Digital Oscilloscope Bandwidth 1GHz, 600 MHz Sample Rate Up to 5 GSa/s Channels 2 or 4 Memory 140 Mpts(Std.) Waveform capture rate Up to 180,000 waveforms per second, Real Time Waveform Record, Replay & Analysis(Std. up to 200,000 frames) Innovative "UltraVision" technology A variety of Trigger functions and Automatic measurements with statistics Support serial bus trigger(Std.) and decoding(Opt.) Dedicated data search knob" WaveFinder " Battery Option (China Only) Complete Connectivity: USB, LAN(LXI-C), VGA, AUX, GPIB(Option) Built-in 1 GBytes Flash Memory 10.1 inch WVGA(800X480) Display DS6000 series adopt many today's new technologies to achieve high performance, abundant features in the same class. It's designed to aim at the requirements of the largest digital oscilloscope market segment from the communications, semiconductor, computing, aerospace defense, instrumentation, research/education, industrial electronics, consumer electronics and automotive industries with its innovative technology, industry leading specifications, powerful trigger functions and broad analysis capabilities. RIGOL TECHNOLOGIES,INC. Product DimensionsWidthxHeight xDepth=399mmx255.3mmx123.8mm Weight:5.35 kg * Deeper Memory Depth(Std.140Mpts) * Higher Waveform capture rate (Up to 180,000 wfms/s) * Real Time waveform Record,Replay & Analysis (Up to 200,000 frames) * Multi-level intensity grading display Models and key Specs Waveform capture rate 200,000 UltraVision: Up to 180K Waveforms/s Waveform capture rate UltraVision: Multi-Level intensity grading display UltraVision: Real time waveform Record,Replay & Analysis Advanced math function Standard Mask test function Auto measurements with statistics(Measure up to 5 parameters simultaneously) Standard Serial Bus trigger functions (RS232,I2C,SPI,CAN etc.) Optional Serial bus decoding function with listing display The probes supported by DS6000 series: RIGOL Passive Probes Model Number Tpye RIGOL Active & Current Probes Description 1X: DC~7MHz High Z 10X:DC~150MHz Probe Compatibility All RIGOL Scopes. Model Number RP7150 Tpye Differential BW:DC~1.5GHz,30V Peak, CAT I /Single Compatibility ended DS40006000 series. Probe RP2200 1X: DC~8MHz High Z 10X:DC~350MHz Probe Compatibility All RIGOL Scopes. Current Probe BW:DC~300kHz, Max.DC:100A, AC P-P:200A,AC RMS:70A CompatibilityAll RIGOL Scopes. Current Probe BW:DC~1MHz, Max.DC:70A, AC P-P:140A,AC RMS:50A Compatibility All RIGOL Scopes. Current Probe RP1003C BW:DC~50MHz, Max.AC RMS:30A AC Peak:50A(Noncontinuous) Compatibility All RIGOL Scopes. Must order RP1000P Power supply. Current Probe RP1004C BW:DC~100MHz, Max. AC RMS:30A, AC Peak:50A(Noncontinuous) Compatibility All RIGOL Scopes. Must order RP1000P Power supply. Current Probe RP1005C BW:DC~10MHz, Max.150 A rms, 300 A peak (Noncontinuous), 500 A peak (@pulse width <=30 ms) Compatibility All RIGOL Scopes. Must order RP1000P Power supply. Power Supply Power supply for RP1003C,RP1004C,RP1005C, support 4 channels. RP1001C RP3300A DC~500MHz High Z Compatibility Probe All RIGOL Scopes. RP3500A DC~600MHz High Z Compatibility Probe DS4000,6000 Series. RP1002C RP5600A DC~1.5GHz Low Z Compatibility Probe DS4000,6000 Series. Description RP6150A RP1000P DC~300MHz High CATI 2000V(DC+AC), Voltage CATII 1500 V(DC+AC) Probe Compatibility All RIGOL Scopes. RP1025D RP1300H DC~50MHz DC:0~15KV High DC,AC:pulse <=30KVp-p, Voltage AC:sine wave <=10KVrms Probe Compatibility All RIGOL Scopes. RP1050H RP1050D RP1100D High Voltage Differential Probe BW:25MHz; Max. Voltage 1400Vpp Compatibility All RIGOL Scopes. High Voltage Differential Probe BW:50MHz; Max. Voltage 7000Vpp Compatibility All RIGOL Scopes. High Voltage Differential Probe BW:100MHz; Max. Voltage 7000Vpp Compatibility: All RIGOL scopes Other accessories All the specifications are guaranteed except the parameters marked with "Typical" and the oscilloscope needs to operate for more than 30 minutes under the specified operation temperature. Sample Sample Mode Real Time Sample Rate Equivalent Sample Rate Peak Detect Averaging High Resolution Memory Depth Input Number of Channels Input Coupling Input Impedance Probe Attenuation Coefficient Maximum Input Voltage (1M) Real-time Sample, Equivalent Sample 5 GSa/s (single-channel) 2.5 Gsa/s (dual-channel) 100 Gsa/s 200 ps (single-channel) 400 ps (dual-channel) After all the channels finish N samples at the same time, N can be 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 or 8192. 12 bits of resolution when 5 s/div @ 5 GSa/s (or 10 s/div @ 2.5 GSa/s). single-channel: Auto, 14k pts, 140k pts, 1.4M pts, 14M pts and 140M pts are available dual-channel: Auto, 7k pts, 70k pts, 700k pts, 7M pts and 70M pts are available DS6XX4: four channels DS6XX2: two channels DC, AC or GND (1 M1%) || (14 pF3 pF) or 50 1.5% 0.01X-1000X,1-2-5 step Maximum Input Voltage of the Analog Channel CAT I 300 Vrms, CAT II 100 Vrms, Transient Overvoltage 1000V pk with RP2200 10:1 probe: CAT II 300 Vrms with RP3300 10:1 probe: CAT II 300 Vrms with RP3500 10:1 probe: CAT II 300 Vrms with RP5600 10:1 probe: CAT II 300 Vrms Horizontal Timebase Scale Time Base Accuracy Time Base Drift Delay Range Timebase Mode Number of XYs Waveform Capture Rate[1] DS606X: 1 ns/div to 1000 s/div DS610X: 500 ps/div to 1000 s/div 4 ppm 2 ppm/Year Pre-trigger (negative delay): 1 screen width Post-trigger (positive delay): 1 s to 100,000 s Y-T, X-Y, Roll, Time Delayed 2 simultaneously (four channels model) 150,000 wfms (vector display); 180,000 wfms (dots display) Vertical Bandwidth (-3dB) DS606X: DC to 600 MHz DS610X: DC to 1 GHz DS606X: DC to 600 MHz Single-shot Bandwidth DS610X: DC to 1 GHz (each channel) 8bits, two channels sample at the Vertical Resolution same time 2 mV/div to 5 V/div (1 M) Vertical Scale 2 mV/div to 1 V/div (50 ) 2 mV/div to 124 mV/div: 1.2V (50 ) Offset Range 126 mV/div to 1 V/div: 12V (50 ) 2 mV/div to 225 mV/div: 2V (1M) 230 mV/div to 5 V/div: 40V (1M) Bandwidth Limit[2] 20 MHz or 250 MHz Low Frequency Response 5 Hz (on BNC) (AC Coupling -3dB) Calculated Rise Time[2] DS606X: 600 ps DS610X: 400 ps DC Gain Accuracy 2% full scale DC Offset Accuracy 200 mV/div to 5 V/div: 0.1 div 2 mV0.5% offset value 2 mV/div to 195 mV/div: 0.1 div 2 mV1.5% offset value ESD Tolerance 2 kV Channel to Channel DC to maximum band width: >40 dB Isolation Trigger Trigger Level Range Internal 6 div from center screen EXT 0.8 V Auto, Normal, Single 100 ns to 10 s 50 kHz 5 kHz Trigger mode Holdoff Range High Frequency Rejection[2] Low Frequency Rejection[2] Edge Trigger Rising, Falling, Rising&Falling Edge Type Pulse Trigger Positive Pulse Width (greater than, Pulse Condition lower than, within specific interval) Negative Pulse Width (greater than, lower than, within specific interval) 4 ns to 4 s Pulse Width Range Slope Trigger Slope Condition Positive Slope (greater than, lower than, within specific interval) Negative Slope (greater than, lower than, within specific interval) Time Setting 10 ns to 1 s Video Trigger Signal Standard Line Frequency Range Pattern Trigger Pattern Setting Support standard NTSC, PAL and SECAM broadcasting standards upport 480P,576P,720P,1080P and 1080I high definition standards H, L, X, Rising Edge, Falling Edge RS232/UART Trigger Trigger Condition Start, Error, Check Error, Data Polarity Normal,Invert Baud Rate 2400bps, 4800bps, 9600bps, 19200bps, 38400bps, 57600bps, 115200bps, User Data Bits 5 bit, 6 bit, 7 bit, 8 bit I2C Trigger Trigger Condition Start, Restart, Stop, Missing ACK, Address, Data, A&D Address Bits 7 bit, 8 bit ,10 bit Address Range 0 to 127, 0 to 255,0 to 1023 Byte Length 1 to 5 SPI Trigger Trigger Condition CS, Timeout Timeout Value 100ns to 1s Data Bits 4 bit to 32 bit Data Line Setting H, L, X Clock Edge Rising Edge, Falling Edge CAN Trigger Signal Type Trigger Condition Baud Rate Sample Point Frame Type Error Type FlexRay Trigger Baud Rate Trigger Condition USB Trigger Signal Speed Trigger condition Measure Cursor Auto Measurement Number of Measurements Measurement Range Measurement Statistic Rx, Tx, CAN_H, CAN_L, Differential SOF, EOF, Frame Type, Frame Error 10 kbps, 20 kbps, 33.3 kbps, 50 kbps, 62.5 kbps, 83.3 kbps, 100 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps, 1 Mbps, User 5% to 95% Data, Remote, Error, OverLoad Bit Fail,Answer Error,Check Error,Format Error,Random Error 2.5Mb/s, 5Mb/s, 10Mb/s Frame, Symbol, Error, TSS Low Speed, Full Speed SOP, EOP, RC, Suspended, ExitSuspend Manual Mode Voltage Deviation between Cursors (V) Time Deviation between Cursors (T) Reciprocal of T (Hz) (1/T) Track Mode Voltage and Time Values of the Waveform Point Auto Mode Allow to display cursors during auto measurement Measurements of Maximum, Minimum, Peak-Peak Value, Top Value, Bottom Value, Amplitude, Average, Mean Square Root, Overshoot, Pre-shoot, Area, PeriodArea,Frequency, Period, Rise Time, Fall Time, Positive Pulse Width, Negative Pulse Width, Positive Duty Cycle, Negative Duty Cycle, Delay A~B , Delay A~B , Phase A~B , Phase A~B Display 5 measurements at the same time Screen or cursor Average, Max, Min, Standard Deviation, Number of Measurements Frequency Counter Hardware 6 bits frequency counter (channels are selectable) Math Operation Waveform Operation A+B, A-B, AxB, A/B, FFT, Editable Advanced Operation, Logic Operation FFT Window Function Rectangle, Hanning, Blackman, Hamming FFT Display Split, Full Screen FFT Vertical Scale dB,Vrms Logic Operation AND, OR, NOT, XOR Math Function Intg, Diff, Log, Exp, Sqrt, Sine, Cosine, Tangent Number of Buses for 2 Decoding Decoding Type Parallel (standard), RS232/UART (option), I2C/ SPI(option), CAN (option), FlexRay (option) Display Display Type Display Resolution Display Color Persistence Time Display Type Real-time Clock I/O Standard Ports Printer Compatibility 10.1 inches (257 mm) TFT LCD display 800 Horizontal xRGBx480 Vertical Pixel 160,000 Color Minimum, 50 ms, 100 ms, 200 ms, 500ms, 1 s, 2 s, 5 s, 10 s, 20 s, Infinite Dots, Vectors Time and Date (user adjustable) USB DEVICE, two USB HOST ports, LAN, VGA Output, 10 MHz Input/Output, Aux output ( TrigOut,Fast, GND, PassFail, Calibration) PictBridge General Specifications Probe Compensation Output Output Voltage[2] About 3 V, peak-peak Frequency[2] 1 kHz Power Power Voltage 100-120 V/50Hz/60Hz/400Hz 100-240 V/50 Hz/60Hz Power Maximum 150W Fuse 3 A, T Degree, 250 V Environment Temperature Range Operation: 0to +50 Non-Operation: -20 to +70 fan cooling Cooling Method Under +35: 90% Relative Humidity Humidity Range +35 to +50: 60% Relative Humidity Operation: under 3,000 meters Altitude Non-Operation: under 15,000 meters Physical Characteristics WidthxHeightxDepth = Size[3] 399.0 mmx255.3 mmx123.8 mm Package Excluded 5.3 kg 0.2 kg Weight[4] Package Included 10.8 kg 1.0 kg Calibration Interval The recommended calibration interval period is one year. Regulatory Information Electromagnetic 2004/108/EC Compatibility Execution standard EN 61326-1:2006 EN 61326-2-1:2006 Safety UL 61010-1:2004 ; CAN/CSA-C22.2 NO. 61010-1-2004 ; EN 61010-1:2001 ; IEC 61010-1:2001 Note [1] :Maximum value. In single-channel mode, sine signal with 10 ns horizontal scale, 4 div input amplitude and 10 MHz frequency, edge trigger. [2] Note :Typical. [3] Note :Tilt tabs and handle folded, knob height included, front panel cover excluded. [4] Note :DS6104 model, standard configuration. Ordering Information Model Standard Accessories Optional Accessories Decoding Options Description DS6104 (1 GHz, 4-channel) DS6102 (1 GHz, dual-channel) DS6064 (600 MHz, 4-channel) DS6062 (600 MHz, dual-channel) Power Cord conforming to the standard of the country Front Panel Cover USB Data Cable 600MHz BW Passive Probe,4 sets for 4 channel models,2 sets for 2 channel models 1.5GHz BW Passive Probe,2 sets for DS6104,1 set for DS6102 Quick Guide Resource CD (User's Guide and Application Software) 1.5GHz Active Differential Probe 500MHz BW Passive Probes(Support all models) 600MHz BW Passive Probe(Support all models) 1.5GHz BW Passive Probe(Support all models) 11.1 V, 147 Wh Lithium Battery Set USB to GPIB Module Desk Mount Instrument Arm Rack Mount Kit RS232/UART Decoding kit I2C/SPI Decoding kit CAN Decoding kit FlexRay Decoding Kit Warranty Three-year warranty,excluding probes and accessories. Order Number DS6104 DS6102 DS6064 DS6062 FPCS-DS6000 CB-USBA-USBB-FF-150 RP5600A RP6150A RP7150 RP3500A RP5600A RP6150A BAT (China Only) USB-GPIB ARM RM-DS6000 SD-RS232-DS6000 SD-I2C/SPI-DS6000 SD-CAN-DS6000 SD-FlexRay-DS6000 HEADQUARTER EUROPE NORTH AMERICA JAPAN RIGOL TECHNOLOGIES, INC. No.156,Cai He Village, Sha He Town, Chang Ping District, Beijing, 102206 P.R.China Tel:+86-10-80706688 Fax:+86-10-80705070 Electronic Measurement Instrument service and support email:EMD_support@rigol.com Chemical Analysis Instrument service and support email:service. chem@rigol.com RIGOL TECHNOLOGIES GmbH Lindbergh str. 4 82178 Puchheim Germany Tel: 0049- 89/89418950 Email: info-europe@rigoltech.com RIGOL TECHNOLOGIES, USA INC. 10200 SW Allen Blvd, Suite C Beaverton, OR 97005, USA Toll free: 877-4-RIGOL-1 Office: (440) 232-4488 Fax: (216)-754-8107 Email: info@rigol.com RIGOL TECHNOLOGIES JAPAN G.K. Tonematsu Bldg. 5F, 2-33-8 NihonbashiNingyocho, Chuo-ku, Tokyo 103-0013 Japan Tel: +81-3-6264-9251 Fax: +81-3-6264-9252 Email: info-japan@rigol.com RIGOL(R) is the registered trademark of RIGOL Technologies, Inc. Product information in this document subject to update without notice. For the latest information about RIGOL's products, applications and services, please contact local RIGOL office or access RIGOL official website: www.rigol.com November 2015