The 3Com® SuperStack®3 Advanced
Redundant Power System provides
crucial protection for SuperStack
components, ensuring that businesses
experience no loss of data or connec-
tivity during power interruptions or
failures. This modular system
incorporates eight slots that accept one
of four varieties of hot-swappable
power modules, each capable of
supporting one SuperStack device.
For extra protection, two modules can
be connected using a Y-cable to create a
completely redundant system powering
a single SuperStack device. If one
module fails, the second takes over
without disrupting other devices.
Modules can be installed together in
various combinations within a single
SuperStack 3 Advanced Redundant
Power System chassis, depending on
the power consumption of SuperStack 3
components being protected. The
chassis can support up to eight Type 1
60W modules, four Type 1 100W or
Type 2A 100W modules, or two Type 3
325W modules.
With the SuperStack 3 Advanced
Redundant Power System, businesses
enjoy peace of mind knowing that their
network remains trouble free and
operational at all times. Plus, they
receive added assurance with the
knowledge that the system is backed by
the proven reliability of 3Com and a
lifetime limited warranty.
Feature Benefits
High availability Redundant power supplies, with hot-
swappable power modules provide
high availability operation.
Modular, hot-swappable solution Provides extra assurance that the
network will remain operational
during power interruptions and
failures.
Complete redundancy Two ARPS modules can be connected
using a Y-cable, providing total
resilience.
Dual phase mains power Additional resilience can be achieved
by using mains from different phase
supplies or by using an uninterruptible
power system (UPS) input as a back
up to the primary mains input.
Reliable back-up The SuperStack 3 Advanced
Redundant Power System ensures
reliable network operation even in
the unlikely event of a power supply
failure.
3COM® SUPERSTACK®3 ADVANCED REDUNDANT POWER SYSTEM DATA SHEET
Feature Benefits
Industry-leading solution 3Com back-up products are
recommended by leading UPS
vendors, including the American
Power Conversion Corporation; for
more details, please visit
http://3com.apcc.com.
Flexible system Provides the flexibility of
freestanding or rack-mountable
operation in a standard wiring closet
rack.
Management The advanced RPS management
module provides network
management of the Advanced RPS
through monitoring and control.
Supports 3Com® Network Supervisor
management software, and other
SNMP management tools.
Features and Benefits,
continued
3COM® SUPERSTACK®3 ADVANCED REDUNDANT POWER SYSTEM DATA SHEET
SuperStack Advanced
Redundancy Power
System Power Module
Compatibility Table
Use the following table to select the
SuperStack Advanced Redundant
Power System power module that
supports your SuperStack 3 and
SuperStack II components.
Product Modular Type Power
Switches
SuperStack 3 Switch 4950 Type 3 325W
SuperStack 3 Switch 4924 Type 3 325W
SuperStack 3 Switch 4900 Type 3 325W
SuperStack 3 Switch 4900 SX Type 3 325W
SuperStack 3 Switch 4400 24- and 48-port Type 2A 100 W
SuperStack 3 Switch 4400 24-port SE Type 2A 100 W
SuperStack 3 Switch 4300 Type 2A 100 W
SuperStack 3 Switch 3300 12- and 24-port Type 2A 100 W
SuperStack 3 Switch 3300 MM Type 2A 100 W
SuperStack 3 Switch 3300 SM Type 2A 100 W
SuperStack 3 Switch 3300 TM Type 2A 100 W
SuperStack 3 Switch 3300 XM Type 2A 100 W
SuperStack 3 Baseline 10/100 12- and 24-port Type 1 100 W
SuperStack 3 Baseline 10/100 24-port
plus 1000BASE-T Type 2A 100 W
SuperStack 3 Baseline 10/100/1000 Type 2A 100 W
SuperStack II Switch 3300 FX Type 2A 100 W
Hubs
SuperStack II PS Hub 40 Type 1 100 W
SuperStack II PS Hub 50 Type 1 60W
SuperStack II Dual Speed Hub 500 Type 2A 100W
Web Solutions
SuperStack 3 Firewall Type 1 100 W
SuperStack 3 Server Load Balancer Type 3 325W
When there is a switch unit power supply failure and a single ARPS chassis
and related modules are utilized, the switch unit will experience a typical 5-20
second delay before normal operation is resumed.
For completely uninterrupted operation, two ARPS chassis and modules must
be used in conjunction with a Y cable, and the switch unit be powered
entirely from two ARPS Chassis. With this configuration, no reset period will
be experienced should an ARPS Chassis or mains supply fail.
The SuperStack 3 Advanced Redundant Power System can support any
combination of the above modules, up to its rated maximum power of 480
Watts. An exception can be made in the case of the Type 3 module, whereby
two of these modules can be installed into a single chassis.
3COM® SUPERSTACK®3 ADVANCED REDUNDANT POWER SYSTEM DATA SHEET
Specifications
SuperStack 3 Advanced Redundant Power System
(includes chassis and rack mount kit) 3C16071B
Advanced Redundant Power System 60W Power
Module Type 1 3C16072
Advanced Redundant Power System 100W Power
Module Type 1 3C16073
Advanced Redundant Power System 100W Power
Module Type 2A 3C16074A
Advanced Redundant Power System 325W Power
Module Type 3 3C16075
Advanced Redundant Power System Y-Cable
Type 1 3C16079
Advanced Redundant Power System Y-Cable
Type 2A 3C16078
Advanced Redundant Power System Y-Cable
Type 3 3C16077
Management Module 3C16080
Ordering Information
Physical Dimensions
Chassis (empty)
Weight: 18.7 lb (8.5 kg)
Height: 2U
Width: 17.3 in (440 mm)
Depth: 14.5 in (370 mm)
Power modules
Weight: 1.21 lb (550 g)
Height: 1.6 in (40 mm)
Width: 3.4 in (86 mm)
Depth: 10.5 in (267 mm)
Environmental
EN 60068 to 3Com Schedule
Operating temperature: 0° to 50°C (32° to 122°F)
Power
Chassis (with no power module)
Input voltage range: 85 to 264V RMS
Input frequency: 47 to 63Hz
Power consumption: 7 to 10W
60W Type 1 power module
Typical input power: 100W
Maximum power output:
5V, 8.5A
12.6V, 2.5A
-12.0V, 1A
Total output power: 60W max.
100W Type 1 power module
Typical input power: 167W
Maximum power output:
5V, 15A
12.6V, 2.5A
-12V, 1A
Total output power: 100W max
Type 2A Module
Typical Input Power : 167W
Maximum Output Power
+12 volts, 1A
+5 volts, 15A
+3. 3 volts, 25A
Total continuous output: 100W max
Type 3 Module
Typical Input Power : 395W
Maximum Output Power
+27.0 volts, 12.5A
Total continuous output: 325W max
Regulatory Compliance
Safety
UL1950
EN 60950
CSA 22.2 No. 950-M93
EMC
CSA C108.8 - M1983 Class A
FCC Part 15 Class A
VCCI Class 2
EN55022, 1995 Class B
EN61000-3-2, 1995
EN500082-2, 1995
EN61000-4-5
Hardware Warranty
Limited Lifetime warranty. See
www.3com.com/warranty for details.
3Com Corporation, Corporate Headquarters, 5400 Bayfront Plaza, P.O. Box 58145, Santa Clara, CA 95052-8145
To learn more about 3Com solutions, visit www.3com.com. 3Com Corporation is publicly traded on Nasdaq under the
symbol COMS.
Copyright © 2002 3Com Corporation. All rights reserved. 3Com, the 3Com logo, and SuperStack are registered
trademarks of 3Com Corporation. All other company and product names may be trademarks of their respective
companies. While every effort is made to ensure the information given is accurate, 3Com does not accept liability for any
errors or mistakes which may arise. All specifications are subject to change without notice. 400625-004 10/02