdc
output
• Isolateddoublewallconstruction
• Enhancedtemperaturestability
• Intrinsicallysafeavailable(2Noptiononly)12
• CE13
2Honeywell•SensingandControl
Model Super TJE
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges1 10psig;15,25,50,75,100,150,200,
300,500,750,1000,1500,2000,3000,
5000,7500psig/a
Accuracy10 ±0.05 % full scale
Resolution Innite
Calibration 5-point calibration: 0 %, 50 %, and 100
% of full scale
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature compensated 15°Cto71°C[60°Fto160°F]
Temperature effect, zero 0.0015 % full scale/°F
Temperature effect, span 0.0015 % reading/°F
Temperature effect, sealing HermeticallysealedIP68/NEMA6P
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strained gage type Bonded foil
Insulationresistance 5000 mOhm @ 50 Vdc
Bridge resistance 350 ohm
Shunt calibration data Included
Electricaltermination(std) PTIH-10-6Porequiv.(Hermeticstain-
less)
Matingconnector(notincl) PT06A-10-6Sorequiv.(AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media All gases and liquids compatible with
wetted parts
Wetted parts material
10 psi to 1500 psi 17-4PHstainlesssteel
2000psito7500psi 15-5 PH stainless steel
Weight 12 oz
Case material Stainless steel
Marking PermanentmetalnameplateMIL-
STD130F4.3;Individualsequential
serial number per sensor; Country of
origin and date of manufacture
OPTION CODES
Range Code Many range/option combinations are available in our
quick-ship and fast-track manufacture programs.
Please see http://sensing.honeywell.com/TMsensor-
ship for updated listings.
Pressure
ranges
10,15,25,50,75,100,150,200,300,500,750,
1000,1500,2000,3000,5000,7500psig/a
Temperature
compensation
1a.60°Fto160°F
1b. 30 °F to 130 °F
1c.0°Fto185°F
1d. -20 °F to 130 °F
1e. -20 °F to 200 °F
1f.70°Fto250°F7
1g.70°Fto325°F7
Internal
ampliers 4
2a.0Vdcto5Vdc(4wire)
output4
2c. 0 Vdc to 5 Vdc output4
2j.4mAto20mA(3wire)
output4
2k.4mAto20mA(two
wire)output4, 15
2n. 4 mA to 20 mA
(twowire)intrinsi-
cally safe4, 15
2t. 0 Vdc to 10 Vdc
output4
2u. Unamp., mV/V
output
Internal
amplier
enhance-
ments
3a.Input/outputisolation14
3d. Remote buffered shunt calibration
Pressure
ports6
5a.1/4-18NPTfemale
(2000psito7500psi)
5b.1/4-18NPTmale(10
psito1500psi)
5d.7/16-20UNFmale
5g. G 1/4 male
5t. G 1/2 male
Electrical
termination
6a.BendixPTIH-10-6P(or
equiv),6pin(max250°F)
6e.Integralcable:Teon(0
°Fto180°F)
6f.Integralcable:PVC(-20
°Fto160°F)
6g.Integralcable:Neo-
prene(0°Fto180°F)5
6h.Integralcable:Silicone
(-65°Fto300°F)
6i.Integralunderwater
cable(max180°F)5
6m.DIN43650
6q.Moldedintegral
cable: Polyure-
thane(max180
°F)5
6t.Integralcable
with Heyco spring
strainrelief(5ft)
Shunt
calibration
8a.Precisioninternalresistor7
Special
calibration6
9a.10point(5up/5down)20%increments@70
°F(gage)
9b.20point(10up/10down)10%increments@
70°F(gage)
Bridge
resistance
12b.5000ohm(foil)(max400°F)
Zero and span
adjustment
14a.Noaccesstopots
14b. Top access to pots
Shock and
vibration
44a. Shock and vibration resistance
Interfaces 53e. Signature calibration7
53t.TEDSIEEE1451.4module11
Honeywell•SensingandControl3
Ultra Precision Pressure Transducer
MOUNTING DIAGRAM AND CHARACTERISTICS TYPICAL SYSTEM DIAGRAM
For reference only
SPECIAL REQUIREMENTS (CONSULT FACTORY)
Haveaspecialrequirement?Newcasepressure,differentcablelengths,
electrical connectors, or materials? Consult our factory by calling +1
614-850-5000(800-848-6564).Customizationiskeytoourtestand
measurement business. Special outputs, wiring codes, and calibrations
are all standard to us.
RANGE CODES
Pressure
range 10** 15 25 50 75 100 150 200 300 500 750 1000 1500 2000 3000 5000 7500
RANGE
CODE
AV BJ BL BN BP BR CJ CL CP CR CT CV DJ DL DN DR DT
D mm [in]
psia NA 41[1.63]
D mm [in]
psig 51[2.0] 41[1.63]
L mm [in] psia NA 66[2.62]
L* mm [in]
psia NA 92[3.63]
L mm [in] psig 64[2.5] 66[2.62]
L* mm [in]
psig 89[3.5] 92[3.63]
Over pressure
(test) (psi) 150 % FS
Over pressure
(burst) (psi) 100 200 400 800 2000 3000 3500 4000 8000 12 K 20 K 25 K
Port volume
cm3 [in3]2,8[0.17] 3,1[0.12]
Natural
frequency
(Hz)
1.6K 2.1
K
2.5
K
2.9
K
3.5
K
4.5
K6K 7K 9 K 9.5
K12 K 17K 20 K 35 K 40 K 54 K 60K
*Lengthwithampliedoption
** 10 psi not available with absolute pressure
4Honeywell•SensingandControl
Model Super TJE
INTERNAL AMPLIFIERS
Amplier
Specications
mV/V output
standard
Voltage out-
put: Option
2a4
Vehicle volt-
age output:
Option 2c4
Vehicle volt-
age output:
Option 2t4
Current
three-wire:
Option 2j4
Current two-
wire: Option
2k4
Intrinsically
safe amp:
Option 2n***
Output signal 2 mV/V 0 Vdc to
5 Vdc
0-5 Vdc or ±5
Vdc @ 5 mA
0-10 Vdc or
±10 Vdc @ 5
mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power
(voltage)
10 Vdc regu-
lated
±15 Vdc or
26-32Vdc
11Vdcto28
Vdc
15Vdcto28
Vdc
22 Vdc to 32
Vdc3
9 Vdc to
32 Vdc3
9 Vdc to
28Vdc3
Input power
(current)
28.5mA@10
Vdc
45 mA 40 mA 40 mA 65mA 4mAto28mA 4 mA to 24 mA
Freq. resp. (amp) Naturalfre-
quency
2000 Hz 3000 Hz 3000 Hz 2500 Hz 2500 Hz 2000 Hz
Power supply rej. NA 60db 60db 60db 60db 60db 60db
Operating temp. -100 °F to 250
°F
-20°Fto185°F -40 °F to 200 °F -40°Fto185°F -40°Fto185°F -40°Fto185°F -20°Fto185°F
Reverse voltage
protection
NA Yes Yes Yes Yes Yes Yes
Short cir.
protection
NA Momentary Momentary Momentary Yes Yes Yes
Wiring code:
connector (std)3
A(+)Excitation
B(+)Excitation
C(-)Excitation
D(-)Excitation
E(-)Output
F(+)Output
A(+)Supply
B Output com.
C Supply ret.
D(+)Output
E Shunt Cal 1
F Shunt Cal 2
A(+)Supply
B Output
com.**
C Supply ret.**
D(+)Output
E Shunt Cal 1
F Shunt Cal 2
A(+)Supply
B Output
com.**
C Supply ret.**
D(+)Output
E Shunt Cal 1
F Shunt Cal 2
A(+)Supply
B Output
com.**
C Supply ret.**
D(+)Output
E Shunt Cal 1
F Shunt Cal 2
A(+)Supply
BNoconn.
CNoconn.
D(+)Output
E Case ground
FNoconn.
A(+)Supply
BNoconn.
CNoconn.
D(+)Output
E Case ground
FNoconn.
Wiring code:
cable3,8,9
R(+)Excitation
Bl(-)Excitation
G(-)Output
W(+)Output
R(+)Supply
Bl Output com.
G Supply ret.
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl Output com*
G Supply ret.*
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl Output com*
G Supply ret.*
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl Output com*
G Supply ret.*
W(+)Output
B Shunt Cal 1
Br Shunt Cal 2
R(+)Supply
Bl(+)Output
W Case ground
R(+)Supply
Bl(+)Output
W Case ground
* Black and green wires are internally connected.
** Pins B and C are internally connected.
***SeeHoneywell’sWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.
Sensing and Control
Automation and Control Solutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008605-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Model Super TJE Ultra Precision Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specicwarrantydetails.Ifwarrantedgoodsarereturnedto
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensingorcall+1-815-235-6847
Email inquiries to info.sc@honeywell.com
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stopdevicesorinanyotherapplicationwherefailureof
theproductcouldresultinpersonalinjury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisfor
referenceonly.DONOTUSEthisdocumentasproduct
installationinformation.
•Completeinstallation,operationandmaintenance
informationisprovidedintheinstructionssuppliedwith
eachproduct.
Failure to comply with these instructions could result in
death or serious injury.
NOTES
1. Gage pressure units greater than 500 psi are sealed at atmospheric
pressure.
2. Inputpower(voltage)forinternalamplieroptions2j,2k,2n(2N)
depends on load resistance.
3. Interconnectingshuntcal.1withshuntcal.2terminalprovides50
%(unampliedunits),75%(4mAto20mAthree-wireunits),or
80%(voltageamp.units)offullscaleoutputforquickcalibration.
Shunt calibration comes standard with internal amplifier options 2a,
2b, 2c, 2t and 2j.
4. Notavailablewithtemperaturesbelow-29°C[-20°F]orabove85
°C[185°F].
5. Notavailablewithoption1c,1e,1f,1g,1hor1i.
6. Availabilityvariesaccordingtorange.
7. Cannotbeusedwithampliedoption.
8. G=Green;B=Blue;W=White;Bl=Black;Br=Brown;Y=Yellow;
R=Red;O=Orange.Colorspecifyingcableandnumberorletter
specifying connector.
9. Nomatingconnectornecessarywithcableoption.
10. Accuraciesstatedareexpectedforbesttstraightlineforallerrors
including linearity, hysteresis & non-repeatability thru zero.
11. Consult factory for TEDS availability with amplified models.
12. Range dependent; consult factory. Termination dependent; consult
factory.
13. Internalampandterminationdependent;consultfactory.
14. Input/outputisolationonlyavailablewithvoltage(2A,2B,or2C
ampliers).
15. 5000 ohm bridge required.