BXA40 SERIES
Triple output
[ 2 YEAR WARRANTY ]
• Meets telecom power supply interface standard
ETS300-132-2
• EN60950, CSA950 and UL1950 safety approvals
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• Fixed frequency operation at 400kHz
• MTBF in excess of 500,000 hours
• Basic insulation system with 1500V isolation
• Pin-compatible with NFC40 Series
The BXA40 Series providing up to 40 Watts, comprising 4 different models, has been
conceived as an applications-specific range of DC/DC converters, specifically addressing
telecommunications, industrial electronics, test equipment, mobile telecommunications
and distributed power applications. The series offers two wide input voltage ranges, 18-
36VDC and 36-75VDC, and is available with 5/±12V and 5/±15V triple outputs. The
BXA40 series is designed to meet ETSI telecoms interface standard ETS300-132-2. With
safety approval to IEC950 and basic insulation, the 48VDC models are ideal for
telecommunications applications. The 24V models are particularly suited to industrial and
test equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity
compliance. Other features include low output ripple, overvoltage protection, short circuit
protection and remote enable.
SPECIFICATION
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
PAGE 140
OUTPUT SPECIFICATIONS
Line regulation Main output ±0.5%
(See Note 2) Auxiliary output ±2.0%
Load regulation Main output ±1.0%
(See Note 3) Auxiliary output ±3.0% typ.,
±5.0% max.
Load cross regulation Main output ±1.0%
(See Note 4) Aux. output ±3.0% typ., ±5.0% max.
Ripple and noise Main output 50mV pk-pk
(20MHz bandwidth) 20mV rms
Auxiliary output 100mV pk-pk
20mV rms
Temperature coefficient ±0.02%/°C
Overvoltage protection Main output 6.8V (nom.)
transorbs fitted Auxiliary outputs 16/20V (nom.)
Short circuit protection Main output 11A
(See Note 5) Auxiliary output 5A
Transient response 25% to 100% load 4.0%
Voltage accuracy Main output ±1.0%
Auxiliary output ±3.0%
Minimum Load Main output 0.6A
Auxiliary outputs 0.03A/0.04A
INPUT SPECIFICATIONS
Input voltage range 24Vin nominal 18 to 36VDC
48Vin nominal 36 to 75VDC
Reverse voltage External fuse (See Note 7)
protection
Max. input rise and 48V 5V/ms
fall time ETS300-132
Start-up time 30ms typ.
Remote ON/OFF
Logic compatibility CMOS/TTL
ON Open-circuit
OFF <1VDC
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15, Level B
(See Notes 6, 9)
Radiated emissions EN55022, FCC part 15 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 1
Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/output 1500VDC
Basic insulation, input/case 1500VDC
Switching frequency Fixed 400kHz (typical)
Approvals and EN60950, UL1950
standards (pending) CSA C22.2 No. 950
Case material Aluminum substrate
with plastic case
Material flammability UL94V-0
Weight 85g typ. (3.0oz)
MTBF MIL-HDBK-217F 500,000 hours
Size 2.2 x 2.2 x 0.5 inches
55.9 x 55.9 x 12.7 mm
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Baseplate operating -40°C to +105°C
temperature
Non-operating -55°C to +105°C
Thermal impedance No air flow, no heatsink 8.5°C/W
(See Note 8) No air flow, with heatsink 7.2°C/W
Data Sheet © Artesyn Technologies
®
2000
The information and specifications contained in this data sheet are believed to be correct at
time of publication. However, Artesyn Technologies accepts no responsibility for
consequences arising from printing errors or inaccuracies. Specifications are subject to
change without notice. No rights under any patent accompany the sale of any such product(s)
or information contained herein.
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 14501-3336-7009
Licence No. 6296
UL1950 File No. E174104
CSA C22.2 No. 950 File No. LR41062C
Notes
1 Nominal line, at no load.
2 Nominal line to high line, nominal line to low line.
3 Load regulation:
Main output (V1): 25 to 100% with 25% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 25% to 100% balanced on all outputs.
4 Cross regulation:
Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%.
Auxiliary outputs (V2 and V3): main output 100% load, auxiliary 100%,
other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other
auxiliary 25% to 100%.
5 Short circuit protection, 1 minute on auxiliary outputs.
6 For EMI compliance to EN55022 level B please consult factory for details.
For EMI compliance to EN55022 level A, refer to BXA40 Design Note 101.
7 Reverse voltage protection, refer to BXA40 Design Note 101.
8 The maximum operating ambient temperature, without derating depends
on internal power dissipation and module efficiency and cooling method.
Download BXA40 Design Note 101 which provides detailed thermal
calculations and design-in hints from the Artesyn website.
9 An external filter capacitor is necessary for safe operation of the 24V input
models. It is also suggested that an external filter capacitor be used on
the 48V input models. A 4µF (or greater) film capacitor such as: ITW
Paktron Capstick series, part number 405K100CS4 4µF/100V is
recommended, if filtering is not used. See BXA40 Design Note 101.
10 Units with the suffix ‘-M’ at the end of the model number are offered as
standard with metric threaded inserts (M3). To order units with imperial
threaded inserts (4-40 UNC) please remove the suffix ‘-M’ from the model
number. These inserts are used for bolting the unit to a PCB and/or fixing
heatsinks.
11 A top mounted heatsink kit is available for the BXA40. The heatsink may
be oriented parallel to or perpendicular to the direction of the pins, thus
providing optimum flexibility for cooling requirements. The order number
for the top mounted heatsink kit with metric screws is ‘NFC40-HTSK-T’.
The order number for the top mounted heatsink kit with imperial screws is
NFC40-HTSK-T-I’.
INPUT OUTPUT OUTPUT INPUT TYPICAL MODEL NUMBER (10)
VOLTAGE VOLTAGE CURRENT (MAX.) CURRENT (1) EFFICIENCY
18-36VDC 5V/±12V 6A/±0.4A 50mA 83% BXA40-24T05-12-M
18-36VDC 5V/±15V 6A/±0.3A 50mA 83% BXA40-24T05-15-M
36-75VDC 5V/±12V 6A/±0.4A 30mA 83% BXA40-48T05-12-M
36-75VDC 5V/±15V 6A/±0.3A 30mA 83% BXA40-48T05-15-M
PIN CONNECTIONS
PIN NUMBER TRIPLE OUTPUT
1 + Input
2 – Input
3 Control
4 + Output (V2)
5 Common
6 - Output (V3)
7 + Output (V1)
8 - Output (V1)
9 No Connection
40 Watt
Wide input DC/DC converters
DC/DC CONVERTERS |
40W DC/DC
PAGE 141
http://www.artesyn.com
BOTTOM VIEW
ALL DIMENSIONS IN INCHES (mm)
0.3
(7.62)
0.019
(0.50)
0.50
(12.70) 0.15
(3.90)
321
98 76 5 4
2.20 ±0.02
(
5
5
.
9
0 ±0.50
)
1.90
(
4
8
.
2
6
)
1.80
(
4
5
.
7
2
)
0.15
(
3
.
8
2
)
0.05
(
1
.
2
7
)
0.2
(5.08)
0.1
(2.54)
0.6
(15.24)
0.8
(20.32) 0.5
(12.70)
0.2
(5.08)
0.60
(15.24)
1.25
(31.76)
1.90
(48.26)
0.15
(3.82)
0.256 (6.50) Diameter
Stand-off (4 Places)
Metric (Suffix '-M'):
M3 Tap Thru. 4 places or
Imperial (No '-M' suffix) 4-
40 UNC (Optional)
1.02 (0.043)
Diameter Typ.
TOLERANCE : ± 0.004 (0.1)
(Unless otherwise specified)
2.20 ±0.02
(
5
5
.
9
0 ±0.50
)
5
Please consult our website for the following items: Design Note
DS_BXA40T_20000101.PDF