Bandwidth 1GHz, 600 MHz
Sample Rate Up to 5 GSa/s
Channels 2 or 4
Memory 140 Mpts(Std.)
Waveform capture rate Up to 180,000 waveforms per second,
Real Time Waveform Record, Replay & Analysis(Std. up to
200,000 frames)
Innovative “UltraVision” technology
A variety of Trigger functions and Automatic measurements
with statistics
Support serial bus trigger(Std.) and decoding(Opt.)
Dedicated data search knob“ WaveFinder ”
Battery Option (China Only)
Complete Connectivity: USB, LAN(LXI-C), VGA, AUX, GPIB(Option)
Built-in 1 GBytes Flash Memory
10.1 inch WVGA(800X480) Display
DS6000 series adopt many today's new technologies to achieve high
performance, abundant features in the same class. It's designed to
aim at the requirements of the largest digital oscilloscope market
segment from the communications, semiconductor, computing,
aerospace defense, instrumentation, research/education, industrial
electronics, consumer electronics and automotive industries with its
innovative technology, industry leading specications, powerful trigger
functions and broad analysis capabilities.
Digital Oscilloscope
RIGOL TECHNOLOGIES,INC.
Product Dimensions:Width×Height ×Depth=399mm×255.3mm×123.8mm Weight:5.35 kg
Waveform capture rate
200,000
· Deeper Memory Depth(Std.140Mpts)
· Higher Waveform capture rate (Up to 180,000 wfms/s)
· Real Time waveform Record,Replay & Analysis
(Up to 200,000 frames)
· Multi-level intensity grading display
Models and key Specs
UltraVision: Up to 180K Waveforms/s Waveform
capture rate
UltraVision: Real time waveform Record,Replay &
Analysis
UltraVision: Multi-Level intensity grading display
Standard Serial Bus trigger functions
(RS232,I2C,SPI,CAN etc.)
Auto measurements with statistics(Measure up to 5
parameters simultaneously)
Advanced math function
Standard Mask test function
Optional Serial bus decoding function with listing display
The probes supported by DS6000 series:
RIGOL Passive Probes RIGOL Active & Current Probes
Model Number Tpye Description
RP2200
High Z
Probe
1X: DC~7MHz
10X:DC~150MHz
Compatibility:
All RIGOL Scopes.
RP3300A
High Z
Probe
1X: DC~8MHz
10X:DC~350MHz
Compatibility:
All RIGOL Scopes.
RP3500A
High Z
Probe
DC~500MHz
Compatibility:
All RIGOL Scopes.
RP5600A
High Z
Probe
DC~600MHz
Compatibility:
DS4000,6000 Series.
RP6150A
Low Z
Probe
DC~1.5GHz
Compatibility:
DS4000,6000 Series.
RP1300H
High
Voltage
Probe
DC~300MHz
CATI 2000V(DC+AC),
CATII 1500 V(DC+AC)
Compatibility:
All RIGOL Scopes.
RP1050H
High
Voltage
Probe
DC~50MHz
DC:0~15KV
DC,AC:pulse <=30KVp-p,
AC:sine wave <=10KVrms
Compatibility:
All RIGOL Scopes.
Model Number Tpye Description
RP7150
Differential
/Single
ended
Probe
BW:DC~1.5GHz,30V Peak, CAT I
Compatibility:
DS4000,6000 series.
RP1001C
Current
Probe
BW:DC~300kHz,
Max.DC:±100A,
AC P-P:200A,AC RMS:70A
Compatibility:All RIGOL Scopes.
RP1002C
Current
Probe
BW:DC~1MHz,
Max.DC:±70A,
AC P-P:140A,AC RMS:50A
Compatibility:
All RIGOL Scopes.
RP1003C
Current
Probe
BW:DC~50MHz,
Max.AC RMS:30A
AC Peak:50A(Noncontinuous)
Compatibility:
All RIGOL Scopes.
Must order RP1000P Power supply.
RP1004C
Current
Probe
BW:DC~100MHz,
Max. AC RMS:30A,
AC Peak:50A(Noncontinuous)
Compatibility:
All RIGOL Scopes.
Must order RP1000P Power supply.
RP1005C
Current
Probe
BW:DC~10MHz,
Max.150 A rms,
300 A peak (Noncontinuous),
500 A peak (@pulse width <=30 ms)
Compatibility:
All RIGOL Scopes.
Must order RP1000P Power supply.
RP1000P
Power
Supply
Power supply for
RP1003C,RP1004C,RP1005C,
support 4 channels.
RP1025D
High
Voltage
Differential
Probe
BW:25MHz;
Max. Voltage ≤ 1400Vpp
Compatibility:
All RIGOL Scopes.
RP1050D
High
Voltage
Differential
Probe
BW:50MHz;
Max. Voltage ≤ 7000Vpp
Compatibility:
All RIGOL Scopes.
RP1100D
High
Voltage
Differential
Probe
BW:100MHz;
Max. Voltage ≤ 7000Vpp
Compatibility:
All RIGOL scopes
Other accessories
Sample Mode
Real Time
Sample Rate
Equivalent
Sample Rate
Peak Detect
Averaging
High Resolution
Memory Depth
Number of
Channels
Input Coupling
Input Impedance
Probe
Attenuation
Coefcient
Maximum Input
Voltage (1MΩ)
Real-time Sample, Equivalent Sample
5 GSa/s (single-channel)
2.5 Gsa/s (dual-channel)
100 Gsa/s
200 ps (single-channel)
400 ps (dual-channel)
After all the channels nish N samples at the
same time, N can be 2, 4, 8, 16, 32, 64, 128,
256, 512, 1024, 2048, 4096 or 8192.
12 bits of resolution when ≥5 μs/div @ 5 GSa/s
(or ≥10 μs/div @ 2.5 GSa/s).
single-channel: Auto, 14k pts, 140k pts, 1.4M
pts, 14M pts and 140M pts are available
dual-channel: Auto, 7k pts, 70k pts, 700k pts,
7M pts and 70M pts are available
DS6XX4: four channels
DS6XX2: two channels
DC, AC or GND
(1 MΩ±1%) || (14 pF±3 pF)
or 50 Ω±1.5%
0.01X-1000X,1-2-5 step
Maximum Input Voltage of the Analog Channel
CAT I 300 Vrms, CAT II 100 Vrms,
Transient Overvoltage 1000V pk
with RP2200 10:1 probe: CAT II 300 Vrms
with RP3300 10:1 probe: CAT II 300 Vrms
with RP3500 10:1 probe: CAT II 300 Vrms
with RP5600 10:1 probe: CAT II 300 Vrms
Sample
Input
All the specifications are guaranteed except the parameters marked with “Typical” and
the oscilloscope needs to operate for more than 30 minutes under the specied operation
temperature.
Timebase Scale
Time Base Accuracy
Time Base Drift
Delay Range
Timebase Mode
Number of XYs
Waveform Capture
Rate[1]
Bandwidth (-3dB)
Single-shot Bandwidth
Vertical Resolution
Vertical Scale
Offset Range
Bandwidth Limit[2]
Low Frequency Response
(AC Coupling -3dB)
Calculated Rise Time[2]
DC Gain Accuracy
DC Offset Accuracy
ESD Tolerance
Channel to Channel
Isolation
DS606X: DC to 600 MHz
DS610X: DC to 1 GHz
DS606X: DC to 600 MHz
DS610X: DC to 1 GHz (each channel)
8bits, two channels sample at the
same time
2 mV/div to 5 V/div (1 MΩ)
2 mV/div to 1 V/div (50 Ω)
2 mV/div to 124 mV/div: ± 1.2V (50 Ω)
126 mV/div to 1 V/div: ± 12V (50 Ω)
2 mV/div to 225 mV/div: ± 2V (1MΩ)
230 mV/div to 5 V/div: ± 40V (1MΩ)
20 MHz or 250 MHz
≤5 Hz (on BNC)
DS606X: 600 ps
DS610X: 400 ps
±2% full scale
200 mV/div to 5 V/div:
0.1 div ± 2 mV±0.5% offset value
2 mV/div to 195 mV/div:
0.1 div ± 2 mV±1.5% offset value
±2 kV
DC to maximum band width: >40 dB
Horizontal
Vertical
Trigger
Trigger Level Range
Trigger mode
Holdoff Range
High Frequency Rejection[2]
Low Frequency Rejection[2]
Edge Trigger
Edge Type
Pulse Trigger
Pulse Condition
Pulse Width Range
Slope Trigger
Slope Condition
Time Setting
Rising, Falling, Rising&Falling
Positive Pulse Width (greater than,
lower than, within specic interval)
Negative Pulse Width (greater than,
lower than, within specic interval)
4 ns to 4 s
Positive Slope (greater than, lower than,
within specic interval)
Negative Slope (greater than, lower than,
within specic interval)
10 ns to 1 s
Internal
EXT
Auto, Normal, Single
100 ns to 10 s
50 kHz
5 kHz
± 6 div from center screen
± 0.8 V
DS606X: 1 ns/div to 1000 s/div
DS610X: 500 ps/div to 1000 s/div
≤ ± 4 ppm
≤ ± 2 ppm/Year
Pre-trigger (negative delay): ≥1 screen width
Post-trigger (positive delay): 1 s to 100,000 s
Y-T, X-Y, Roll, Time Delayed
2 simultaneously (four channels model)
150,000 wfms (vector display);
180,000 wfms (dots display)
Display
Display Type
Display Resolution
Display Color
Persistence Time
Display Type
Real-time Clock
I/O
Standard Ports
Printer Compatibility
10.1 inches (257 mm) TFT LCD display
800 Horizontal ×RGB×480 Vertical Pixel
160,000 Color
Minimum, 50 ms, 100 ms, 200 ms, 500ms,
1 s, 2 s, 5 s, 10 s, 20 s, Innite
Dots, Vectors
Time and Date (user adjustable)
USB DEVICE, two USB HOST ports, LAN,
VGA Output, 10 MHz Input/Output, Aux output
( TrigOut,Fast, GND, PassFail, Calibration)
PictBridge
Measure
Cursor
Auto Measurement
Number of
Measurements
Measurement Range
Measurement
Statistic
Manual Mode
Track Mode
Auto Mode
Measurements of Maximum, Minimum,
Peak-Peak Value, Top Value, Bottom
Value, Amplitude, Average, Mean Square
Root, Overshoot, Pre-shoot, Area,
PeriodArea,Frequency, Period, Rise Time,
Fall Time, Positive Pulse Width, Negative
Pulse Width, Positive Duty Cycle, Negative
Duty Cycle, Delay A~B , Delay A~B , Phase
A~B , Phase A~B
Display 5 measurements at the same time
Screen or cursor
Average, Max, Min, Standard Deviation,
Number of Measurements
Voltage Deviation between
Cursors (V)
Time Deviation between
Cursors (T)
Reciprocal of T (Hz) (1/T)
Voltage and Time Values of
the Waveform Point
Allow to display cursors
during auto measurement
Frequency Counter Hardware 6 bits frequency counter
(channels are selectable)
General Specications
Probe Compensation Output
Output Voltage[2]
Frequency[2]
Power
Power Voltage
Power
Fuse
Environment
Temperature Range
Cooling Method
Humidity Range
Altitude
Size[3]
Weight[4]
Note[1]:Maximum value. In single-channel mode, sine signal with 10 ns horizontal scale,
4 div input amplitude and 10 MHz frequency, edge trigger.
Note[2]:Typical.
Note[3]:Tilt tabs and handle folded, knob height included, front panel cover excluded.
Note[4]:DS6104 model, standard conguration.
About 3 V, peak-peak
1 kHz
100-120 V/50Hz/60Hz/400Hz
100-240 V/50 Hz/60Hz
Maximum 150W
3 A, T Degree, 250 V
Operation: 0to +50
Non-Operation: -20 to +70
fan cooling
Under +35: ≤90% Relative Humidity
+35 to +50: ≤60% Relative Humidity
Operation: under 3,000 meters
Non-Operation: under 15,000 meters
Width×Height×Depth =
399.0 mm×255.3 mm×123.8 mm
Package Excluded
Package Included
5.3 kg± 0.2 kg
10.8 kg± 1.0 kg
Math Operation
Waveform Operation
FFT Window Function
FFT Display
FFT Vertical Scale
Logic Operation
Math Function
Number of Buses for
Decoding
Decoding Type
A+B, A-B, A×B, A/B, FFT, Editable Advanced
Operation, Logic Operation
Rectangle, Hanning, Blackman, Hamming
Split, Full Screen
dB,Vrms
AND, OR, NOT, XOR
Intg, Diff, Log, Exp, Sqrt, Sine, Cosine, Tangent
2
Parallel (standard), RS232/UART (option), I2C/
SPI(option), CAN (option), FlexRay (option)
Physical Characteristics
Calibration Interval
The recommended calibration interval period is one year.
Regulatory Information
Electromagnetic
Compatibility
Safety
2004/108/EC
Execution standard EN 61326-1:2006 EN
61326-2-1:2006
UL 61010-1:2004 ; CAN/CSA-C22.2 NO.
61010-1-2004 ;
EN 61010-1:2001 ; IEC 61010-1:2001
Support standard NTSC, PAL and SECAM
broadcasting standards
upport 480P,576P,720P,1080P and 1080I high
denition standards
H, L, X, Rising Edge, Falling Edge
RS232/UART Trigger
Trigger Condition
Polarity
Baud Rate
Data Bits
Trigger Condition
Address Bits
Address Range
Byte Length
I2C Trigger
Start, Error, Check Error, Data
Normal,Invert
2400bps, 4800bps, 9600bps, 19200bps,
38400bps, 57600bps, 115200bps, User
5 bit, 6 bit, 7 bit, 8 bit
Start, Restart, Stop, Missing ACK, Address,
Data, A&D
7 bit, 8 bit ,10 bit
0 to 127, 0 to 255,0 to 1023
1 to 5
Video Trigger
Signal Standard
Line Frequency
Range
Pattern Trigger
Pattern Setting
SPI Trigger
Trigger Condition
Timeout Value
Data Bits
Data Line Setting
Clock Edge
CAN Trigger
Signal Type
Trigger Condition
Baud Rate
Sample Point
Frame Type
Error Type
FlexRay Trigger
Baud Rate
Trigger Condition
USB Trigger
Signal Speed
Trigger condition
CS, Timeout
100ns to 1s
4 bit to 32 bit
H, L, X
Rising Edge, Falling Edge
Rx, Tx, CAN_H, CAN_L, Differential
SOF, EOF, Frame Type, Frame Error
10 kbps, 20 kbps, 33.3 kbps, 50 kbps, 62.5
kbps, 83.3 kbps, 100 kbps, 125 kbps, 250
kbps, 500 kbps, 800 kbps, 1 Mbps, User
5% to 95%
Data, Remote, Error, OverLoad
Bit Fail,Answer Error,Check Error,Format
Error,Random Error
2.5Mb/s, 5Mb/s, 10Mb/s
Frame, Symbol, Error, TSS
Low Speed, Full Speed
SOP, EOP, RC, Suspended, ExitSuspend
Ordering Information
Description
DS6104 (1 GHz, 4-channel)
DS6102 (1 GHz, dual-channel)
DS6064 (600 MHz, 4-channel)
DS6062 (600 MHz, dual-channel)
Power Cord conforming to the standard of the country
Front Panel Cover
USB Data Cable
600MHz BW Passive Probe,4 sets for 4 channel models,2 sets for
2 channel models
1.5GHz BW Passive Probe,2 sets for DS6104,1 set for DS6102
Quick Guide
Resource CD (User’s Guide and Application Software)
1.5GHz Active Differential Probe
500MHz BW Passive Probes(Support all models)
600MHz BW Passive Probe(Support all models)
1.5GHz BW Passive Probe(Support all models)
11.1 V, 147 Wh Lithium Battery Set
USB to GPIB Module
Desk Mount Instrument Arm
Rack Mount Kit
RS232/UART Decoding kit
I2C/SPI Decoding kit
CAN Decoding kit
FlexRay Decoding Kit
Order Number
DS6104
DS6102
DS6064
DS6062
-
FPCS-DS6000
CB-USBA-USBB-FF-150
RP5600A
RP6150A
-
-
RP7150
RP3500A
RP5600A
RP6150A
BAT (China Only)
USB-GPIB
ARM
RM-DS6000
SD-RS232-DS6000
SD-I2C/SPI-DS6000
SD-CAN-DS6000
SD-FlexRay-DS6000
Model
Standard Accessories
Optional Accessories
Decoding Options
Three-year warranty,excluding probes and accessories.
Warranty
HEADQUARTER
RIGOL TECHNOLOGIES, INC.
No.156,Cai He Village,
Sha He Town,
Chang Ping District, Beijing,
102206 P.R.China
Tel:+86-10-80706688
Fax:+86-10-80705070
Electronic Measurement
Instrument service and support
email:EMD_support@rigol.com
Chemical Analysis Instrument
service and support email:service.
chem@rigol.com
EUROPE
RIGOL TECHNOLOGIES GmbH
Lindbergh str. 4
82178 Puchheim
Germany
Tel: 0049- 89/89418950
Email: info-europe@rigoltech.com
NORTH AMERICA
RIGOL TECHNOLOGIES,
USA INC.
10200 SW Allen Blvd, Suite C
Beaverton, OR 97005, USA
Toll free: 877-4-RIGOL-1
Ofce: (440) 232-4488
Fax: (216)-754-8107
Email: info@rigol.com
JAPAN
RIGOL TECHNOLOGIES JAPAN G.K.
Tonematsu Bldg. 5F, 2-33-8 Nihonbashi-
Ningyocho, Chuo-ku,
Tokyo 103-0013
Japan
Tel: +81-3-6264-9251
Fax: +81-3-6264-9252
Email: info-japan@rigol.com
RIGOL® is the registered trademark of RIGOL Technologies, Inc. Product information in
this document subject to update without notice. For the latest information about RIGOL's
products, applications and services, please contact local RIGOL ofce or access RIGOL
ofcial website: www.rigol.com
November 2015