RATINGS AND CHARACTERISTIC CURVES SAC5.0 THRU SAC50 SERIES
TL, LEAD TEMPERATURE, °C
FIG. 3 - PULSE WAVEFORM
t, TIME, ms
IPPM, PEAK PULSE CURRENT, %
PERCENTAGE OF RATED POWER, (%)
PULSE WIDTH (td) is DEFINED
as the POINT WHERE the
PEAK CURRENT DECAYS
to 50% of IPP
tr=10µsec.
HALF VALUE - IPP
2
10/1000µsec.
WAVEFORM
AS DEFINED BY R.E.A.
PEAK VALUE
IPPM
FIG. 2 - POWER DERATING CURVE
FIG. 1 - PEAK PULSE POWER RATING CURVE
PPPM, PEAK PULSE POWER, kW
td, PULSE WIDTH, sec.
NON-REPETITIVE
PULSE WAVEFORM
SHOWN in FIG. 3
TA=25°C
IMPULSE
EXPONENTIAL
DECAY
HALF SINE
SQUARE
CURRENT WAVEFORMS
1.0
0.5
td
td
td
td
AVERAGE POWER
PEAK POWER
(SINGLE PULSE)
Minimum Maximum Maximum Maximum Maximum Working Inverse Peak
Stand-off Breakdown Reverse Clamping Peak Pulse Junction Inverse Blocking Inverse
Voltage Voltage Leakage Voltage Current Capacitance Blocking Leakage Blocking
(NOTE 1) at IT= 1.0mA at VWM at IPP=5.0A per FIG. 3 at Voltage Current Voltage
Part VWM V(BR) IDVc lPP 0 VOLTS VWIB at VWIB VPIB
Number (VOLTS) (VOLTS) (uA) (VOLTS) (AMPS) (pF) (VOLTS) IIB (mA) (VOLTS)
SAC5.0 5.0 7.60 300 10.0 44 50 75 1.0 100
SAC6.0 6.0 7.90 300 11.2 41 50 75 1.0 100
SAC7.0 7.0 8.33 300 12.6 38 50 75 1.0 100
SAC8.0 8.0 8.89 100 13.4 36 50 75 1.0 100
SAC8.5 8.5 9.44 50 14.0 34 50 75 1.0 100
SAC10 10 11.10 5.0 16.3 29 50 75 1.0 100
SAC12 12 13.30 5.0 19.0 25 50 75 1.0 100
SAC15 15 16.70 5.0 23.6 20 50 75 1.0 100
SAC18 18 20.00 5.0 28.8 15 50 75 1.0 100
SAC22 22 24.40 5.0 35.4 14 50 75 1.0 100
SAC26 26 28.90 5.0 42.3 11.1 50 75 1.0 100
SAC30 30 33.30 5.0 48.6 10.0 50 75 1.0 100
SAC36 36 40.00 5.0 60.0 8.6 50 75 1.0 100
SAC45 45 50.00 5.0 77.0 6.8 50 150 1.0 200
SAC50 50 55.50 5.0 88.0 5.8 50 150 1.0 200
ELECTRICAL CHARACTERISTICS at (TA=25°C unless otherwise noted) TABLE 1
FIG. 4 - AC LINE PROTECTION APPLICATION
APPLICATION NOTE: Device must be used with two units in parallel, opposite in
polarity as shown in circuit for AC signal line protection
LOW CAPACITANCE