2 Fluke Corporation Fluke 424D, 419D, and 414D Distance Meters
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2007-2012 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 4/2012 3028711E D-EN-N
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke. Keeping your world
up and running.®
General specifications
Why use a distance meter?
Instant measurements up to 100 meters/330 feet. Just point, click, done.
Measure with greater accuracy. Up to ± 1 mm. No scales to interpret or misread.
Do the work of two. Instead of holding the tape, your helper can do other jobs.
Speed up the job. Easily measure hard-to-access areas, like high ceilings, without
climbing a ladder.
Keep it on the level. New inclination sensor on the Fluke 424D helps with leveling,
height tracking, and measuring around obstacles.
Reduce estimating errors—let the meters do the math. Find area and volume. Easily
add and subtract distances. Use Pythagoras calculations for height.
Trust Fluke tools. Rugged and reliable, dust- and splash-proof, you can work indoors
and out with confidence, because they’re Fluke tools.
For more information visit www.fluke.com/distance
Ordering information
Fluke 424D Laser Distance Meter
Fluke 419D Laser Distance Meter
Fluke 414D Laser Distance Meter
All models include: Laser distance meter, two AAA
batteries, users manual on CD, quick reference guide,
vinyl carrying pouch, and three-year warranty
414D 419D 424D
Distance measurement
Typical measuring tolerance[1] ± 2.0 mm[3] ± 1.0 mm[3]
Maximum measuring tolerance[2] ± 3.0 mm[3] ± 2.0 mm[3]
Range at Leica target plate GZM26 50 m/165 ft 80 m/260 ft 100 m/330 ft
Typical range[1] 40 m/130 ft 80 m/260 ft 80 m/260 ft
Range at unfavorable condition[4] 35 m/115 ft 60 m/195 ft 60 m/195 ft
Smallest unit displayed 1 mm /1/16 in 1 mm /1/32 in
Power Range Technology™ no yes yes
laser point at distances 6/30/60 mm (10/50/100 m)
0.23/1.18/2.36 in (32.8/164/330)
6/30/60 mm (10/50/100 m)
0.23/1.18/2.36 in (32.8/164/330)
Tilt measurement
Measuring tolerance to laser beam[5] no no ± 0.2°
Measuring tolerance to housing[5] no no ± 0.2°
Range no no 360°
General
Laser class II
Laser type 635 nm, <1 mW
Protection class IP40 IP54
Automatic laser off After 90 seconds
Automatic power off After 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 up to 3,000 measurements up to 5,000 measurements
Size (HxWxD) 116 mm x 53 mm x 33 mm
(4.56 in x 2.08 in x 1.29 in)
127 mm x 56 mm x 33 mm
(5 in x 2.20 in x 1.29 in)
127 mm x 56 mm x 33 mm
(5 in x 2.20 in x 1.29 in)
Weight (with batteries) 113 g (3.98 oz) 153 g (5.39 oz) 158 g (5.57 oz)
Temperature range: Storage
Operation
-25 °C to +70°C (-13 °F to +158 °F)
0 °C to +40 °C (32 °F to +104 °F)
-25 °C to +70°C (-13 °F to +158 °F)
-10 °C to +50 °C (14 °F to +122 °F)
Calibration cycle Not applicable Not applicable tilt and compass
Maximum altitude 3000 m 3000 m 3000 m
Maximum relative humidity 85 % at 20 °F to 120 °F
(-7 °C to 50 °C)
85 % at 20 °F to 120 °F
(-7 °C to 50 °C)
85 % at 20 °F to 120 °F
(-7 °C to 50 °C)
Safety CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01,
IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
EMC 61326-1:2006
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).
[2] Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to
+122 °F).
[3] Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The
maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft)
and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).
[4] Applies for 100 % target reflectivity, background illumination between 10’000 lux and 30’000 lux.
[5] After user calibration. Additional angle related deviation of ± 0.01° per degree up to ± 45° in each
quadrant. Applies at room temperature. For the whole operating temperature range the maximum
deviation increases by ± 0.1°.